• Title/Summary/Keyword: Metal sample

Search Result 843, Processing Time 0.026 seconds

Improving Interface Characteristics of Al2O3-Based Metal-Insulator-Semiconductor(MIS) Diodes Using H2O Prepulse Treatment by Atomic Layer Deposition

  • Kim, Hogyoung;Kim, Min Soo;Ryu, Sung Yeon;Choi, Byung Joon
    • Korean Journal of Materials Research
    • /
    • v.27 no.7
    • /
    • pp.364-368
    • /
    • 2017
  • We performed temperature dependent current-voltage (I-V) measurements to characterize the electrical properties of $Au/Al_2O_3/n-Ge$ metal-insulator-semiconductor (MIS) diodes prepared with and without $H_2O$ prepulse treatment by atomic layer deposition (ALD). By considering the thickness of the $Al_2O_3$ interlayer, the barrier height for the treated sample was found to be 0.61 eV, similar to those of Au/n-Ge Schottky diodes. The thermionic emission (TE) model with barrier inhomogeneity explained the final state of the treated sample well. Compared to the untreated sample, the treated sample was found to have improved diode characteristics for both forward and reverse bias conditions. These results were associated with the reduction of charge trapping and interface states near the $Ge/Al_2O_3$ interface.

Spectrometer for the Study of Angle-and Energy-Resolved Reactive Ion Scattering at Surfaces

  • S-J. Han;C.-W. Lee;C.-H. Hwang;K.-H. Lee;M. C. Yang;H. Kang
    • Bulletin of the Korean Chemical Society
    • /
    • v.22 no.8
    • /
    • pp.883-888
    • /
    • 2001
  • We describe an ion-surface scattering apparatus newly developed to investigate the reactive scattering process of low-energy alkali-metal ions at surfaces. The apparatus consists of an alkali-metal ion gun that is rotatable by 360°, a quadrupole mass spectrometer (QMS) with an ion energy analyzer, a sample manipulator with a heating-and-cooling stage, and an ultrahigh vacuum (UHV) chamber that houses these components. Preliminary experimental results obtained from the apparatus are presented on angular and energy distributions of the ions scattered from clean Pt(111) and water-adsorbed Pt surfaces.

Determination of Zinc and Lead in Water Samples by Solvent Sublation Using Ion Pairing of Metal-Naphthoate Complexes and Tetra-n-butylammonium Ion

  • Kim, Yeong Sang;Choe, Yun Seok;Lee, Won;Lee, Yong Il
    • Bulletin of the Korean Chemical Society
    • /
    • v.22 no.8
    • /
    • pp.821-826
    • /
    • 2001
  • Solvent sublation has been studied for the separation and determination of trace Zn(Ⅱ) and Pb(Ⅱ) in water samples. A synergy producing method was utilized to improve the efficiency of extraction in the sublation using an ion-pair of metal-naphth oate {M-(Nph)3- } complexes and tetra-n-butylammonium (TBA+ ) ion. After the M-(Nph)3- complexes were formed by adding 1-naphthoic acid to the sample solution, tetra-n-butylammonium bromide was added in the solution to form the ion-pair. And sodium lauryl sulfate (SLS) was added to make the ion-pair hydrophobic. The ion-pairs of the metal complexes were floated and extracted into methylisobutyl ketone (MIBK) from the aqueous solution by bubbling with nitrogen gas in a flotation cell. Metal ions in MIBK solution were measured by graphite furnace-AAS. Experimental conditions were optimized as follow so. After the pH of a 1.0 L water sample was adjusted to 5.0, 6.0 mL of 0.1 M 1-HNph and 10 mL of 0.03 M TBA-bromide were added to the sample to form ion-pairs, and 2.0 mL of 0.2%(w/v) SLS was added to make the ion-pairs hydrophobic. The solution was bubbled with 30 mL/min N2 gas for 5 minutes in a flotation cell. Linear calibration curves were obtained for the determination of Zn(Ⅱ) and Pb(Ⅱ) in several water samples. Reproducible results of showing a relative standard deviation of < 10% and recoveries of 80-100% could be obtained.

Sample Pretreatment for the Determination of Metal Impurities in Silicon Wafer (실리콘 웨이퍼 중의 금속 불순물 분석을 위한 시료 전처리)

  • Chung, H.Y.;Kim, Y. H.;Yoo, H.D.;Lee, S.H.
    • Journal of the Korean Chemical Society
    • /
    • v.43 no.4
    • /
    • pp.412-417
    • /
    • 1999
  • The analytical results obtained by microwave digestion and acid digestion methods for sample pretreatment to determine metal impurities in silicon wafer by inductively coupled plasma-mass spectrometry (ICP-MS) were compared. In order to decompose the silicon wafer, a mixed solution of $HNO_3$ and HF was added to the sample and the metal elements were determined after removing the silicon matrix by evaporating silicon in the form of Si-F. The recovery percentages of Ni,Cr and Fe were found to be 95∼106% for both microwave digestion and acid digestion methods. The recovery percentage of Cu obtained by the acid digestion method was higher than that obtained by the microwave digestion method. For Zn, however, the microwave digestion method gave better result than the acid digestion method. Fe was added to a silicon wafer using a spin coater. The concentration of Fe in this sample was determined by lCP-MS, and the same results were obtained in the two pretreatment methods.

  • PDF

Preparation and Properties of Waterborne Poly(urethane-urea) Ionomers -Effect of the Type of Neutralizing Agent-

  • Yang, Jung-Eun;Lee, Young-Hee;Koo, Young-Seok;Jung, Young-Jin;Kim, Han-Do
    • Fibers and Polymers
    • /
    • v.3 no.3
    • /
    • pp.97-102
    • /
    • 2002
  • A series of waterbome poly(urethane-urea) anionomers were prepared from isophorone diisocyanate (IPDI), polycaprolactone diol (PCL), dimethylol propionic acid (DMPA), ethylene diamine (EDA), and triethylamine (TEA), NaOH, or Cu($(COOCH_3)_2$) as neutralizing agent. This study was performed to decide the effect of neutralizing agent type on the particle size viscosity, hydrogen bonding index, adhesive strength, antistaticity, antibacterial and mechanical properties. The particle size of the dispersions decreased in the following order: TEA based samples (T-sample), NaOH based samples (N-sample), and Cu($(COOCH_3)_2$) based sample (C-sample). The viscosity of the dispersions increased in the order of C-sample, N-sample, and T-sample. Metal salt based film samples Of and C-sample) had much higher antistaticity than TEA based sample. By infrared spectroscopy, it was found that the hydrogen bonding index (or fraction) of samples decreased in the order of T-sam-pie, N-sample, and C-sample. The adhesive strength and tensile modulus/strength decreased in the order of T-sample, N-sam-pie, and C-sample. The C-sample had strong antibacterial halo, however, T- and N-samples did not

Influence of metal annealing deposited on oxide layer

  • Kim, Eung-Soo;Cho, Won-Ju;Kwon, Hyuk-Choon;Kang, Shin-Won
    • Proceedings of the IEEK Conference
    • /
    • 2002.07a
    • /
    • pp.365-368
    • /
    • 2002
  • We investigated the influence of RTP annealing of multi-layered metal films deposited on oxides layer. Two types of oxides, BPSG and P-7205, were used as a bottom layer under multi-layered metal film. The bonding was not good in metal/BPSG/Si samples because adhesion between metal layer and BPSG oxide layer was poor by interfacial reaction during RTP annealing above 650$^{\circ}C$. On the other hand bonding was always good in metal/ P-TEOS /Si samples regardless of annealing temperature. We observed the interface between oxide and metal layers using AES and TEM. The phosphorus and oxygen profile in interface between metal and oxide layers were different in metal/BPSG/Si and metal/P-TEOS/Si samples. We have known that the properties of interface was improved in metal/BPSG/Si samples when the sample was annealed below 650$^{\circ}C$.

  • PDF

Monitoring of Heavy Metal Contents in Commercial Herbal Medicines in Korea: Cultivated Herbal Medicines in the Seoul and Daegu Areas (국내 유통 한약재의 중금속 함량 모니터링 -서울과 대구지역 한약재 중심으로 -)

  • Jang, Seol;Lee, Ah-Reum;Lee, A-Eong;Choi, Go-Ya;Kim, Ho-Kyoung
    • Journal of Environmental Health Sciences
    • /
    • v.41 no.1
    • /
    • pp.30-39
    • /
    • 2015
  • Objectives: This study was conducted to determine the heavy metal contents in commercial herbal medicines in Korea. Methods: Monitoring of lead, arsenic, cadmium and mercury was carried out on 116 samples of eleven types of herbal medicines. Among the total samples, 71 samples were domestic and 45 were imported. The samples were digested using the microwave method. The heavy metal contents were measured by inductively coupled plasma atomic emission spectrometry (ICP-AES) and a mercury analyzer. ICP-AES was used to analyze lead, arsenic cadmium. Mercury was analyzed by the amalgamation method. Results: The mean values of the heavy metal contents in the herbal medicines were Pb 0.64mg/kg, As 0.26mg/kg, Cd 0.07mg/kg and Hg 0.004mg/kg. Of the total samples, one violated the MFDS (Ministry of Food and Drug Safety) regulatory guidance on heavy metals in herbal medicines. Lead was detected at more than 5mg/kg in one sample. The measured values of arsenic, cadmium and mercury in the herbal medicines showed levels lower than the recommended levels for herbal medicines in MFDS regulatory guidance. In the comparison of domestic samples with imported herbal medicines, it was found that one domestic sample surpassed the maximum residue limits for lead. Conclusion: These results will be used to establish the regulation and control of heavy metal contents in herbal medicines. In addition, continuous monitoring is needed to ensure confidence in and the safety of these herbal medicines.

MARGINAL FIT OF THE DIGIDENT CAD/CAM ZIRCONIA CERAMIC CROWNS

  • Kim Yong-Sun;Yang Jae-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.3
    • /
    • pp.275-283
    • /
    • 2006
  • Statement of problem. There have been many studies about marginal discrepancy of single restorations made by various systems and materials. However most of the statistical inferences are not definite because of sample size, measurement number, measuring instruments, etc, and there have been few studies about the marginal fit of the Digident CAD/ CAM zirconia ceramic crowns. Purpose. The purpose of this study was to compare the marginal fit of the anterior single restorations made by using the Digident CAD / CAM zirconia ceramic crowns with metal-ceramic restorations and to obtain more accurate information by using a large enough sample size and by making sufficient measurements per specimen. Material and Methods. The crowns were made from one extracted maxillary central incisor pre-pared with a 1mm shoulder margin and $6^{\circ}$ taper walls by milling machine. The in vitro marginal discrepancies of the digident CAD / CAM zirconia ceramic crowns and control groups(metal ceramic crowns) were evaluated and compared. Twenty crowns per each system were fabricated. Measurements of a crown were recorded at 50 points that were randomly selected for marginal gap evaluation. Parametric statistical analysis was performed for the results. Conclusion. Within the limitations of this in vitro study, the following conclusions were drawn: 1. Mean gap dimensions and standard deviations at the marginal opening for maxillary incisal crowns were $88{\pm}10{\mu}m$ for the control (metal-ceramic crowns), $92{\pm}4{\mu}m$ for Digident CAD / CAM zirconia ceramic crowns. 2. Marginal gap between Digident CAD / CAM zirconia ceramic crowns and metal ceramic crowns did not show significant difference (P>.05). 3. The Digident CAD/ CAM zirconia ceramic crowns and metal ceramic crowns showed clinically acceptable marginal discrepancy.

Analysis on effect of heavy metal and Retention time to nitrification using industrial wastewater (중금속과 체류시간이 산업단지하수 질산화에 미치는 영향)

  • Im, Jiyeol;Gil, Kyungik
    • Journal of Wetlands Research
    • /
    • v.20 no.4
    • /
    • pp.390-397
    • /
    • 2018
  • The Municipal Wastewater Treatment Plant(MWTP), located industrial estate, has a problem of decreasing nitrification efficiency. In this research, it was analyzed that effect of heavy metals and retention time to nitrification based on operational result of laboratory scale reactors. And suggest improving MWTP operation method for increasing nitrification efficiency based on findings. According to operational result, laboratory scale reactor shows over 60% nitrification efficiency over hydraulic retention time(HRT) 0.5 day. However, the nitrification efficiency of S MWTP(high heavy metal concentration) sample was lower than that of A MWTP(low heavy metal concentration) sample in same operational condition. The main reason was heavy metals in industrial wastewater. This heavy metals was acted as inhibitor to nitrifier in reactors. So, activity of nitrifier was analyzed based on specific nitrification rate(SNR). The SNR of S MWTP sample shows 0.13 ~ 0.21 mg NH4/gMLSS/hr and that of A MWTP sample shows 0.74 mg NH4/gMLSS/hr. As a result, the activity of nitrifier of S MWTP was lower than that of A MWPT. In other words, retrofit methods for improving nitrification efficiency in MWTPs located industrial estate were that to increase retention time in biological treatment process or to pretreat heavy metal before being injected biological treatment process.

Removal of Heavy Metal Ions by Using Natural Zeolite Comixed with Montmorillonite (Montmorillonite가 섞인 천연 제올라이트를 이용한 중금속 이온의 제거)

  • Moon, Jung-Ho;Kim, Yoonho;Kim, Young-Man;Kim, Chon-Han;Kwak, Hyon-Tae
    • Analytical Science and Technology
    • /
    • v.13 no.3
    • /
    • pp.394-398
    • /
    • 2000
  • The mineralogical properties of natural zeolite comixed with montmorillonite were investigated by the chemical composition analysis, X-ray diffraction analysis, and differential scanning calorimetry. The experimental results on the removal of heavy metal ions by using the natural sample are summerized as follows. The removal of the heavy metal in solution is greatly influenced by the pH. Also, the removal capacity of heavy metal ions by zeolite and montmorillonite have increased in order of $Cu^{2+}>Cd^{2+}>Ni^{2+}$.

  • PDF