• Title/Summary/Keyword: Micro channel

검색결과 612건 처리시간 0.029초

코드를 이용한 초음파 동시구동 시스템 (Simultaneous Driving System of Ultrasonic Sensors Using Codes)

  • 김춘승;최병준;이상룡;이연정
    • 제어로봇시스템학회논문지
    • /
    • 제10권11호
    • /
    • pp.1028-1036
    • /
    • 2004
  • Ultrasonic sensors are widely used in mobile robot applications to recognize external environments by virtue that they are cheap, easy to use, and robust under varying lighting conditions. In most cases, a single ultrasonic sensor is used to measure the distance to an object based on time-of-flight (TOF) information, whereas multiple sensors are used to recognize the shape of an object, such as a comer, plane, or edge. However, the conventional sequential driving technique involves a long measurement time. This problem can be resolved by pulse coding of ultrasonic signals, which allows multi-sensors to be emitted simultaneously and adjacent objects to be distinguished. Accordingly, this paper presents a new simultaneous coded driving system for an ultrasonic sensor array for object recognition in autonomous mobile robots. The proposed system is designed and implemented. A micro-controller unit is implemented using a DSP, Polaroid 6500 ranging modules are modified for firing the coded signals, and a 5-channel coded signal generating board is made using a FPGA. To verify the proposed method, experiments were conducted in an environment with overlapping signals, and the flight distances fur each sensor were obtained from the received overlapping signals using correlations and conversion to a bipolar PCM-NRZ signal.

하수처리수 방류구의 거품발생 원인진단 및 저감방안: 국내 하수처리장 사례를 중심으로 (Cause Diagnosis and Reduction Measures of Foaming in the Treated Wastewater Outlet of D Wastewater Treatment Plant)

  • 신재기;조영수;김영성;황순진
    • 생태와환경
    • /
    • 제49권2호
    • /
    • pp.124-129
    • /
    • 2016
  • 본 연구는 하수처리장에서 최종 방류되는 하수처리수의 거품발생 원인분석과 저감방안을 제시하고자 수행되었다. 감조하천의 방류구에서 거품이 발생하는 것은 구조적인 문제점으로 파악되었다. 거품은 낙차에 의한 공기 연행과 확산방지막에 의한 내부축적이 주요한 원인이었다. 이러한 여건을 고려하여, 방류수로와 방류구 종단에서 미세스크린과 수중방류를 통해 거품발생을 완화시킬 수 있는 효과적인 방안을 제시하였다.

균일 냉각을 고려한 Thick-Wall 형상의 플라스틱 렌즈 쾌속 금형 제작 (Manufacturing of Rapid Tooling for Thick-Wall Plastic Lens Mold with Conformal Cooling Channel)

  • 박형필;차백순;이상용;최재혁;이병옥
    • Design & Manufacturing
    • /
    • 제1권1호
    • /
    • pp.27-32
    • /
    • 2007
  • In the optical application demand for high quality lens is increasing. Plastics lenses are demanded more than glass lenses for large size lenses as well as micro-size lenses. It is difficult to apply typical straight cooling channels of injection mold to lens molding due to its non-uniform temperature distribution. In this study, we manufactured molds for plastic lenses with the conventional cooling channels and conformal cooling channels produced by the DMLS process. We evaluated cooling performance for the 2 molds by injection molding experiment. Also, uniformity of the temperature distribution was tested by infrared camera and temperature monitoring. We confirmed that the cooling performance and temperature uniformity with the conformal cooling channels is much improved from the ones with the conventional. The cooling time with the conformal cooling channels was reduced 30% compared with the conventional cooling channels.

  • PDF

공압식 미세밸브를 이용한 다중유체 배열장치 개발 (Development of Multi Sample Array System Based on Pneumatic Valve)

  • 김철민;박서정;김규만
    • 한국정밀공학회지
    • /
    • 제34권1호
    • /
    • pp.59-63
    • /
    • 2017
  • We present a multi-sample array device based on a pneumatic system. Solenoid valves were used to control a micro valve in a pneumatic system. The use of a compressor together with a vacuum pump ensured that one outlet could supply both compression and vacuum pressure. The multi-sample array device was fabricated using conventional photolithography and PDMS casting. The device was composed of a multiplexer, sample array, and rinsing. The multiplexer could control four sample solutions injecting into the sample array chamber. Sample solution not arrayed was removed by DI-water from the rinsing inlet. To prevent trapping of microbubbles in the channel during injection of sample solution into the device, surfactant was added in PDMS solution to serve as a hydrophilic surface treatment. As a result, the device could be used as a sample array for 64 cases, using four samples and three columns of three chambers.

미소블록에 의한 교차 회전유동과 미소유로에 의한 박층유동을 이용한 정적 혼돈 미소유체 혼합기에 관한 연구 (Static Chaos Microfluid Mixers Using Alternating Whirls and Laminations)

  • 장성환;조영호
    • 대한기계학회논문집B
    • /
    • 제28권12호
    • /
    • pp.1549-1556
    • /
    • 2004
  • We have deigned, fabricated and compared four different types of static chaos microfluid mixers, including the mixers using straight channel flow, microblock-induced alternating whirl flow, microchannel-induced lamination flow, and combined alternating whirl-lamination flow. Among them, the alternating whirl-lamination (AWL-type) mixer, composed of 3-D rotationally arranged microblocks and dividing microchannels fabricated by conventional planar lithography process, is effective to reduce the mixing length over wide flow rate ranges. We characterize the performance of the fabricated mixers, through the flow visualization technique using phenolphthalein solution. We verify that the AWL-type microfluid mixer shows the shortest fluid mixing length of 2.8mm∼5.8mm for the flow rate range of Re=0.26∼26 with the pressure drop lower than 5kPa. Compared to the previous mixers, requiring the mixing lengths of 7∼17mm, the AWL-type microfluid mixer results in the 60% reduction of the mixing lengths. Due to the reduced mixing lengths within reasonable pressure drop ranges, the present micromixers have potentials for use in the miniaturized Micro-Total-Analysis-Systems($\mu$TAS).

The Effect of Bribery on Firm Innovation: An Analysis of Small and Medium Firms in Vietnam

  • NGUYEN, Toan Ngoc
    • The Journal of Asian Finance, Economics and Business
    • /
    • 제7권5호
    • /
    • pp.259-268
    • /
    • 2020
  • This study aims to provide empirical evidence on the causal relationship between bribery and firm innovation. To this end, we use a micro-dataset of small and medium firms in Vietnam surveyed in 2015. Given the binary nature of the dependent variable, a simple probit regression model is employed. However, as bribery variable is potentially endogenous, a simple probit regression may give biased estimates. We deal with the potential endogeneity by making use of the bivariate probit model. A property of the bivariate probit model is that it can produce efficient estimates of a typical probit model with endogenous binary explanatory variable. A Hausman-like likelihood ratio test is implemented following the estimation to test the existence of endogeneity. We find that bribery significantly undermines firm innovation. Also, firms run by household appear less innovative. The probability of innovation diminishes significantly if firm owners or managers have previous experience in firm products. As expected, larger firms seem to be more innovative. Exporters tend to be more innovative compared to non-exporters. Our findings provide support to the hypothesis that bribery is detrimental to firm innovation and, thus, innovation may be a mediating channel, through which, bribery impedes firm long-term performance.

Transient microfluidic approach to the investigation of erythrocyte aggregation: comparison and validation of the method

  • Hou, Jian-Xun;Shin, Se-Hyun
    • Korea-Australia Rheology Journal
    • /
    • 제20권4호
    • /
    • pp.253-260
    • /
    • 2008
  • A method based on transient shear flow dynamics of red cell aggregates was developed to investigate reversible re-aggregation processes with decreasing shear flow. In the microchannel-flow aggregometry, the aggregated red blood cells that are subjected to continuously decreasing shear stress in microchannel flow were measured with the use of a laser-scattering technique. Both the laser-backscattered intensity and pressure were simultaneously measured with respect to time, resulting in shear stress ranging from $0{\sim}35\;Pa$ for a time period of less than 30 seconds. The time dependent recording of the backscattered light intensity (syllectogram) yielded an upward convex curve with a peak point, which reflected the transition threshold of aggregation in the RBC suspensions. Critical-time and critical-shear stress corresponding to the peak point were examined by varying the initial pressure-differential and the micro channel depth, and these results showed good potential for being used as new aggregation indices. In the present study, these newly proposed indices were also validated by differentiating the effect of fibrinogen on RBC aggregation and then these indices were compared to the conventional indices that were measured by a rotational aggregometer.

선택적 분자선 에픽택시 방법에 의한 1D-2DEG 혼성 나노선 FET의 구현 (Realization of 1D-2DEG Composite Nanowire FET by Selective Area Molecular Beam Epitaxy)

  • 김윤주;김동호;김은홍;서유정;노정현;한철구;;김태근
    • 한국전기전자재료학회논문지
    • /
    • 제19권11호
    • /
    • pp.1005-1009
    • /
    • 2006
  • High quality three-dimensional (3D) heterostructures were constructed by selective area (SA) molecular beam epitaxy (MBE) using a specially patterned GaAs (001) substrate to improve the efficiency of tarrier transport. MBE growth parameters such as substrate temperature, V/III ratio, growth ratio, group V sources (As2, As4) were varied to calibrate the selective area growth conditions and the 3D GaAs-AlGaAs heterostructures were fabricated into the ridge type and the V-groove type. Scanning micro-photoluminescence $({\mu}-PL)$ measurements and the following analysis revealed that the gradually (adiabatically) coupled 1D-2DEG (electron gas) field effect transistor (FET) system was successfully realized. These 3D-heterostructures are expected to be useful for the realization of high-performance mesoscopic electronic devices and circuits since it makes it possible to form direct ohmic contact onto the (quasi) 1D electron channel.

Two-step Holographic Imaging Method based on Single-pixel Compressive Imaging

  • Li, Jun;Li, Yaqing;Wang, Yuping;Li, Ke;Li, Rong;Li, Jiaosheng;Pan, Yangyang
    • Journal of the Optical Society of Korea
    • /
    • 제18권2호
    • /
    • pp.146-150
    • /
    • 2014
  • We propose an experimental holographic imaging scheme combining compressive sensing (CS) theory with digital holography in phase-shifting conditions. We use the Mach-Zehnder interferometer for hologram formation, and apply the compressive sensing (CS) approach to the holography acquisition process. Through projecting the hologram pattern into a digital micro-mirror device (DMD), finally we will acquire the compressive sensing measurements using a photodiode. After receiving the data of two holograms via conventional communication channel, we reconstruct the original object using certain signal recovery algorithms of CS theory and hologram reconstruction techniques, which demonstrated the feasibility of the proposed method.

경혈 저항특성에 관한 연구(II) (A Study on the Acupuncture Point Resistance Characteristics(II))

  • 김응수;한순천;최태종;김정국;허웅;박영배
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2001년도 하계종합학술대회 논문집(5)
    • /
    • pp.69-72
    • /
    • 2001
  • In this paper, we study about a acupuncture point and a non-acupuncture point resistance characteristics for acupuncture research. For this study, we devised resistance variation measurement system. This system is consist of 4-channel skin resistance measuring parts, filters, 12bit A/D convertor, 8051 micro-controller, and personal computer The developed system insert a low current to skin and obtains voltages from standard resistor that is convected to measurement circuit in series. The obtained voltage is converted to 12bit digital signal. Therefore the converted signal is changed to skin resistance by calculation in the personal computer. As the results of experiment, the resistance of acupuncture point and non-acupuncture point are different from each other. The acupuncture point has very fast current flows than the other non- acupuncture point.

  • PDF