• Title/Summary/Keyword: Met Tower

Search Result 16, Processing Time 0.022 seconds

Analysis of the Effect of Met Tower Shadow using Computational Fluid Dynamics (전산유체역학을 이용한 풍황탑 차폐효과 해석)

  • Kim, Taesung;Rhee, Huinam;Kim, Hyun-Goo
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.35.1-35.1
    • /
    • 2011
  • When the wind speed is measured by the met-mast sensor it is distorted due to the shadow effect of tower. In this paper the tower shadow effect is analyzed by a computational fluid dynamics code. First three dimensional modeling and flow analysis of the met-mast system were performed. The results were compared with the available experimental wind-tunnel test data to confirm the validity of the meshes and turbulence model. Two-dimensional model was then developed based on the three-dimensional works and experimental data. 2D analysis for various Reynolds numbers and turbulence strengths were then performed to establish the tower shadow effect database, which can be utilized as correction factors for the measured wind energy.

  • PDF

A Study on Design of Offshore Meteorological Tower (해상기상탑 설계에 관한 연구)

  • Moon, Chae-Joo;Chang, Young-Hak;Park, Tae-Sik;Jeong, Moon-Seon;Joo, Hyo-Joon;Kwon, O-Soon;Kwag, Dae-Jin;Jeong, Gwon-Seong
    • Journal of the Korean Solar Energy Society
    • /
    • v.34 no.2
    • /
    • pp.60-65
    • /
    • 2014
  • A meteorological(met) tower is the first structure installed during the planning stages of offshore wind farm. The purpose of this paper is to design the met tower with tripod bucket type support structure and to install the sensors. The support structure consist of a central steel shaft connected to three cylindrical steel suction buckets which is more cheaper than monopile or jacket type. And the remote wind condition sensors and marine monitoring equipment, including adcp, pressure type tide gauge, wave height sensors, and scour sensors, remote power supply are installed. The manufactured met tower constructed on sea area which is in front of Gasa island. All of functions of met tower showed normal operation conditions and the wind data got by remote data collection system successfully.

Met-tower Shading Correction Program KIER-$ShadeFree^{TM}$ (풍황탑 차폐영향 보정 프로그램 KIER-$ShadeFree^{TM}$)

  • Kim, Hyun-Goo;Jeong, Tae-Yoon;Jang, Moon-Seok;Jeon, Wan-Ho;Yoon, Seong-Wook
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.11a
    • /
    • pp.190.1-190.1
    • /
    • 2010
  • 풍력자원평가를 위해 풍력단지 개발대상지의 국지풍황 대표지점에 설치하는 풍황탑(met-tower 또는 풍황마스트; met-mast)은 모노폴(monopole), 삼각단면 트러스 또는 사각단면 트러스 구조를 갖는다. 풍향계 및 풍속계는 이러한 지지구조물에 의한 풍속의 교란 또는 차폐영향을 최소화하기 위하여 긴 붐(boom)의 끝단에 설치되지만 계측기가 풍황탑의 직후방 후류영역에 놓이게 될 경우 차폐영향을 완전히 피하기는 어렵다. 저자들의 선행연구에 따르면 풍황탑 차폐영향은 평균풍력밀도의 경우 2.5% 이상의 오차를 유발할 수 있으므로 풍력자원평가 시 필히 고려되어야 할 불확도 요인인 것이다. 이에 한국에너지기술연구원에서는 풍황탑 주위의 대기유동장을 전산유동해석을 이용하여 차폐영향의 정도를 정량적으로 수치모사함으로써 이를 보정하는 기술을 개발한 바 있다(현재 특허심사 중). KIER-$ShadeFree^{TM}$는 이 특허기술을 프로그램화 한 것으로, 시범적으로 다수의 풍황탑 풍력자원 측정자료에 적용하여 상당한 보정효과에 의한 풍력자원평가의 정확도 향상효과를 볼 수 있었다.

  • PDF

An Analysis on Micro-climate Characteristic of Apartments in Beijing, China Using ENVI-met Simulation (ENVI-met를 이용한 중국 베이징 아파트 하절기 미기후 특성 분석)

  • Wu, Jin-Dong;Lee, Jun-Hoo;Yoon, Seong-Hwan
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.35 no.8
    • /
    • pp.169-176
    • /
    • 2019
  • The purpose of this study was to analyze outdoor thermal comfort of apartments planning characteristic of pedestrian height in Beijing, China. Selecting 322 apartment complexes with more than 1000 households and more than 10 buildings(including 10 buildings), mainly in Chaoyang District and Tongzhou District to select 32 basic layout types and then 12 typical layout types were select in 32 basic layout types. Finally, the simulation was conducted for the 12 typical layout types using the micro-climate model ENVI-met to evaluate the wind environment, the thermal environment and the comfort. The results of this study as follows: In the parallel arrangement, it has the best outdoor thermal comfort of Slab-East-Parallel(S/E/P). Next is Slab-South-Parallel(S/S/P), Tower-South-Parallel(T/S/P) in turn. In the stagger arrangement, Mixture-South-North and South Stagger-1(M/S/NSS-1) has the best outdoor thermal comfort and Slab-South-North and South Stagger(S/S/NSS), Tower-South-North and South Stagger(T/S/NSS), Mixture-South-North and South Stagger-3(M/S/NSS-3), Mixture-South-North and South Stagger-4(M/S/NSS-4), Mixture-South-North and South Stagger-2(M/S/NSS-2) in turn. In the cluster arrangement, Mixture-Mixture-Cluster-2(M/M/C-2) has the best outdoor thermal comfort and Mixture-Mixture-Cluster-3(M/M/C-3), Mixture-Mixture-Cluster-1(M/M/C-1) in turn. Due to the low wind speed and high air temperature, it is necessary to consider the layout types that can form the wind road at first, such as Mixture-South-North and South Stagger-1(M/S/NSS-1), Slab-South-North and South Stagger(S/S/NSS) and so on.

Three-Dimensional Computational Flow Analysis on Meteorological-Tower Shading Effect (풍황탑 차폐영향 분석을 위한 3차원 전산유동해석)

  • Rhee, Hui-Nam;Kim, Tae-Sung;Jeon, Wan-Ho;Kim, Hyun-Goo
    • Journal of the Korean Solar Energy Society
    • /
    • v.33 no.1
    • /
    • pp.1-6
    • /
    • 2013
  • It is difficult to avoid measurement errors caused by the shading effect of the meteorological tower, which is used for wind resource assessment according to the IEC Standard. This paper presents a validation of the computational flow analysis results by comparing the results with the wind tunnel experiment conducted for Reynolds numbers in the $10^4$ to $10^5$ range, for the preparation of a database for use in an automatic method of correcting met-tower shading errors. A three-dimensional simulation employing the MP (Modified Production) $k-{\varepsilon}$ turbulence model predicted a wind speed deficit in the wake region according to minimum wind speed ratio, within an MAE (Mean Absolute Error) of 2.4%.

Korean Female Adolescents' Food Attitudes and Food Intake Relative to the Korean Food Tower (I) : Food Intake

  • Kim, Kyeung-Eun;Resalie J. Amos
    • Journal of Community Nutrition
    • /
    • v.4 no.3
    • /
    • pp.164-179
    • /
    • 2002
  • A survey was conducted to examine the food intake of 285 Korean female students attending a secondary school in Seoul. Food intake was assessed using a food frequency based on the Korean Food Tower which consists of five food groups, i.e., grain products, vegetables and fruits, meat, milk, and fats and sweets. To describe food intake descriptive statistics were obtained using SPSS. The food frequency analysis indicated that the participants ate rice, cabbage kimchi, radish, and soybean/red pepper paste most frequently along with milk, ice cream, tea, and seasonal fruits such as citrus fruits, apples, watermelon, and grapes for snacks. Distributions of the total standardized serving frequency for each food group indicated that approximately 84, 83, 45, 60, and 34%, respectively, of the respondents met the recommended serving frequency for grain products, vegetables and fruits, meat, milk, and fats and sweets groups(mean servings per day 5.5, 10.6, 5.5, 2.1, 3.5). Income was the only demographic factor that affected food intake, particularly with respect to meat, milk, and fats and sweets(p < .01). In Korea, these food groups are generally more expensive than the other ones. (J Community Nutrition 4(3) : 164∼179, 2002)

Wind Environment Assessment of Walrjeong Station Using Computational Fluid Dynamics (전산유체역학을 이용한 월정기지 풍환경 평가)

  • Lee, Yong-Jin;Kim, Hyun-Goo
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.489-490
    • /
    • 2009
  • We investigated wind environment impact of the building of the KIER Waljeong Station in Jeju Island. From the preliminary qualitative analysis using the VirtualWind simulator, we confirmed that an influence caused by the 11m-tall 30m-aparted building on the 1.5MW wind turbine at Waljeong Station in not negligible. As a next step, VirtualWind simulation and the 100m met-tower measurement at the Waljeong Station is going to be compared to identify a building effect quantitatively.

  • PDF

The Development of the Monitoring System for Wind resource measurement in onshore wind energy experimental research complex (육상풍력실증연구단지 풍황계측 모니터링 시스템 개발)

  • Ko, Seok-Whan;Jang, Moon-Seok;Lee, Youn-Seop
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.04a
    • /
    • pp.277-280
    • /
    • 2009
  • Wind monitoring system is an absolutely-required system for assessing a performance and fatigue load of the wind energy generator in an on-shore wind energy experimental research complex. It was implemented for the purpose of monitoring the wind information measured from a meteorological tower at the monitoring house and of utilizing the measured data for the performance assessment, by using the LabVIEW program. Then, by adding the performance assessment-related data acquired from the wind energy generator during the performance assessment and the data recorder for synchronizing the data of meteorological tower, the system was implemented. Because it transmitted the data by converting the output 'RS-232' of data logger which measures the wind condition into CAN protocol, the data error rate was minimized, This paper is intended to explain the developed wind data monitoring system.

  • PDF

The Development of the Monitoring System for Power performance using the Lab View (LabView를 이용한 풍력발전 성능평가용 모니터링 시스템 개발)

  • Ko, Seok-Whan;Jang, Moon-Seok;Ju, Young-Chul;Lee, Yoon-Sub
    • Journal of the Korean Solar Energy Society
    • /
    • v.29 no.6
    • /
    • pp.69-74
    • /
    • 2009
  • Monitoring system is an absolutely-required system for assessing a performance and fatigue load of the wind turbine in an on-shore wind energy experimental research complex. It was implemented for the purpose of monitoring the wind information measured from a meteorological tower at the monitoring house, and of utilizing the measured data(fatigue data and electric analyzing data of wind turbine)for the performance assessment, by using the LabVIEW program. Then, by adding the performance assessment-related data acquired from the wind turbine during the performance assessment and the data recorder for synchronizing the data of meteorological tower, the system(BusDAQ) was implemented. Because it transmitted the data by converting the output 'RS-232' of data logger which measures the wind condition into CAN protocol, the data error rate was minimized. Also, This paper is introduced to make the best use of the developed monitoring system and to explain about construct of the system and detailed data communication of its system.

Meteor-Statistical Analysis for Establishment of Jejudo Wind Resource Database (제주도 풍력자원 데이터베이스 구축을 위한 기상통계분석)

  • Kim, Hyun-Goo;Jang, Moon-Seok;Lee, Eon-Jeong
    • Journal of Environmental Science International
    • /
    • v.17 no.6
    • /
    • pp.591-599
    • /
    • 2008
  • In order to support the development of wind farms in Jejudo, a wind resource database for Jejudo has been established using a meteor-statistical analysis of KIER(Korea Institute of Energy Research) met-mast measurements and KMA(Korea Meteorological Administration) weather data. The analysis included wind statistics, tower shading, an exposure category classification using satellite images, the effect of atmospheric stability on the wind profile exponent, and a correlation matrix of wind speed to gain an understanding of the meteorological correlation between long-term weather observation stations and short-term met-mast measurements. The wind resource database for Jejudo, is to be provided as an add-on to Google $Earth^{TM}$, which is expected to be utilized as a guideline for the selection of an appropriate reference site for long-term correction in the next wind farm development project.