• Title/Summary/Keyword: Method of Compliance

Search Result 896, Processing Time 0.036 seconds

Study on Health Behavior of Hypertensive Patients and Compliance for Treatment of Antihypertensive Medication (고혈압 환자들의 순응도와 건강행태의 관계)

  • Kim, Joo-Yeon;Lee, Dong-Bae;Cho, Young-Chae;Lee, Sok-Goo;Chang, Seong-Sil;Kwon, Yun-Hyung;Lee, Tae-Yong
    • Journal of agricultural medicine and community health
    • /
    • v.25 no.1
    • /
    • pp.29-49
    • /
    • 2000
  • Objectives: To estimate the prevalence rate of hypertension, the changes of health behavior, and compliance for the drug treatment after diagnosed as hypertension. Methods: 7,030 persons who live in Cheonan City of Chungnam Province were selected by the cluster sampling method, and 5,372 persons were surveyed by questionnaire and health examination. This data is analyzed by Chi-square test on each variable. Results: 49.8%- of men and 38.8%- of women had been diagnosed as hypertension, and the prevalence rate of hypertension was significantly increased with aging in both gender. The prevalence rate tended to decrease in highly educated women group. Unemployed persons or obese persons showed relatively higher prevalence rate. The prevalence rate of hypertension increased in groups with higher total cholesterol levels over 240 mg/dl, and groups with glucose level over 200 mg/dl. 53.1%- of male patients and 66.6%- of female patients showed compliance for antihypertensive treatment. Compliance for treatment was higher in aged group or lower educated group in both gender. Among men, proportion of compliant subjects was higher in unemployed group(49.3%-), and lower in labor or primary industry than the others but among women, there was not any significant difference. And men with compliance for treatment had higher monthly income than the others, but women did not show any. Conclusion : This population had a high prevalence rate of hypertension which may lead to cardiovascular disease. Therefore health education programs and distribution of information must be emphasized in order to increase compliance to treatment and encourage the change of health behavior to promote health.

  • PDF

A Tolerance Analysis Method for Spot-welded Deformable Auto Body Parts (점용접되는 차체 부품의 공차 해석 기법)

  • So, Hyun-Chul;Kim, Kuk-Saeng;Yim, Hyun-June;Jee, Hae-Seong;Park, Bong-Jun;Yoo, In-Suk
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.14 no.2
    • /
    • pp.23-31
    • /
    • 2006
  • Tolerance analysis of auto body requires the consideration of its compliance because of potentially significant deformation during the spot-weld assembly process. In this paper, a relatively recent method for such analyses is briefly introduced as one can find in the literature. In this method, it is important to take into account of the covariance between the sources of variation as they are closely located, which is the case in most auto body assembly. However, it is often impossible to know such covariance, for example, when a new car is being developed. Therefore, a mechanics-based method is proposed in this paper to estimate the covariance among the sources of variation by finite element analyses and simple statistical computations. The proposed method is illustrated by applying it to a three-dimensional model of real front wheel housing.

A Study on Analysis of Mode I interlaminar Fracture Toughness of Foam Core Sandwich Structures (FOAM CORE SANDWICH 구조재의 Mode I 층간분리 파괴인성의 해석에 관한 연구)

  • Son, Se-Won;Gwon, Dong-An;Hong, Seong-Hui
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.17 no.9
    • /
    • pp.81-86
    • /
    • 2000
  • This paper was carried out to investigate the characteristics of interlaminar fracture toughness of foam core sandwich structures under opening loading mode by using the double cantilever beam (DCB) specimens in Carbon/Epoxy and foam core composites. instead of using symmetric geometry of DCB specimen non-symmetric DCB specimen was used to calculate the interlaminar fracture toughness. Three approaches for calculating the energy release rate({{{{ {G }_{IC } }}}}) were compared. Fracture toughness of foam core sandwich structures by autoclave vacuum bagging and hotpress were compared and analyzed. Experiment nonlinear beam bending FEM method were performed. Suggested bonding surface compensation and equivalent area inertia moment was used to calculate the energy release rate in nonlinear analytical results. The conclusions among experimental nonlinear analytical and FEM results was observed. The vacuum bagging method was shown to be able to substitute method in stead of autoclave without serious loss of Mode I energy release rate({{{{ {G }_{IC }}}}}) to be able to substitute method in stead of autoclave without serious loss of Mode I energy release rate({{{{ {G }_{IC }}}}}).

  • PDF

A Simple Control Method for Opening a Door with Mobile Manipulator

  • Kang, Ju-Hyun;Hwang, Chang-Soon;Park, Gwi-Tae
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.1593-1597
    • /
    • 2003
  • The home service robot supports human beings by performing various kinds of works at home. This paper presents a simple control method for opening a door from the viewpoint of the mobile manipulation. The simulation shows various results of path planning and motion planning for opening a door. The joint trajectories were generated by the simulation system. In general, a six-axis force/torque sensor at an end-effector is needed in order to maintain the static equilibrium of the manipulator. But we show another method. From three components of applied forces which was directly obtained by the three-axis force sensor and three components of applied forces which was indirectly estimated by the joint-torque sensors, all of joint torques that will exactly balance forces at the end-effector in the static situation can be found. It is more practical method than using a six-axis force sensor in a wrist. Experimental results have shown that the opening a door can be realized more effectively from the suggested control method of mobile manipulation.

  • PDF

Level Set Based Shape Optimization of Linear Structures Using Topological Derivatives (Topological Derivative를 이용한 선형 구조물의 레벨셋 기반 형상 최적 설계)

  • Ha Seung-Hyun;Kim Min-Geun;Cho Seon-Ho
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2006.04a
    • /
    • pp.299-306
    • /
    • 2006
  • Using a level set method and topological derivatives, a topological shape optimization method that is independent of an initial design is developed for linearly elastic structures. In the level set method, the initial domain is kept fixed and its boundary is represented by an implicit moving boundary embedded in the level set function, which facilitates to handle complicated topological shape changes. The 'Hamilton-Jacobi (H-J)' equation and computationally robust numerical technique of 'up-wind scheme' lead the initial implicit boundary to an optimal one according to the normal velocity field while minimizing the objective function of compliance and satisfying the constraint of allowable volume. Based on the asymptotic regularization concept, the topological derivative is considered as the limit of shape derivative as the radius of hole approaches to zero. The required velocity field to update the H -J equation is determined from the descent direction of Lagrangian derived from optimality conditions. It turns out that the initial holes is not required to get the optimal result since the developed method can create holes whenever and wherever necessary using indicators obtained from the topological derivatives. It is demonstrated that the proper choice of control parameters for nucleation is crucial for efficient optimization process.

  • PDF

Analysis of Fatigue Crack Opening: Belhlavioll Using Direct Measuring Method (직접측정법에 의한 피로크랙 개구거동의 해석)

  • Song, Sam-Hong;Kim, Hyun
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.8
    • /
    • pp.1493-1502
    • /
    • 1992
  • The purpose of this study is to identify the effects of loading variables on fatigue crack opening behavior, using structural steel SS41. To use various stress ratios, three kinds of the methods varying stress ratio were used; .DELTA.P const., P$_{max}$ const., and P$_{min}$ const.. To measure the opening load, the direct measuring method which measures the distance between two micro indentations 20 .mu.m behind crack tip and the elastic compliance method were used. As the results of present study, the following conclusions are obtained. First, using the direct measuring method, it was possible to measure the COD at any location behind crack tip. Second, as measuring point becomes farther from crack tip, opening load becomes smaller. Third, the acceleration of da/dN near notch is due to crack opening behavior. Finally, opening ratio is a function of not only R, but .DELTA.K.K.K.

Impact of Pulmonary Vascular Compliance on the Duration of Pleural Effusion Duration after Extracardiac Fontan Procedure (수술 전 폐혈관 유순도가 심장 외 도판을 이용한 Fontan 수술 후 늑막 삼출 기간에 미치는 영향)

  • Yun Tae-Jin;Im Yu-Mi;Song Kwang-Jae;Jung Sung-Ho;Park Jeong-Jun;Seo Dong-Man;Lee Moo-Song
    • Journal of Chest Surgery
    • /
    • v.39 no.8 s.265
    • /
    • pp.579-587
    • /
    • 2006
  • Background: Preoperative risk analysis for Fontan candidates is still less than optimal in that patients with apparently low risks may have poor surgical outcome; prolonged pleural drainage, protein losing enteropathy, pulmonary thromboembolism and death. We hypothesized that low pulmonary vascular compliance (PVC) is a risk factor for prolonged pleural effusion drainage after the Fontan operation. Material and Method: A retrospective review of 96 consecutive patients who underwent the Extracardiac Fontan procedures (median age: 3.9 years) was performed. Fontan risk score (FRS) was calculated from 12 categorized preoperative anatomic and physiologic variables. PVC $(mm^2/m^2{\cdot}mmHg)$ was defined as pulmonary artery index $(mm^2/m^2)$ divided by total pulmonary resistance $(W.U{\cdot}/m^2)$ and pulmonary blood flow $(L/min/m^2)$ based on the electrical circuit analogue of the pulmonary circulation. Chest tube indwelling time was log-transformed (log indwelling time, LIT) to fit normal distribution, and the relationship between preoperative predictors and LIT was analyzed by multiple linear regression. Result: Preoperative PVC, chest tube indwelling time and LIT ranged from 6 to 94.8 $mm^2/mmHg/m^2$ (median: 24.8), 3 to 268 days (median: 20 days), and 1.1 to 5.6 (mean: 2.9, standard deviation: 0.8), respectively. FRS, PVC, cardiopulmonary bypass time (CPB) and central venous pressure at postoperative 12 hours were correlated with LIT by univariable analyses. By multiple linear regression, PVC (p=0.0018) and CPB (p=0.0024) independently predicted LIT, explaining 21.7% of the variation. The regression equation was LIT=2.74-0.0158 PVC+0.00658 CPB. Conclusion: Low pulmonary vascular compliance is an important risk factor for prolonged pleural effusion drainage after the extracardiac Fontan procedure.

A Study on the Collecting Method of Reliability Database for Gas Facilities (가스설비의 신뢰도데이터 수집방법에 관한 연구)

  • Rhie, Kwang-Won;Yoon, Ik-Keun;Han, Sang-Tae;Oh, Sin-Kyu;Kim, Tae-Hun
    • Journal of the Korean Society of Safety
    • /
    • v.23 no.2
    • /
    • pp.37-44
    • /
    • 2008
  • The safety assessment for facility industry is now being periodically performed. For the purpose of scientific safety management, QRA(Quantitative Risk Assessment) is also being performed, and reliability data of the facilities is essential to perform the assessment. Generally, the existing safety assessment is performed by using the values announced in other industry processes, which result in the drop of reliability. In order to solve this problem, there is an urgent need to establish reliability database for the facilities. The most appropriate method is to perform a direct reliability analysis towards the facilities undergoing safety assessment. In this study, in compliance with the assessment method and procedure of OREDA-2002 handbook, the facility reliability data are collected, which include the calendar time and operational time in terms of different facility items, the number of failures in terms of different failure mode, the mean, standard deviation, lower limit and upper limit of failure rate, and the failure rate. And the data process method for this special occasion is also proposed when the number of failure is 0.

Vision-Based Identification of Personal Protective Equipment Wearing

  • Park, Man-Woo;Zhu, Zhenhua
    • International conference on construction engineering and project management
    • /
    • 2015.10a
    • /
    • pp.313-316
    • /
    • 2015
  • Construction is one of the most dangerous job sectors, which reports tens of thousands of time-loss injuries and deaths every year. These disasters incur delays and additional costs to the projects. The safety management needs to be on the top primary tasks throughout the construction to avoid fatal accidents and to foster safe working environments. One of the safety regulations that are frequently violated is the wearing of personal protection equipment (PPE). In order to facilitate monitoring of the compliance of the PPE wearing regulations, this paper proposes a vision based method that automatically identifies whether workers wear hard hats and safety vests. The method involves three modules - human body detection, identification of safety vest wearing, and hard hat detection. First, human bodies are detected in the video frames captured by real-time on-site construction cameras. The detected human bodies are classified into with/without wearing safety vests based on the color features of their upper parts. Finally, hard hats are detected on the nearby regions of the detected human bodies and the locations of the detected hard hats and human bodies are correlated to reveal their corresponding matches. In this way, the proposed method provides any appearance of the workers without wearing hard hats or safety vests. The method has been tested on onsite videos and the results signify its potential to facilitate site safety monitoring.

  • PDF

A Study on the Determination Method of TOC Effluent Limitation for Public Sewage Treatment Plants (하수처리시설의 방류수 수질기준 설정방법 고찰 - TOC를 중심으로 -)

  • Jeong, Dong-Hwan;Cho, Yangseok;Ahn, Kyunghee;Chung, Hyen-Mi;Park, Hoowon;Shin, Hyunsang;Hur, Jin;Han, Daeho
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.30 no.3
    • /
    • pp.241-251
    • /
    • 2016
  • As the Enforcement Ordinance of Environmental Policy Act was revised in 2013, total organic carbon(TOC) was added as an indicative parameter for organic matter in Water and Aquatic Ecosystem Environmental Criteria. Under these imminent circumstances, a regulatory standard is needed to achieve the proposed TOC limitation control water quality from the public sewage treatment plants(PSTWs). This study purposes to present the determination method for TOC effluent limitation at the PSTWs. Therefore we investigate the TOC effluent limitation of foreign countries such as EU, Germany and USA, and analyse the effluent water qualities of PSTWs. In using these TOC data, we review apprehensively the statistics-based, the technology-based, and the region(water quality)-based determination method of TOC effluent limitation for PSTWs.