• Title/Summary/Keyword: Medical electron

Search Result 821, Processing Time 0.029 seconds

Ultrastructure of the Granular Glands in the Amphibian Skin (양서루 피부 과립선의 미세구조)

  • Kim, Han-Hwa;Noh, Yong-Tai;Chung, Young-Wha;Chi, Young-Duk
    • The Korean Journal of Zoology
    • /
    • v.22 no.3
    • /
    • pp.103-114
    • /
    • 1979
  • The authors observed the ultrastructure of the granular glands in the amphibian skin with an electron microscope. The specimens from the experimental animals (Bombina orientalis, Bufo bufo gargarizans, Rana nigromaculata and Rana rugosa) were fixed in 2.5% glutaraldehyde-paraformaldehyde fixative in phosphate buffer at pH 7.2 prior to fixation in 1% osmium tetroxide, dehydrated in graded ethanol and acetone, embedded in Epon 812 mixture, and sectioned with a LKB-ultramicrotome. the ultrathin sections were contrasted with uranyl acetate and lead citrate and observed with a JEOL-100B electron microscope. The results were as follws: 1. The granular gland in the amphibian skin consisted of the glandular epithelial and the myoepithelial cells. 2. The epithelial cells of the granular gland in the amphibian skin consisted of the dark cells but the light cells were also observed in that of Bombina orientalis. 3. The granular glands of the amphibian skin were in holocrine fashion. 4. The nuclei of the epithelial cells of the amphibian cutaneous granular glands were round or oval and showed small and large inforldings of nuclear envelope. Heterochromatins were mainly distributed near the nuclear envelope. Mitochondria were mainly distributed in the perinuclear portion and rough-surfaced endoplasmic reticulums were developed in the cytoplasm but smooth-surfaced endoplasmic reticulums were not well developed. 5. Secretory granules were round or oval and electron-dense and less electron-dense granules were observed. 6. The authors infer that the differences in electron density of the secretory granules in the granular glands of the amphibian skin are due to difference in the concentrations of secretory substances as related to the processes of its formation, and that those chemical components are identical.

  • PDF

Evaluation of the usefulness of Bolus, which combines Step Bolus and 3D Bolus (Step Bolus와 3D Bolus를 combine 한 Bolus의 유용성 평가)

  • Lee, Chang-Suk;Chae, Moon-Ki;Park, Byung-Suk;Kim, Sung-Jin;Joo, Kyoo-Sang;Park, Chul-Yong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.33
    • /
    • pp.79-88
    • /
    • 2021
  • Objectives: Bolus, which combines 3D-bolus and Step-bolus, was produced and its usefulness is evaluated. Materials and Methods: A Bolus was manufactured with a thickness of 10mm and 5mm using a 3D printer (3D printer, USA), and a Step Bolus of 5mm was bonded to a 5mm thick bolus. In order to understand the characteristics of Step bolus and 3D bolus, the differences in relative electron density, HU value, and mass density of the two bolus were investigated. These two Bolus were applied to anthropomorpic phantom to confirm its effectiveness. After all contouring of the phantom, a treatment plan was established using the computed treatment planning system (Eclipse 16.1, Varian medical system, USA). Treatment plan was performed using electron beam 6MeV, nine dose measurement points were designated on the phantom chest, air-gap was measured at that point, and dose evaluation was performed at the same point for each bolus applied using a glass dosimeter (PLD). Results: Bolus, which combines 3D-bolus 5mm and Step-bolus 5mm, was manufactured and evaluated compared with 3D-bolus 1cm. The relative electron density of 3D Bolus was 1.0559 g/cm2 and the step Bolus was 1.0590 g/cm2, which was different by 0.01%, so the relative electron density was almost the same. In the lightweight measurement of air-gap, the combined bolus was reduced to 54.32% for all designated points compared to 3D-bolus. In the dose measurement using a glass dose meter (PLD), the consistency was high in phantom using combined bolus at most points except the slope point. Conclusion: Combined bolus made by combining 3D-bolus and Step-bolus has all the advantages of 3D-bolus and Step-bolus. In addition, by dose inaccuracy due to Air-gap, more improved dose distribution can be shown, and effective radiation therapy can be performed.

A Study on the Dosimetry of the Total Skin Electron Beam Therapy in Cutaneous T-Cell Lymphoma (피부 T 세포림프종의 전 피부 전자선 치료를 위한 dosimetry 연구)

  • 신교철;윤형근
    • Progress in Medical Physics
    • /
    • v.7 no.2
    • /
    • pp.57-65
    • /
    • 1996
  • Total Skin Electron Beam Therapy (TSEBT) is one of the most effective treatment methods for superficially disseminated skin cancer or cutaneous T-cell lymphoma. We have treated a patient with cutaneous T-cell lymphoma. We have used Stanford technique using six dual field. The nominal energy of electron beam was 4MeV. SSD was 390cm and the gantry angles of dual fields were 76$^{\circ}$ and 104$^{\circ}$. The dose profiles of single field and dual fields were measured with films and a Farmer type ion chamber. The field uniformity was 10% over the patient's surface. During treatment, the patient was placed in six different positions for homogenous dose distribution over the body surface. The areas not directly exposed to the path of the electron beam (soles of feet, perineum and vertex of scalp) were boosted with 7MeV electron beam. During the treatment, lens, fingernails and toenails were shielded.

  • PDF

Electron Microscopic Study on the Replcation of Hantaan Virus in Vero-E6 Cells (Vero-E6 세포에서 한탄바이러스의 증식에 관한 전자현미경적 연구)

  • Park, Kyung-Hee;Seong, In-Wha
    • The Journal of Korean Society of Virology
    • /
    • v.29 no.4
    • /
    • pp.201-209
    • /
    • 1999
  • Results of the studies on the morphologic and molecular biologic characteristics of Hantaan virus (HTNV), one of the etiologic agents of Hemorrhagic fever with renal syndrome (HFRS), revealed that HTNV was a member of Family Bunyaviridae and its RNA divided into three segments. And the nucleotide sequences of these segments also were known and the differences in nucleotide sequences of HTNV from other members of genus Hantavirus were clearly evaluated. But the morphorgenesis, pathogenesis of HFRS and the replication time had not been clearly determined. In this study, to estimate the replication time of HTNV in Vero E-6 cells, Vero cells were infected with HTNV 76/118 strain, and cells were harvested from two hours post-infection up to 24 hours at two hours-intervals. Harvested cells were treated with ordinary techniques for electron microscopy and immune-electron microscopy. And then thin sections were observed under transmission electron microscope. HTNV particles were not found in the cytoplasm and in the extracellular space between $2{\sim}8$ hours after inoculation of virus, but virus particles were observed in extracellular space near the cell membrane of Vero-E6 cells 10 hours after infection. In immune electron microscopy, mature HTNV particles in extracellular spaces and immature virus labelled with gold particles in the cytoplasm of Vero E-6 cell 10 hours after infection of HTNV could be seen. This results suggest that the replication time of HTNV might be about 10 hours.

  • PDF

Determination of output factors by 1D method for 6MeV electron (1D 방법에 의한 6MeV 전자선의 output 인자 결정)

  • 유명진
    • Progress in Medical Physics
    • /
    • v.13 no.1
    • /
    • pp.27-31
    • /
    • 2002
  • Output factors for 6MeV electron were directly measured under the condition of an individual beam cutout and these factors were compared with the output factors by 1D method which is an easy means to predict the output factors of electron beam. Output factors by 1D method are defined as output factors of rectangular fields where one side is always equal to the side of the square reference field and the output of an arbitrary rectangular field X, Y is given by the product of the 1D output factors. The output of very large square fields is overestimated using 1D method for the 6MeV electron, but it results in agreement with measured data under the condition of an individual cutout within 1% error adopting a correction factor $CF=C\times$[(X-10)(Y-10)/$\mid$(X-10)(Y-10)$\mid^{1/2}]$.

  • PDF

In Vitro Evaluation of Two Novel Antimalarial Derivatives of SKM13: SKM13-MeO and SKM13-F

  • Thuy-Tien Thi Trinh;Young-ah Kim;Hyelee Hong;Linh Thi Thuy Le;Hayoung Jang;Soon-Ai Kim;Hyun Park;Hak Sung Kim;Seon-Ju Yeo
    • Parasites, Hosts and Diseases
    • /
    • v.60 no.6
    • /
    • pp.401-407
    • /
    • 2022
  • Antimalarial drugs play an important role in the control and treatment of malaria, a deadly disease caused by the protozoan parasite Plasmodium spp. The development of novel antimalarial agents effective against drug-resistant malarial parasites is urgently needed. The novel derivatives, SKM13-MeO and SKM13-F, were designed based on an SKM13 template by replacing the phenyl group with electron-donating (-OMe) or electron-withdrawing groups (-F), respectively, to reverse the electron density. A colorimetric assay was used to quantify cytotoxicity, and in vitro inhibition assays were performed on 3 different blood stages (ring, trophozoite, and schizonts) of P. falciparum 3D7 and the ring/mixed stage of D6 strain after synchronization. The in vitro cytotoxicity analysis showed that 2 new SKM13 derivatives reduced the cytotoxicity of the SKM13 template. SKM13 maintained the IC50 at the ring and trophozoite stages but not at the schizont stage. The IC50 values for both the trophozoite stage of P. falciparum 3D7 and ring/mixed stages of D6 demonstrated that 2 SKM13 derivatives had decreased antimalarial efficacy, particularly for the SKM13-F derivative. SKM13 may be comparably effective in ring and trophozoite, and electron-donating groups (-OMe) may be better maintain the antimalarial activity than electron-withdrawing groups (-F) in SKM13 modification.

Ultrastructure of Fertilized Egg Envelope in the Tomato Clown Anemonefish, Amphiprion freatus (Pomacentridae : Marine Teleostei) (해산 경골어류 자리 돔과, Tomato Clown Anemonefish (Amphiprion frenatus)의 수정란 난막 미세구조)

  • Kim, Dong-Heui;Reu, Dong-Suck;Deung, Young-Kun
    • Applied Microscopy
    • /
    • v.28 no.3
    • /
    • pp.273-282
    • /
    • 1998
  • Ultrastructure of fertilized egg envelope in the tomato clown anemonefish (Amphiprion freatus) was examined by mean of light, scanning and transmission electron microscopies. The fertilized egg of tomato clown anemonefish was of non-transparent, ellipsoidal, adhesive and non-floted type, and there were numerous oil droplets in the yolk sac and adhesive filaments in the area of the animal pole. The outer surface of egg envelope was smooth. The fertilized egg envelope consisted of two distinct layers; a non-adhesive outer electron-dense layer and an inner layer, consisting of five horizontal low electron-dense lamellae alternating with the middle electron dense interlamellae.

  • PDF

Current Status of Automatic Serial Sections for 3D Electron Microscopy

  • Choi, Hyosun;Jung, Min Kyo;Mun, Ji Young
    • Applied Microscopy
    • /
    • v.47 no.1
    • /
    • pp.3-7
    • /
    • 2017
  • The automatic equipment for three-dimensional electron microscopy (3DEM) can acquire serial sections of a large sample in a relatively short time, and is especially suitable for the connectomics, which is a field related to understanding the brain structure as a whole. As many results obtained through 3DEM using automatic serial sections have been published in the field of brain research, many researchers continue to apply this technique to various samples. We reviewed the equipment for automatic serial sectioning, the block preparation method, the limitations of 3DEM, and future directions.

Study on Energy Distribution of the 6 MeV Electron Beam using Gaussian Approximation (가우시안 근사를 이용한 6 MeV 전자선의 에너지분포에 관한 연구)

  • Lee, Jeong-Ok;Kim, Seung-Kon
    • Journal of radiological science and technology
    • /
    • v.22 no.2
    • /
    • pp.53-56
    • /
    • 1999
  • A Gaussian distribution was parametrized for the initial distribution of the electron beam emitted from a 6MeV medical linear accelerator. A percent depth dose was measured in a water phantom and the corresponding Monte Carlo calculations were performed starting from a Gaussian distribution for a range of standard deviations, ${\sigma}=0.1$, 0.15, 0.2, 0.25, and 0.3 with being the mean value for the Incident beam energy. When measurement and calculation were compared, the calculation with the Gaussian distribution for ${\sigma}=0.25$ turned out to agree best with the measurement. The results from the present work can be utilized as input energy data in planning an electron beam therapy with a Monte Carlo calculation.

  • PDF

Structural Studies of Respirasome by Cryo-Electron Microscopy

  • Jeon, Tae Jin;Kim, Ho Min;Ryu, Seong Eon
    • Applied Microscopy
    • /
    • v.48 no.4
    • /
    • pp.81-86
    • /
    • 2018
  • The respiratory chain complex forms a supercomplex (SC) in the inner mitochondrial membrane. This complex facilitates the process of electron transfer to produce the proton gradient used to synthesize ATP. Understanding the precise structure of the SC is considered an important challenge. However, it has not yet been reported. The development of a Cryo-electron microscopy (EM) technique provides an effective way to obtain high-resolution micrographs to determine the high-resolution three-dimensional structure of biomolecules. In this brief review, the currently reported Cryo-EM structures of the mammalian respirasome have been described in order to establish a direction for further research in the respiratory system.