• 제목/요약/키워드: Micro Degree

검색결과 404건 처리시간 0.052초

소 혈액의 45도 경사 모세관에 의한 ESR측정에 있어서 환경온도 및 PCV에 상관하는 관계적 예기ESR치 (Relative Anticipated Erythrocyte Sedimentation Rate of Cattle Blood, as Measured by 45 Degree-Angled Capillary Hematocrit Tube, for Ambient Temperature and PCV Value)

  • 이방환
    • 대한수의학회지
    • /
    • 제27권2호
    • /
    • pp.339-345
    • /
    • 1987
  • Each of twenty blood samples taken from apparently healthy Korean Cows was used to produce five different mixtures of autologous plasma and blood corpuscles such that their values of packed cell volume (PCV) lay between 10 to 50ml/l00ml. The measurements of erythrocyte sedimentation rate (ESR) using 45 degree-angled capillary hematocrit tube, 1.1-1.2mm bore, ($45^{\circ}-micro-ESR$) were practised for the blood of various levels of PCV under the ambient temperature of ${10^{\circ}C}$, ${20^{\circ}C}$ and ${30^{\circ}C}$. Correlation of ESR to ambient temperature showed linear regression each in five levels of PCV. ESR increased with ascending ambient temperature, and magnitude of the increase of ESR became greater as the level of PCV lowered. Correlation of ESR, of which values were transformed by the linear regression equation correlated to ambient temperature to PCV showed curvilinear regression each in three levels of ambient temperature, and ESR was increased with decreasing PCV. The data were statistically analysed and a list of relative anticipate $45^{\circ}-micro-ESR$ values for PCV and ambient temperature was presented.

  • PDF

플라즈마 제트에서의 분말 용융특성에 따른 Y2O3 코팅층의 미세조직 형성거동 (Effects of Powder Melting Degree on Microstructural Features of Plasma Sprayed Y2O3 Coating)

  • 강상운;백경호
    • 한국재료학회지
    • /
    • 제26권5호
    • /
    • pp.229-234
    • /
    • 2016
  • In this study, the degree of particle melting in $Y_2O_3$ plasma spraying and its effects on coating characteristics have been investigated in terms of microstructural features, microhardness and scratch resistance. Plasma sprayed $Y_2O_3$ coatings were formed using two different powder feeding systems: a system in which the powder is fed inside the plasma gun and a system in which the powder is fed externally. The internal powder spraying method generated a well-defined lamellae structure that was characterized by a thin porous layer at the splat boundary and microcracks within individual splats. Such micro-defects were generated by the large thermal contraction of splats from fully-molten droplets. The external powder spraying method formed a relatively dense coating with a particulate deposition mode, and the deposition of a higher fraction of partially-melted droplets led to a much reduced number of inter-splat pores and intra-splat microcracks. The microhardness and scratch resistance of the $Y_2O_3$ coatings were improved by external powder spraying; this result was mainly attributed to the reduced number of micro-defects.

CNC 공작기계 스핀들 유닛의 5자유도 열변형 오차측정 및 모델링 기술 (Thermal Error Measurement and Modeling Techniques for the 5 Degree of Freedom(DOF) Spindle Unit Drifts in CNC Machine Tools)

  • 박희재;이석원;권혁동
    • 대한기계학회논문집A
    • /
    • 제24권5호
    • /
    • pp.1343-1351
    • /
    • 2000
  • Thermally induced errors have been significant factors affecting the machine tool accuracy. In this paper, the spindle thermal error has been focused, where the 5 degree of freedom thermal error components are considered. An effective measurement system has been devised for the 5 DOF thermal errors, consisting of gap sensors and thermocouples around the micro-computer interfaced environment. Several thermal error modeling techniques are also implemented for the thermal error prediction: multiple linear regression, neural network and system identification methods, etc. The performance of the thermal error modeling techniques is evaluated and compared, giving the system identification method as the optimum model having the least deviation. The developed system for the thermal error measurement and modeling was practically applied to a CNC machining center, and the spindle thermal errors were effectively compensated around the micro computer-machine tool interfaced networks. The machine tool accuracy was improved about 4-5 times typically.

모세관법을 이용한 나노 복합재료 마이크로 구조 제작 (Fabrication of Microstructures with Nanocomposites by Capillary Effect)

  • 한수호;황희윤
    • Composites Research
    • /
    • 제31권4호
    • /
    • pp.171-176
    • /
    • 2018
  • 인공 건식 접착 구조를 위한 새로운 마이크로-나노 계층구조 제작기법을 제안하였으며, 모세관법을 활용한 마이크로 구조 내 나노 소재 정렬에 대한 기초 연구를 수행하였다. 다중 벽 탄소나노튜브(MWCNT)와 폴리디메틸실록산(PDMS) 혼합물의 제작 조건에 따른 경화도 및 점도 특성을 분석하고, 이로부터 몇 가지 제작 조건을 결정하였다. MWCNT-PDMS 마이크로 구조 제작 후 단면 분석을 통해 PDMS내 MWCNT의 정렬 특성을 분석한 결과, 제작 온도와 상대 경화도가 낮을 경우 MWCNT의 정렬도가 우수하며, 단위 면적당 MWCNT의 밀도는 제작 온도나 상대 경화도에 영향을 적게 받는 것으로 확인되었다.

초소형 고집적 모바일 커넥터부품 구조해석 (Structural Analysis of High-Density Mobile Micro-Connector)

  • 전용준;신광호;허영무
    • Design & Manufacturing
    • /
    • 제9권2호
    • /
    • pp.1-5
    • /
    • 2015
  • Recently, as small-sized display products such as mobile phones and digital cameras have become lighter and smaller, the size of electric signal delivery part, connector for the mobile display products, also, needs to become smaller, so high-density integration like shortening the distance between signal delivery media, conductors is necessary. With the micro and high-density integration of the connector, it is necessary to maintain contact to a certain degree for keeping intensity and delivering electric signal smoothly to prevent a defect with a specific impact. Accordingly, this study carried out a structural analysis according to the operating mechanisms of 0.16CHP Class Bottom Contact FPC Connector and 0.24CHP Class BTB Connector mostly used in small-sized mobile display products such as mobile phones and digital cameras. As a result of the analysis, both connectors had lower than 997MPa, yield strength of connector material C5240-XSH, so it is judged that permanent plastic deformation would not occur, and that a contact force between the connector and FPC film occurs to a certain degree, so that there would not be any defect in electric signal delivery.

  • PDF

6자유도를 갖는 정밀 위치제어용 병렬 매니퓰레이터의 기구학 해석 (Kinematic analysis of a 6-degree-of-freedom micro-positioning parallel manipulator)

  • 박주연;심재홍;권동수
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1996년도 한국자동제어학술회의논문집(국내학술편); 포항공과대학교, 포항; 24-26 Oct. 1996
    • /
    • pp.213-216
    • /
    • 1996
  • This paper studies a class of in-parallel manipulators with special geometry where the forward displacement analysis problem can be solved easier than the fully parallel manipulators. Three horizontal links of this mechanism provide 3DOFs(Degrees of Freedom), which are one degree of orientational freedom and two degrees of translatory freedom. Three vertical links of this mechanism provide 3DOFs, which are two degrees of orientational freedom and one degree of translatory freedom. The main advantages of this manipulator, compared with the Stewart platform type, are the capability to produce pure rotation and to predict the motion of the moving platform easily. Since this manipulator has simple kinematic characteristics compared with the Stewart platform, controlling in real-time is possible due to less computational burden. The purpose of this investigation is to develope an analytical method and systematic method to analyze the basic kinematics of the manipulator. The basic kinematic equations of the manipulator are derived and simulation is carried out to show the performance of the mechanism.

  • PDF

SOI웨이퍼를 이용한 마이크로가속도계 센서의 열응력해석(I) (Analyses Thermal Stresses for Microaccelerometer Sensors using SOI Wafer(I))

  • 김옥삼
    • 동력기계공학회지
    • /
    • 제5권2호
    • /
    • pp.36-42
    • /
    • 2001
  • This paper deals with finite element analyses of residual stresses causing popping up which are induced in micromachining processes of a microaccelerometer sensors. The paddle of the micro accelerometer sensor is designed symmetric with respect to the direction of the beam. After heating the tunnel gap up to 100 degree and get it through the cooling process and the additional beam up to 80 degree and get it through the cooling process. We learn the thermal internal stresses of each shape and compare the results with each other, after heating the tunnel gap up to 400 degree during the Pt deposition process. Finally we find the optimal shape which is able to minimize the internal stresses of microaccelerometer sensor. We want to seek after the real cause of this pop up phenomenon and diminish this by change manufacturing processes of microaccelerometer sensor by electrostatic force.

  • PDF

어육신선도 측정장치의 개발 (Development of device for the degree of freshness of wet fish)

  • 유휘룡;이남걸;신민생;조영제;김상봉
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1992년도 한국자동제어학술회의논문집(국내학술편); KOEX, Seoul; 19-21 Oct. 1992
    • /
    • pp.272-275
    • /
    • 1992
  • Recently, the digital circuit technique has had great success and gained importance in all industries. For the measurement of degree of freshness of plant and animal's tissue, many devices has been developed. But it's data was inaccurate and it had difficulty in making database because it was depend on analog circuit technique. The purpose of this paper is the development of a device based on digital circuit for measurement of freshness degree of wet fish such that its accuracy is very trustworthy and it can be measured in a short time. The device is developed by using micro-computer with some interface modules of A-D/D-A converter and digital circuit with IC modules and its effectiveness has been evaluated through two experimental results of electrical Q-value test and chemical K-value test.

  • PDF

근관 밀폐도에 미치는 도말층 및 상아질 접착강화제의 영향 (EFFECTS OF SMEAR LAYER AND DENTIN PRIMERS ON THE SEALING ABILITY OF ROOT CANAL)

  • 양진석;황인남;김원재;오원만
    • Restorative Dentistry and Endodontics
    • /
    • 제25권4호
    • /
    • pp.527-535
    • /
    • 2000
  • The purpose of this study was to evaluate effects of smear layer and dentin primers on the sealing ability of root canals. 126 extracted human teeth with single, straight canals and mature apices were used. The Samples were first classified into six groups as follows: presence of smear layer; absence of smear layer; Scotchbond Bond Multi-Purpose; All Bond 2; Mac Bond 2; Clearfil Liner Bond 2. A Positive control was also established. All teeth except the control group were then obturated with thermoplasticized gutta-percha and AH26. Electrochemical and dye penetration technique were later used to evaluate the degree of micro leakage through the root canal. Seventy teeth were then immersed in a 1% potassium chloride solution and An external power supply(DC 10 V) was then applied to the circuit for the electrochemical microleakage test. The degree of Microleakage was determined over period of 28 days before being evaluated. In total, 48 teeth were submitted to the dye infiltration technique. All specimen were suspended in 2% methylene blue dye for 1 week before being longitudinally split. The degree of dye infiltration was measured under a stereo microscope at ${\times}10$ magnification and evaluated. The results were as follows: 1. Apical microleakage increased throughout the test period in all group and one group having a smear layer showed a dramatic increase under electrochemical test (p<0.05). In the group having smear layer, the degree of apical microleakage was the highest, and the micro leakage was much higher than in the smear layer removed group in electrochemical test (p<0.05). Scotchbond Multi-Purpose, All Bond 2, Mac Bond 2 and Clearfil Liner Bond 2 showed lower micro leakage than one group having smear layer. The All Bond 2 and Clearfil Liner Bond 2 treated groups showed the lowest microleakage in electrochemical test (p<0.05). 2. There was no significant difference between the experimental groups in dye penetration technique. These results suggested that the removal of the smear layer from root canal and concomitantly the application of dentin primer into root canal could improve the sealing ability of root canal obturation.

  • PDF

WiMAX 응용을 위한 결합 공진기 기반의 PCB 내장형 평형신호 듀플렉서의 설계 (Design of PCB Embedded Balanced-to-unbalanced WiMax Duplexer Using Coupled LC Resonators)

  • 박주용;박종철;박재영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.1587_1588
    • /
    • 2009
  • In this paper, PCB embedded balanced-to-unbalamced duplexer using coupled LC resonator was introduced for low cost dualband WiMax front-end-module application. In order to obtain the function of bandpass filter and balun transformer, proposed duplexer was configured by using magnetically coupled LC resonator. Out-of-band suppression was enhanced by applying two m-Derived transform circuits to obtain transmission zeros at 2GHz and 4.8GHz. In order to reduce the size of embedded duplexer, BaSrTiO3 (BST) composite high Dk RCC film was applied to improve the capacitance density. This high Dk film provided the capacitance density of 12.2 pF/mm2. The simulation results shows that fabricated duplexer had an insertion loss of 2.9dB and 5.5dB and return loss of 15dB and 16dB for 2.5GHz~2.6GHz and 3.5GHz~3.6GHz, respectively. The maximum magnitude and phase imbalance were 0.01dB and 0.17dB, and 1degree and 2degree in its passband, respectively. The out-of-band suppression was observed approximately 29dB and 40dB below 1.9GHz and over 4.5GHz, respectively. It has a volume of 6 mm $\times$ 7 mm $\times$ 0.7 mm (height).

  • PDF