• Title/Summary/Keyword: Meter set

Search Result 199, Processing Time 0.029 seconds

Effects of Ultrasound on Skin Elasticity and Elasticity of Deeper Skin in Healthy Women (초음파 사용이 건강한 여성의 피부 탄력과 피부 깊은 탄력 개선에 미치는 영향)

  • Min-Joo Ko;Gi-Soo Kim;Eun-Mi Jang;Jae-Seop Oh
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.11 no.1
    • /
    • pp.79-86
    • /
    • 2023
  • Purpose : Aging is reflected on the face of women due to the depletion of collagen and hydration in the facial skin overtime. This study investigated the effect of multiple SONO® ultrasound for a 4-week period on the skin health by measuring the skin elasticity and deeper skin elasticity in the tested women subjects. Methods : Twenty healthy women were recruited for this experiment. All the participants applied multiple ultrasound device (SONO®) during this experiment. The SONO® device was set to ANTI-AGING function and five power steps such as 1, 3, 10 and 17 MHz were used during this experiment, and directly contacted with the facial skin. Specifically, the probe was contacted with the entire face except for the nose and eyes for 10 min on each side of the face every day and repeated for 4 weeks. The skin elasticity and the elasticity of deeper skin were measured at three times (0, 2, 4 weeks) using a Ballistometer and dermal torque meter, respectively. The one way repeated ANOVA was used to compare the skin elasticity and the elasticity of deeper skin among three times (0, 2, 4 weeks). Results : The skin elasticity (p<.05) and elasticity of deeper skin (p<.05) were significantly increased at 2 weeks and 4 weeks of intervention compared to that at 0 weeks. For the skin elasticity, there was no significant difference between 2 and 4 weeks of intervention (p>.05). For the elasticity of deeper skin, it increased significantly at 4 weeks compared to 2 weeks of intervention (p<.05). Conclusion : These findings suggest that applying multiple SONO® ultrasound to the facial skin of healthy women for 4 weeks, can increase the skin elasticity and elasticity of deeper skin by supporting epidermal hydration and dermal collagen production.

Comparison of Machine Learning Model Performance based on Observation Methods using Naked-eye and Visibility-meter (머신러닝을 이용한 안개 예측 시 목측과 시정계 계측 방법에 따른 모델 성능 차이 비교)

  • Changhyoun Park;Soon-hwan Lee
    • Journal of the Korean earth science society
    • /
    • v.44 no.2
    • /
    • pp.105-118
    • /
    • 2023
  • In this study, we predicted the presence of fog with a one-hour delay using the XGBoost DART machine learning algorithm for Andong, which had the highest occurrence of fog among inland stations from 2016 to 2020. We used six datasets: meteorological data, agricultural observation data, additional derived data, and their expanded data. The weather phenomenon numbers obtained through naked-eye observations and the visibility distances measured by visibility meters were classified as fog [1] or no-fog [0]. We set up twelve machine learning modeling experiments and used data from 2021 for model validation. We mainly evaluated model performance using recall and AUC-ROC, considering the harmful effects of fog on society and local communities. The combination of oversampled meteorological data features and the target induced by weather phenomenon numbers showed the best performance. This result highlights the importance of naked-eye observations in predicting fog using machine learning algorithms.

Effect of Side Walking Training Combined Squat on Balance and Gait Ability in Patients with Stroke (스쿼트를 병행한 옆으로 걷기 훈련이 뇌졸중 환자의 균형 및 보행에 미치는 영향)

  • Tae-Woo Kang;Da-Hee Kim
    • PNF and Movement
    • /
    • v.22 no.1
    • /
    • pp.13-21
    • /
    • 2024
  • Purpose: This study investigated the effects of side walking training combined with squats on the balance and gait ability of stroke patients. The purpose of this study was to provide fundamental data regarding the use of side walking training combined with squats among stroke patients. Methods: Thirty patients with stroke were randomly divided into an experimental group (n=15) that underwent side walking training combined with squats and a control group (n=15) that performed general rehabilitation exercises. Both groups performed their respective exercises for 30 minutes, five times a week for six weeks. Balance was assessed using the functional reach test and timed up and go test, while gait ability was evaluated using the 10-meter walk test. A paired t-test was performed to compare within-group changes before and after the intervention. Differences between the experimental and control groups were analyzed using an independent t-test. For all tests, the level of statistical significance was set at α=0.05. Results: After the exercise, significant within-group improvements in balance and gait ability were observed in both the experimental and control groups (p<0.05). There was also a significant between-group difference in balance and gait ability following the intervention (p<0.05). Conclusion: While general rehabilitation is commonly employed in treating stroke patients and is relatively effective, the application of side walking training combined with squats may offer additional benefits in terms of improving balance and gait ability in these patients.

Application and performance evaluation of mass balance method for real-time pipe burst detection in supply pipeline (도수관로 실시간 관파손감지를 위한 물수지 분석 방법 적용 및 성능평가)

  • Eunher Shin;Gimoon Jeong;Kyoungpil Kim;Taeho Choi;Seon-ha Chae;Yong Woo Cho
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.37 no.6
    • /
    • pp.347-361
    • /
    • 2023
  • Water utilities are making various efforts to reduce water losses from water networks, and an essential part of them is to recognize the moment when a pipe burst occurs during operation quickly. Several physics-based methods and data-driven analysis are applied using real-time flow and pressure data measured through a SCADA system or smart meters, and methodologies based on machining learning are currently widely studied. Water utilities should apply various approaches together to increase pipe burst detection. The most intuitive and explainable water balance method and its procedure were presented in this study, and the applicability and detection performance were evaluated by applying this approach to water supply pipelines. Based on these results, water utilities can establish a mass balance-based pipe burst detection system, give a guideline for installing new flow meters, and set the detection parameters with expected performance. The performance of the water balance analysis method is affected by the water network operation conditions, the characteristics of the installed flow meter, and event data, so there is a limit to the general use of the results in all sites. Therefore, water utilities should accumulate experience by applying the water balance method in more fields.

Utilization of Tissue Compensator for Uniform Dose Distribution in Total Body Irradiation (전신방사선조사시 균등한 선량분포를 이루기 위한 조직보상체의 이용)

  • Park, Seung-Jin;Chung, Woong-Ki;Ahn, Sung-Ja;Nam, Taek-Keun;Nah, Byung-Sik
    • Radiation Oncology Journal
    • /
    • v.12 no.2
    • /
    • pp.233-241
    • /
    • 1994
  • Purpose : This study was performed to verify dose distribution with the tissue compensator which is used for uniform dose distribution in total body irradiation(TBI). Materials and methods : The compensators were made of lead(0.8mm thickness) and aluminum(1mm or 5mm thickness) plates. The humanoid phantom of adult size was made of paraffin as a real treatment position for bilateral total body technique. The humanoid phantom was set at 360cm of source-axis distance(SAD) and irradiated with geographical field size(FS) $144{\times}144cm^2(40{\times}40cm^2$ at SAD 100cm) which covered the entire phantom. Irradiation was done with 10MV X-ray(CLINAC 1800, Varian Co., USA) of linear accelerator set at Department of Therapeutic Radiology, Chonnam University Hospital. The midline absorbed dose was checked at the various regions such as head, mouth, mid-neck, sternal notch, mid-mediastinum, xiphoid, umbilicus, pelvis, knee and ankle with or without compensator, respectively. We used exposure/exposure rate meter(model 192, Capintec Inc., USA) with ionization chamber(PR 05) for dosimetry, For the dosimetry of thorax region TLD rods of $1x1x6mm^3$ in volume(LiF, Harshaw Co., Netherland) was used at the commercially available humanoid phantom. Results : The absorbed dose of each point without tissue compensator revealed significant difference(from $-11.8\%\;to\;21.1\%$) compared with the umbilicus dose which is a dose prescription point in TBI. The absorbed dose without compensator at sternal notch including shoulder was $11.8\%$ less than the dose of umbilicus. With lead compensator the absorbed doses ranged from $+1.3\%\;to\;-5.3\%$ except mid-neck which revealed over-compensation($-7.9\%$). In case of aluminum compensator the absorbed doses were measured with less difference(from $-2.6{\%}\;to\;5.3\%$) compared with umbilicus dose. Conclusion : Both of lead and aluminum compensators applied to the skull or lower leg revealed a good compensation effect. It was recognized that boost irradiation or choosing reference point of dose prescription at sternal notch according to the lateral thickness of patient in TBI should be considered.

  • PDF

Objectively Predicting Ultimate Quality of Post-Rigor Pork Musculature: II. Practical Classification Method on the Cutting-Line

  • Joo, S.T.;Kauffman, R.G.;Warner, R.D.;Borggaard, C.;Stevenson-Barry, J.M.;Rhee, M.S.;Park, G.B.;Kim, B.C.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.13 no.1
    • /
    • pp.77-85
    • /
    • 2000
  • To investigate the practical assessing method of pork quality, 302 carcasses were selected randomly to represent commercial conditions and were probed at 24 hr postmortem (PM) by Danish Meat Quality Marbling (MQM), Hennessy Grading Probe (HGP), Sensoptic Resistance Probe (SRP) and NWK pH-K21 meter (NpH). Also, filter paper wetness (FPW), lightness (L*), ultimate pH (pHu), subjective color (SC), firmness/wetness (SF) and marbling scores (SM) were recorded. Each carcass was categorized as either PSE (pale, soft and exudative), RSE (Reddish-pink, soft and exudative), RFN (reddish-pink, firm and non-exudative) or DFD (dark, firm and dry). When discriminant analysis was used to sort carcasses into four quality groups the highest proportion of correct classes was 65% by HGP, 60% by MQM, 52% by NpH and 32% by SRP. When independent variables were combined to sort carcasses into groups the success was only 67%. When RSE and RFN groups were merged so that there were only three groups (PSE, RSE+RFN, DFD) differentiating by color MQM was able to sort the same set of data into the new set of three groups with 80% accuracy. The proportions of correct classifications for HGP, NpH and SRP were 75%, 61% and 35% respectively. There was a decline in predication accuracy when only two groups, exudative (PSE and RES) and non exudative (RFN and DFD) were sorted. However, when two groups designated PSE and non-PSE (RSE, RFN and DFD) were sorted then the proportion of correct classification by MQM, HGP, SRP and NpH were 87%, 81%, 71% and 66% respectively. Combinations of variables only increased the prediction accuracy by 1 or 2% over prediction by MQM alone. When the data was sorted into three marbling groups based on SM this was not well predicted by any of the probe measurements. The best prediction accuracy was 72% by a combination of MQM and NpH.

Behavioral reaction of hairtail (Trichinus lepturus) to different colors of LED light (LED 색광에 대한 갈치의 행동반응)

  • KIM, Mun-Kwan;AN, Young-Il;PARK, Su-Hyeon;OH, Tae-Cheol;KANG, Hyeong-Cheol;PARK, Yong-Seok
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.52 no.3
    • /
    • pp.183-190
    • /
    • 2016
  • This study carried out an experiment to find out the reaction of hairtail, Trichinus lepturus to the colors of LED light as a basic study on the development of the trolling gear and a method to enable the day-night operation. We used hairtails caught around Seongsan-po, Jeju Island by set nets and hairtail angling. The seven hairtails of the average length 68.9 cm (SD 9.2 cm) and the average weight 135.9 g (SD 47.9 g) were adapted themselves in the experimental water tank, 15 m Self-Governing 1.7 m in height and 1.5 m in depth, and then they were studied. We conducted experiment at the Ocean and Fisheries Research Institute in Jeju Special Self-Governing Province, from November to December 2015, and the sea surface temperature was between 16.5 and $19.5^{\circ}C$. The four colors of LED light, blue, white, green and red, were set up to transmit downward from the marginal area of tank. The 1 meter depth light intensity of LED colors is as follows: $0.09w/m^2/s$ (blue), $0.18w/m^2/s$ (white), $0.04w/m^2/s$ (green) and $0.007w/m^2/s$(red) To know the optimum LED color light, we selected one with better reaction rate after comparison of two colors simultaneously and the selected color was again compared to the other color in a tournament style two times a day (day and night) and ten times totally. The reaction rates were shown as the frequencies of hairtail appearance for 5 minutes in the lighting zone after turning on the LED lights. The reaction rate of the blue was at 97% unlike the red 3% (p < 0.001). The blue was at 75% unlike the green at 25% (p < 0.001). The blue was at 67% unlike the white at 33% (p < 0.001). Therefore, the color of light source showing the highest reaction rate was the blue.

A study on the Use of Low and Wet Land By Underdrainage(1) (암반비수에 의한 저온지이용에 관한 연구(1))

  • 주재홍
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.10 no.2
    • /
    • pp.1454-1459
    • /
    • 1968
  • Althow underdrainage has been studied for long time, it is the first attempt in Korea to execute using PVC(Plastic) suction pipes in the low and wet field. First, an execution plot and a control plot were set, and the drainage method and soil temprature in the excuted plot have been examined. The growth of crops and the yeild, the improvement of soil and water quality of irrigation are to be dealt during the next experimental period. The experimental method and the results obtained through the experimentations are as follows: Method 1) Depth: 1meter. interval: 5meters Trench was performed by labor. 2) PVC(plastic) sucking pipe filters were wound with glass nylon. 3) Two. horizontal looks were set in the 5a. plot. Results 1) The soil temprature in the excuted plot went up by $1.2^{\circ}C$ in average than in the control plot during the two years(1966-67) of irrigation period, and the maximum temprature raised a day was $3^{\circ}C$ 2) The under ground water level in the executed plot went down by 45cm. 3) The yield increases were 64% in potato, 57% in barley, and 21% in rice. The yield, soil, and the quality of irrigated water will be experimented during the next experemental period.

  • PDF

Study on Exposure Dose According to Change of Source to Image Distance and Additional Filter Using Abdomen Phantom (복부팬텀을 이용한 SID 변화와 부가필터 유무에 따른 피폭선량에 관한 연구)

  • Kim, Ki-Won;Son, Jin-Hyun
    • Journal of radiological science and technology
    • /
    • v.39 no.3
    • /
    • pp.407-414
    • /
    • 2016
  • This study is to minimize the patient dose and maintain the image quality according to change of source to image receptor distance and applying additional filter. In this study, we used the DR system, the tissue-equivalent abdomen phantom and the aluminium filter. The exposure conditions were set to 80 kVp using AEC mode. The collimation size was $16{\times}16inch$. The exposure dose were measured 10 times when the SID was changed with 100, 110, 120 and 130 cm, respectively. The pirana 657 for dosimeter was located on center of radiation irradiation. The acquired images were analyzed by using the image J. In the results, the tube current was increased with increasing the SID but ESD was decreased with increasing the SID. The decrease of ESD attribute to use of filter that remove the photon of lower energy. In the histogram results using image J, there were differences between the ESD and the exposure conditions according to change of SID. However, there were not differences in histogram. Therefore, the exposure dose could reduced when set the longer SID. For pediatric exam, the exposure dose could reduced when used the aluminium filter.

Relationship between the Catch of Squid, Todarodes pacificus STEENSTRUP, According to the Jigging Depth of Hooks and Underwater Illumination in Squid Jigging Boat (소형 오징어 채낚기 어선의 낚시 깊이별 조획량과 수중 조도)

  • CHOI Sok-Jin;ARAKAWA Hisayuki
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.34 no.6
    • /
    • pp.624-631
    • /
    • 2001
  • The relationship between the catch of squid, Todarodes pacificus, according to the jigging depth and underwater illumination by fishing lamps was investigated during nighttime operations off-Tusima Islands in November 1994 and off-Oki Islands in November 1995. We used echo sounder to observe the distribution of squid. Echo images on the echo sounder showed the distribution of squid at the water layer of 50 meter depth at the beginning of jigging operation. After the time elapsed, a continuous dense image had moved to the layer of 60-80 meters jigging depth. A larger number of squid were caught by jigging machines set at a lowest depth of 90 meters, when it compared with machines set at a 60 meters. However, Catch increased around 60 meters jigging depth, when fishing lamps output were switched to 24 kW halogen lights:.The underwater illumination, under the each light power of fishing lamps of squid jigging boat was continuously measured with an underwater illuminometer. Values of the underwater illumination, when schools were distributed from 60 to 80 meters, ranged from $3.0\times10^{-2}lx\;to\;3.4\times10^{-3}lx$ in average at $80\~360$ kW fishing lamps output of squid jigging boat.

  • PDF