• Title/Summary/Keyword: Membrane exposure

Search Result 312, Processing Time 0.027 seconds

The Comparative Study On Scanning Electron Microscopic Findings Of Retrived ePTFE Membrane With Clinical Conditions (제거된 ePTFE 막의 주사전자현미경적 소견과 치주임상상태의 비교연구)

  • Park, Jeong-Min;Choi, Byung-Son;Lee, Seok-Cho;Kim, Hyung-Seop
    • Journal of Periodontal and Implant Science
    • /
    • v.26 no.1
    • /
    • pp.133-142
    • /
    • 1996
  • Ten intrabony defects in 10 patients were treated by flap surgery including root surface debridement and placement of an expanded polytetrafluoroethylene(ePTFE) membrane. The membranes were removed after 4-6 weeks. This study was performed to examine the retrived ePTFE membrane by scanning electron microscopy(SEM) for bacterial contamination and adherent connective tissue elements, and to compare it with clinical conditions. The cervical portion of the membrane, which in most cases had become partially exposed to the oral cavity, had a bacterial deposit. Small bacterial colonies and a scatter of single cells in some instances extended into the apical portion of the membrane. Fibroblast-like cells, erythrocytes and fibrous structures were seen in the apical portion of the membrane. Outer surface of membrane tends to more bacterial contamination than inner surface(p<0.01), and upper portions more than lower portions(P<0.01). Comparison of ultrastructural findings and clinical conditions revealed that extent of bacterial contamination of the membrane correlated with gingival inflammation and extent of membrane exposure, but it was not significant statistically. The results suggested that gingival inflammation and membrane exposure affect periodontal regeneration by the use of ePTFE membrane.

  • PDF

Effects of exposure intensity of sodium hydroxide on PVDF membrane performance (수산화나트륨의 노출 강도가 PVDF 분리막 성능에 미치는 영향)

  • Lee, Yong-Soo;Kang, Ha-Young;Kim, Woo-Ha;Lee, Chang-Kyu;Kim, Jong-Oh
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.32 no.5
    • /
    • pp.453-460
    • /
    • 2018
  • The impact of sodium hydroxide, which is one of chemicals of clean in place (CIP) for removing membrane fouling, on the PVDF membrane is reviewed with respect to physical/chemical structural change, the permeability affected therefrom. Based on the cleaning concentration applied in membrane water treatment facilities, 10% of accumulated defluorination was confirmed up to 166g.hr/L which reflects the exposure time. However, membrane resistance was confirmed to be reduced by about 10%. Through FT-IR and EDS analysis, reduction of F and change of are confirmed as factors that affect the permeability of membrane. Membrane resistance, which affects permeability, is affected by loss of additives for hydrophilicity, rather than defluorination of PVDF material. Therefore, in order to check membrane degradation degree, an accelerated test by NaOH was carried out, loss of additives was confirmed, and then PVDF inherent characteristic was observed.

Permanent Sprayed Concrete Tunnel Linings Waterproofed with Bonded Membranes. A Review of the Current State-of-the-art for Hard Rock Conditions

  • Holter, K.G.
    • Magazine of korean Tunnelling and Underground Space Association
    • /
    • v.21 no.2
    • /
    • pp.103-116
    • /
    • 2019
  • Permanent sprayed concrete tunnel linings waterproofed with bonded membranes have been used at a number of important traffic projects over the last decade. Research has been carried out in several teams in order to increase the understanding of the function, properties and behavior of such linings under different loading and boundary conditions. The basic layout of this lining gives fundamental different system properties compared to the traditional lining systems. The main differences pertain to the groundwater exposure and the resulting hydraulic loading, the response of the concrete and membrane materials to this loading, as well as the geomechanically induced loading of the lining structure. The current understanding of the function and properties of such lining structures is presented in the paper based on review of recent research carried out in Norway, as well as field observations and monitoring carried over a several years. The influence of the water exposure on the final condition of the concrete and membrane materials has proven to be of vital importance for proper material testing and acceptance, assessments of the mechanical contribution of the bonded membrane, as well as assessments of the longterm durability of such linings. Obtaining realistic material parameters for the concrete and membrane materials subject to the boundary conditions posed by the groundwater exposure in an undrained structure is emphasized. Finally, some recent results from currently ongoing research on such linings, particularly the hydraulic response of the rock mass and the long term behavior of the concrete and membrane materials are presented.

A Clinical Comparision of Nonresorbable and Resorbable Membrane in the Treatment of Human Class II Furcation Defects (II급 치근이개부병변에서 비흡수성막과 흡수성막을 이용한 조직유도재생술의 임상적 비교)

  • Jang, Chae-Yun;Lee, Jae-Mok;Suh, Jo-Young
    • Journal of Periodontal and Implant Science
    • /
    • v.31 no.4
    • /
    • pp.689-711
    • /
    • 2001
  • The purpose of this study was to compare clinical results of guided tissue regeneration(GTR) using either a nonresorbable ePTFE membrane or a resorbable membrane made from a synthetic copolymer of glycolide and lactide(PLGA) in the treatment of human class Ⅱ furcation defects. The ePTEE membranes were applied to 16 patients with maxillary molar buccal class Ⅱ furcation defects as Group I, PLGA membranes were applied to 15 patients with maxillary molar buccal class Ⅱ furcation defects as Group Ⅱ, ePTFE membranes were applied to 20 patients with mandibular molar buccal class Ⅱ furcation defects as Group Ⅲ and PLGA membranes were applied to 20 patients with mandibular molar buccal class Ⅱ furcation defects as Group Ⅳ and bone graft materials(DFDBA) were applied in all groups. Probing depth, gingival recession, clinical attachment level, tooth mobility and sulcus bleeding index(SBI) were measured at baseline, 3, 6 and 12months postoperatively. In addition, membrane exposure levels were measured at surgery, 1, 2 and 6weeks postoperatively and postoperative complications were evaluated. The results were as follows: In all groups, there were statistically significant differences in probing depth reduction, gain of clinical attachment and mobility reduction at values of 3, 6 and 12months postoperatively compared to values of baseline, whereas no significant differences in SBI except Group I and gingival recession(p<0.05). Membrane exposure levels were increased at 1, 2 and 6weeks postopratively compared to value of baseline in Group I(p<0.05). There were no statistically significant differences between ePTFE and PLGA membrane in probing depth, clinical attachment level and SBI. There were minimal gingival recession and membrane exposure in Group Ⅳ and pain and swelling were the most common postoperative complications in Group Ⅱ, Ⅲ(p<0.05). In conclusion, this study showed that both nonresorbable membrane and resorbable membrane were effective similarly in the treatment of class Ⅱ furcation defects, without statistical differences in clinical measurements.

  • PDF

A novel approach to bind graphene oxide to polyamide for making high performance Reverse Osmosis membrane

  • Raval, Hiren D.;Das, Ravi Kiran
    • Membrane and Water Treatment
    • /
    • v.8 no.6
    • /
    • pp.613-623
    • /
    • 2017
  • We report the novel thin film composite RO membrane modified by graphene oxide. The thin film composite RO membrane was exposed to 2000 mg/l sodium hypochloride; thereafter it was subjected to different graphene oxide concentration ranging from 50 mg/l to 1000 mg/l in water. The resultant membrane was crosslinked with 5000 mg/l N-hydroxysuccinimide. The performance of different membranes were analysed by solute rejection and water-flux measurement. It was found that 100 mg/l graphene oxide exposure followed by 5000 mg/l N-hydroxysuccinimide treatment resulted in the membrane with the highest solute rejection of 97.78% and water-flux of 4.64 Liter per sqm per hour per bar g. The membranes were characterized by contact angle for hydrophilicity, scanning electron micrographs for surface morphology, energy dispersive X-Ray for chemical composition of the surface, Atomic force microscope for surface roughness, ATR-FTIR for chemical structure identification. It was found that the graphene oxide modified membrane increases the salt rejection performance after exposure to high-fouling water containing albumin. Highly hydrophilic, antifouling surface formation with the nanomaterial led to the improved membrane performance. Moreover, the protocol of incorporating nanomaterial by this post-treatment is simple and can be applied to any RO membrane after it is manufactured.

The Histologic Findings and the Expression of Laminin in the Mucosa of the Rat Trachea During (백서 기관 점막의$SO_2$ 노출 후 회복과정의 조직학적 관찰 및 laminin의 발현에 관한 연구)

  • Lee, Hyung-Seok;Tae, Kyung;Cho, Seok-Hyun;Han, Jang-Hee;Jeong, Jin-Suck
    • Korean Journal of Bronchoesophagology
    • /
    • v.8 no.1
    • /
    • pp.29-34
    • /
    • 2002
  • Background and Objectives : Sulfur dioxide gas is one of the major airborne Pollutants noxious to human in industrialized countries. The most vulnerable areas in the human respiratory system were the trachea and main bronchi and a gradient of decreasing damage was observed in the peripheral tracheobronchial tree. Induced functional alteration was increased mucosal permeability, and morphological changes were epithelial sloughing, intracellular edema, mitochondrial swelling, widened intercellular spaces, and ciliary cytoplamic extrusions. The laminins are a family of extracellular matrix glycoproteins localized in the basement membrane. Their primary role is cell-matrix attachment, but many additional biologic activities, including Promoting cell growth and migration, tumor growth and metastasis, wound repair, and graft survival, have been demonstrated. Materials and Methods : Histologic changes and expression of laminin in tracheal mucosa sacrificed at 1 day, 2 day, 3 day, 1 week, 2 weeks, and 3 weeks after continued SO2 exposure of 250 ppm for 30 minutes a day(to 7week) were studied in rats. In this study, mild immune reaction for laminin was noted at the apical cytoplasm of epithelial cells and basement membrane one day after a 7 week $SO_2$ exposure. The cilia and nucleoi of epithelial cells were normal and no immune reaction was noted in Goblet cells. The lamina propria of the tracheal tissue was infiltrated by monocytes and lymphocytes. Results : At 24 hours after exposure, all tracheal cells except Goblet cells revealed a mild immune reaction for laminin. No immune reactions were noted in the basement membrane. At 72 hours after exposure, mild or moderate immune reactions for laminin was seen in the tracheal cell cytoplasm. Irregular faint immune reaction for laminin was noted in the basement membrane. At 1 week after exposure, strong immune reaction for laminin was detected over all tracheal cells, and the basement membrane was seen clearly. At 2~3 weeks after exposure, strong immune reaction for laminin was seen in all tracheal epithelial cells except Goblet cells and a mild immune reaction was partly revealed in the basement membrane. Conclusion : Our study suggests that 502 produces histologic damage on the tracheal mucosa. Longer duration after exposure of $SO_2$ makes more progressive healing on the tracheal mucosa and increased immunoreactivity for laminin.

  • PDF

Analysis of fusogenic activity of autographa californica nuclear polyhedrosis virus (Ac NPV) gp64 envelope glycoprotein

  • Kim, Hee-Jin;Yang, Jai-Myung
    • Journal of Microbiology
    • /
    • v.34 no.1
    • /
    • pp.7-14
    • /
    • 1996
  • Teh baculovirus gp64 glycoprotein is a major component of the envelope of budded virus (BV) and has been shown that it plays an essential role in the infection process, especially virus-cell membrane fusion. We have cloned Autographa californica Nuclear Polyhedrosis Virus (AcNPV) gp64 protein were examined for membrane fusion activity by using a synchtium formation assay under various conditions. The optimal conditions required for inducing membrane fusion are 1) form pH 4.0 to 4.8 2) 15 min exposure of cells to acidic pH 3) at least 1 .mu.g of gp64 cloned plasmid DNA per 3 * 10$^{6}$ cells 4) and an exposure of cells to acidic pH at 72 h post-transfection. In order to investigate the role of hydrophobicity of the gp64 glycoprotein for the membrane fusion, the two leucine residues (amino acid position at 229 and 230) within hydrophobic region I were substituted to alanine by PCR-derived site-directed mutagenisis and the membrane fusion activity of the mutant was anlaysed. The gp64 glycoprotein carrying double alamine substitution mutation showed no significant difference in fusion activity. This result suggested that minor changes in hydrophobicity at the amino acid position 229 and 230 does not affect the acid-induced membrane fusion activity of the gp64 glycoprotein.

  • PDF

The influence of membrane exposure on post-extraction dimensional change following ridge preservation technique (차폐막 노출이 발치 후 치조제 보존술의 결과에 미치는 영향에 관한 임상적 연구)

  • Nam, Hyun-Wook;Park, Yoon-Jeong;Koo, Ki-Tae;Kim, Tae-Il;Seol, Yang-Jo;Lee, Yong-Moo;Gu, Young;Rhyu, In-Chul;Chung, Chong-Pyoung
    • Journal of Periodontal and Implant Science
    • /
    • v.39 no.3
    • /
    • pp.367-373
    • /
    • 2009
  • Purpose: Following tooth extraction caused by severe periodontitis, alveolar ridge dimension lose their original volume. To reduce the alveolar ridge dimension, the ridge preservation technique has been introduced and tested in many clinical studies with membrane alone or membrane plus graft, achieving reduced ridge loss compared to extraction only. The aim of the present clinical study was to compare the post-extraction dimensional changes in the membrane exposure group to non-exposure group during healing period following ridge preservation technique. Methods: Ridge preservation was performed in 44 extraction sites. After extraction, deproteinized bovine bone mineral coated with synthetic oligopeptide (Ossgen-$X15^{(R)}$) or deproteinized bovine bone mineral (Bio-$Oss^{(R)}$) was implanted into the socket. A collagen membrane (Bio-$Gide^{(R)}$) was trimmed to cover the socket completely and applied to the entrance of the socket. Four clinical parameters were compared between baseline and 6 months. Results: During healing period, membrane exposure was observed at 19 sites. At the re-entry, hard newly formed tissue were observed at the ridge preservation site. The grafted socket sites were well preserved in their volume dimension. In both groups, horizontal ridge width was reduced and vertical height was increased. There were not statistically significant differences in horizontal (-1.32 mm vs -1.00 mm) and vertical ridge change (2.24 mm vs 2.37 mm at buccal crest, 1.36 mm vs. 1.53 mm at lingual crest) between two groups. Conclusions: The ridge preservation approach after tooth extraction effectively prevented resorption of hard tissue ridge in spite of membrane exposure during healing period.

Effects of Mitochondrial Reactive Oxygen Species on Neuronal Excitability in Rat Spinal Substantia Gelatinosa Neurons

  • Lee, Hae-In;Park, A-Reum;Chun, Sang-Woo
    • International Journal of Oral Biology
    • /
    • v.37 no.1
    • /
    • pp.17-23
    • /
    • 2012
  • Recent studies indicate that reactive oxygen species (ROS) are critically involved in persistent pain primarily through spinal mechanisms, and that mitochondria are the main source of ROS in the spinal dorsal horn. To investigate whether mitochondrial ROS can induce changes in membrane excitability on spinal substantia gelatonosa (SG) neurons, we examined the effects of mitochondrial electron transport complex (ETC) substrates and inhibitors on the membrane potential of SG neurons in spinal slices. Application of ETC inhibitors, rotenone or antimycin A, resulted in a slowly developing and slight membrane depolarization in SG neurons. Also, application of both malate, a complex I substrate, and succinate, a complex II substrate, caused reversible membrane depolarization and enhanced firing activity. Changes in membrane potential after malate exposure were more prominent than succinate exposure. When slices were pretreated with ROS scavengers such as phenyl-N-tert-buthylnitrone (PBN), catalase and 4- hydroxy-2,2,6,6-tetramethylpiperidine-1-oxyl (TEMPOL), malate-induced depolarization was significantly decreased. Intracellular calcium above $100{\mu}M$ increased malateinduced depolarization, witch was suppressed by cyclosporin A, a mitochondrial permeability transition (MPT) inhibitor. These results suggest that enhanced production of spinal mitochondrial ROS can induce nociception through central sensitization.

VISUALIZATION OF THE INTERNAL WATER DISTRIBUTION AT PEMFC USING NEUTRON IMAGING TECHNOLOGY: FEASIBILITY TEST AT HANARO

  • Kim Tae-Joo;Jung Yong-Mi;Kim Moo-Hwan;Sim Cheul-Muu;Lee Seung-Wook;Jeon Jin-Soo
    • Nuclear Engineering and Technology
    • /
    • v.38 no.5
    • /
    • pp.449-454
    • /
    • 2006
  • Neutron imaging technique was used to investigate the water distribution and movement in Polymer Electrolyte Membrane Fuel Cell (PEMFC) at HANARO, KAERI. The Feasibility tests were performed in the first and second exposure rooms at the neutron radiography facility (NRF) at HANARO in order to check the ability of each exposure room, respectively. The feasibility test apparatus was composed of water and pressurized air before making up the actual test apparatus. Due to the low neutron intensity in the second exposure room, the exposure time was too long to investigate the transient phenomena of PEMFC. Although the exposure time was improved to 0.1 sec in the first exposure room, it was difficult to discriminate detail water movement at the channel due to the high noise level. Therefore, the experimental setup must be optimized according to the test conditions. Water discharge characteristics were investigated under different flow field geometries by using feasibility test apparatus and the neutron imaging technique. The water discharge characteristics of a 3-parallel serpentine are superior to those of a 1-parallel serpentine, but water at Membrane Electrode Assembly (MEA) was not removed, regardless of the flow field type.