• Title/Summary/Keyword: Medical electron

Search Result 821, Processing Time 0.03 seconds

Eine Structure of Digital Arteries in Rat (흰쥐 수지동맥의 미세구조에 관한 연구)

  • Kim, Baik-Yoon;Shin, Keun-Nam
    • Applied Microscopy
    • /
    • v.29 no.1
    • /
    • pp.83-94
    • /
    • 1999
  • The ultrastructure of small arterioles and capillaries in the lumbrical muscles of rat digits were studied by electron microscopy and following results were obtained. 1. The diameter of small arterioles of rat digits were $12\sim20{\mu}m$, and it was relatively smaller than human $(30\sim35{\mu}m)$. 2. All the endothelial cells of small arterioles and capillaries in the lumbrical muscles of rat digits were continuous type, and they had typical morphological characteristics of continuous endothelial cells : numerous cytoplasmic pinocytic vesicles and many tight junctions between the endothelial cells. 3. In the small arterioles subendothelial layers were irregularly spaced beneath the basal lamina, and membrane to membrane contacts were found between the endothelial cells and smooth muscle cells. 4. Pericytes were often found nearby capillary endothelium, and their cytoplasmic processes surrounded part of endothelial cells. They were enclosed by basal lamina. 5. Smooth muscle cells in tunica media of small arterioles were only one layered, that is, they were terminal arterioles. Sarcoplasm of smooth muscle cell was divided to 2 areas; homogeneous or filamentous area and non-homogeneous perinuclear area. 6. The tunica adventitia contained fibroblasts with extremely attenuated cytoplasmic processes and collagen fibirls.

  • PDF

Antioxidant Effects and Application as Natural Ingredients of Korean Sanguisorbae officinalis L. (한국산 지유(地楡)(Sanguisorbae officinalis L.)의 항산화 효과 및 천연소재로서의 활용방안)

  • Lee, Jin-Tae;Lee, Soon-Ae;Kwak, Jae-Hoon;Park, Jung-Mi;Lee, Jin-Young;Son, Jun-Ho;An, Bong-Jeun
    • Applied Biological Chemistry
    • /
    • v.47 no.2
    • /
    • pp.244-250
    • /
    • 2004
  • Biological activities and application of Sanguisorbae officinalis L. were investigated. In the enzymological physiological activities, the electron donating ability (EDA) was 54.9% in 10 ppm and it was over 90% over 50 ppm and SOD-like activity was high as 65.4% in 1000 ppm, it was gradual increased. As inhibitory effect of xanthine oxidase, it was 17.9% in 200 ppm and little low as 36.9% in 500 ppm and inhibitory effect of tyrosinase. As the result of measuring the lipid oxidation, all the concentrations of medical ion treatments had the ability to keep it from acidification and metal ion blocking effects about the lipid oxidation promoting factors ($Fe^{2+}$ and $Cu^{2+}$), $Fe^{2+}$ was better than $Cu^{2+}$ and all concentrations of medical ion treatments was 40% in 50 ppm. When it was applied into normal skin-softener it showed safe effect so that we can expect that as the natural material of cosmetics.

Effect of Drug Eluting Uniformity for Biodegradable Stent by Solid Freeform Fabrication (쾌속조형기법을 이용한 생분해성 스텐트용 메쉬필름의 약물방출거동 효과)

  • Cheong, Sin Young;Kim, Yang Eun;Koh, Young Joo;Shin, Wang Soo;Lee, Jun Hee;Kim, Wan Doo;Yoo, Young Eun;Park, Su A
    • Polymer(Korea)
    • /
    • v.38 no.1
    • /
    • pp.93-97
    • /
    • 2014
  • Biodegradable drug-eluting stent has dual functions of supporting the lumen and treating internal tumor preventing the restenosis by releasing drug. In this study, the polycaprolactone (PCL) based three dimensional (3D) mesh loaded with paclitaxel (PTX) was presented by rapid prototyping (RP) technique of solid freeform fabrication (SFF) for biodegradable drug-eluting stent application. PCL has many advantageous properties such as good biocompatibility, good mechanical properties, and good drug permeability. PTX is widely used in the cancer treatment by inhibiting tumor cell proliferation. Analytical methods of HPLC and NMR were used for simultaneous quantification of PTX. Scanning electron microscopy (SEM) was performed to observe the architecture and morphologies of 3D mesh. The cytotoxicity assay results indicated released PTX's biological activity. This study provided that PCL based 3D mesh loaded with PTX by RP technique has great potential for biodegradable drug-eluting stent application.

The Properties of Beam Intensity Scanner (BInS) for Dose Verification in Intensity Modulated Radiation Therapy (방사선 세기 조절 치료에서 선량을 규명하는 데 사용된 BlnS System의 특성)

  • 박영우;박광열;박경란;권오현;이명희;이병용;지영훈;김근묵
    • Progress in Medical Physics
    • /
    • v.15 no.1
    • /
    • pp.1-8
    • /
    • 2004
  • Patient dose verification is one of the most Important responsibilities of the physician in the treatment delivery of radiation therapy. For the task, it is necessary to use an accurate dosimeter that can verify the patient dose profile, and it is also necessary to determine the physical characteristics of beams used in intensity modulated radiation therapy (IMRT) The Beam Intensity Scanner (BInS) System is presented for the dosimetric verification of the two dimensional photon beam. The BInS has a scintillator, made of phosphor Terbium-doped Gadolinium Oxysulphide (Gd$_2$O$_2$S:Tb), to produce fluorescence from the irradiation of photon and electron beams. These fluoroscopic signals are collected and digitized by a digital video camera (DVC) and then processed by custom made software to express the relative dose profile in a 3 dimensional (3D) plot. As an application of the BInS, measurements related to IWRT are made and presented in this work. Using a static multileaf collimator (SMLC) technique, the intensity modulated beam (IMB) is delivered via a sequence of static portals made by controlled leaves. Thus, when static subfields are generated by a sequence of abutting portals, the penumbras and scattered photons of the delivered beams overlap in abutting field regions and this results in the creation of “hot spots”. Using the BInS, inter-step “hot spots” inherent in SMLC are measured and an empirical method to remove them is proposed. Another major MLC technique in IMRT, the dynamic multileaf collimator (DMLC) technique, has different characteristics from SMLC due to a different leaf operation mechanism during the irradiation of photon and electron beams. By using the BInS, the actual delivered doses by SMLC and DMLC techniques are measured and compared. Even if the planned dose to a target volume is equal in our experimental setting, the actual delivered dose by DMLC technique is measured to be larger by 14.8% than that by SMLC, and this is due to scattered photons and contaminant electrons at d$_{max}$.

  • PDF

Radiation Therapy in Elderly Skin Cancer (노령의 피부암에서 방사선치료)

  • Kim, Jin-Hee
    • Radiation Oncology Journal
    • /
    • v.26 no.2
    • /
    • pp.113-117
    • /
    • 2008
  • Purpose: To evaluate the long term results(local control, survival, failure, and complications) after radiation therapy for skin cancer in elderly patients. Material and Methods: The study spanned from January 1990 to October 2002. Fifteen elderly patients with skin cancer were treated by radiotherapy at the Keimyung University Dongsan Medical Center. The age distribution of the patients surveyed was 72 to 95 years, with a median age of 78.8 years. The pathologic classification of the 15 patients included squamous cell carcinoma(10 patients), basal cell carcinoma(3 patients), verrucous carcinoma(1 patient) and skin adnexal origin carcinoma(1 patient). The most common tumor location was the head(13 patients). The mean tumor diameter was 4.9 cm(range 2 to 9 cm). The radiation dose was delivered via an electron beam of 6 to 15 MeV. The dose range was adjusted to the tumor diameter and depth of tumor invasion. The total radiation dose ranged from $50{\sim}80$ Gy(mean: 66 Gy) with a 2 Gy fractional dose prescribed to the 80% isodose line once a day and 5 times a week. One patient with lymph node metastasis was treated with six MV photon beams boosted with electron beams. The length of the follow-up periods ranged from 10 to 120 months with a median follow-up period of 48 months. Results: The local control rates were 100%(15/15). In addition, the five year disease free survival rate(5YDFS) was 80% and twelve patients(80%) had no recurrence and skin cancer recurrence occurred in 3 patients(20%). Three patients have lived an average of 90 months($68{\sim}120$ months) without recurrence or metastasis. A total of 9 patients who died as a result of other causes had a mean survival time of 55.8 months after radiation therapy. No severe acute or chronic complications were observed after radiation therapy. Only minor complications including radiation dermatitis was treated with supportive care. Conclusion: The results suggest that radiation therapy is an effective and safe treatment method for the treatment of skin cancer in elderly patients who achieved a good survival rate and few minor complications.

AN EXPERIMENTAL STUDY ON THE MICROTENSILE BONDING STRENGTH OF DENTIN TREATED BY $CARISOLV^{TM}$ ($Carisolv^{TM}$ 에 의한 우식제거후 Microtensile Bonding Strength에 관한 연구)

  • Baik, Byeong-Ju;Kwon, Byoung-Woo;Kim, Jae-Gon;Cheon, Cheol-Wan
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.29 no.3
    • /
    • pp.389-396
    • /
    • 2002
  • The purpose of this study was to compare the microtensile bonding strength of chemomechanically excavated dentin($Carisolv^{TM}$) to conventional caries removal(bur). The following adhesive systems were used; AB: All-Bond 2(3M, USA), PB: Prime & Bond 2.1(Dentsply, DE), AQ: AQ Bond(sun medical, Japan). 42 human molars with occlusal caries were assigned to 6 groups. Sequential caries removal was controlled with laser fluorescence. Each group was devided as follows; group A, B, C were $Carisolv^{TM}$ applied, group D,E,F were bur used. In group A and D, AB was used as a dentin adhesive. group B,E and group C,F was AQ and AQ was used each. The cavity was filled with composite resin(Z-100). The specimens were sectioned vertically into multiple serial 0.7 mm thick slabs. And then those slabs were sectioned into rectangular parts under 0.7 mm width. Finally 0.7-1.0 mm a right hexahedron shape stick become. Microtensile bonding test was carried out with testing apparatus at cross-head speed of $0.5\;mm/min^{-1}$ and fractured surfaces were observed with scanning electron microscope(JSM-6400, Jeol, Japan). The obtained results were summarized as follows ; 1. In the group of caries removal with $Carisolv^{TM}$, micro-tensile bonding strength decreased to $75.8{\sim}80$ percent of bur used group. 2. In the group of caries removal with $Carisolv^{TM}$, decreased degree of micro-tensile bonding strength is not so different in 3 kinds of dentin adhesives(p<0.05). 3. In the group of caries removal with $Carisolv^{TM}$, microtensile bonding strength of AB, PB, AQ was 32.6MPa(2.4), 30.1Mpa (1.8), 21.2Mpa(1.9). 4. In the group of caries removal with Bur and $Carisolv^{TM}$, microtensile bonding strength of AQ was significantly lower than that of AB and PB(p<0.01).

  • PDF

Histological Analysis of Autologous Pericardial Tissue Used as a Small-Diameter Arterial Graft (소구경 동맥이식편으로 사용한 자가심란의 조직학적 분식)

  • Yang Ji-Hyuk;Sung Sang-Hyun;Kim Won-Gon
    • Journal of Chest Surgery
    • /
    • v.39 no.4 s.261
    • /
    • pp.261-268
    • /
    • 2006
  • Background: Current vascular prostheses are still inadequate for reconstruction of small-diameter vessels. Autologous pericardium can be a good alternative for this purpose as it already possesses good blood compatibility and shows a mechanical behavior similar to that of natural arteries. However, the clinical use of autologous pericardial tissue as a small-diameter vascular graft has limitations due to mixed outcomes from uncertain biological behavior and difficulty to gain reliable patency results in animal experiments. To study this issue, we implanted fresh and glutaraldehyde-treated autologous pericardium as small-diameter arterial grafts in dogs, and compared their time-related changes histologically. Material and Method: As a form of 5mm-diameter arterial graft, one pair of autologous pericardial tissue was used for comparison between the glutaraldehyde-treated and the glutaraldehyde-untreated grafts in the bilateral carotid arteries in the same dog. The patency of the grafts were evaluated at regular intervals with Doppler ultrasonography. After the predetermined periods of 3 days, 2 weeks, 1 month, 3 months and 6 months, the grafts in each animal were explanted. The retrieved grafts were processed for light and electron microscopic analyses following gross observation. Result: Of 7 animals, 2 were excluded from the study because one died postoperatively due to bleeding and the other was documented as one side of the grafts being obstructed. All 10 grafts in the remaining 5 dogs were patent. Grossly, a variable degree of thromboses were observed in the luminal surfaces of the grafts at 3 days and 2 weeks, despite good patency. Pseudointimal smooth blood-contacting surfaces were developed in the grafts at f month and later. By light microscopy, mesothelial cell layers of the pericardial tissue were absent in all explanted grafts. Newly formed endothelial cell layers on the blood-contacting surface were observed in both the glutaraldehyde-treated and fresh grafts at 3 months and later. The collagen fibers became degraded by fragmentation in the fresh graft at 1 month and In the glutaraldehyde-treated graft at 3 months. At 6 months, the collagen layers were no longer visible in either the glutaraldehyde-treated or fresh grafts. By electron microscopy, a greater amount of coarse fibrin fibers were observed in the fresh grafts than in the glutaraldehyde-treated grafts and, more compact and well-arrayed layers were observed in the glutaraldehyde-treated grafts than in the fresh grafts. Conclusion: The glutaraldehyde-treated small-diameter pericardial arterial grafts showed a better endothelialization of the blood-contacting surface and a slower fragmentation of the collagen layers than the fresh grafts, although it has yet to be proven whether these differences are so significant as to affect the patency results between the groups.

Development of Porcine Pericardial Heterograft for Clinical Application (Microscopic Analysis of Various Fixation Methods) (돼지의 심낭, 판막을 이용한 이종이식 보철편의 개발(고정 방법에 따른 조직학적 분석))

  • Kim, Kwan-Chang;Choi, Chang-Hyu;Lee, Chang-Ha;Lee, Chul;Oh, Sam-Sae;Park, Seong-Sik;Kim, Woong-Han;Kim, Kyung-Hwan;Kim, Yong-Jiin
    • Journal of Chest Surgery
    • /
    • v.41 no.3
    • /
    • pp.295-304
    • /
    • 2008
  • Background: Various experimental trials for the development of bioprosthetic devices are actively underway, secondary to the limited supply of autologous and homograft tissue to treat cardiac diseases. In this study, porcine bioprostheses that were treated with glutaraldehyde (GA), ethanol, or sodium dodecylsulfate (SDS) were examined with light microscopy and transmission electron microscopy for mechanical and physical imperfections before implantation, Material and Method: 1) Porcine pericardium, aortic valve, and pulmonary valve were examined using light microscopy and JEM-100CX II transmission electron microscopy, then compared with human pericardium and commercially produced heterografts. 2) Sections from six treated groups (GA-Ethanol, Ethanol-GA, SDS only, SDS-GA, Ethanol-SDS-GA and SDS-Ethanol-GA) were observed using the same methods. Result: 1) Porcine pericardium was composed of a serosal layer, fibrosa, and epicardial connective tissue. Treatment with GA, ethanol, or SDS had little influence on the collagen skeleton of porcine pericardium, except in the case of SDS pre-treatment. There was no alteration in the collagen skeleton of the porcine pericardium compared to commercially produced heterografts. 2) Porcine aortic valve was composed of lamina fibrosa, lamina spongiosa, and lamina ventricularis. Treatment with GA, ethanol, or SDS had little influence on these three layers and the collagen skeleton of porcine aortic valve, except in the case of SDS pre-treatment. There were no alterations in the three layers or the collagen. skeleton of porcine aortic valve compared to commercially produced heterografts. Conclusion: There was little physical and mechanical damage incurred in porcine bioprosthesis structures during various glutaraldehyde fixation processes combined with anti-calcification or decellularization treatments. However, SDS treatment preceding GA fixation changed the collagen fibers into a slightly condensed form, which degraded during transmission electron micrograph. The optimal methods and conditions for sodium dodecylsulfate (SDS) treatment need to be modified.

Estimation of Inhomogeneity Correction Factor in Small Field Dosimetry (소조사면에서의 불균질 물질 보정 계산의 평가)

  • Shin, Hun-Joo;Kang, Young-Nam;Jang, Ji-Sun;Seo, Jae-Hyuk;Jung, Ji-Young;Choi, Byung-Ock;Choi, Ihl-Bohng;Lee, Dong-Joon;Kwon, Soo-Il
    • Progress in Medical Physics
    • /
    • v.20 no.4
    • /
    • pp.260-268
    • /
    • 2009
  • In this study, we estimated inhomogeneity correction factor in small field. And, we evaluated accuracy of treatment planning and measurement data which applied inhomogeneity correction factor or not. We developed the Inhomogeneity Correction Phantom (ICP) for insertion of inhomogeneity materials. The inhomogeneity materials were 12 types in each different electron density. This phantom is able to adapt the EBT film and 0.125 cc ion chamber for measurement of dose distribution and point dose. We evaluated comparison of planning and measurement data using ICP. When we applied to inhomogeneity correction factor or not, the average difference was 1.63% and 10.05% in each plan and film measurement data. And, the average difference of dose distribution was 10.09% in each measurement film. And the average difference of point dose was 0.43% and 2.09% in each plan and measurement data. In conclusion, if we did not apply the inhomogeneity correction factor in small field, it shows more great difference in measurement data. The planning system using this study shows good result for correction of inhomogeneity materials. In radiosurgery using small field, we should be correct the inhomogeneity correction factor, more exactly.

  • PDF

Verification of Skin Dose in Tomotherapy Using the Developed Phantom for Image Based Radiation Treatment System (영상 기반 치료 장비용 팬톰을 이용한 토모테라피 피부 선량 검증)

  • Park, Ji-Yeon;Chang, Ji-Na;Oh, Seung-Jong;Kang, Dae-Gyu;Jung, Won-Gyun;Lee, Jeong-Woo;Jang, Hong-Suk;Kim, Hoi-Nam;Park, Hae-Jin;Kim, Sung-Hwan;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.20 no.2
    • /
    • pp.88-96
    • /
    • 2009
  • Radiation treatment for skin cancer has recently increased in tomotherapy. It was reported that required dose could be delivered with homogeneous dose distribution to the target without field matching using electron and photon beam. Therapeutic beam of tomotherapy, however, has several different physical characteristic and irradiation of helical beam is involved in the mechanically dynamic factors. Thus verification of skin dose is requisite using independent tools with additional verification method. Modified phantom for dose measurement was developed and skin dose verification was performed using inserted thermoluminescent dosimeters (TLDs) and GafChromic EBT films. As the homogeneous dose was delivered to the region including surface and 6 mm depth, measured dose using films showed about average 2% lower dose than calculated one in treatment planning system. Region indicating about 14% higher and lower absorbed dose was verified on measured dose distribution. Uniformity of dose distribution on films decreased as compared with that of calculated results. Dose variation affected by inhomogeneous material, Teflon, little showed. In regard to the measured dose and its distribution in tomotherapy, verification of skin dose through measurement is required before the radiation treatment for the target located at the curved surface or superficial depth.

  • PDF