• 제목/요약/키워드: Microelectrode Probe

검색결과 21건 처리시간 0.028초

Neural Interface with a Silicon Neural Probe in the Advancement of Microtechnology

  • Oh, Seung-Jae;Song, Jong-Keun;Kim, Sung-June
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • 제8권4호
    • /
    • pp.252-256
    • /
    • 2003
  • In this paper we describe the status of a silicon-based microelectrode for neural recording and an advanced neural interface. We have developed a silicon neural probe, using a combination of plasma and wet etching techniques. This process enables the probe thickness to be controlled precisely. To enhance the CMOS compatibility in the fabrication process, we investigated the feasibility of the site material of the doped polycrystalline silicon with small grains of around 50 nm in size. This silicon electrode demonstrated a favorable performance with respect to impedance spectra, surface topography and acute neural recording. These results showed that the silicon neural probe can be used as an advanced microelectrode for neurological applications.

신경신호기록용 탐침형 반도체 미세전극 어레이의 제작 (Fabrication of Depth-probe type Silicon Microelectrode array for Neural signal Recording)

  • 윤태환;황은정;신동용;김성준
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1998년도 추계학술대회
    • /
    • pp.147-148
    • /
    • 1998
  • In this paper, we developed the process for depth-probe type silicon microelectrode arrays. The process consists of four mask steps only. The steps are for defining sites, windows, and for shaping probe using plasma etch from above, and for shaping using wet etch from below, respectively. The probe thickness is controlled by dry etching, not by impurity diffusion. We used gold electrodes with a triple dielectric system consisting of oxide/nitride/oxide. The shank of the probe taper from 200um to tens of urn tip and has 30 um thickness.

  • PDF

실리콘 건식식각과 습식식각을 이용한 신경 신호 기록용 탐침형 반도체 미세전극 어레이의 제작 (Fabrication of Depth Probe Type Semiconductor Microelectrode Arrays for Neural Recording Using Both Dry and wet Etching of Silicon)

  • 신동용;윤태환;황은정;오승재;신형철;김성준
    • 대한의용생체공학회:의공학회지
    • /
    • 제22권2호
    • /
    • pp.145-150
    • /
    • 2001
  • 대뇌 피질에 삽입하여 깊이에 따라 신경 신호를 기록하기 위한 탐침형 반도체 미세전극 어레이(depth-type silicon microelectrode array, 일명 SNU probe)를 제작하였다. 붕소를 확산시켜 생성된 고농도 p-type doping된 p+ 영역을 습식식각 정지점으로 사용하는 기존의 방법과 달리 실리콘 웨이퍼의 앞면을 건식식각하여 원하는 탐침 두께만큼의 깊이로 트렌치(trench)를 형성한 후 뒷면을 습식식각하는 방법으로 탐침 형태의 미세 구조를 만들었다. 제작된 반도체 미세전극 어레이의 탐침 두께는 30 $\mu\textrm{m}$이며 실리콘 건식식각을 위한 마스크로 6 $\mu\textrm{m}$ 두께의 LTO(low temperature oxide)를 사용하였다. 탐침의 두께는 개발된 본 공정을 이용해서 5~90 $\mu\textrm{m}$ 범위까지 쉽게 조절할 수 있었다. 탐침의 두께를 보다 쉽게 조절할 수 있게 됨에 따라 여러 신경조직에 필요한 다양한 구조의 반도체 미세전극 어레이를 개발할 수 있게 되었다. 본 공정을 이용해서 개발된 4채널 SUN probe를 사용하여 흰쥐의 제1차 체감각 피질에서 4채널 신경 신호를 동시에 기록하였으며, 전기적 특성검사에서 기존의 탐침형 반도체 미세전극, 텅스텐 전극과 대등하거나 우수한 신호대 잡음비(signal to noise ratio, SNR)특성을 가짐을 확인하였다.

  • PDF

미소전극 센서를 이용한 탈질 생물막내의 이온 농도측정 (Measurement of Ion Concentrations in Denitrifying Biofilm by Microelectro-sensor)

  • 장암;이쌍구;김성민;김인수
    • 대한환경공학회지
    • /
    • 제22권10호
    • /
    • pp.1833-1841
    • /
    • 2000
  • 생물학적 수처리공정의 생물막 (호기성 혹은 혐기성) 내의 생물막 두께 및 이온들의 농도구배등에 대한 모델링을 위하여 종래에 이론적으로만 접근하던 방법 대신, 실제로 생물막을 이동하며 측정하여 분석하는 첨단 연구 방법인 미소전극탐침을 제작하여 적용하였다. 미소전극 센서장치에서 가장 중요한 요소 중에 하나인 working 미소전극탐침은 생물막내의 전위차 (EMF, electromotive force)를 측정할 때 오염과 파손 등에 의해서 수명이 짧아지기 쉽기 때문에, 각각의 working 미소전극탐침의 제작방법에 대하여 논의하였으며, 제작된 pH와 $NO_3{^-}$ 미소전극탐침으로 탈질 미생물막 이온들의 농도를 막 깊이별로 측정하였다. 미소전극 센서장치에 의한 측정결과, 탈질 미생물막 내부에서의(생물막 표면에서 약 $350{\mu}m$) pH는 8.3 정도로 벌크용액상(bulk solution)의 pH 8보다 약간 상승하였으며, $NO_3{^-}$의 농도는 벌크용액상의 30 mg N/L농도에서 최종 4 mg N/L 청도로 나타났다.

  • PDF

Hybridization by an Electrical Force and Electrochemical Genome Detection Using an Indicator-free DNA on a Microelectrode-array DNA Chip

  • Choi, Yong-Sung;Lee, Kyung-Sup;Park, Dae-Hee
    • Bulletin of the Korean Chemical Society
    • /
    • 제26권3호
    • /
    • pp.379-383
    • /
    • 2005
  • This research aims to develop DNA chip array without an indicator. We fabricated microelectrode array by photolithography technology. Several DNA probes were immobilized on an electrode. Then, indicator-free target DNA was hybridized by an electrical force and measured electrochemically. Cyclic-voltammograms (CVs) showed a difference between DNA probe and mismatched DNA in an anodic peak. Immobilization of probe DNA and hybridization of target DNA could be confirmed by fluorescent. This indicator-free DNA chip microarray resulted in the sequence-specific detection of the target DNA quantitatively ranging from $10^{-18}\;M\;to\;10^{-5}$ M in the buffer solution. This indicator-free DNA chip resulted in a sequence-specific detection of the target DNA.

미소전극어레이형 DNA칩을 이용한 유전자다형의 전기화학적 검출 (Electrochemical Detection of Single Nucleotide Polymorphism (SNP) Using Microelectrode Array on a DNA Chip)

  • 최용성;권영수;박대희
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제53권5호
    • /
    • pp.286-292
    • /
    • 2004
  • In this study, an integrated microelectrode array was fabricated on glass slide using microfabrication technology. Probe DNAs consisting of mercaptohexyl moiety at their 5-end were spotted on the gold electrode using micropipette or DNA arrayer utilizing the affinity between gold and sulfur. Cyclic voltammetry in 5mM ferricyanide/ferrocyanide solution at 100 ㎷/s confirmed the immobilization of probe DNA on the gold electrodes. When several DNAs were detected electrochemically, there was a difference between target DNA and control DNA in the anodic peak current values. It was derived from specific binding of Hoechst 33258 to the double stranded DNA due to hybridization of target DNA. It suggested that this DNA chip could recognize the sequence specific genes. It suggested that multichannel electrochemical DNA microarray is useful to develop a portable device for clinical gene diagnostic System.

마이크로전극어레이형 바이오칩을 이용한 SNP의 검출 (Detection of SNP Using Microelectrode Array Biochip)

  • 최용성;권영수;박대희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 하계학술대회 논문집 Vol.5 No.2
    • /
    • pp.845-848
    • /
    • 2004
  • High throughput analysis using a DNA chip microarray is powerful tool in the post genome era. Less labor-intensive and lower cost-performance is required. Thus, this paper aims to develop the multi-channel type label-free DNA chip and detect SNP (Single nucleotide polymorphisms). At first, we fabricated a high integrated type DNA chip array by lithography technology. Various probe DNAs were immobilized on the microelectrode array. We succeeded to discriminate of DNA hybridization between target DNA and mismatched DNA on microarray after immobilization of a various probe DNA and hybridization of label-free target DNA on the electrodes simultaneously. This method is based on redox of an electrochemical ligand.

  • PDF

Indicator-free DNA Chip Array Using an Electrochemical System

  • Park, Yong-Sung;Kwon, Young-Soo;Park, Dae-Hee
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • 제4C권4호
    • /
    • pp.133-136
    • /
    • 2004
  • This research aims to develop a DNA chip array without an indicator. We fabricated a microelectrode array through photolithography technology. Several DNA probes were immobilized on an electrode. Then, target DNA was hybridized and measured electrochemically. Cyclic-voltammograms (CVs) showed a difference between the DNA probe and mismatched DNA in an anodic peak. This indicator-free DNA chip resulted in a sequence-specific detection of the target DNA.

Electrochemical Gene Detection Using Microelectrode Array on a DNA Chip

  • Park, Yong-Sung;Kwon, Young-Soo;Park, Dae-Hee
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • 제4C권4호
    • /
    • pp.145-148
    • /
    • 2004
  • In this study, a DNA chip with a microelectrode array was fabricated using microfabrication technology. Several probe DNAs consisting of mercaptohexyl moiety at their 5' end were immobilized on the gold electrodes by a DNA arrayer. Then target DNAs were hybridized and reacted with Hoechst 33258, which is a DNA minor groove binder and electrochemically active dye. Linear sweep voltammetry or cyclic voltammetry showed a difference between target DNA and control DNA in the anodic peak current values. It was derived from Hoechst 33258 and concentrated at the electrode surface through association with the formed hybrid. This suggested that this DNA chip could recognize the sequence specific genes.

반도체 미세전극을 이용한 말초 신경에서의 신경 신호 기록 (Neural Recordings Obtained from Peripheral Nerves Using Semiconductor Microelectrode)

  • 황은정;김성준;조하원;호우택
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1997년도 추계학술대회
    • /
    • pp.31-34
    • /
    • 1997
  • A semiconductor microelectrode array has been successfully used in obtaining single unit recordings from medial giant nerve of clay fish, rat saphenous nerve and abdominal ganglia of aplysia. The recording device fabricated using silicon microfabrication techniques is a depth-probe type and, previously, has been mostly used to record from central nerve system of vertebrates. From invertebrates, and also from peripheral nerves of vertebrates, however, the quality of the recorded signal depends heavily on the recording conditions, such as the proximity of the electrode site to the nerve cells and the size of the neuron. We have modeled the signal to noise ratio as unctions of these parameters and compared the experimental data with the calculated values thus obtained.

  • PDF