• 제목/요약/키워드: Membrane sensor

검색결과 356건 처리시간 0.027초

Highly Sensitive Multichannel Interdigitated Capacitor Based Bitterness Sensor

  • Khan, Md. Rajibur Rahaman;Kang, Shin-Won
    • 센서학회지
    • /
    • 제27권2호
    • /
    • pp.69-75
    • /
    • 2018
  • In this study, we propose a multichannel interdigitated capacitor (IDC) sensor for detecting the bitterness of coffee. The operating principle of the device is based on the variation in capacitance of a sensing membrane in contact with a bitter solution. Four solvatochromic dyes, namely, Nile red, Reichardt's dye, auramine-O, and rhodamine-B, were mixed with polyvinylchloride (PVC) and N,N-dimethylacetamide (DMAC), to create four different types of bitter-sensitive solutions. These solutions were then individually inserted into four interdigitated electrodes (IDEs) using a spin coater, to prepare four distinct IDC sensors. The sensors are capable of detecting bitterness-inducing chemical compounds in any solution, at concentrations of approximately $1{\mu}M$ to 1 M. The sensitivity of the IDC bitterness sensor containing the Reichardt's dye sensing-membrane was approximately 1.58 nF/decade. The multichannel sensor has a response time of approximately 6 s, and an approximate recovery time of 5 s. The proposed sensor offers a stable sensing response and linear sensing performance over a wide measurement range, with a correlation coefficient ($R^2$) of approximately 0.972.

저잡음화 계측회로에 의한 다음극형 용존산소센서의 산소투과특성 (Oxygen Permeability Characteristics of the Multi-Cathode Type Dissolved Oxygen Sensor Using the Low Noise Measuring Circuit)

  • 이동희;김태진;김영환;성영권
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 추계학술대회 논문집 학회본부 C
    • /
    • pp.764-766
    • /
    • 1998
  • An evaluation method for oxygen permeable characteristics of the membrane covering to each cathode of multiple cathode - single anode type dissolved oxygen sensor, which has high reproducibility and is capable of measuring multiple components in solutions. For this purpose, a measuring circuit for the multiple cathode type DO sensor was designed to lower the noise signal by adapting a digital LPF to readout the sensor output accurately. Digital LPF is designed by setting up the transfer function to set the cutoff frequency to 10Hz, and the transfer function is programmed by C language, and then the filtering characteristics are evaluated with the simulation and experiments. Using this LPF added measuring circuit for the multiple cathode type DO sensor, we have obtained the calibration factor for each cathode to calibrate the variation of the output signals. The calibration factor was obtained by measuring the sensor output signal followed by oxygen partial pressure, using the same oxygen permeable membrane at each cathode of the multiple cathode type DO sensor.

  • PDF

Potentiometric Sensor for the Determination of Dibucaine in Pharmaceutical Preparations and Electrochemical Study of the Drug with BSA

  • Ensafi, Ali A.;Allafchian, A.R.
    • Bulletin of the Korean Chemical Society
    • /
    • 제32권8호
    • /
    • pp.2722-2726
    • /
    • 2011
  • Plasticized poly(vinyl chloride), PVCs, with different membrane compositions tested for use in the construction of an ion-selective sensor for the determination dibucaine. A prepared membrane with dioctyl phthalate-PVC and ion-pair of N-(1-naphthyl)ethylenediamine dihydrochloride-tetraphenyl borate had a good potential to acts as a potentiometric sensor for the analysis of dibucaine. A linear relationship was obtained between potential and logC varying between $1.0{\times}10^{-6}$ and $1.0{\times}10^{-2}$ M dibucaine with a good repeatability and reproducibility. The sensor was applied for the determination of the drug in pharmaceuticals and biological fluids such as plasma and urine samples with satisfactory results. The drug electrode has also been used to study the interaction of bovine serum albumin (BSA) with dibucaine. The saturated quantities of dibucaine binding were 13.04, 5.30 and 9.70 mol/mol in 0.01, 0.02 and 0.1% of protein, respectively.

Infrared Focal Plane Array 용 MEMS 구조체 개발 (Development of a MEMS Structure for an Infrared Focal Plane Array)

  • 조성목;양우석;류호준;전상훈;유병곤;최창억
    • 전기학회논문지
    • /
    • 제56권8호
    • /
    • pp.1461-1465
    • /
    • 2007
  • A micromachined sensor part for an infrared focal plane array has been designed and fabricated. Amorphous silicon was adapted as a sensing material, and silicon nitride was used as a membrane material. To get a good efficiency of infrared absorption, the sensor was made as a ${\lambda}/4$ cavity structure. All the processes were done in $0.5\;{\mu}m$ iMEMS fab. in the Electronics and Telecommunication Research Institute (ETRI). The processed MEMS sensor structure had a small membrane deflection less than $0.3\;{\mu}m$. This excellent deflection property can be attributed to the rigorous balancing of the stresses of individual layers. The efficiency of infrared absorption was more than 75% in the wavelength range $8\;-\;14\;{\mu}m$.

빔 혹은 멤버레인 구조를 가지는 써모파일 센서의 다목적 최적설계 (The Multi-objective Optimal Design of Thermopile Sensor Having Beam or Membrane Structure)

  • 이준배;김태윤
    • 센서학회지
    • /
    • 제6권1호
    • /
    • pp.6-15
    • /
    • 1997
  • 이 논문은 빔의 구조를 갖거나 멤브레인의 구조를 갖는 써모파일 센서의 다목적 최적설계에 관한 연구이다. 연구대상의 써모파일 센서는 $Si_{3}N_{4}/SiO_{2}$ 박막위에 알루미늄과 다결정 실리콘을 사용하여 열전쌍을 형성하고, 박막중심부에 $RuO_{2}$를 사용하여 적외선 흡수부를 만들어 중심부와 실리콘림부 사이의 온도차이에 따른 Seebeck 효과에 의한 유기전압을 감지하는 센서를 대상으로 하였다. 최적설계의 목적함수는 센서의 감도, 검출능 (detectivity) 및 열시정수를 대상으로 하였다. 패키지를 고려하여 모델링을 하였으며, 기존의 식의 고찰에 의한 단순 설계방법이 아닌 수학적 계획법을 사용한 다목적 최적화 방법을 이용하여 최적해를 구하였다. 최종적인 최적설계 수식화에는 퍼지계획법에서 사용되는 소속함수를 정의하여 설계자가 우선적으로 신뢰할 수 있는 해를 구 할 수 있도록 하였다. 또한, 제한조건으로서 주위 온도변화에 따른 센서의 출력전압변화를 포함시켜 실제 사용되는 환경을 고려하였다.

  • PDF

고분자막 pH 센서 제작 및 특성 (Preparation and characterization of polymeric membrane pH Sensors)

  • 조동회;정성숙;정구춘;이경호;박면용;김병수
    • 센서학회지
    • /
    • 제5권4호
    • /
    • pp.35-40
    • /
    • 1996
  • 수소이온운반체로 HDBA(hexyldibenzylamine)나 HDPA(hexyldiphenylamine)을 이용하여 고분자막 pH 센서를 제작하였고, 온도 및 막의 두께 변화에 대한 전기화학적 특성을 연구하였다. HDPA를 이용한 센서는 수소이온에 대하여 선택적으로 감응하지 않았으며, HDBA를 이용한 센서는 pH 2 - pH 10 범위에서 수소이온에 대하여 선형적이고, 응답시간도 30 - 50초로 매우 빠르며, Nernstian 기울기는 53.6mV/pH을 나타내었다. pH 센서는 유리전극과 비교하여 알칼리금속과 알칼리토 금속이온에 대하여 방해를 적게 받았고, 재현성 및 안정성에 대한 편차는 2 - 4mV(${\pm}0.1mV$)로 우수하게 나타내었다.

  • PDF

세라믹소재를 이용한 해수압센서 제작 및 전기적 특성 연구 (A Study on the Fabrication and Electrical Characteristics of Hydraulic Pressure Sensors by Using Ceramics Materials)

  • 박성현;김은섭;정정균
    • 한국전기전자재료학회논문지
    • /
    • 제28권6호
    • /
    • pp.384-389
    • /
    • 2015
  • In this paper, we fabricated ceramic body and sapphire wafer in order to develop a hydraulic pressure sensor with high sensitivity and high temperature stability. The sapphire wafer was adopted with a membrane of capacitance ceramic pressure sensor. The capacitance value of the sensor for the finite element analysis(FEM) showed a linear pressure characteristics. Membrane was processed with a diameter of 32.4 mm and a thickness of 1 mm by using alumina powders. Ceramic body was processed with a diameter 32.4 mm and a thickness 5 mm. The capacitance pressure sensor was made with high heat treatment of the ceramic body and the sapphire wafer. Initially capacitance of the pressure sensor was 50 pF and a capacitance of 110 pF was measured from 5 bar pressure. Output voltage of 5 V was appeared at 5 bar pressure.

4차 암모늄 염을 포함하는 폴리메타크릴레이트 습도센서 (Humidity Sensor of Polymethacrylate with 4th Ammonium Salt)

  • 홍채환;김세훈;남병욱
    • 폴리머
    • /
    • 제31권3호
    • /
    • pp.255-262
    • /
    • 2007
  • 고분자 습도센서 막으로 사용하기 위한 두 가지 타입의 공중합체를 라디칼 중합방식에 의하여 제조하였다. 각각 공중합체는 세 가지의 단량체를 포함하여 제조하였는데, 각 단량체들은 습도 저항성, 막 안정성, 유연성, 임피던스 및 전극 부착력을 증대시키는 효과를 가지도록 하였다. 염 형태의 MDBAB는 제조된 습도 막의 임피던스를 감소시키는 효과를 보였으며 아민과 반응하여 가교 구조를 생성하였다. DAEMA, 4-VP, 및 2-EHA를 사용하여 습도막 제조를 위하여 몇 가지 조성물을 제조하였다. 특정 조성 조건에서 성능 및 장기 내구성 측면에서 우수한 결과를 얻을 수 있었다.

실리콘 빔이 실리콘 고무 멤브레인에 삽입된 빗살형 차압센서의 설계 및 제조 (Design and fabrication of a comb-type differential pressure sensor with silicon beams embedded in a silicone rubber membrane)

  • 박정용;공성수;서창택;신장규;고광락;이종현
    • 센서학회지
    • /
    • 제9권6호
    • /
    • pp.424-429
    • /
    • 2000
  • 실리콘 고무 멤브레인(membrane)에 실리콘 빔(beam)들이 삽입된 형태의 저차압센서를 개발하였다. 제작된 저차압센서는 실리콘 고무(silicone rubber)를 멤브레인으로 사용함으로써 열악한 환경에서도 다양한 응용분야에 적용 가능하도록 하였다. 실리론 고무 멤브레인을 사용한 압저항형 저차압센서는 선택적으로 도핑(doping)된 (100) n/n+/n 웨이퍼 상에 다공질 마이크로머시넝(micro-machining) 기술을 이용하여 제작되었다. 제조된 센서의 감도(sensitivity)는 $0.66{\mu}V/mmHg$이고, 0.1% 이하의 비선형성(non-linearity)을 보였다.

  • PDF