Analysis of operation performance of PHILS-based superconducting current limiter connected to MVDC system

  • Seok-Ju Lee;Jae In Lee
    • Progress in Superconductivity and Cryogenics
    • /
    • v.25 no.4
    • /
    • pp.54-59
    • /
    • 2023
  • In this paper, we analyze experimental results by applying the PHILS model to a lab-scale superconducting current limiter system for its actual application in medium-voltage direct current (MVDC) systems. Superconducting current limiters exhibit effective current-limiting performance in circuit breaker operations, particularly in limiting large fault currents within a short period, addressing the challenges posed by the increasing use of renewable energy and the integration of DC medium-voltage distribution systems. The development of such superconducting current limiters faces various technical and cost disadvantages, especially when applying a medium-voltage 35kV level system, which is intended for future introduction. The proven lab-scale superconducting current limiter system and the PHILS model are combined and integrated into the actual system. Our plan involves analyzing the limiter's performance, assessing its impact on the system, and preparing for its application in future medium-voltage systems. Utilizing RTDS, a simulation was conducted by connecting actual scaled-down equipment and systems, with the analysis results presented.

RF Channel Characteristics of the Medium-voltage Power Line for PLC (전력선통신을 위한 중 전압용 전력선의 RF채널 특성)

  • Kim, Seon-Hyo;Kim, Gwan-Ho;Lee, Hyeong-Cheol;Sin, Cheol-Jae
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.51 no.7
    • /
    • pp.316-321
    • /
    • 2002
  • In this Paper, the channel characteristics of the medium voltage(22.9kV) power line to analysis the broadband power line communication in the frequency range up to 30MHz was measured. With the sideband electrical coupler in the operating frequency range from DC to 30MHz, we measured characteristic impedance, noise and attenuation of the medium voltage power line, and then characteristic impedance was measured at the state of unloaded medium voltage power line by Scattering parameter method of Vector Network Analyzer. As a measurement result, Channel impedance shows 100~380$\Omega$ at the less than 15MHz and 70~230$\Omega$ at the more than 15 MHz. Noise characteristics of power line shows -75dBm at 20MHz and Narrowband interference noise was from 3 MHz to 7MHz.

Mitigation of high energy arcing faults in nuclear power plant medium voltage switchgear

  • Chang, Choong-koo
    • Nuclear Engineering and Technology
    • /
    • v.51 no.1
    • /
    • pp.317-324
    • /
    • 2019
  • A high energy arcing fault event occurred in the medium-voltage (13.8 kV and 4.16 kV) metalclad switchgears in a nuclear power plant not only affecting switchgear but also connected equipment due to the arc energy. The high energy arcing fault also causes a fire that influences the safety function of the unit. Therefore, from the safety point of view, it is necessary to evaluate the influences of high energy arcing fault events on the safety functions of nuclear power plants. The purpose of this paper is to elaborate the characteristics of high energy arcing faults and propose a high energy arcing fault mitigation scheme for medium voltage networks in nuclear power plants.

Development of Signal Coupler for Power Line Communication over Medium Voltage Distribution Line (고압 배전선로 전력선 통신 신호결합장치 개발)

  • Lee Jae-Jo;Park Young-Jin;Oh Hui-Myoung;Kim Kwan-Ho;Lee Dae-Young
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.54 no.6
    • /
    • pp.409-416
    • /
    • 2005
  • For broadband high-data-rate power line communication with the allocated frequency bandwidth from 2 to 30 MHz on medium voltage (MV) distribution power lines, a signal coupling unit is developed. The coupling unit is composed of a coupling capacitor for coupling communication signal, a drain coil, and an impedance matching part. The coupling capacitor made of ceramic capacitor is designed for transmission property of better than 1 dB in the frequency range. The drain coil is used for preventing low frequency high voltage from junction of medium voltage power line in case that a coupling capacitor is not working properly any more. Also, using ferrite core, a novel broadband impedance matching transformer is developed. A complete coupling unit with a coupling capacitor, a drain coil, and a matching transformer is housed by polymer for good isolation and distinguishing from high voltage electric facilities. Each is fabricated and its frequency behavior is tested. Finally, complete signal couplers are equipped in a MV PLC test bed and their performance are measured. The measurement shows that the coupling capacitor works excellently.

Hybrid-Boost Modular Multilevel Converter-Based Medium-Voltage Multiphase Induction Motor Drive for Subsea Applications

  • Daoud, Mohamed;Elserougi, Ahmed;Massoud, Ahmed;Bojoi, Radu;Abdel-Khalik, Ayman;Ahmed, Shehab
    • Journal of Power Electronics
    • /
    • v.19 no.3
    • /
    • pp.714-726
    • /
    • 2019
  • This paper proposes a hybrid-boost Modular Multilevel Converter (MMC) for the Medium-Voltage (MV) Variable Speed Drives (VSDs) employed in subsea applications, such as oil and gas recovery. In the presented architecture, a hybrid-boost MMC with a reduced number of semiconductor devices driving a multiphase Induction Machine (IM) is investigated. The stepped output voltage generated by the MMC reduces or eliminates the filtering requirements. Moreover, the boosting capability of the proposed architecture eliminates the need for bulky low-frequency transformers at the converter output terminals. A detailed illustration of the hybrid-boost MMC operation, the expected limitations/constraints, and the voltage balancing technique are presented. A simulation model of the proposed MV hybrid-boost MMC-based five-phase IM drive has been built to investigate the system performance. Finally, a downscaled prototype has been constructed for experimental verification.

A Medium-Voltage Matrix Converter Topology for Wind Power Conversion with Medium Frequency Transformers

  • Gu, Chunyang;Krishnamoorthy, Harish S.;Enjeti, Prasad N.;Zheng, Zedong;Li, Yongdong
    • Journal of Power Electronics
    • /
    • v.14 no.6
    • /
    • pp.1166-1177
    • /
    • 2014
  • A new type of topology with medium-frequency-transformer (MFT) isolation for medium voltage wind power generation systems is proposed in this paper. This type of converter is a high density power conversion system, with high performance features suitable for next generation wind power systems in either on-shore or off-shore applications. The proposed topology employs single-phase cascaded multi-level AC-AC converters on the grid side and three phase matrix converters on the generator side, which are interfaced by medium frequency transformers. This avoids DC-Link electrolytic capacitors and/or resonant L-C components in the power flow path thereby improving the power density and system reliability. Several configurations are given to fit different applications. The modulation and control strategy has been detailed. As two important part of the whole system, a novel single phase AC-AC converter topology with its reliable six-step switching technique and a novel symmetrical 11-segment modulation strategy for two stage matrix converter (TSMC) is proposed at the special situation of medium frequency chopping. The validity of the proposed concept has been verified by simulation results and experiment waveforms from a scaled down laboratory prototype.

A Study On The Characteristics Of The Medium Voltage Power Distribution Line Channel By Wideband Channel Impulse Response Measurement Using PN Sequence (PN 시퀀스 방식의 광대역 임펄스 응답 측정을 통한 고압 배전선로 채널 특성 연구)

  • Oh Hui-Myoung;Choi Sung-Soo;Lee Jae-Jo;Kim Kwan-Ho;Whang Keum-Chan
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.54 no.1
    • /
    • pp.56-60
    • /
    • 2005
  • In the power-line communication(PLC) systems, the power line is a wired medium. However, the power line channel has the multi-path fading characteristics like the wireless channel in the wireless communication systems because it has the signal reflection and divergence by the impedance mismatching between many branch lines and loads. So the analysis of the multi-path characteristics is very important, and it has been doing by the several measurement methods for the impulse response between the transmitter and the receiver. PN sequence method has originally been used as a wideband impulse response measurement mettled for wireless channel, but it is recently being applied to not only the wireless channel but also the wired channel like the power line channel. This method is more useful and effective for the long distance communication channel like the medium voltage power distribution line with the multi-paths[1]. In this thesis, we have measured impulse response for the medium voltage power distribution line channel by the wideband measurement method using PN sequence, analytically studied the measured data and presented the results.

Impedance Measurement and Matching Technique for Medium-Voltage Powerline Communication (고압전력선 통신을 위한 임피던스 측정 및 정합 방안 연구)

  • 이재조;유정훈;홍충선;이대영
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.53 no.5
    • /
    • pp.345-352
    • /
    • 2004
  • Currently, high data rate PLC(Power Line Communications), up to 100 Mbps, which use frequency bandwidth between 2 MHz and 30 MHz is investigated very hard, and commercial PLC modem for low voltage powerline network (indoor) is coming soon into communication market. For the purpose of developing a fit communication system which has little distortion of signal and attenuation, it is surely necessary to know about channel environments of powerline. Especially, the impedance measurement of the powerline and impedance matching are very important. As is known, since medium-voltage powerline (22.9 ㎸) is still working, it is not so simple to measure the powerline impedance. In our study, a portable impedance measurement equipment is developed. It consists of coupling capacitor, a drain coil and impedance matching transformer. The equipment is easily connected to medium voltage line and impedance of power line is measured using a network analyzer. Also, measurement results are used for impedance matching of PLC signal. In fact, matching transformer with several different impedances are used. The matching transformer is connected between coupling capacitor and signal port. In this paper, the developed portable impedance measurement equipment and impedance measurement results are presented. Also impedance matching technique using matching transformers will be explained. We showed the result of the improved performance by the impedance matching.

Medium Voltage Resonant Converter with Balanced Input Capacitor Voltages and Output Diode Currents

  • Lin, Bor-Ren;Du, Yan-Kang
    • Journal of Power Electronics
    • /
    • v.15 no.2
    • /
    • pp.389-398
    • /
    • 2015
  • This paper presents a 1.92 kW resonant converter for medium voltage applications that uses low voltage stress MOSFETs (500V) to achieve zero voltage switching (ZVS) turn-on. In the proposed converter, four MOSFETs are connected in series to limit the voltage stress of the power switches at half of the input voltage. In addition, three resonant circuits are adopted to share the load current and to reduce the current stress of the passive components. Furthermore, the transformer primary and secondary windings are connected in series to balance the output diode currents for medium power applications. Split capacitors are adopted in each resonant circuit to reduce the current stress of the resonant capacitors. Two balance capacitors are also used to automatically balance the input capacitor voltage in every switching cycle. Based on the circuit characteristics of the resonant converter, the MOSFETs are turned on under ZVS. If the switching frequency is less than the series resonant frequency, the rectifier diodes can be turned off under zero current switching (ZCS). Experimental results from a prototype with a 750-800 V input and a 48V/40A output are provided to verify the theoretical analysis and the effectiveness of the proposed converter.

Development of channel characteristics measurement system for Medium Voltage Power Line Grid (고압전력선 통신 채널 특성 측정 시스템 개발)

  • Lee, Jae-Jo;Lee, Won-Tae;Oh, Hui-Myoung;Kim, Kwan-Ho;Lee, Dae-Young
    • Proceedings of the KIEE Conference
    • /
    • 2002.07d
    • /
    • pp.2640-2642
    • /
    • 2002
  • In this paper, we show the channel characteristics measurement system the frequency range up to 30MHz for medium voltage Power Line Grid. Power line channel characteristics are investigated by means of various measurement instruments. Measurement system consists of medium voltage coupler, impedance measurement part, noise measurement part, voltage sensing part and communication part. Measured data will be used for PLC channel modeling and PLC network system design.

  • PDF