• 제목/요약/키워드: Micro-leakage

검색결과 153건 처리시간 0.021초

Delayed Progressive Extradural Pneumatocele due to Incomplete Sealing of Opened Mastoid Air Cell after Micro-Vascular Decompression

  • Hong, Ki-Sun;Park, Kwan
    • Journal of Korean Neurosurgical Society
    • /
    • 제47권6호
    • /
    • pp.477-479
    • /
    • 2010
  • A case of delayed progressive extradural pneumatocele after microvascular decompression (MVD) is presented. A 60-year-old male underwent MVD for hemifacial spasm; the mastoid air cell was opened and sealed with bone wax during surgery. One month after surgery, the patient complained of tinnitus, and progressive extradural pneumatoceles without cerebrospinal fluid (CSF) leakage was observed. Revision surgery was performed and the opened mastoid air cell was completely sealed with muscle patch and glue. The patient's symptoms were resolved, with no recurrence of pneumatoceles at 6 month follow up. Progressive extradural pneumatocele without CSF leakage after posterior fossa surgery is a very rare complication. Previous reports and surgical management of this rare complication are discussed.

선형 저밀도 폴리에틸렌과 에틸렌 비닐아세테이트의 혼합비에 따른 체적고유저항 특성 (The Volume Resistivity Properties due to Mixture ratio of Linear Low Density Polyethylene and Ethylene Vinyl Acetate)

  • 박정구;육영수;신현택;신종열;이충호
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1999년도 춘계학술대회 논문집
    • /
    • pp.552-555
    • /
    • 1999
  • In this paper, the volume resistivity properties due to mixture ration of linear low density polyethylene(LLDPE) and ethylene vinyl acetate(EVA) are studied. Electrodes is composed of upper electrode 37(mm $\Phi$), guardring electrode(inner 55(mm $\Phi$ ), and lower electrode 87(mm $\Phi$ In order to measure the leakage current, We used electrometer and stable oven with temperature controller. Measurement method is to measure the leakage current of next specimen after applying the voltage according to 'Step Apply Methods' for ten minutes. In order to measure the volume resistivity properties, the micro electrometer is used, the range of temperature and applying voltage are 25 to 100[$^{\circ}C$] to 100[V] respectively.

  • PDF

미세 가열기를 이용한 부분 가열 저온 Hermetic 패키징 (Low Temperature Hermetic Packaging by Localized Heating using Micro Heater)

  • 심영대
    • 한국마이크로전자및패키징학회:학술대회논문집
    • /
    • 한국마이크로전자및패키징학회 2002년도 추계기술심포지움논문집
    • /
    • pp.15-19
    • /
    • 2002
  • 기존 형상의 미세 가열기를 이용한 마이크로 시스템 패키징의 문제점을 해결하기 위해 새로운 형상의 미세 가열기를 제작하여 패키징 실험을 실시하였다. 기존 형상의 미세 가열기와 새로운 미세 가열기의 형상을 각각 제작하여 접합시에 미세 가열기에 발생하는 열분포를 IR 카메라를 이용하여 실험하였다. 기존 형상의 미세 가열기가 불균일하게 가열되는 반면, 새로운 형상의 미세 가열기는 매우 균일하게 가열되는 형상을 나타내었다. IR 카메라 실험을 바탕으로 접합 실험을 실시하였다. 접합 실험시 사용한 미세 가열기는 폭 50$\mu\textrm{m}$, 두께 2$\mu\textrm{m}$로 제작하였으며, 0.2 Mpa의 압력을 Pyrex glass cap에 가한 상태에서 150 mA의 전류를 공급함으로서 접합을 완료하였다. 접합이 완료된 시편들에 대해서 IPA를 통한 leakage 실험을 실시하였으며, 기존 형상의 미세 가열기를 이용한 시편들은 66%가 테스트를 통과한 반면 새로운 형상의 미세 가열기를 이용한 시편들은 85% 이상이 테스트를 통과하였다. Leakage 실험을 통과한 각각의 시편들에 대해서 접합력 측정을 실시한 결과, 기존 형상의 미세 가열기를 이용한 시편들은 15~21 Mpa의 접합력을 나타내었고, 새로운 형상의 미세 가열기를 이용한 시편들은 25~30 Mpa의 우수한 접합력을 나타내었다.

  • PDF

Surface Texturing에 의한 유압부품의 마찰저감 (Surface Texturing in Hydraulic Machine Components for Friction Reduction)

  • 박태조;김민규
    • 드라이브 ㆍ 컨트롤
    • /
    • 제13권1호
    • /
    • pp.27-33
    • /
    • 2016
  • In hydraulic machinery, the hydraulic fluid acts primarily as working fluid and secondarily as a lubricant. Hence, the viscous friction force acting on the sliding components should be reduced to improve the mechanical efficiency. It is now well known that the surface texturing is a useful method for friction reduction. In this study, using a commercial computational fluid dynamics (CFD) code, FLUENT, the lubrication characteristics of a surface textured slider bearing under high boundary pressure difference is studied. The streamlines, velocity profiles, pressure distributions, load capacity, friction force and leakage flowrate are highly affected by the film thickness ratio and the textured region. Partial texturing at the inlet region of the inclined slider bearing can reduce both friction force and leakage flowrate than in the untextured case. The present results can be used to improve the lubrication characteristics of hydraulic machinery.

이중으로 집중된 동적 미세 다엽콜리메이터의 선량학적 특성 평가 (Evaluation of Dosimetric Characteristics of a Double-focused Dynamic Micro-Multileaf Collimator (DMLC))

  • 김애란;서재혁;신헌주;박형욱;이기웅;이재춘;김신욱;김지나;박혜리;이희관;강영남
    • 한국의학물리학회지:의학물리
    • /
    • 제26권4호
    • /
    • pp.223-228
    • /
    • 2015
  • 이중으로 집중된 미세 다엽콜리메이터(Double-focused micro Multileaf Collimator: ${\mu}MLC$)는 보통의 다엽콜리메이터(Multileaf Collimator: MLC)에 비하여 조사면 가장자리 부분의 선량을 급격하게 줄여준다. 이러한 특성 때문에, 미세 다엽 콜리메이터는 정위적 방사선 수술과 치료(Stereotactic Radio-Surgery/RadioTtherapy, SRS/SRT)에 사용되어 왔다. 우리는 Elekta Synergy 선형가속기에 이중으로 집중된 동적 미세 다엽콜리메이터(Double-focused Dynamic micro-Multileaf Collimator: DMLC)를 부착하여 선량학적 특성을 평가하였다. 본 연구에서는, 필름(GafChromic EBT2 film), EDGE 다이오드 검출기, 3차원 물 팬텀을 이용하였다. 깊이선량백분율(Percent Depth Dose, PDD), 엽 투과도(leaf leakage), 반그림자(Penumbra)를 측정하였고, 모든 데이터들은 6MV 광자선으로 측정하였다. 그 결과, DMLC가 1% 이내의 투과도를 갖는것을 확인할 수 있었다. DMLC는 이중으로 집중 되는 구조를 가졌기 때문에 반 그림자가 조사야 크기에 대하여 독립적인 것을 확인하였다. 본 연구에서는 DMLC의 선량학적 특성을 바탕으로, Elekta Synergy에 부착된 DMLC의 적용 가능성을 증명하였다.

근관 밀폐도에 미치는 도말층 및 상아질 접착강화제의 영향 (EFFECTS OF SMEAR LAYER AND DENTIN PRIMERS ON THE SEALING ABILITY OF ROOT CANAL)

  • 양진석;황인남;김원재;오원만
    • Restorative Dentistry and Endodontics
    • /
    • 제25권4호
    • /
    • pp.527-535
    • /
    • 2000
  • The purpose of this study was to evaluate effects of smear layer and dentin primers on the sealing ability of root canals. 126 extracted human teeth with single, straight canals and mature apices were used. The Samples were first classified into six groups as follows: presence of smear layer; absence of smear layer; Scotchbond Bond Multi-Purpose; All Bond 2; Mac Bond 2; Clearfil Liner Bond 2. A Positive control was also established. All teeth except the control group were then obturated with thermoplasticized gutta-percha and AH26. Electrochemical and dye penetration technique were later used to evaluate the degree of micro leakage through the root canal. Seventy teeth were then immersed in a 1% potassium chloride solution and An external power supply(DC 10 V) was then applied to the circuit for the electrochemical microleakage test. The degree of Microleakage was determined over period of 28 days before being evaluated. In total, 48 teeth were submitted to the dye infiltration technique. All specimen were suspended in 2% methylene blue dye for 1 week before being longitudinally split. The degree of dye infiltration was measured under a stereo microscope at ${\times}10$ magnification and evaluated. The results were as follows: 1. Apical microleakage increased throughout the test period in all group and one group having a smear layer showed a dramatic increase under electrochemical test (p<0.05). In the group having smear layer, the degree of apical microleakage was the highest, and the micro leakage was much higher than in the smear layer removed group in electrochemical test (p<0.05). Scotchbond Multi-Purpose, All Bond 2, Mac Bond 2 and Clearfil Liner Bond 2 showed lower micro leakage than one group having smear layer. The All Bond 2 and Clearfil Liner Bond 2 treated groups showed the lowest microleakage in electrochemical test (p<0.05). 2. There was no significant difference between the experimental groups in dye penetration technique. These results suggested that the removal of the smear layer from root canal and concomitantly the application of dentin primer into root canal could improve the sealing ability of root canal obturation.

  • PDF

초미세 발포 사출 성형품의 단열 특성 (The Insulation Property of Microcellular Injection Molding Plastics)

  • 이정현;홍순국;김지현;윤재동
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집C
    • /
    • pp.263-268
    • /
    • 2001
  • MCPs means Micro Cellular Plastics. The micro-cells are generated in the products by the difference of dissolution through the pressure drop after super critical fluid of CO2 or N2 dissolves into polymer. We have developed injection molding process adopting MCPs and applied it to a broad range of injection molded thermoplastic materials and applications. It can prevent the leakage of impact strength and increase the thermal conductivity, moreover regulate the thermal conductivity. Then we can develop the high strength foaming plastics. Also, it can be gained a competitive advantage by utilizing its processing benefits, e.g. the lightweight products and significant reductions in material consumption.

  • PDF

AlN 압전 진동형 마이크로 에너지 하베스터 설계 및 분석 (Design and Analysis of AlN Piezoelectric Micro Energy Harvester Based on Vibration)

  • 이병철;정귀상
    • 한국전기전자재료학회논문지
    • /
    • 제23권5호
    • /
    • pp.424-428
    • /
    • 2010
  • This paper describes the design and analysis of AlN piezoelectric micro energy harvester. The harvester was designed to convert ambient vibration energy to electrical power as a AlN piezoelectric material compatible with CMOS (complementary metal oxide semiconductor) process. To cut off the leakage current, AlN was used as the insulating layer. Also, Mo was used for the excellent c-axis crystal growth as the bottom electrode. The AlN harvester which it has the low operating frequency was designed by using the ANSYS FEA (finite element analysis). From the simulation results, the resonance frequency of designed model is about 360 Hz and analyzed the bending mode, displacement and expectation output.

내부그라우팅으로 미세균열이 보수된 철근콘크리트 시공이음부의 역학적 특성에 관한 연구 (Mechanical Behavior of Construction Joints in Reinforced Concrete Structures Filled Internally with Cement Pastes)

  • 오병환;김세훈;이근희
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제7권1호
    • /
    • pp.217-225
    • /
    • 2003
  • Grouting internally with grout materials can repair the micro-cracks and micro-voids of construction joints more efficiently than injecting grouts from the surface of cracks. A new internal grouting method using perforated bundled-cables was developed in this study to enhance the structural integrity of the construction joints. The extensive experiments were performed to examine the mechanical behavior of construction joints which are repaired internally by the developed method. The tests were conducted for rectangular-shaped box wall structures and straight wall structures. The strength and permeability tests at grouted construction joints were conducted to evaluate the structural behavior of repaired construction joints. The present study indicates that the internal grouting method developed in this study enhances greatly the performance of construction joints and may be efficiently used for the leak-tight integrity of construction joints in concrete structures.

뇌서지전류와 Ageing에 의한 산화아연형 피뢰기 소자의 미세구조변화 (Change of the Microstructure of ZnO Arrester block by Lightning Surge Current and Ageing test)

  • 이복희;강성만
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.1877-1879
    • /
    • 2000
  • This paper deals with the change of the micro-structure of ZnO associated with lightning surge current and ageing test. In this work, a surge current generator which can produce 8/20 [${\mu}s$], 6 [kA] impulse current is designed and fabricated to simulate the lightning impulse current. The residual voltage and leakage current flowing to ZnO blocks are observed. Also a compensation circuit was used in resistive current measurement. The micro-structures of ZnO arrester block were significantly changed by lightning surge current and accelerated temperature ageing test.

  • PDF