• Title/Summary/Keyword: Method of Difference Analysis

Search Result 6,405, Processing Time 0.051 seconds

A Study on the Guardian's Perception of Attending Patient in Pediatric Radiography (소아 방사선 검사 시 보호자 참여에 대한 인식도 조사)

  • Kwak, JongHyeok;Jeong, JaeBeom
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.4
    • /
    • pp.189-201
    • /
    • 2014
  • The purpose of this study was to survey guardian's opinion on assisting pediatric radiography and their level of awareness of radiation, improving the quality of pediatric radiography. In this study, the recognition was analyzed for 210 parents of child patients in Pusan National University Hospital from August 20 to September 15, 2013. A total of 66.2 percent of the respondents said they had participated in pediatric radiography in the past. The reason why they did is "Radiologist's request", the highest. According to the survey, 84.3 percent said they thought it is necessary to attending patient in pediatric radiography. "The stability of the child" is the reason for it. And respondents who thought there's no need to do that answered back, the reason for this is "Radiologist's work." There was a significant difference on the psychological state for the medical radiation by gender and child age. (p<0.05) In the analysis of recognition for the radiation, there was the significance by gender and education. (p<0.05) Regarding the awareness of the radiation protector, there was a statistical significance in age, gender, child age and education. (p<0.05) Considering the results, pediatric patient's guardians recognized that it is necessary to attend a child on X-ray for their child's stability and accurate exam above all. It must make guardians wear X-ray protector and radiologist should let the guardians recognize the X-ray examination method, before starting pediatric x-ray. It needs to improve the atmosphere of the examination room and to be considered to take visual and auditory approaches in comfort for reducing the children's fear and anxiety.

A Study on the Fabrication and Comparison of the Phantom for CT Dose Measurements Using 3D Printer (3D프린터를 이용한 CT 선량측정 팬텀 제작 및 비교에 관한 연구)

  • Yoon, Myeong-Seong;Kang, Seong-Hyeon;Hong, Soon-Min;Lee, Youngjin;Han, Dong-Koon
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.6
    • /
    • pp.737-743
    • /
    • 2018
  • Patient exposure dose exposure test, which is one of the items of accuracy control of Computed Tomography, conducts measurements every year based on the installation and operation of special medical equipment under Article 38 of the Medical Law, And keep records. The CT-Dose phantom used for dosimetry can accurately measure doses, but has the disadvantage of high price. Therefore, through this research, the existing CT - Dose phantom was similarly manufactured with a 3D printer and compared with the existing phantom to examine the usefulness. In order to produce the same phantom as the conventional CT-Dose phantom, a 3D printer of the FFF method is used by using a PLA filament, and in order to calculate the CTDIw value, Ion chambers were inserted into the central part and the central part, and measurements were made ten times each. Measurement results The CT-Dose phantom was measured at $30.44{\pm}0.31mGy$ in the periphery, $29.55{\pm}0.34mGy$ CTDIw value was measured at $30.14{\pm}0.30mGy$ in the center, and the phantom fabricated using the 3D printer was measured at the periphery $30.59{\pm}0.18mGy$, the central part was $29.01{\pm}0.04mGy$, and the CTDIw value was measured at $30.06{\pm}0.13mGy$. Analysis using the Mann - Whiteney U-test of the SPSS statistical program showed that there was a statistically significant difference in the result values in the central part, but statistically significant differences were observed between the peripheral part and CTDIw results I did not show. In conclusion, even in the CT-Dose phantom made with a 3D printer, we showed dose measurement performance like existing CT-Dose phantom and confirmed the possibility of low-cost phantom production using 3D printer through this research did it.

Estimation of Characteristics and Methane Production Rate of Food Waste (음식물류 폐기물 특성 및 메탄 발생가능량 평가)

  • Lee, Min-Kyu;Kim, Kyung;Shin, Hyun-Gon;Bae, Ki-Hwan;Kim, Choong-Gon;Park, Joon-Seok
    • Clean Technology
    • /
    • v.25 no.3
    • /
    • pp.223-230
    • /
    • 2019
  • This research was performed to evaluate the characteristics of food waste from 5 areas in Gangwon Province, Korea and to predict the $CH_4$ gas production rate. Food wastes were sampled in July and September, 2017. The amount of methane gas generation was evaluated through the biochemical methane potential (BMP) test and a calculation method using chemical composition. Average bulk density and pH of the food wastes were in the range of $0.758{\sim}0.850g\;cm^{-3}$ and 4.29 ~ 4.75, respectively. By physical composition, vegetables were the highest with 56.43 ~ 72.81% with fruits recording 5.31 ~ 8.95%, cereals 1.60 ~ 18.73%, fish and meat 4.47 ~ 12.11%, and filtrate 1.76 ~ 3.64%. The average water content was 69.30 ~ 75.87%, and VS and ash content were 22.50 ~ 27.98% and 1.63 ~ 2.48%, respectively. In addition, $BOD_5$, $COD_{Cr}$, and $COD_{Mn}$ were in the ranges of $17,690.3{\sim}33,154.9mg\;L^{-1}$, $106,212.3{\sim}128,695.5mg\;L^{-1}$, and $51,266.1{\sim}63,426.3mg\;L^{-1}$, respectively. The NaCl content ranged from 0.81 to 1.17%. The results of elemental analysis showed that the contents of C, H, O, N, and S were 44.87 ~ 48.1%, 7.12 ~ 7.57%, 40.13 ~ 43.78%, 3.22 ~ 4.14%, and 0.00 ~ 0.02%, respectively. In a comparison of the methane production yield per VS mass of food waste, there was no significant difference between the cumulative amount (${0.303{\sim}0.354m_{CH4}}^3\;{kg_{VS}}^{-1}$) by the BMP test and the theoretical amount (${0.294{\sim}0.352m_{CH4}}^3\;{kg_{VS}}^{-1}$) calculated by chemical composition.

Effect of polishing methods on color change by water absorption in several composite resins (여러 복합레진에서 수분 흡수에 의한 색변화에 연마가 미치는 영향)

  • Kim, Hye Jin;Kim, Mi-yeon;Song, Byung-chul;Kim, Sun-ho;Kim, Jeong-hee
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.35 no.1
    • /
    • pp.1-10
    • /
    • 2019
  • Purpose: The aim of this study was to evaluate the influence of polishing methods on the color stability of composite resins. Materials and Methods: Two bulk-fill and four conventional resin composites were filled in cylindrical molds (6 mm diameter, 4 mm height) and light-cured. The specimens were stored in $34^{\circ}C$ distilled water for 24 h. Spectrophotometer was used to determine the color value according to the CIE $L^*a^*b^*$ color space. Each group was divided into three groups according to polishing methods (n = 5). Group 1 was control group (Mylar strip group), group 2 was polished with PoGo, and group 3 was polished with Sof-Lex Spiral wheels. Color evaluation was performed weekly for 4 weeks after immersion in $34^{\circ}C$ distilled water. The results were analyzed by generalized least squares method (P < 0.05). Results: Generalized least squares analysis revealed that Sof-Lex Spiral wheels group showed the significantly lower ${\Delta}E$ values compared to PoGo and control group (P < 0.05). The ${\Delta}E$ values of polished group showed the significantly lower than the ${\Delta}E$ values of unpolished group (P < 0.05). Regarding color changes of composite resins, there was no significant difference between the ${\Delta}E$ values of Filtek Z250 and Filtek Z350 XT Universal restorative in all time intervals (P < 0.05). Tetric N-Ceram Bulk Fill showed the significantly lower ${\Delta}E$ values compared to other composite resins in 1, 2, 3 weeks (P < 0.05). Conclusion: Within the limitations of this study, polishing methods influence the color stabilities of composite resins. The group polished with Sof-Lex Spiral Wheels showed more resistance to discoloration than group polished with PoGo.

Predictions of VO2max Using Metabolical Responses in Submaximal Exercise and 1,200 m Running for Male, and the Validity of These Prediction Models (성인 남성의 최대하 운동시 대사반응 및 1,200 m 달리기 기록을 이용한 최대산소섭취량 추정식 개발 및 타당도)

  • Im, J.H.;Jeon, Y.J.;Jang, H.K.;Kim, H.J.;Kim, K.H.;Lee, B.K.
    • Exercise Science
    • /
    • v.21 no.2
    • /
    • pp.231-242
    • /
    • 2012
  • The purpose of this study was to develop the prediction model of VO2max using submaximal metabolic responses from the Bruce protocol, HR responses at several stages and 1,200 m running record, and to compare and analyse the validity of these prediction models. The subjects were consisted of 255 male(133 male for 1,200 m running). They were participated maximal exercise testing with Bruce protocol, and the metabolic responses were measured in the end of the first(3 minute), second stage(6 minute), and 1,200 m running record. Measurement items were VO2(㎖/kg/min), VCO2(㎖/kg/min), VE(L/min), HR(bpm) of 3 and 6 minute, time to HR 150 bpm and 170 bpm, HR difference between Bruce protocol 6 and 3 minute, 1,200 m running record. Analyzing with all variables using enter method, the multiple R of total variable model was 0.642(p<.01), SEE was 4.38 ㎖/kg/min, CV was 10.8 %, but multicolinearity was appeared. The multiple R of 3 minutes model 1 and model 2 were 0.341 and 0.461, SEE was 6.05 and 5.72 ㎖/kg/min, CV was 14.9 and 14.1%, and multicolinearity did not appeared. The multiple R of 6 minutes model 1 and model 2 were 0.350 and 0.456, SEE was 6.03 and 5.74 ㎖/kg/min, CV was 14.9 and 14.2%, and multicolinearity did not appeared. The R of HR 170 and HR 170 model were 0.151 and 0.154, SEE were 6.36~6.37 ㎖/kg/min, CV were 15.7%. The R of 1,200 m running model was 0.444, SEE was 4.82 ㎖/kg/min, CV were 11.9%. In conclusion, with considering usefulness and convenience through the validity of these prediction models, the prediction model of VO2max recommended 6 and 3 minute model, and the validity of HR model and 1,200 m running model were moderately low.

A study on the correlation between Sound Characteristic and Sasang Constitution by Laryngograph, EGG (Laryngograph와 EGG를 이용한 음향특성(音響特性)과 사상체질간(四象體質間)의 상관성(相關性) 연구(硏究))

  • Kim, Sun-hyung;Shin, Mi-ran;Kim, Dal-rae;Kwon, Ki-rok
    • Journal of Sasang Constitutional Medicine
    • /
    • v.12 no.1
    • /
    • pp.144-156
    • /
    • 2000
  • Purpose of this study is to help classifying Sasang Constitution through correlation with Larynx waveform. This study was done it under the suppose that Sasang Constitution would be correlation with Larynx waveform. The following result were obtained about correlation between Erectroglottograph waveform and Sasang Constitution by analysis EGG program. 1. Taeumin was lower than Soyangin in Open Std Deviation, Contact Std Deviation of male/a/(0.5sec) 2. Soeyangin was high compared with the others in Pitch range of maie/a/(2.5sec) 3. Taeumin was higher than Soeumin in Pitch range, Soeyangin in pitch Maximum, and the others in Pitch Std Deviation of female/e/(0.5sec) 4. Taeumin was higher than Soeumin in Contact Maximum and lower than Soeumin in Contact Maximum of female/a/(2.5sec) 5. There was no significantly difference in male/e/(0.5sec), male/e/(2.5sce), female/a/(0.5sec), female/e/(2.5sec) 6. The percent of correctly classified in Soeoumin and Taeumin was high in CART Algolism. The risk estimate of Soyangin was relatively high. The study may be use on of the method to make objective diagnosis in Sasang constitution.

  • PDF

The Effect of Packing Method of Relining Material on the Flexural Strength of Denture Base Resin (첨상용 레진의 성형법이 의치상의 굴곡강도에 미치는 영향)

  • Kim, Min-Chul;Kim, Yu-Lee
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.27 no.2
    • /
    • pp.197-207
    • /
    • 2011
  • The study aimed at examining how different reline resins affect flexural strength and flexural modulus of denture base. A total of 80 specimens ($64{\times}10{\times}3.3$ mm, according to ISO 1567:1999) of heat-polymerized resin, 40 specimens for (Lucitone199(Dentsply Int., NewYork, USA), SR Ivocap(Ivoclar AG, Schaan, Liechtenstein)) respectively, were polymerized according to the manufacturer's instructions and divided into eight groups(n = 10). Control group specimens remained intact. Specimens in the other groups were abraded on both sides to 2 mm thickness, and were relined in 1.3 mm thickness with 3 types of resins (Lucitone199(Dentsply), SR Ivocap(Ivoclar), and Rebase II(Tokuyama Co., Ltd, Tokyo, Japan)). All specimens were preserved in distilled water at $37^{\circ}C$ for 50 hours, and then were subjected to flexural strength testing in a universal testing machine using 3-point loading. A crosshead speed of 5 mm/min was used, and the distance between the supports was 50 mm. Data analyses included one-way analysis of variance(ANOVA) and the Tukey Honestly Significant Difference test (p=.05). Both heat-polymerized resin groups and auto-polymerized resin groups showed statistically low flexural strength and flexural modulus than control groups. Specimens relined with Lucitone 199 showed significantly higher flexural strength and flexural modulus than those relined with SR-Ivocap. Specimens relined with auto-polymerized resin showed significantly lower flexural strength and flexural modulus than those relined with heat-polymerized resin. Relining with heat-polymerized resins showed superior mechanical properties to relining with an auto-polymerized resin. Relining with the same heat-polymerized resin as the denture base does not affect mechanical properties of a denture. Lucitone199 using a compression-mould technique resulted in the highest flexural strength.

Corona Blue and Leisure Activities : Focusing on Korean Case (코로나 블루와 여가 활동 : 한국 사례를 중심으로)

  • Sa, Hye Ji;Lee, Won Sang;Lee, Bong Gyou
    • Journal of Internet Computing and Services
    • /
    • v.22 no.2
    • /
    • pp.109-121
    • /
    • 2021
  • As the global COVID-19 pandemic is prolonged, the Corona Blue phenomenon, combined with COVID-19 and blue, is intensifying. The purpose of this study is to analyze the current trend of Corona Blue in consideration of the possibility of increasing mental illness and the need for countermeasures, especially after COVID-19. This study tried to find out the relationship between stress and leisure activities before and after COVID-19 by using Corona Blue news article analysis through the topic modeling method, and questionnaire find out the help of stress and leisure activities. This study was compared and analyzed using two research methods. First, a total of 363 news articles were analyzed through topic modeling based on newspaper articles from January 2020, when COVID- 19 was upgraded to the "border" stage, until September, where the social distancing stage was strengthened to stage 2.5 in Korea. As a result of the study, a total of 28 topics were extracted, and similar topics were grouped into 7 groups: mental-demic, generational spread, causes of depression acceleration, increased fatigue, attitude to coping with long-term wars, changes in consumption, and efforts to overcome depression. Second, the SPSS statistical program was used to analyze the level of stress change according to leisure activities before/after COVID-19 and the main help according to leisure activities. As a result of the study, it was confirmed that the average difference in stress reduction according to participation in leisure activities before COVID-19 was larger than after COVID-19. Also, leisure activities were found to be effective in stress relief even after COVID-19. In addition, if the main help from leisure activities before COVID-19 was the meaning of relaxation and recharging through physical and social activities. After COVID-19, psychological roles such as mood swings through nature, outdoor activities, or intellectual activities were found to play a large part. As such, in this study, it was confirmed that understanding the current status of Corona Blue and coping with leisure in extreme stress situations has a positive effect. It is expected that this research can serve as a basis for preparing realistic and desirable leisure policies and countermeasures to overcome Corona Blue.

Comparison of Bone Volume Measurements Using Conventional Single and Dual Energy Computed Tomography (전산화단층영상검사에서 단일에너지와 이중에너지를 이용한 뼈 부피측정의 비교)

  • Kim, Yung-kyoon;Park, Sang-Hoon;Kim, Yon-Min
    • Journal of radiological science and technology
    • /
    • v.40 no.2
    • /
    • pp.253-259
    • /
    • 2017
  • The study examines changes in calcium volume on born by comparing two figures; one is measured by dual energy computed tomography(DECT) followed by applying variation in monochromatic energy selection(keV), material decomposition(MD), and material suppressed iodine(MSI) analysis, and the other is measured by conventional single source computed tomography(CSCT). For this study, based on CSCT images taken by using human mimicked phantom, 70, 100, 140 keV and MSI, MD material calcium weighting(MCW) and MD material iodine weighting(MIW) of DECT were applied respectively. Then calculated calcium volume was converted to Agatston score for comparison. Volume of human mimicked phantom was in inverse proportion to keV. The volume decreased while keV increased(p<0.05). The most similar DECT volumes were reconstructed at 70 keV, the difference was showed $35.8{\pm}12.2$ for rib, femur ($16.1{\pm}24.1$), pelvis($13.7{\pm}18.8$), and spine($179.0{\pm}61.8$). However, the volume of MSI was down for each organ; the volume of rib was 5.55%, femur(76.34%), pelvis(55.16%) and spine(87.58%). The volume of MSI decreased 55.9% for rib, femur(80.7%), pelvis(69.6%) and spine(54.2%) while MD MIW reduced for rib(83.51%), femur(87.68%), pelvis(86.64%), and spine(82.62%). With the results, the study found that outcomes were affected by the method which examiners employed. When using DECT, calcium volume of born dropped with keV increased. It also found that the most similar DECT images were reconstructed at 70 keV. The results of experiments implied that the users of MSI and MD should be cautious of errors as there are big differences in scores between those two methods.

The Influence of Gender on the Long-term Outcome of Coronary Artery Bypass Surgery (성별에 따른 관상동맥 우회술의 장기 결과)

  • Choi Jong-Bum;Lee Mi-Kyung;Cha Byoung-Ki;Lee Sam-Youn
    • Journal of Chest Surgery
    • /
    • v.39 no.6 s.263
    • /
    • pp.449-455
    • /
    • 2006
  • Background: Female sex was known to be a risk factor for mortality after coronary bypass grafting (CABG), and women showed higher in-hospital mortality than men. Material and Method: Between 1992 and 1996, 147 consecutive patients (98 men and 49 women) undergoing CABG were included in the study. Most patients had undergone CABG with left internal thoracic artery and saphenous vein under cardiopulmonary bypass. We examined the influence of gender on survival after CABG and looked for risk factors for survival. Result: There was no in-hospital mortality in women, but 3 death (3.0%) in men. During the mean follow-up period of $138.5{\pm}23.0$ months, mortality was lower in women than in men (20.4% vs 44.9%, p=0.004), and the most common cause of death in women was chronic renal failure (40%). Survival in women at 1, 5, 10, and f4 years was 100%, $98.0{\pm}2.0%,\;81.2{\pm}5.6%,\;and\;78.4{\pm}6.1%$, respectively, which was better than in men (p=0.004). Although preoperative left ventricular ejection fraction was higher in women than in men, this did not affect early and long-term survival difference between two sexes (p=0.15). Risk factor for long-term survival in women was diabetes (p=0.033) and in men number of diseased coronary artery (p=0.006). Conclusion: Long-term survival after CABG was better in women than men. Risk factor for long-term survival in women was morbid disease rather than cardiac disease.