• Title/Summary/Keyword: Medium power system

Search Result 501, Processing Time 0.025 seconds

7-Level Medium Voltage Inverter System with PWM Converter for Regenerating Operation (회생능력을 가지는 7-레벨 고압인버터 시스템)

  • Kim Kwang-Seob;Bang Sang-Suk;Kwon Byung-Ki;Moon Sang-Ho;Yang Byung-Hun;Lee Myung-Jun;Choi Chang-Ho
    • Proceedings of the KIPE Conference
    • /
    • 2006.06a
    • /
    • pp.128-130
    • /
    • 2006
  • We introduce 2[MVA] 3300[V] 7-level voltage source inverter system developed by POSCON and describe the main characteristics of inverter system i.e. PWM converter, H-bridge power module, phase shifted carrier PWM The PWM converter is a three-phase boost converter, which operates in a 4-quadrant and in a nearly unit displacement power factor. Experimental waveforms are also presented to verify the proposed method and performance of the developed system.

  • PDF

Development of a Customized CAM System for CNC Glass Scribing Machine (유리재단 전용 CAM 시스템 개발)

  • 이건범
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.7 no.1
    • /
    • pp.126-134
    • /
    • 1998
  • In order to increase the modeling power and productivity of CAD/CAM systems, demands for customization of CAD/CAM system increased. Customization of a CAM system involves making it easier to learn and use, adding new modeling features not supported in a general purpose CAM system, and providing parametric inputting mechanism. A customization from a commercial CAM system (OMEGA) has implemented for two dimensional free curve CNC glass scribing machine of medium size company in Cheonan. A CAD technician who has no CAM experience can operate this customized CAM system satisfactorily.

  • PDF

Study on cognitive load of OM interface and eye movement experiment for nuclear power system

  • Zhang, Jingling;Su, Daizhong;Zhuang, Yan;QIU, Furong
    • Nuclear Engineering and Technology
    • /
    • v.52 no.1
    • /
    • pp.78-86
    • /
    • 2020
  • The operation and monitoring (OM) interface is the digital medium between nuclear power system and operators. The cognitive load of OM interface has an important effect on the operation errors made by operator during OM task between operator and computer. The cognitive load model of OM interface is constructed for analysing the composition and influencing factors of OM interface cognitive load. And to study the coping strategies and methods for cognitive load of nuclear power system. An experiment method based on eye movement is proposed to measure the cognitive load of OM interface. Experiment case is carried out with 20 subjects and typical OM interface of a nuclear power system simulator. The OM interface is optimized based on the experiment results. And the results comparison between the original OM interface and the optimized OM interface shows that the cognitive load model and proposed method is valuable contributions in reducing the cognitive load and improving the interaction efficiency of OM tasks.

A Study on the Design of Discharge Voltage of Discharge Element with Control Electrode (제어전극을 갖는 방전소자의 방전개시전압 설계에 관한 연구)

  • Park, Keun-Seok;Choi, Jun-Woong;Lee, Dae-Dong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.11
    • /
    • pp.1512-1516
    • /
    • 2018
  • The power system and control system constantly reveals surge voltage such as switching surge of lighting devices and power conversion devices, operating and stops surge of rotating devices, charge & discharge surge, opening & closing surge of circuit breakers and the like. Such a surge voltages can cause damage or malfunction of the element such as CPU, Memory, semiconductor etc. In the industry, in order to protect the system from the surge voltage, a surge protector with low discharge starting voltage, fast response time, and low capacitance is required, and technical development research for that is ongoing. In this paper, in order to solve the problem of the existing GDT discharge tube not discharging from the transient voltage which is higher than the commercial voltage and lower than the discharge voltage of the discharge element, we have developed a discharge element having the control electrode & control circuit. The discharge element having the control electrode and the control circuit can control the discharge voltage according to the needs of the consumer and can satisfy the requirement of the discharge element and the technology of the surge protector downsizing technology and the surge protection technology. It is judged to be effective for development.

THERMAL-FLUID ANALYSIS FOR COOLING PERFORMANCE IMPROVEMENT OF 3.3KV(105A) COMPACT RACK TYPE MEDIUM VOLTAGE INVERTER SYSTEM (3.3kV(105A) COMPACT RACK TYPE 고압 인버터 시스템의 방열 성능 향상을 위한 열유동 해석)

  • Kim, S.Y.;Kim, S.D.;Ryoo, S.R.;You, N.K.;Kim, T.B.;Hong, C.O.;Ko, H.S.
    • Journal of computational fluids engineering
    • /
    • v.19 no.3
    • /
    • pp.24-28
    • /
    • 2014
  • With ever rising concerns about saving of fossil fuel resource, there have been an increasing demand for use of energy more efficiently. The electric motor driven inverters can be a great help to improve energy efficiency. They are also used to control the motor speed to the actual need. Therefore the use of them can lead to reduce energy consumption. In particular, the medium voltage(MV) drive systems used for pumps, fans, steel rolling mills and tractions have widespread applications in the industry. They cover power ratings from 0.4MW to 40MW at the MV level of 2.3kV to 13.8kV. The majority of the installed MV drive systems however, are in the 1MW to 4MW range with voltage rating from 3.3kV to 6.6kV. But they are required to reduce size and weight like other power electronic equipments. In this paper, we studied on the 3.3kV(105A) compact rack type inverter system for improving the cooling efficiency. At first, we confirmed the tendency of temperature with computational simulation using ANSYS ICEPAK and actual experimental tests. And then we researched thermal performance improvement designs in order to reduce temperature of the transformer for the safe operation. It can reduce temperature of transformer that using pipe type flow guide in the system. As a result, we found out more efficient solution by thermal-fluid analysis.

High-Efficiency & Cost-Effective Multi-Output LLC Resonant Converter using Single Transformer (단일 변압기를 이용한 고효율.저가격형 다중출력 LLC 공진형 컨버터)

  • Cho, Sang-Ho;Yoon, Jong-Kyu;Roh, Chung-Wook;Hong, Sung-Soo;Kim, Jong-Hae;Lee, Hyo-Bum;Han, Sang-Kyu
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.13 no.6
    • /
    • pp.439-446
    • /
    • 2008
  • The medium power system for the recent electronic products that can perform the multi-function requires various multi-output, high-efficiency and low cost characteristics. To cope with these critical issues, a new high-efficiency and cost-effective multi-output LLC resonant converter is proposed in this paper. The proposed converter requires only 1 power switch instead of the bulky and expensive non-isolated DC/DC converter. Therefore, it features a simple structure, lower cost and high-efficiency. Especially, since the proposed converter can ensure the ZVS or ZCS of all power switches, it has very desirable advantages such as more improved EMI characteristics and reduced switching losses. Finally, to confirm the operation, validity, and features of the proposed circuit, experimental results from a SMPS prototype for 42" FHD PDP TV are presented.

Performance Evaluation with Protective Function test of Inverter for Solar Power Generation (태양광발전용 인버터 보호기능시험 성능평가)

  • Yoon, Yong-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.11
    • /
    • pp.1570-1575
    • /
    • 2018
  • The increased penetration of PV is impacting on grid operation and in particular the voltage within the local grid can be significantly influenced by the various PV systems. The increased penetration of PV is impacting on grid operation and in particular the voltage within the local grid can be significantly influenced by the various PV systems. This paper describes domestic technical standard of Photovoltaic(PV) PCS(Power Conditioning Systems)- Characteristics of the utility interface. Especially protective function test items of 1) Output overvoltage protection test, 2) Output undervoltage protection test, 3) Frequency rise protection test, 4) Frequency fall protection test, 5) System voltage's momentary interruptions, 6) System voltage distortion capability test. Therefore in this paper protective function test item of facilities evaluation detailed standards for new renewable energy, small, medium and large photovoltaic inverter standard is studied and analyzed and finally full tested by PV inverter performance function.

The effects of SCOPF solution to Transient Stability on Voltage Limited Power System (전압안정도로 제약된 계통에서 최적조류계산해가 과도안정도에 미치는 영향)

  • Lee, Geun-Joon;Kim, Bal-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2001.05a
    • /
    • pp.245-247
    • /
    • 2001
  • This paper presents a series of simulation results of transient stability on SCOPF operated power system whose transmission capabilities are limited by voltage stability. Three steps of voltage security guidelines, 5[%], 7[%], 10[%] are introduced to increase power transfer from generation centers to load center and observed the effects of voltage guidelines to transient stability for three kinds of load level(peak, medium, off-peak). As a result, dynamic characteristics weren't affected by the voltage security limits in model system, but became worse for the off-peak level than peak case, and sustain oscillations are observed for the all load level. This gives us some intitutions for the development and applications of security limits to use SCOPF program in open electric market.

  • PDF

Design of A High-Speed Current-Mode Analog-to-Digital Converter (고속 전류 구동 Analog-to-digital 변환기의 설계)

  • 조열호;손한웅;백준현;민병무;김수원
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.31B no.7
    • /
    • pp.42-48
    • /
    • 1994
  • In this paper, a low power and high speed flash Analog-to-Digital Converter using current-mode concept is proposed. Current-mode approach offers a number of advantages over conventional voltage-mode approach, such as lower power consumption small chip area improved accuracy etc. Rescently this concept was applied to algorithmic A/D Converter. But, its conversion speed is limited to medium speed. Consequently this converter is not applicable to the high speed signal processing system. This ADC is fabricated in 1.2um double metal CMOS standard process. This ADC's conversion time is measured to be 7MHz, and power consumption is 2.0mW, and differential nonlinearity is less than 1.14LSB and total harmonic distortion is -50dB. The active area of analog chip is about 350 x 550u$m^2$. The proposed ADC seems suitable for a single chip design of digital signal processing system required high conversion speed, high resolution small chip area and low power consumption.

  • PDF

A Study on Methods of Interference Avoidance between Power Line Communications and Radio Communications (고속전력선통신과 무선통신간의 간섭 회피 방법에 대한 연구)

  • Jang, Dong-Won;Lee, Young-Hwan
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2007.08a
    • /
    • pp.223-226
    • /
    • 2007
  • This paper first outlines the technology used in Power Line Communications(PLC) systems, and the political support being offered to the technology, from the point of view of its effect on electromagnetic compatibility (EMC). The radio spectrum needs protection from other interferers, and there is a regime in place to provide this interference avoidance/mitigation. Nevertheless, PLC has several features that mean that it is capable of creating such interference. These features are discussed, and some published field trial results are reviewed. Difficulties in achieving compatibility between the requirements for radio protection and the requirements for operation of the PLC system mean that there is no consensus as yet as to how PLC system components can be made compliant with EMC requirements. It is concluded that there is little prospect of an accommodation between the competing demands, so that if PLC is to become widespread it will be at the expense of the radio environment.

  • PDF