• Title/Summary/Keyword: Metallic artifacts

Search Result 41, Processing Time 0.029 seconds

Vertical root fracture diagnosis in teeth with metallic posts: Impact of metal artifact reduction and sharpening filters

  • Debora Costa Ruiz;Lucas P. Lopes Rosado;Rocharles Cavalcante Fontenele;Amanda Farias-Gomes;Deborah Queiroz Freitas
    • Imaging Science in Dentistry
    • /
    • v.54 no.2
    • /
    • pp.139-145
    • /
    • 2024
  • Purpose: This study examined the influence of a metal artifact reduction (MAR) tool, sharpening filters, and their combination on the diagnosis of vertical root fracture (VRF) in teeth with metallic posts using cone-beam computed tomography (CBCT). Materials and Methods: Twenty single-rooted human premolars - 9 with VRF and 11 without - were individually placed in a human mandible. A metallic post composed of a cobalt-chromium alloy was inserted into the root canal of each tooth. CBCT scans were then acquired under the following parameters: 8 mA, a 5×5 cm field of view, a voxel size of 0.085 mm, 90 kVp, and with MAR either enabled or disabled. Five oral and maxillofacial radiologists independently evaluated the CBCT exams under each MAR mode and across 3 sharpening filter conditions: no filter, Sharpen 1×, and Sharpen 2×. The diagnostic performance was quantified by the area under the receiver operating characteristic curve (AUC), sensitivity, and specificity. These metrics were compared using 2-way analysis of variance with a significance level of α=5%. Intra- and inter-examiner agreement were assessed using the weighted kappa test. Results: Neither MAR nor the application of sharpening filters significantly impacted AUC or specificity (P>0.05). However, sensitivity increased when MAR was combined with Sharpen 1× and Sharpen 2× (P=0.015). The intra-examiner agreement ranged from fair to substantial (0.34-0.66), while the inter-examiner agreement ranged from fair to moderate (0.27-0.41). Conclusion: MAR in conjunction with sharpening filters improved VRF detection; therefore, their combined use is recommended in cases of suspected VRF.

CT Number Measurement of Residual Foreign Bodies in Face (안면부에 잔류된 다양한 이물질을 측정한 CT 계수)

  • Wee, Syeo Young;Choi, Hwan Jun;Kim, Mi Sun;Choi, Chang Yong
    • Archives of Plastic Surgery
    • /
    • v.35 no.4
    • /
    • pp.423-430
    • /
    • 2008
  • Purpose: Computed tomography theoretically should improve detection of foreign bodies and provide more information of adjacent soft tissues. And the CT scanner and PACS program proved to be an excellent instrument for detection and localization of most facial foreign bodies above certain minimum levels of detectability. The severity of injury in penetrating trauma to the face, it is often underestimated by physical examination. Diagnosis of a retained foreign object is always critical. Methods: From March, 2005 to February 2008 a study was done with 200 patients who had facial trauma. Axial and coronal CT images were obtained with a General Electric(Milwaukee, Wis) 9800 CT scanner at 130 kV, 90 mA, with a 2-mm section thickness and a $512{\times}512$ matrix. Results: Axial and coronal CT images at various window widths should be used as the first imaging modality to detect facial foreign bodies. The attenuation coefficients for the metallic and nonmetallic foreign bodies ranged from -437 to +3071 HU. As a general rule, metallic foreign bodies produced more Hounsfield artifacts than nonmetallic foreign bodies, thus providing a clue to their composition. All of the metallic foreign bodies were represented by a single peak and had a maximum attenuation coefficient of +3071 HU. Of the nonmetallic foreign bodies, glass had an attenuation coefficient that ranged from +105 to +2039, while plastic had a much lower coefficient that ranged from -62 to -35. wood had the lowest range of attenuation coefficients: -491 to -437. Conclusion: The PACS program allows one to distinguish metallic from nonmetallic foreign bodies and to individually identify the specific composition of many nonmetallic foreign bodies. This program does not, however, allow identification of the specific composition of a metallic foreign body. We recommend this type of software program for CT scanning of any patient with an injury to the face in which a foreign body is suspected.

Feasibility of Improving the Accuracy of Dose Calculation Using Hybrid Computed Tomography Images: A Phantom Study

  • Jeon, Hosang;Kim, Dong Woon;Joo, Ji Hyeon;Ki, Yongkan;Kim, Wontaek;Park, Dahl;Nam, Jiho;Kim, Dong Hyeon
    • Progress in Medical Physics
    • /
    • v.32 no.1
    • /
    • pp.18-24
    • /
    • 2021
  • Purpose: Kilovoltage computed tomography (kV-CT) is essential for radiation treatment planning. However, kV-CT images are significantly distorted by artifacts when a metallic prosthesis is present in the patient's body. Thus, the accuracies of target delineation and treatment dose calculation are inevitably lowered. We evaluated the accuracy of the calculated doses using an image restoration method with hybrid CT, which was introduced in our previous study. Methods: A cylindrical phantom containing four metals, namely, silver, copper, tin, and tungsten, was scanned using kV-CT and megavoltage CT to produce hybrid CT images. We created six verification plans for three head and neck patients on kV-CT and hybrid CT images of the phantom and calculated their doses. The actual doses were measured with film patches during beam delivery using tomotherapy. We used the gamma evaluation method to compare dose distribution between kV-CT and hybrid CT with three gamma criteria, namely, 3%/3 mm, 2%/2 mm, and 1%/1 mm. Results: The gamma pass rates decreased as the gamma criteria were strengthened, and the pass rate of hybrid CT was higher than that of kV-CT in all cases. When the 1%/1 mm criterion was used, the difference in gamma pass rates between them was up to 13%p. Conclusions: According to our findings, we expect that the use of hybrid CT can be a suitable approach to avoid the effect of severe metal artifacts on the accuracy of dose calculation and contouring.

The Study on the Weathering Characteristics about Epoxy Adhesive for the Adhesion and Restoration of Metallic Cultural Assets (금속문화재 접합 복원용 에폭시 접착제의 내후성 연구)

  • Lee, Ji-Hyun;Wi, Koang-Chul
    • Journal of Conservation Science
    • /
    • v.26 no.1
    • /
    • pp.61-67
    • /
    • 2010
  • After selecting five types of adhesive epoxy resin for metallic cultural assets such as $Araldite^{(R)}$ rapid type, $Devcon^{(R)}$, $Araldite^{(R)}$ SV427+HV427, $CDK^{(R)}$520, $Araldite^{(R)}$ AW106+HV953 which had already been studied, this paper approached more closely the problem of yellowing and the signal of aging with time passing by connecting the problems with the safety of metallic cultural assets. The change of physical properties according to the change of state of epoxy adhesives was investigated through the change of flexural strength and the change of surface hardness by artificially providing the possible environmental change factors such as ultra-violet ray, and acid base, and how the epoxy chemically changes in its ingredients by the environment was analyzed through FT-IR. As a result of the experiment, for the most part of adhesives brought about the physical change of flexural strength, the change of surface hardness, and the chemical change of chemical ingredients as the product of alcohol, which were respectively different according to the time of ultraviolet irradiation, and acid base change. Under most of the conditions, SV427+HV427 and $CDK^{(R)}$520 were fairly stabilized under each condition of weatherability, but it seems that they should be refrained from being applied in case that the area to restore is thin and wide because the degree of flexural strength of themselves is low. Also, it is found that the preservation environment is very important not only for artifacts but also for the preservation of resins sused for preservation treatment.

Material Characteristics of Gold Artifacts of Sarira Reliquary inside Stone Pagoda of Mireuksa Temple Site (미륵사지 석탑 출토 사리장엄 금제유물의 재료학적 특성)

  • Kwon, Hyuk-nam;Yoo, Dong-wan;Lee, Jang-jon;Han, Min-su
    • Korean Journal of Heritage: History & Science
    • /
    • v.47 no.4
    • /
    • pp.210-223
    • /
    • 2014
  • When sarira reliquary was found in stone pagoda of Mireuksa Temple, there were 494 gold artifacts, including inner gold pot, gold plate with inscription for Sarira enshrinement, etc. Most of gold artifacts were crafted, but there were 22 gold plates and 4 gold ingots, which did not have any specific shape. It was considered that they had not been crafted. Since gold exists as a metal rather than a metallic oxide in nature, in general, it can be crafted by melting and shaping. However, gold in nature has impurities so it has to be refined to have malleability. The characteristic features were identified through the analysis of gold artifacts from sarira reliquary found in stone pagoda of Mireuksa Temple. The analysis result showed that there were 3 types of gold; pure gold artifacts, artifacts produced with silver containing gold and natural gold ingots. Inner gold pot, gold earrings and gold small beads were produced with pure gold and they contained less than 1wt.% of copper. It seemed like they were produced as pure gold to be shaped by hammering. Gold plate with inscription, tweezers, gold earrings, ingots, etc. were produced with silver containing gold as they had to be more solid. Gold ingots seemed to be natural gold considering the distribution of silver and copper in them, but it cannot be concluded as there are not enough information on gold ingots in Korea. The comprehensive research on gold ingots from various regions in Korea has to be carried out to confirm the above. Sarira Reliquary showed the very sophisticated gold craftsmanship. Gold ingots with the inscriptions, which say 1 nyang, were approximately 14g. Considering the weight of these ingots as standard, weights of other ingots were half nyang(7g), 2 nyang(28g), etc.

An Assessment Study on Stability of Various Coating Treatment of Metallic Artifacts Using V-Flon (불소 수지(V-Flon)를 이용한 금속유물의 코팅 형성에 대한 안전성 평가 연구)

  • Lee, Jung-Min;Wi, Koang-Chul
    • Journal of Conservation Science
    • /
    • v.26 no.2
    • /
    • pp.149-156
    • /
    • 2010
  • One of resins, V-Flon is useful as a coating material because YK-D80, which is a solvent for V-Flon, is not highly volatile. However, it can not completely harden and can flow out when metal artifacts are joined and restored in the process of the treatment. Therefore, after the impregnation process in order to accelerate the hardening speed of a coating material, usually a dry oven was adopted. This study focused on finding the problems on the dry oven which is employed to increase the speed and investigating the most effective solvent and its composition by checking any change occurred depending on the concentration of solvents. Six different types of solvents were selected and samples were prepared in a manner that they were impregnated with solvents in three concentrations respectively (10%, 20%, 30%). To determine the condition of the samples, the stability evaluation was performed by measuring the change of color and the gloss, the thickness of coated layers, the corrosion after coating, the water resistance by contact angles. Through the comparative experiments between the natural drying and the artificial drying using a dry oven, it was found that when the dry oven is used, some problems are identified on the point of forming a uniform and stable layer because of the unstable data collected from the forced artificial dry. The experiments performed using 3 different concentration rates (10%, 20%, 30%) presented that in the case of 10% V-Flon in Xylene (using as a solvent), its layer was thin as well as it showed the high water-barrier property, which allows it to form the stably coated layer with the lower gloss and color change.

Three-dimensional digital recording of the conservation treatment and form analysis of an iron ring pommel (철제 환두부 보존처리 과정의 3차원 디지털기록 및 형상변화 분석)

  • Choi, Hyoryeong;Hong, Seonghyuk;Jo, Younghoon;Cho, Namchul
    • Conservation Science in Museum
    • /
    • v.25
    • /
    • pp.85-94
    • /
    • 2021
  • Conservation treatment of metallic artifacts contaminated with corrosion and foreign substances requires changes in the shape, characteristics, weight and thickness of the artifacts. Thus far, recording the changes after conservation treatment has mainly been performed through visual observation and photography, which lacks any quantitative description of the changes. In this study, the processes of removing foreign substances, joining cracks, and restoring an affected area were recorded using 3D scanning and then quantitatively analyzed to identify changes in form due to conservation treatment. The volume change after the conservation process was calculated based on the results of the 3D scanning, and numerical data on the changes to the form was analyzed. It was revealed that the foreign or corroded substances removed after the conservation accounted for 18.1 cm3, which is approximately 52% of the total volume of the ring pommel, and those substances were removed from about 98% of the surface of the ring pommel. This study confirmed that 3D form analysis was useful for recording the processes of conservation treatment and analyzing the results. It is therefore believed that this methodology can be applicable to not only metal artifacts, but to cultural heritage items in a range of materials.

Scientific Analysis of Metal in Chinese and Korean Traditional Gold Thread (중국과 한국 전통금사 금속의 과학적 분석 연구)

  • Jeong, Seon Hye;Yu, Ji A;Chung, Yong Jae;Sim, Yeon Ok
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.37 no.6
    • /
    • pp.764-771
    • /
    • 2013
  • The metal component of Chinese and Korean traditional gold thread was analyzed nondestructively using P-XRF and classified morphologically. In the nondestructive analysis of 22 Chinese and Korean artifacts, there were 10 gold threads made up of Au in China and 7 in Korea; in addition, there were 4 silver threads made up of Ag in Korea and 1 copper thread made up of Cu in China. In the morphological classification, 7 gilt paper strips were confirmed in China and Korea and 4 wrapped threads were identified in China and Korea. Zn, Sn and Fe (minor components of the threads) were detected. These components were assumed to be transferred from the metal found in burial goods.

Packet Loss Concealment Algorithm Based on Robust Voice Classification in Noise Environment (잡음환경에 강인한 음성분류기반의 패킷손실 은닉 알고리즘)

  • Kim, Hyoung-Gook;Ryu, Sang-Hyeon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.33 no.1
    • /
    • pp.75-80
    • /
    • 2014
  • The quality of real-time Voice over Internet Protocol (VoIP) network is affected by network impariments such as delays, jitters, and packet loss. This paper proposes a packet loss concealment algorithm based on voice classification for enhancing VoIP speech quality. In the proposed method, arriving packets are classified by an adaptive thresholding approach based on the analysis of multiple features of short signal segments. The excellent classification results are used in the packet loss concealment. Additionally, linear prediction-based packet loss concealment delivers high voice quality by alleviating the metallic artifacts due to concealing consecutive packet loss or recovering lost packet.

Image Evaluation Analysis of CT Examination for Pedicle Screw Insertion (척추경 나사못 삽입술 CT검사의 영상평가 분석)

  • Hwang, Hyung-Suk;Im, In-Chul
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.2
    • /
    • pp.131-139
    • /
    • 2022
  • The purpose of this study was to insert a pedicle screw into a pig thoracic vertebrae, a general CT scan(Non MAR), and a thoracic axial image obtained with the Metallic Artifact Reduction for Orthopedic Implants (O-MAR) to reduce artifacts. The image obtained by reconstructing the algorithm (Standard, Soft, Bone, Detail) was used using the image J program. Signal to noise ratio(SNR) and contrast to noise ratio(CNR) were compared and analyzed by obtaining measured values based on the given equation. And this study was to investigate tube voltage and algorithm suitable for CT scan for thoracic pedicle screw insertion. As a result, when non-MAR was used, the soft algorithm showed the highest SNR and CNR at 80, 100, 120, and 140 kVp, On the other hand, when MAR was used, the standard algorithm showed the highest at 80 kVp, and the standard and soft algorithms showed similar values at 100 kVp. At 120 kVp, the Soft and Standard algorithms showed similar values, and at 140 kVp, the Soft algorithm showed the highest SNR and CNR. Therefore, when comparing Non-MAR and MAR, even if MAR was used, SNR and CNR did not increase in all algorithms according to the change in tube voltage. In conclusion, it is judged that it is advantageous to use the Soft algorithm at 80, 100, 120, and 140 kVp in Non MAR, the Standard algorithm at 80 and 100 kVp in MAR, and the Soft algorithm at 120 and 140 kVp. This study is expected to serve as an opportunity to further improve the quality of images by using selective tube voltage and algorithms as basic data to help evaluate images of pedicle screw CT scans in the future.