• 제목/요약/키워드: Meter set

Search Result 199, Processing Time 0.025 seconds

An Analysis of Efficiency and Government Policies of ESS (에너지 저장시스템의 효율성 검토 및 정책 분석)

  • Kim, Bum-Gon;Lee, Seoung-Cheol;Kim, Cheol-Hwan;Lee, See-Bin
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.2373-2382
    • /
    • 2011
  • As the government set the direction for Green Growth recently, so local government struggles to obtain carbon emissions trading. In the center of this global environment atmosphere, the quantitative targets would be suggested by some developed countries. In case of a international green movement like this, it would have been being induced from by crystallizing of economic and environmental regulations and legal policies that not only a meter-rate system of carbon emissions but also application for regenerate energy. In this paper, we researched cultivating of energy storage system(ESS) to conjugate regenerative energy of train, an energy efficiency and cultivating cost etc. In conclusion, we would acknowledge a difficulty in cultivating ESS only for cost reduction of energy consumption, so governmental policies for green growth should be thoughtfully examined.

  • PDF

A Study on Smart Peak Power Control System (스마트 최대 전력 관리 시스템 알고리듬 연구)

  • Lee, Woo cheol
    • Proceedings of the KIPE Conference
    • /
    • 2013.11a
    • /
    • pp.227-228
    • /
    • 2013
  • The paper is related to smart maximum power system based on program logic. Especially, this system compares the total demand power with the target power by using the signal from the digital kilo watt meter. Based on the power information by the maximum power control equipment the consumed future power is anticipated. In addition, through consumed future power the controllable target power is set, and it applies on the maximum power control equipment. User or manager would control the load efficiently through the simple programming which could control load based on the control sequence and relay. So this system could control load more efficient and stable. Also the conventional load control circuit is not needed. Therefore, it is possible to improve the simple system configuration, which is resulted in cost effective and time saving. So this system is anticipated on time and coast.

  • PDF

Development of the On-Vehicle Information Display System (차내 정보의 문자 표시 시스템 개발)

  • 권오규;심동규;박래홍;이상영;이순재;구본상
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.6 no.3
    • /
    • pp.161-168
    • /
    • 1998
  • This paper presents the on-vehicle information system that displays the states of the vehicle in brief words instead of symbols. Main functions of this system include a system check function, trip function, warning function, and clock function. With this system, a driver can obtain all sorts of useful information related to various conditions of the vehicle, and if any problem arises in the vehicle, he can recognize it by the displayed words with a warning sound. Also, this system is very helpful for safety driving because it displays whatever a driver wants to have concerning trip information. By experimental test and driving test, the development system shows good results for each function.

  • PDF

Isochronism of Feet in English Fixed Meter on Moraic Analysis and Durational Measurement in Reading (모라 분석과 낭송 측정에 의한 영시 정형률의 음보 등시성)

  • Kim Keyseop;Shin Dongil
    • Proceedings of the KSPS conference
    • /
    • 2002.11a
    • /
    • pp.157-160
    • /
    • 2002
  • This study aims to define the isochronism of English feet. To assess the average value of moras of a foot, the study is, first, to set up a way of counting the number of the moras on the extrametricality with some modifications. Secondly, with the measurement of the average duration of feet of Shakespeare's 120 sonnets through Praat (version 4.030, 2002), it clarifies the foot isochronism in English. With the two ways of measuring the isochronism, it clarifies the fact the foot isochronism permits the difference scope of $2.2{\mu}'s$ (moras) to $1.8{\mu}'s$, that is, $22{\mu}'s$ to $18{\mu}'s$ per line, while the acoustic assessment shows the isochronically congnitive gap of 302-447msec. per foot, or 4,461msec. to 3,019msec. per line in case of iambic pentameter in English poetry.

  • PDF

Feedwater Flow Rate Evaluation of Nuclear Power Plants Using Wavelet Analysis and Artificial Neural Networks (웨이블릿 해석과 인공 신경회로망을 이용한 원자력발전소의 급수유량 평가)

  • Yu, Sung-Sik;Seo, Jong-Tae;Park, Jong-Ho
    • 유체기계공업학회:학술대회논문집
    • /
    • 2002.12a
    • /
    • pp.346-353
    • /
    • 2002
  • The steam generator feedwater flow rate in a nuclear power plant was estimated by means of artificial neural networks with the wavelet analysis for enhanced information extraction. The fouling of venturi meters, used for steam generator feedwater flow rate in pressurized water reactors, may result in unnecessary plant power derating. The backpropagation network was used to generate models of signals for a pressurized water reactor. Multiple-input single-output heteroassociative networks were used for evaluating the feedwater flow rate as a function of a set of related variables. The wavelet was used as a low pass filter eliminating the noise from the raw signals. The results have shown that possible fouling of venturi can be detected by neural networks, and the feedwater flow rate can be predicted as an alternative to existing methods. The research has also indicated that the decomposition of signals by wavelet transform is a powerful approach to signal analysis for denoising.

  • PDF

A Study on the Characteristics of the Electronic EGR Valve for Gasoline Engine (가솔린엔진용 E-EGR 밸브 특성에 관한 연구)

  • Park, Cheol-Woong;Kim, Chang-Gi
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.16 no.1
    • /
    • pp.127-133
    • /
    • 2008
  • Since the 1960's, exhaust gas recirculation(EGR) has been used effectively in spark ignition(SI) engines to control the exhaust emissions of the oxides of nitrogen(NOx). The most important requirements for the application of EGR systems to conventional SI engines are controllable flow rate and good dynamic response. In order to evaluate the characteristics of the electronic EGR valve, a test bench which is consisted of blower, heater, air flow meter and driving unit for electronic EGR valve was set up to simulate engine operating conditions. During the tests, the valve actuation parameters were controlled and the valve lifts and flow rates were measured to infer the characteristics of EGR valve. The results confirmed the capabilities of mathematical analysis and it seems that the correction for the valve lift and potentiometer output is necessary to achieve precise control of EGR rates.

A Study on Measurement Selection Algorithm for Power System State Estimation Under the Consideration of Dummy Buses (DUMMY모선을 고려한 상태추정 측정점선정 알고리즘에 관한 연구)

  • 문영현;이태식
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.41 no.2
    • /
    • pp.107-117
    • /
    • 1992
  • This paper presents an improved algorithm of optimal measurement design with a reliability evaluation method for a large power system. The proposed algorithm is developed to consider the dummy bus and to achieve highest accuracy of the state estimator as well with the limited investment cost. The dummy bus in the power system is impossible to install measurement meter, while real and reactive power measurements is considered in the proposed algorithm. On the other hand, P/C model is developed by taking advantage of the matrix sparsity. The improved program is successfully tested for KEPCO system with PSS/E lineflow calculated data package.

  • PDF

Numerical Simulation of Oil Supply System of Reciprocating Compressor for Household Refrigerators (냉장고용 왕복동 압축기 급유 시스템의 수치해석)

  • Kim, H.J.;Lee, J.K.
    • Journal of Power System Engineering
    • /
    • v.9 no.4
    • /
    • pp.24-30
    • /
    • 2005
  • For a reciprocating compressor of household refrigerators, a direct analogy between the pipe flow network and the electric circuit network has been utilized to set up a mathematical model for oil supply system. Individual lubrication elements of the oil supply system, such as propeller- installed oil cap, oil galleries, radial oil feeding holes, spiral oil grooves, and various sliding surfaces have been analogized by equivalent electric elements, and these have been combined together to form an electric circuit corresponding to the whole oil supply system. By solving the closed network equations of the model, oil flow rates at various lubrication elements could be obtained. Total amount of the oil flow rate drawn into the shaft has been measured and compared reasonably well with the prediction of the numerical simulation.

  • PDF

Low Attenuation Waveguide for Structural Health Monitoring with Leaky Surface Waves

  • Bezdek, M.;Joseph, K.;Tittmann, B.R.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.32 no.3
    • /
    • pp.241-262
    • /
    • 2012
  • Some applications require structural health monitoring in inaccessible components. This paper presents a technique useful for Structural Health Monitoring of double wall structures, such as double wall steam pipes and double wall pressure vessels separated from an ultrasonic transducer by three layers. Detection has been demonstrated at distances in excess of one meter for a fixed transducer. The case presented here is for one of the layers, the middle layer, being a fluid. For certain transducer configurations the wave propagating in the fluid is a wave with low velocity and attenuation. The paper presents a model based on wave theory and finite element simulation; the experimental set-up and observations, and comparison between theory and experiment. The results provide a description of the technique, understanding of the phenomenon and its possible applications in Structural Health Monitoring.

Development of automatic flow control system based on LabView (LabView를 이용한 자동유량제어 시스템의 개발)

  • Kang, Tae-Won;Kim, Du-Seob;Ann, Sung-Gyu
    • Journal of Engineering Education Research
    • /
    • v.19 no.2
    • /
    • pp.3-7
    • /
    • 2016
  • A flow control system was designed and fabricated to control the flow rate of liquid through the pipe. This control system was composed of hardwares and software, hardwares as controller, gate valve, orifice meter and data aquisition board and software as National instruments Labview program. Control of flow rate was executed by adjusting the pneumatic valve located at the center of pipe line based on the control signal generated by LabView PID control algorithm, which converts analog signal measured by pressure difference of orifice to digital signal to adjust pneumatic valve. For the controller setup Ziegler-Nichols tuning technique was applied and control performances were investigated for not only the disturbance but also the set point changes. Developed system showed good control performances in flow control enough to use as teaching tool of feedback control theory and practice in university, and also as industrial application.