• 제목/요약/키워드: Meter Accuracy

검색결과 262건 처리시간 0.026초

열전달 질량유량계 개발 (Development of Thermal Mass Flow Meter)

  • 지대성
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 1999년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.118-122
    • /
    • 1999
  • Thermal mass flow meter was developed using principle of convective heat transfer. The advantage of thermal mass flow meter is measuring mass flow directly, therefore, it is not required to use densitometer or temperature/pressure and DP gages. The final accuracy of this thermal mass flow meter is $\pm1.0{\%}$ or better, reproducibility is $\pm0.2{\%}$, and the response time is 600 ms. The thermal mass flow meter was developed from a single point to multi-points (maximum is 9 points), and the number of points is determined according to desired accuracy and size of piping/duct. Since this thermal mass flow meter adopted microprocessor based design, it is intrinsically accurate, self-error detectable, and has self-diagnosis function. The applications of this thermal mass flow meter are for measurement and control of HVAC air flow, other gas flow, and liquid flow.

  • PDF

Feasibility of Using the Clamp Meter in Measuring X-Ray Tube Current

  • Kim, Sung-Chul
    • International Journal of Contents
    • /
    • 제9권1호
    • /
    • pp.38-41
    • /
    • 2013
  • The clamp meter maintains electric safety as a non-invasive method while measuring the absolute value of tube current with it has been recently developed for an X-ray high-tension cable. Especially this can show high accuracy at short X-ray exposure time. Considering such a condition, this study is to evaluate the feasibility of a clamp meter in measuring X-ray tube current by taking the measurements and comparing with those of the Dynalyzer III which has been considered as a standard measuring device. From measuring the tube current accuracy depending on changes in tube voltage and exposure time, the clamp meter showed higher accuracy rate which was -1.3~4.2% difference. Thus clamp meter can be used for clinical radiologists who are not familiar electric circuit to manage X-ray devices easily and correctly in the future.

현장여건에 따른 터빈 유량계와 오리피스 유량계의 정확도 비교 (A Comparison of Accuracy Between a Turbine and an Orifice Meter in the Field)

  • 안승희;허재영
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 1999년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.97-105
    • /
    • 1999
  • Orifice flow meters are frequently used for measuring gas flow in gas industry. However, to insure the accuracy of the measurement, a certain length of the meter run at the upstream of the flow meter is required. The objective of this study is to analyze flow measurement errors of the orifice flow meter quantitatively for shorter lengths of the meter runs than those suggested in the standard manuals with variation of diameter ratio( $\beta$ ratio) and flow rate. The test results showed that the flow measurement errors of the orifice meter were inversely proportional to the diameter ratio. In other words, when the diameter ratio is 0.3 and 0.7, the measurement error is $-7.3\%$ and $-3.5\%$, respectively. the main reason of the measurement error is due to the swirl effect from the configuration of the meter run at the upstream of the flow meter. In case the length of the meter run is shorter than that suggested in the standard manuals, the swirl effect is not removed completely and it affects the flow meter's performance. As mentioned above, the less the pipe diameter ratio, the more the flow measurement error. It means that the swirl effect on the orifice meter increases as the $\beta$ ratio decreases.

  • PDF

고정밀 전력미터의 개발과 신뢰성 확보 방안에 대한 연구 (A Study on the High-Accuracy Power Meter and Reliability Verification Plan)

  • 이상훈;이창화
    • 한국멀티미디어학회논문지
    • /
    • 제20권7호
    • /
    • pp.1046-1053
    • /
    • 2017
  • We propose a design method of high accuracy power measuring device and the method of securing the reliability of the measured data. As a design method for the development of the high accuracy power measuring device, the circuit was made by reflecting the high accuracy power measuring ICs and the CT (Current Transformer). To ensure the reliability of the power meter, we requested to the watt-hour meter certified testing organization to measure the error rate, and the error rate of active power based on the "Wattmeter Technical Standard(Revision notify 2014-283)" was measure, and the error rate was confirmed to be less than 0.1%.

Accuracy Improvement of Boron Meter Adopting New Fitting Function and Multi-detector

  • Kong, Chidong;Lee, Hyunsuk;Tak, Taewoo;Lee, Deokjung;Kim, Si Hwan;Lyou, Seokjean
    • Nuclear Engineering and Technology
    • /
    • 제48권6호
    • /
    • pp.1360-1367
    • /
    • 2016
  • This paper introduces a boron meter with improved accuracy compared with other commercially available boron meters. Its design includes a new fitting function and a multi-detector. In pressurized water reactors (PWRs) in Korea, many boron meters have been used to continuously monitor boron concentration in reactor coolant. However, it is difficult to use the boron meters in practice because the measurement uncertainty is high. For this reason, there has been a strong demand for improvement in their accuracy. In this work, a boron meter evaluation model was developed, and two approaches were considered to improve the boron meter accuracy: the first approach uses a new fitting function and the second approach uses a multi-detector. With the new fitting function, the boron concentration error was decreased from 3.30 ppm to 0.73 ppm. With the multi-detector, the count signals were contaminated with noise such as field measurement data, and analyses were repeated 1,000 times to obtain average and standard deviations of the boron concentration errors. Finally, using the new fitting formulation and multi-detector together, the average error was decreased from 5.95 ppm to 1.83 ppm and its standard deviation was decreased from 0.64 ppm to 0.26 ppm. This result represents a great improvement of the boron meter accuracy.

Ka 밴드에서 Power Meter 계측 명령어에 따른 측정 정확도와 소요시간에 대한 연구 (A Study on Measurement Accuracy and Required Time based on SCPI of Power Meter in Ka Band)

  • 조태종;신석호
    • 한국인터넷방송통신학회논문지
    • /
    • 제20권5호
    • /
    • pp.51-56
    • /
    • 2020
  • 측정 명령어에 따른 정확도와 소요시간은 효율적인 Ka 밴드용 자동 시험 장비(ATE)를 구축하는데 중요한 요소이다. 이에 따라 본 논문에서는 RF 대표 계측기 Power Meter의 측정 명령어에 대해 연구하였다. 30 G ~ 31 GHz에서 Power Meter의 측정 명령어 FETCH와 MEASURE의 각 측정 레벨에 따른 정확도와 소요시간을 비교하였으며, -70 ~ +20 dBm 영역을 2가지 Power Sensor로 측정하였다. 측정 결과 신속하게 데이터를 불러오는 FETCH 명령어는 잡음 레벨보다 높은 선형 구간에서 비교적 정확한 데이터를 얻을 수 있었다. 가장 정확한 데이터를 얻을 수 있는 MEASURE 명령어는 FETCH 대비 시간이 많이 소요 되었으며, 최대 13.2초가 소요 되었다. 이를 통해 30 G ~ 31 GHz에서 Power Meter 측정 명령어의 정확도와 측정 소요시간을 확인할 수 있었고, 해당 연구 결과는 효율적인 Ka 밴드용 ATE를 구축하는데 기준을 제시할 수 있을 것으로 기대된다.

Development of accuracy enhancement system for boron meters using multisensitive detector for reactor safety

  • Sung, Si Hyeong;Kim, Hee Reyoung
    • Nuclear Engineering and Technology
    • /
    • 제52권3호
    • /
    • pp.538-543
    • /
    • 2020
  • Boric acid is used as a coolant for pressurized-water reactors, and the degree of burnup is controlled by the concentration of boric acid. Therefore, accurate measurement of the concentration of boric acid is an important factor in reactor safety. An improved system was proposed for the accurate determination of boron concentration. A new boron-concentration measurement technique, called multisensitive detection, was developed to improve the measurement accuracy of boron meters. In previous studies, laboratory-scale experiments were performed based on different sensitivity detectors, confirming a 65% better accuracy than conventional single-detector boron meters. Based on these experimental results, an experimental system simulating the coolant-circulation environment in the reactor was constructed; accuracy analysis of the boron meter with a multisensitivity detector was performed at the actual coolant pressure and temperature. In this study, the boron concentration conversion equation was derived from the calibration test, and the accuracy of the boron concentration conversion equation was examined through a repeatability test. Through the experiment, it was confirmed that the accuracy was up to 87.5% higher than the conventional single-detector boron meter.

압력센서를 이용한 디지털 콘크리트 공기량 시험기 개발에 관한 연구 (Study of Digital Air Meter Used Pressure Sensor for Air Content of Freshly Mixed Concretes)

  • 윤인준;이경문;서인호
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 춘계학술발표회 논문집(I)
    • /
    • pp.566-569
    • /
    • 2006
  • The purpose of this study is to develop digital air meter used pressure sensor for measurement of air content in freshly mixed concrete by pressure method. The digital air meter can enhanced measurement accuracy and uniformity of air content in freshly concretes, according to use of pressure sensor and measuring process automation. Finally, the digital air meter in this study is improved reproducibility and reliability of measurement compared with analog air meter.

  • PDF

저전류 측정 시스템에서의 정밀도 및 측정 속도 향상 (The Improvement of Accuracy and Measurement Speed in the Low Current Measurement System)

  • 백왕기;최인규;박종식;이경호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 합동 추계학술대회 논문집 정보 및 제어부문
    • /
    • pp.550-553
    • /
    • 2002
  • A source meter is a basic instrument to perform a measurement of DC characteristic of semiconductor devices. the source meter can be used as variable voltage source, variable current source, voltage meter, or current meter. The accuracy of the low current measurement can be improved with the compensation of leakage current and charge and discharge current. In the low current measurement, the RC time constant is extremely big, so the measurement speed is very low. In this thesis, the analysis of the behavior of the measurement current according to the RC time constant and output capacitance and the method to accelerate the measurement speed.

  • PDF

PPP 기반 항법 알고리즘을 이용한 파고 계측시스템 설계 및 구현 (Development of Wave Monitoring System using Precise Point Positioning)

  • 송세필;조득재;박슬기
    • 한국정보통신학회논문지
    • /
    • 제19권5호
    • /
    • pp.1055-1062
    • /
    • 2015
  • 본 논문에서는 GPS 위치 정보를 이용한 파고계측시스템을 제안한다. 제안한 시스템은 이중주파수 측정치 및 GPS 정밀위성정보를 이용하여 위치를 추정하는 PPP 기반 항법 알고리즘을 사용한다. 이를 이용하여 기준국으로부터 보정정보를 받는 RTK나 DGPS 기반 파고계와 달리 기준국과의 거리에 관계없이 높은 정확도로 위치 추정이 가능하다. 그리고 GPS 단독으로 운용되는 간단한 시스템이므로, 가속도계 기반 파고 계측 시스템처럼 다른 센서를 이용하여 누적되는 위치 오차를 보정할 필요가 없다. 제안한 파고계측시스템을 테스트하기 위하여 경북 울진 죽변항 인근 해역에 제안한 시스템과 기상청에서 활용하는 상용 파고계를 탑재한 부표를 설치하고, 시험 운용하였다. 그리고 부표로부터 전송된 두 가지 파고 데이터를 상호 비교함으로써 제안한 시스템의 성능을 평가하였다.