• Title/Summary/Keyword: Micro-HPLC

Search Result 46, Processing Time 0.027 seconds

Oxidations product of ${\alpha}-,\;{\gamma}-tocopherol$ and ${\gamma}-tocotrienol$ (${\alpha}-,\;{\gamma}-Tocopherol$${\gamma}-tocotrienol$의 산화 생성물)

  • Lee, Hyung-Ok
    • Applied Biological Chemistry
    • /
    • v.36 no.1
    • /
    • pp.33-37
    • /
    • 1993
  • Oxidations products of ${\alpha}-tocopherol$, ${\gamma}-tocopherol$ and ${\gamma}-tocotrienol$ in lipophilic reaction media were studied. ${\alpha}-Tocopherylquinone$, ${\gamma}-tocopherylquinone$ and ${\gamma}-tocotrienylquinone$ were fractionated using micro column, isolated and identified by HPLC and MS.

  • PDF

Characterization of a novel methionine sulfoxide reductase A from tomato (Solanum lycopersicum), and its protecting role in Escherichia coli

  • Dai, Changbo;Singh, Naresh Kumar;Park, Myung-Ho
    • BMB Reports
    • /
    • v.44 no.12
    • /
    • pp.805-810
    • /
    • 2011
  • Methionine sulfoxide reductase A (MSRA) is a ubiquitous enzyme that has been demonstrated to reduce the S enantiomer of methionine sulfoxide (MetSO) to methionine (Met) and can protect cells against oxidative damage. In this study, we isolated a novel MSRA (SlMSRA2) from Micro-Tom (Solanum lycopersicum L. cv. Micro-Tom) and characterized it by subcloning the coding sequence into a pET expression system. Purified recombinant protein was assayed by HPLC after expression and refolding. This analysis revealed the absolute specificity for methionine-S-sulfoxide and the enzyme was able to convert both free and protein-bound MetSO to Met in the presence of DTT. In addition, the optimal pH, appropriate temperature, and $K_m$ and $K_{cat}$ values for MSRA2 were observed as 8.5, $25^{\circ}C$, $352{\pm}25\;{\mu}M$, and $0.066{\pm}0.009\;S^{-1}$, respectively. Disk inhibition and growth rate assays indicated that SlMSRA2 may play an essential function in protecting E. coli against oxidative damage.

MICRO INJECTOR BASED ON DIGITAL DRIVE AND CONTROL FOR BIOMEDICAL ENGINEERING

  • Hou, Liya;Zhang, Weiyi;Mu, Lili;Zhu, Li
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.2349-2351
    • /
    • 2003
  • This paper reports a novel microfluidic system, by which microfluidic delivery, transport and control can be digitally realized in femtoliter scale. Microelectronic grade $N_2$ from a pressurized canister was passed through HPLC tubing into a micro injector. The micro injector was driven and controlled digitally by the control system that can apply various control parameters such as pulse frequencies. A front-end of micro nozzle was inserted the dyed oil to collect droplets injected. The diameter of a droplet was measured by a microscope and a CCD camera, and then its volume can be calculated on the assumption that the droplet is spherical. The micro nozzles were simply pulled in glass capillary tubes by the micro puller self-made, and the geometry parameters of the micro nozzles can be adjusted easily. Experiments have successfully been carried out, and the results demonstrated that the proposed digital micro injector possesses three significant advantages : precise ultra-small liquid volume in femtoliter scale, digital microfluidic control and micro devices fabricated by simple glass process, not based on IC process.

  • PDF

Simple and Sensitive Determination of Baclofen in Human Plasma by Column-Switching and Semi-Micro High-Performance Liquid Chromatography

  • Ban, Eun-Mi;Ko, Hye-Ran;Kim, Chong-Kook
    • Proceedings of the PSK Conference
    • /
    • 2003.04a
    • /
    • pp.284.2-284.2
    • /
    • 2003
  • Using a column-switching technique. highly sensitive and selective semi-micro high-performance liquid chromatographic (HPLC) method has been developed for the determination of baclofen in human plasma. Following precipitation of plasma sample containing baclofen with zinc sulfate-acetonitrile, samples were directly injected on to the system. (omitted)

  • PDF

울산지역 폐수 중 프탈레이트 에스테르 및 비스페놀 A의 HPLC 분석

  • Han, Yeong-Ju;Park, Jin-Do;Lee, Hak-Seong
    • Proceedings of the Korean Environmental Sciences Society Conference
    • /
    • 2008.11a
    • /
    • pp.272-274
    • /
    • 2008
  • 일반적으로 프탈레이트 에스테르의 전처리방법에는 액액추출법(Liquid Liquid Extraction, LLE), 고상추출법(Solid Phase Extraction, SPE), 고상미세추출법(Solid Phase Micro Extraction, SPME) 등의 분석방법이 있다. 그 중에서 본 연구에서는 간편하고 정확성이 높은 SPE를 이용하였으며, 적은 양의 유기용제를 사용하여 전처리함으로써 2차적인 환경 오염을 줄일 수 있다는 점에서 다른 전처리 방법보다 유용하다고 할 수 있다. 또한 프탈레이트 에스테르의 경우는 구조적으로 안정적인 편이나 페놀류의 경우 hydroxy group 때문에 GC/MS 분석시 유도체화 과정이 필수적이나 이번 연구에서는 HPLC를 이용하므로 별도의 유도체화의 번거로움 없이 바로 분석할 수 있는 이점이 있다. 더 많은 연구가 필요하겠지만 앞서서의 결과에서도 알 수 있듯이 전반적으로 검출한계가 0.1$\sim$0.5$\mu$g/L 정도로 높고, 82% 이상의 양호한 회수율을 나타낸 것으로 미루어 보아 극미량 분석이 아닌 이상, 산업체에서 HPLC의 이용이 더욱 유리할 것이라고 사료된다.

  • PDF

PYE [2-(1-pyrenyl)ethyldimethylsilylated silica] Column HPLC and HR-GC-(micro) ECD in the Accurate Determination of Toxic Co-planar PCBs and Polybrominated Diphenyl Ethers (PBDEs)

  • Kannan, Narayanan;Hong, Sang-Hee;Oh, Jae-Ryoung;Yim, Un-Hyuk;Li, Donghao;Shim, Won-Joon
    • Bulletin of the Korean Chemical Society
    • /
    • v.26 no.4
    • /
    • pp.529-536
    • /
    • 2005
  • Measurement of toxicologically relevant polychlorinated biphenyl (PCB) congeners such as non-ortho(IUPAC#) 77, 81, 126, 169 and mono-ortho 105, 114, 118, 123, 156, 157, 189 and di-ortho 170, 180 and polybrominated diphenyl ethers (PBDEs) such as 47, 66, 85, 99, 100, 138, 153, 154 in environmental samples become almost mandatory in several countries now. However, most of the available methods involve expensive instrumentations such as HRGC-HRMS or ECNI-LRMS, apart from expensive extraction and clean-up (with large volume of solvents) steps. A method has been devised combining the analytical separation power of PYE [2-(1-pyrenyl)ethyldimethysilylated silica] column HPLC and high-resolution gas chromatographic techniques including micro-electron capture detection (ECD) and two dimensional gas chromatograpy-ECD techniques to determine these eco-toxic substances at parts-per-trillion (ppt) levels. This combination resolves co-elution of congeners that occur in disproportionate ratios (e.g. CB-110 and -77) and allows accurate congener-specific determination of target compounds. This method is cost effective as it requires only hexane, that in small quantities (10 mL) and GC-ECD. The elution and analysis time are optimized to less man hours. This method is effectively utilized in the analysis of co-planar PCBs and PBDEs from archived solvent extracts of samples previously analyzed for pesticides and PCBs. Structure based separation of contaminant classes improves GCECD determination at ppt levels.

Detection of tetracyclines in beef and pork (식육중 테트라사이클린계 항생물질 잔류조사)

  • 박재명;최해연;이은정;조우영;조부제;정운선
    • Korean Journal of Veterinary Service
    • /
    • v.20 no.2
    • /
    • pp.225-233
    • /
    • 1997
  • In an effort to Improve the quality of meat and to monitor farms, residual tetracyclines in local beef and pork produced in the province of North Chung-cheong were determined by a EEC 4-plate, Charm II and HPLC, respectively. The results were summarized as follows ; 1. Of the 547 samples, 4 beef and 13 pork samples were judged to be positive by EEC 4 - plate method. 2. Detection rates of tetracyclines by type 1(++--) and type 2(+++ or ++$\pm$-) micro-bial growth Inhibition In EEC 4-plate method were 100% and 71%, respectively. 3. Of 17 positive samples, 6 were positive for tetracyclines, 4 were positive for tetracyclines and sulfonamides, 1 was positive for sulfonamides, and 2 were positive for others by Charm II test. 4. The best eluents were 0.01M methanolic oxalic acid, and the ideal temperature for stable concentration was $40^{\circ}C$ as optimal HPLC analytical conditions for the detection of tetracy-clines. 5. Of the 10 positive samples for tetracyclines by Charm II test, tetracyclines were confirmed in 2 beef and 6 pork samples, using HPLC, at levels ranging from 3.64~4.22 ppm and 0.2~1.20 ppm, respectively.

  • PDF

Studies on the Constituents of Korean Edible Oils and Fats - Part 5 : Analysis of Fatty acids in sesame and perilla oil by High Performance Liquid Chromatography (한국산 식물식용유지의 성분에 관한 연구 - 제 5 보- : -High Performance Liquid Chromatography에 의한 참깨와 들깨종자중의 지방산 분석 -)

  • Hwang, Sung-Za;Ko, Young-Su
    • Journal of Nutrition and Health
    • /
    • v.15 no.1
    • /
    • pp.15-21
    • /
    • 1982
  • In this work, the quantitative estimation of fatty acids in sesame and perilla oil by high performance liquid chromatography (HPLC) was investigated. The analysis of fatty acids were separated by HPLC using a differential refractometer as a detector. With micro Bondapak $C_{18}FFAA$ column and acetonitril, chloroform and tetrahydrofuran mixture as a solvent. In the fatty acid compositions, sesame oil was composed mainly of linoleic and oleic acids 49.6 % and 34.7%. In perilla oil, the amounts of oleic, linoleic and linolenic acids were 13.6%, 14.5% and 63.8%, respectively.

  • PDF

Synthesis and Small Animal Brain PET Study of a Serotonin Receptor Radiotracer, 18F-Mefway (세로토닌 5-HT1A수용체 방사성 추적자 18F-Mefway의 합성과 소동물 뇌 PET 연구)

  • Ahn, Sung-Min;Hong, Tae-Kee;Ryu, Young-Hoon;Choi, Jae-Yong;Kim, Sung-Chul
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.11
    • /
    • pp.262-270
    • /
    • 2009
  • $^{18}F$-mefway has been developed as radioligand for serotonin receptor 5-$HT_{1A}$. The object of this study was to obtain the mefway precursor with the higher yield than previous method and to identify whether $^{18}F$-mefway can bind to 5-$HT_{1A}$ or not. from microPET imaging of small animal brain. Precursor was prepared by a modification of the reported procedure then [$^{18}F$] labeling was performed by adding $^{18}F$ ion at $130^{\circ}C$ in the hot cell for 30min. After purification of reaction mixture using alumina Sep-pak and HPLC, microPET images of small animal brain were determined. The chemical yield of precursor was increased from 9% to 34% using oxalyl chloride and LAH/diethylether. We synthesized a precursor which was successfully labeled with no-carrier-added $^{18}F$-by new synthetic route. This research suggest that $^{18}F$-mefway will be used a radiopharmaceutical for evaluation of central nerve system disorder as imaging a gent for 5-$HT_{1A}$ receptor.