• Title/Summary/Keyword: Medium temperature heat source

Search Result 51, Processing Time 0.024 seconds

Effects of Solution Treatment Temperatures on Microstructure and Mechanical Properties of TIG-MIG Hybrid Arc Additive Manufactured 5356 Aluminum Alloy

  • Zuo, Wei;Ma, Le;Lu, Yu;Li, Shu-yong;Ji, Zhiqiang;Ding, Min
    • Metals and materials international
    • /
    • v.24 no.6
    • /
    • pp.1346-1358
    • /
    • 2018
  • A novel additive manufacturing method with TIG-MIG hybrid heat source was applied for fabricating 5356 aluminum alloy component. In this paper the microstructure evolution, mechanical properties and fracture morphologies of both as-deposited and heat-treated component were investigated, and how these were affected by different heat-treated temperature. The as-deposited microstructure showed dominant equiaxed grains with second phase, and the size of them is coarse in the bottom region, medium in the middle region and fine in the top region owing to different thermal cycling conditions. Compared with as-deposited microstructure, the size of grain becomes large and second phases gradually dissolve in the matrix as heat-treated temperature increase. Different microstructures determine the mechanical properties of component. Results show that average ultimate tensile strength enhances from 226 to 270 MPa and average microhardness increases from 64.2 to 75.3 HV0.1 but ductility decreases from 33 to 6.5% with heat-treated temperature increasing. For all components, the tensile properties are almost the same in the vertical direction (Z) and horizontal direction (Y) due to equiaxed grains, which exhibits isotropy, and the mechanisms of these are analyzed in detailed. In general, the results demonstrate that hybrid arc heat source has the potential to fabricate aluminum alloy component.

Concentrating Solar Collector for Drying Process (건조가공용(乾燥加工用) 태양열(太陽熱) 집열장치(集熱裝置)에 관(關)한 연구(硏究))

  • Lee, Byung-Hyuk
    • Solar Energy
    • /
    • v.6 no.1
    • /
    • pp.24-30
    • /
    • 1986
  • A concentrating solar collector of parabolic-cylindrical type is designed and constructed to provide a heat source of higher temperature for drying processes. Usually collectors of concentrating type require such peripheral auxiliary units as solar tracking system, heat medium circulation pump and temperature controller. However in this study, for simplification's sake in the maintenance of a collector system, it is intended to design a concentrating collector system which does not furnish these auxiliary units by adapting natural circulation system instead of foced circulation and by adjusting collector system to solar altitude manually and periodically. And based on the experimental data, a conceptual design for a heat sources of 50KWt thermal output is presented and discussed.

  • PDF

Application of Combustion in Porous Inert Medium to Thermophotovoltaic Generation of Electricity and Excess Enthalpy Combustion Similarity to both Single and Multi-channels (다공체 내 연소의 열광전 발전에의 적용과 단일, 다중채널 및 다공체 내 초과 엔탈피 연소의 상사성)

  • Lee, Dae Keun
    • 한국연소학회:학술대회논문집
    • /
    • 2012.11a
    • /
    • pp.171-174
    • /
    • 2012
  • Thermophotovoltaics is the direct energy conversion technology from thermal to electric (voltaic) energy via photon radiation, without any thermodynamic cycle. It is, in general, accomplished by immersing solid body in high temperature heat source (e.g. combustion field), in order to achieve high intensity irradiation, and by receiving the radiation thereof on photovoltaic cells. In this paper, advantages of combustion in porous inert medium in applying to the thermophotovoltaics are discussed in a view of its excess enthalpy features. In addition, the similarities of flame behaviors in porous inert medium to both in single and multi-channels are described.

  • PDF

Three-dimensional Equivalent Transient Ground Heat Exchanger Thermal Analysis Model by Considering Heating and Cooling Operations in Buildings (건물의 냉난방 운전을 고려한 3차원 동적 지중 열교환기 열해석 모델)

  • Baek, Seung Hyo
    • Land and Housing Review
    • /
    • v.9 no.4
    • /
    • pp.25-32
    • /
    • 2018
  • Application of geothermal energy in buildings has been gaining popularity as it provides the benefits of both heating and cooling a building. Among the various types of geothermal energy systems, ground-coupled heat pump system is the most commonly applied one in South Korea. A ground heat exchanger plays an important role as a heat source in winter and a heat sink in summer. For the stable operation of a ground-coupled heat pump system, a ground heat exchanger should be sized so that it provides sufficient heating and cooling energy. Heating and cooling energies generated in ground heat exchangers mainly depend on the temperature difference between the heating medium in ground heat exchangers and the surrounding ground. In addition, the performance of ground heat exchangers influences the change in ground temperature. Therefore, it is necessary to consider this interrelation between the change in the ground temperature and the performance of ground heat exchanger for an accurate estimation of its performance. However, previous thermal analysis models for ground heat exchangers are not competent enough to allow a complete understanding of this interrelation. Therefore, this study proposes a three-dimensional equivalent, transient ground heat exchanger analysis model. First, a previous thermal analysis model for ground heat exchangers, including an analytical model, a g-function, and a numerical model are analyzed. Next, to overcome the limitations of the previous models, a three-dimensional equivalent, transient ground heat exchanger model is proposed. Finally, this study validated the proposed model with the measurement data of the thermal response test, sandbox test, and TRNSYS DST model. All validation results showed a good agreement. These findings helped us to investigate the thermal performance of ground heat exchangers more accurately than the analytical models, and faster than the numerical models. Furthermore, the proposed model contributes to the design of ground heat exchangers by considering the different operation conditions of buildings.

Novel Method for Polystyrene Reactions at Low Temperature

  • Katsuhiko Saido;Hiroyuki Taguchi;Yoichi Kodera;Yumiko Ishihara;Ryu, In-Jae;Chung, Seon-yong
    • Macromolecular Research
    • /
    • v.11 no.2
    • /
    • pp.87-91
    • /
    • 2003
  • Thermal decomposition reactions of polystyrene using a new heating medium were carried out by a batch system at 190-280 $^{\circ}C$ to clarify the manner in which decomposition is initiated. Polystyrene obtained from a commercial source and low molecular weight compounds obtained from the thermal decomposition were analyzed by GC, GPC, IR, $^{13}$ C-NMR and GC-MS. The main chain underwent virtually no change by heat application. Polystyrene underwent decomposition below its molding temperature and the major decomposition products were 2,4,6-triphenyl-1-hexene (trimer), 2,4-diphenyl-1-butene(dimer) and styrene (monomer). Ethylbenzene, propylbenzene, naphthalene, benzaldehyde, biphenyl and 1,3-diphenylpropane were detected as minor products. This paper presents a new method for examining the decomposition of polystyrene at low temperature into volatile low molecular weight compounds.

Comparison of Efficiency for Voltage Source and Current Source Based Converters in 5MW PMSG Wind Turbine Systems (전압형 및 전류형 컨버터를 적용한 5MW PMSG 풍력발전시스템의 효율 비교)

  • Kang, Tahyun;Kang, Taewon;Chae, Beomseok;Lee, Kihyun;Suh, Yongsug
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.20 no.5
    • /
    • pp.410-420
    • /
    • 2015
  • This paper provides a comparison of power converter loss and thermal description for voltage source and current source type 5 MW-class medium-voltage topologies of wind turbines. Neutral-point clamped three-level converter is adopted for a voltage source type topology, whereas a two-level converter is employed for current source type topology, considering the popularity in the industry. To match the required voltage level of 4160 V with the same switching device of IGCT as in the voltage source converter, two active switches are connected in series for the case of current source converter. Transient thermal modeling of a four-layer Foster network for heat transfer is done to better estimate the transient junction and case temperature of power semiconductors during various operating conditions in wind turbines. The loss analysis is confirmed through PLECS simulations. Comparison result shows that the VSC-based wind turbine system has higher efficiency than the CSC under the rated operating conditions.

Orthotropic magneto-thermoelastic solid with multi-dual-phase-lag model and hall current

  • Lata, Parveen;Himanshi, Himanshi
    • Coupled systems mechanics
    • /
    • v.10 no.2
    • /
    • pp.103-121
    • /
    • 2021
  • The present research deals with the investigation of the effect of hall current in an orthotropic magneto-thermoelastic medium with two temperature in the context of multi-phase-lag heat transfer due to thermomechanical sources. The bounding surface is subjected to linearly distributed and concentrated loads(mechanical and thermal source).Laplace and Fourier transform techniques are used to solve the problem. The expressions for displacement components,stress components and conductive temperature are derived in transformed domain and furtherin physical domain with the help of numerical inversion techniques. The effect ofrotation and hall parameter hasshown with the help of graphs.

isolation of Xylanase-producing Thermo-tolerant Bacillus sp. and Its Enzyme Production (Xylanase를 생산하는 내열성 Bacillus속 균주의 분리와 효소생산 조건)

  • 박영서;강미영;장학길;박귀근;강종백;이정기;오태광
    • Microbiology and Biotechnology Letters
    • /
    • v.27 no.5
    • /
    • pp.370-377
    • /
    • 1999
  • Thermo-tolerant bacterium producing the xylanase was isolated from soil and identified as Bacillus pumilus. This strain, named Bacillus pumilus TX703, was able to grow ad produce xylanase at the culture temperature of 5$0^{\circ}C$. The maximum xylanase production was obtained when 1%(w/v) birchwood xylan and 1% (w/v) soytone were used as carbon source and nitrogen source, respectively. The biosynthesis of xylanase was under the catabolite repression induced by glucose in the culture medium, and it was completely inhibited in the presence of 0.2% (w/v) glucose. The maximum activity of xylanase was observed from pH8.0 to 9.0 and from 50 to 6$0^{\circ}C$ and the enzyme was highly heat-stable, whose activity remained was over 50% at 8$0^{\circ}C$, and was quite stable from pH5.0 to 10.0.

  • PDF

APPLICATION OF PRODUCT OF THE MULTIVARIABLE A-FUNCTION AND THE MULTIVARIABLE SRIVASTAVA'S POLYNOMIALS

  • Kumar, Dinesh;Ayant, Frederic;Choi, Junesang
    • East Asian mathematical journal
    • /
    • v.34 no.3
    • /
    • pp.295-303
    • /
    • 2018
  • Gautam et al. [9] introduced the multivariable A-function, which is very general, reduces to yield a number of special functions, in particular, the multivariable H-function. Here, first, we aim to establish two very general integral formulas involving product of the general class of Srivastava multivariable polynomials and the multivariable A-function. Then, using those integrals, we find a solution of partial differential equations of heat conduction at zero temperature with radiation at the ends in medium without source of thermal energy. The results presented here, being very general, are also pointed out to yield a number of relatively simple results, one of which is demonstrated to be connected with a known solution of the above-mentioned equation.

Non Darcy Mixed Convection Flow of Magnetic Fluid over a Permeable Stretching Sheet with Ohmic Dissipation

  • Zeeshan, A.;Majeed, A.
    • Journal of Magnetics
    • /
    • v.21 no.1
    • /
    • pp.153-158
    • /
    • 2016
  • This paper aims to discuss the Non Darcy boundary layer flow of non-conducting viscous fluid with magnetic ferroparticles over a permeable linearly stretching surface with ohmic dissipation and mixed convective heat transfer. A magnetic dipole is applied "a" distance below the surface of stretching sheet. The governing equations are modeled. Similarity transformation is used to convert the system of partial differential equations to a system of non-linear but ordinary differential equations. The ODEs are solved numerically. The effects of sundry parameters on the flow properties like velocity, pressure, skin-friction coefficient and Nusselt number are presented. It is deduced the frictional resistance of Lorentz force decreases with stronger electric field and the trend reverses for temperature. Skin friction coefficient increase with increase in ferromagnetic interaction parameter. Whereas, Nusselt number decrease.