References
- J.M. Wong, Boron control in power plant reclaimed water for potable reuse, Environ. Prog. 3 (1984) 5-11. https://doi.org/10.1002/ep.670030104
- H. Kim, S.H. Lee, J.S. Park, H. Kim, Y.S. Chang, G. Heo, Reliability data update using condition monitoring and prognostics in probabilistic safety assessment, Nucl. Eng. Technol. 47 (2) (2015) 204-211. https://doi.org/10.1016/j.net.2014.12.008
- G.A. Coulman, Chemical sampling as a data filter, Can. J. Chem. Eng. 42 (6) (1964) 262-265. https://doi.org/10.1002/cjce.5450420606
- I.H. Rhee, H. Jung, D. Cho, Evaluation of pH control agents influencing on corrosion of carbon steel in secondary water chemistry condition of pressurized water reactor, Nucl. Eng. Technol. 46 (2014) 431-438. https://doi.org/10.5516/NET.09.2013.076
- M. Zubair, R. Ahmed, G. Heo, Quantitative and qualitative analysis of safety parameters in nuclear power plants, Int. J. Energy Res. 38 (6) (2014) 755-764. https://doi.org/10.1002/er.3080
- L.C. Chen, Z. Yu, H. Furuya, Y. Hashimoto, K. Takekawa, H. Suzuki, O. Ariyada, K. Hiraoka, Development of ambient sampling chemi/chemical ion source with dielectric barrier discharge, J. Mass Spectrom. 45 (8) (2010) 861-869. https://doi.org/10.1002/jms.1772
- H. Lee, S. Choi, S.H. Kim, S. Lyou, D. Lee, Performance evaluation of boron meter based on MCNPX model, in: International Symposium on Symbiotic Nuclear Power Systems for the 21th Century (ISSNP2013), 2013 Nov.
- C. Kong, H. Lee, D. Lee, S.H. Kim, S. Lyou, Sensitivity evaluation of boron meter model, in: Transactions of the Korean Nuclear Society Autumn Meeting, 2015. Gyeongju, Republic of Korea, October 29-30.
- C. Kong, H. Lee, S.H. Kim, S. Lyou, D. Lee, Application of rational function for accuracy improvement of boron meter model, in: Proceedings of the Reactor Physics Asia. 2015 Sep 16, 2015.
- C. Kong, H. Lee, S.H. Kim, S. Lyou, D. Lee, Optimization of boron meter model, in: InInternational Congress on Advances in Nuclear Power Plants (ICAPP2016), 2016 Apr 17.
- A.K. Khokonov, Y.V. Savoiskii, A.V. Kamarzaev, Neutron sensitivity and detection efficiency of 3 He and 10 BF 3 counters, Phys. At. Nucl. 73 (9) (2010) 1482-1486. https://doi.org/10.1134/S1063778810090024
- T. Qian, P. Tonner, N. Keller, W.J. Buyers, Laboratory tests of a modified 3He detector for use with startup instrumentation, in: Conference organizing committee 16, 1997, p. 210.
- S.H. Sung, H.R. Kim, Experimental characterization of the accuracy of multidetector boron meter for operational safety of reactors, Int. J. Energy Res. 42 (8) (2018) 2701-2709. https://doi.org/10.1002/er.4059
- S. Koperny, T.Z. Kowalski, Performance of proportional counters under high count rate, high gas gain and at high working gas pressure, Nucl. Phys. B Proc. Suppl. 197 (1) (2009) 370-373. https://doi.org/10.1016/j.nuclphysbps.2009.10.106
- A.S. Boiler, Pressure Vessel Committee. ASME Boiler and Pressure Vessel Code-Aan Internationally Recognized Code: Qualification Standard for Welding and Brazing Procedures, Welders, Brazers, and Welding and Brazing Operators, American Society of Mechanical Engineers, 1998.
- M.B. King, N.M. Queen, Use of rational functions for representing data, J. Chem. Eng. Data 24 (3) (1979) 178-181. https://doi.org/10.1021/je60082a001
- T. Qian, N. Keller, Degradation and life expectancy test for various BF3 Detectors, in: Annual Canadian Nuclear Society Conference, Fredericton, NB (Canada), 1996, Jun 9-12, 1996.