• 제목/요약/키워드: Mercury electrode

검색결과 98건 처리시간 0.039초

Adsorptive Behavior of Catechol Violet and Its Thorium Complex on Mercury Electrode in Aqueous Media

  • Rabia Mostafa K. M.
    • 전기화학회지
    • /
    • 제7권1호
    • /
    • pp.9-15
    • /
    • 2004
  • Cyclic voltammetry and chronocoulometry have been used for characterization of catechol violet (CV) at the hanging mercury drop electrode in acetic acid-sodium acetate buffer solution. At pH 2.94 a nearly symmetric cyclic voltammetric wave due to an irreversible weak adsorption of CV on mercury was obtained at concentration of $0.53{\mu}mol\;dm ^{-3}$. Under these conditions, CV adsorbes in a monolayer. Upon increasing the concentration, the symmetry of the wave decreases; it can be attributed to a mixed diffusion adsorption process. The amount of the adsorbed catechol violet on the HMDE expressed as surface concentration as well as the surface areaf occupied by one molecule$(\sigma)$ were calculated. It was found that the values obtained for f and o utilizing cyclic voltammetric and chrono-coulometry are almost identical. A 1:1 and 1:2 Th (IV)-CV complexes are formed on addition of thorium (IV) to catechol violet. These complexes are adsorbed and reduced on the HMDE at more negative potentials than the peak potential of free CV, Using the square-wave (SW) technique, the adsorptive cathodic stripping voltammetry, ACSV, of these complexes was studied. It was found that the SW-ACSV of Th(IV)-CV can be applied to the determination of thorium at the nanomole level. Optimum conditions and the analytical method of determination were presented and discussed.

Voltammetric Studies of Cu-Adriblastina Complex and its Effect on ssDNA-Adriblastina Interaction at In Situ Mercury Film Electrode

  • D.Abd El Hady;M.Ibrahim Abdel Hamid;M.Mahmoud Sellem;N.Abo E Maali
    • Archives of Pharmacal Research
    • /
    • 제27권11호
    • /
    • pp.1161-1167
    • /
    • 2004
  • Adriblastina, a cancerostatic anthracycline antibiotic, causes considerable oxidative damage to DNA molecules. The interaction of this compound with DNA was investigated using Osteryoung square wave stripping voltammetry (OSWSV) and cyclic voltammetry (CV) at an in situ mercury film electrode. It was found that the equilibrium constant of the bonded oxidized form of the drug was 63 times bigger more important than that of the bonded reduced form. Copper forms 1 metal: 2 drug stoichiometry complex which is highly stable compared to ssDNA-drug interaction and consequently inhibited the drug biochemical damaging effects. Copper complex offered sub-nanogram determination of adriblastina in aqueous and urine media.

Electrochemical Parameters with unusual Alternating Current Phase-Angles

  • Rashwan Farouk;Mohran Hossnia
    • 전기화학회지
    • /
    • 제7권2호
    • /
    • pp.80-82
    • /
    • 2004
  • The a.c. technique is employed to evaluate electrochemical characteristics of Naphthalie-1,4,5,8-tetracarboxylic acid bisanilide (NTB). The measurements were carried out in dry and pure propionitrle (PCN) and acetonitrile(CAN) at the hanging mercury drop electrode [HMDE). An A.C. phase sensitive detector using computer controlled lock-in amplifier was employed. Primary goal of this report, was to establish on a firm the rare behavior of the phase angle associated with a.c. polarograms of the compound. Although, not an initial goal of this study, the electron transfer rate parameters attending the electroreduction of the compound under investigation were determined. This because the results shed some light on the electrokinetics in aprotic solvent which until recently negligible data were available. Experimental Results and comparison of data obtained are reported. The good precision of the method makes it suitable for studying electrochemical data with unusual behavior at electrodes in non aqueous media.

Real-Time Voltammetric Assay of Lead Ion in Biological Cell Systems

  • Ly, Suw-Young
    • Toxicological Research
    • /
    • 제25권4호
    • /
    • pp.231-235
    • /
    • 2009
  • Trace lead detection for cyclic voltammetry (CV) and square-wave (SW) stripping voltammetry was performed using mercury immobilized onto a carbon nanotube electrode (HNPE). Using the characteristics of mercury and the catalytic carbon nanotube structure, a modified technique, the $0.45{\mu}g/l$ detection limit of lead ion was attained. The developed method can be applied to pond water, fish tissue, plant tissue, and in vivo direct assay.

Mercapto 화합물에 의한 은의 정량 (제1보) 2,5-Dimercapto-1,3,4-Thiadiazol에 의한 은의 전류 적정 (Determination of Silver with Mercaptans (I). Amperometric Titration of Silver with 2,5-Dimercapto-1,3,4-Thiadiazole)

  • 하영구;최규원
    • 대한화학회지
    • /
    • 제17권2호
    • /
    • pp.126-129
    • /
    • 1973
  • 회전백금전극을 지시전극으로하고 수은-요오드화수은(II)을 기준전극으로하여 암모니아수용액에서 2.5-dimercapto-1,3,4-thiadiazole에 의한 은의 전류적정법을 연구하였다. 암모니아수용액에서 EDTA를 은폐제로 사용하여 여러 가지 이온들의 존재 하에 미량의 은을 직접 적정할 수가 있었으며 백금과 금 이온만이 방해하였다. 이 방법으로 미량의 은을 상대 오차 ${\pm}3{\%}$이내 정량할 수 있다.

  • PDF

水銀滴下電極에서 一次反應에 對한 포라로그라프電流에 關한 硏究 (Studies on the Polarographic Kinetic Currents for the First Order Reactions at the Droping Mercury Electrode)

  • 김황암;태창희
    • 대한화학회지
    • /
    • 제6권1호
    • /
    • pp.14-18
    • /
    • 1962
  • Solution to the diffusion layer for the first order reaction at a droping mercury electrode (D.M.E.) is presented. Equations are derived for polarographic currents for the reactions at the D.M.E. A factor which is applicable to the D.M.E. is derived, when we use the equations of the polarographic currents for the reactions at a plane electrode(P.E.), and the rate constants of the backward reactions are negligibly small. Polarographic currents from a combination of diffusions and reactions are obtained at the D.M.E. with special approximation. Rate constant for the reaction of ferrous ion with hydrogen-peroxide is determined at the D.M.E.,using the data of Kolthoff and Perry. The agreement of the equation with the data of Kolthoff and Perry for the kinetic current of ferric ion in the presence of hydrogen-peroxide is good. Ratios of diffusion layer at the D.M.E. to the diffusion layer at the P.E. are discussed and show that, when the rate constants of the backward reactions for the first order reactions are larger than 1/0.05 sec-1. and drop-time about 3 sec., these ratioes are about one.

  • PDF

Propanediol-1,2-carbonate 용매에서 우라늄(VI)의 전기화학적 연구 (Electrochemical Study of Uranium(VI) in Propanediol-1,2-Carbonate)

  • 박종민;김영래
    • 대한화학회지
    • /
    • 제32권4호
    • /
    • pp.351-357
    • /
    • 1988
  • Propanediol-1,2-carbonate (PDC) 용매중에서 우라닐 화합물의 전기화학적 환원반응 메카니즘을 전압전류법으로 조사하여 봉우리 전위의 위치, 한계전류의 성질, 한계전류와 온도 및 농도의 관계, 전극반응의 가역성, 양성자 공여체인 페놀의 첨가에 대한 영향등을 기술하였다. 또 우라닐 화합물의 수용액에 PDC의 양을 점차 증가시킨 혼합용매에서의 전극반응도 조사하였다. 우라닐 화합물의 비가역적 전극반응에 관여하는 전이계수 및 속도상수등의 반응 속도론적 파라미터를 Koutecky의 이론에 따라 결정하였으며, ${\Delta}H,\;{\Delta}G\;및\;{\Delta}S$등에 열역할적 파라미터도 계산하였다.

  • PDF

Nafion-EDTA가 수식된 유리탄소전극을 이용한 수은(II)의 측정 (Determination of Mercury(II) Using Nafion-EDTA-Modified Glassy Carbon Electrodes)

  • 정근호;박찬주;박율희;이지영
    • 한국환경보건학회지
    • /
    • 제26권4호
    • /
    • pp.110-114
    • /
    • 2000
  • Determination of mercury(II) using Nafion-EDTA-modified glassy carbon electrodes is proposed. it is based on the chemical reactivity of an immobilized modifier, Nafion-EDTA. Differential pulse voltammetry is employed, and the oxidation of complexes, at +0.43V vs. Ag/AgCl, is observed. For a 5-min preconcentration period, a linear calibration curve is obtained for mercury(II) concentrations ranging from 1.0$\times$ 10$^{-8}$ to 1.0$\times$10$^{-6}$ M. Further, when an approximate amount of copper(II) is added to the test solution, We demonstrate that at a preconcentration time of 5 min the Nafion-EDTA-modified glassy carbon electrode has a dynamic range of 2 orders of magnitude(from 10$^{-10}$ to 10$^{-8}$ M) and the detection limit is as low as 0.5$\times$ 10$^{-10}$ M(0.01 ppb). This method is applied to the determination of mercury(II) in sea water(4.0$\times$10$^{-10}$ M, 0.08ppb). The result agrees satisfactorily with the value(below 0.1 ppb) measured by using ICP/MS.

  • PDF

무수은 면광원 램프용 Scanning Backlight 구동회로 (Scanning Backlight Driver for Mercury Free Flat Fluorescent Lamp)

  • 오은태;정용민;이경인;유호원;이준영
    • 전력전자학회논문지
    • /
    • 제14권1호
    • /
    • pp.8-14
    • /
    • 2009
  • 현재 사용하고 있는 LCD(Liquid Crystal Display) Backlight용 램프는 주로 CCFL(Cold Cathod Fluorescent Lamp)과 EEFL(External Electrode Fluorescent Lamp)이 사용되고 있다. 하지만 이 램프는 수은을 사용하여 RoHS(the Restriction of e use of certain Hazardous Substances in electrical and electronic equipment)규제가 점점 강화되면서 사용이 제한되고 있으며, 이에 따라 수은을 사용하지 않는 램프의 제작이 불가피해지고 있다. 또한 LCD TV는 CRT와 PDP와는 다른 LCD만의 Hold-type 특성과 LC(Liquid Crystal)의 응답속도로 인하여 Motion Blur현상이 나타나는 단점이 있다. 본 논문에서는 RoHS 규제를 만족시키는 무수은 면광원 램프를 구동하기 위한 인버터를 제안한다. 제안한 인버터는 포워드 방식을 사용하여 반도체 소자 및 자기 소자의 수를 줄여서 구동회로가 간단하다. 또한 면광원 램프를 세로방향으로 6블록으로 나누어 스캔구동을 하여 Motion Blur현상을 저감 시켰다. 끝으로 실험을 통하여 제안한 인버터의 유용성을 입증하였다.

Hgl2의 누설전류 저감을 위한 다층구조 제작 및 특성 평가 (The Multi-layer Fabrication and Characteristic Performance for Dark Current Reduction of Mercury Iodide)

  • 김경진;박지군;강상식;차병열;조성호;김진영;문치웅;남상희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2005년도 하계학술대회 논문집 Vol.6
    • /
    • pp.388-389
    • /
    • 2005
  • In this paper, the electric properties of mercury Iodide multi-layer samples has been investigated. We measured and analyzed their performance parameters such as the X-ray sensitivity and dark-current for a mercury Iodide multi-layer X-ray detector with a dielectric layer. The digital X-ray image detector can be constructed by integrating photoconduction multi-layer that dielectric layer has characteristics of low dark-current, high X-ray sensitivity. However this process has found to have complexity on the performance of the sample. We have investigate dielectric layer that it substitute dielectric layer for HgO(Mercury Oxide). We have employed two approaches for producing the mercury Iodide sample : 1) Physical Vapor Deposition(PVD) and 2) Particle-In-Binder(PIB). In this paper fabricated by PIB Method with thicknesses ranging from approximately 180um to 240um and we could produce high-quality samples for each technique particular application. As results, the dielectric materials such as HgO between the dielectric layer and the top electrode may reduce the dark-current of the samples. Mercury Iodide multi-layer having HgO has characteristics of low dark-current, high X-ray sensitivity and simple processing. So we can acquired a enhanced signal to noise ratio. In this paper offer the method can reduce the dark-current in the X-ray detector.

  • PDF