• Title/Summary/Keyword: Medical device interface

Search Result 58, Processing Time 0.025 seconds

Point-of-care Testing Device Interface in Hospital Information System Standard Connectivity - Using of case ASTM protocol of ABGA application POCT1-A2 - (현장형 임상검사장비와 병원정보시스템의 접속표준 - ASTM protocol을 사용하는 ABGA의 POCT1-A2적용사례 중심으로 -)

  • Kim, Seon-Chil
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.10 no.2
    • /
    • pp.33-37
    • /
    • 2008
  • To keep the online medical records available to anyone without constraint of time and space, introducing EMR (Electronic medical record), which is a clinical support management system. The purpose of this study is to develop interface standard of clinical test device. Integration and sharing of medical information is faced with enormous obstacles because medical organizations and associated companies are separately developing the interface. I hope that multi-function management system with workstation concept is operated to efficiently transmit clinical device result data based on this study. Transfer of precise medical result data available for decision making will improve quality of health care service.

  • PDF

Summative Usability Assessment of Software for Ventilator Central Monitoring System (인공호흡기 중앙감시시스템 소프트웨어의 사용적합성 총괄평가)

  • Ji-Yong Chung;You Rim Kim;Wonseuk Jang
    • Journal of Biomedical Engineering Research
    • /
    • v.44 no.6
    • /
    • pp.363-376
    • /
    • 2023
  • According to the COVID-19, development of various medical software based on IoT(Internet of Things) was accelerated. Especially, interest in a central software system that can remotely monitor and control ventilators is increasing to solve problems related to the continuous increase in severe COVID-19 patients. Since medical device software is closely related to human life, this study aims to develop central monitoring system that can remotely monitor and control multiple ventilators in compliance with medical device software development standards and to verify performance of system. In addition, to ensure the safety and reliability of this central monitoring system, this study also specifies risk management requirements that can identify hazardous situations and evaluate potential hazards and confirms the implementation of cybersecurity to protect against potential cyber threats, which can have serious consequences for patient safety. As a result, we obtained medical device software manufacturing certificates from MFDS(Ministry of Food and Drug Safety) through technical documents about performance verification, risk management and cybersecurity application.The purpose of this study is to conduct a usability assessment to ensure that ergonomic design has been applied so that the ventilator central monitoring system can improve user satisfaction, efficiency, and safety. The rapid spread of COVID-19, which began in 2019, caused significant damage global medical system. In this situation, the need for a system to monitor multiple patients with ventilators was highlighted as a solution for various problems. Since medical device software is closely related to human life, ensuring their safety and satisfaction is important before their actual deployment in the field. In this study, a total of 21 participants consisting of respiratory staffs conducted usability test according to the use scenarios in the simulated use environment. Nine use scenarios were conducted to derive an average task success rate and opinions on user interface were collected through five-point Likert scale satisfaction evaluation and questionnaire. Participants conducted a total of nine use scenario tasks with an average success rate of 93% and five-point Likert scale satisfaction survey showed a high satisfaction result of 4.7 points on average. Users evaluated that the device would be useful for effectively managing multiple patients with ventilators. However, improvements are required for interfaces associated with task that do not exceed the threshold for task success rate. In addition, even medical devices with sufficient safety and efficiency cannot guarantee absolute safety, so it is suggested to continuously evaluate user feedback even after introducing them to the actual site.

Study on Radiation Limit of ISM Equipment for Protecting Radio Device (무선기기 보호를 위한 ISM 기기의 방사 한계치에 관한 연구)

  • Shim, Yong-Sup;Lee, Il-Kyoo;Hong, Seon-Eui
    • Journal of Satellite, Information and Communications
    • /
    • v.6 no.2
    • /
    • pp.10-14
    • /
    • 2011
  • This paper suggests the method to calculate radiation limit of ISM(Industrial Scientific Medical) equipment in order to protect radio device in the situation that ISM equipment and radio device are operated in near distance. The factor for correction and protection ratio which is need for protecting radio device were considered to calculate radiation limit of ISM equipment. Also, the scenario which is required to limit radiation power of ISM equipment was referred and the S/W for calculation of radiation limit was developed by using GUI(Graphical User Interface) on Matlab. The suggested method for calculation of radiation limit of ISM equipment will be used to protect radio device from ISM equipment.

Waveform Biosignal Interface based on International Standard MEER (MFER 표준을 적용한 생체신호정보 공유시스템 개발)

  • Cho, Hune;Kim, Seon-Chil
    • Journal of Biomedical Engineering Research
    • /
    • v.29 no.2
    • /
    • pp.164-171
    • /
    • 2008
  • Recently, many of hospitals have hurried to computerize the resulting data from medical devices, in order to introduce Electric Medical Record(EMR). In terms of the linkage between medical devices and hospital information systems, however, many difficulties have arisen due to some reasons such as the variety of prescription input, the format difference of the resulting data sheet, and the interface difference between medical devices from different companies. To solve these problems, many researches on standardization of the resulting data of medical devices have been performed. In this study, the linkage between hospital information systems and resulting datum in Electrocardiogram(ECG) generating biosignal waveform was tested by applying Medical waveform Format Encoding Rules(MFER) Version 1.02, which has more advantages than existing global standard. MFER viewer, in addition, was made to display the resulting data on a screen. The MFER viewer was tested and compared to the existing Scalable Vector Graphics (SVG) Viewer. The results showed that this method is more effective in the interface the data storage and application, because of simplicity and easiness in data applications. And the results show that the MFER is convenience and effective for physician. It is considered that the role of MFER as the interface in biosignal waveform including Electrocardiogram medical devices would expand in the near future.

Researches of the Real-time Medical Imaging Precessing Board using ASIC architecture (ASIC을 이용한 고속의료영상처리보드의 개발을 위한 기초연구)

  • Seo, J.H.;Park, H.M.;Ha, T.H.;Nam, S.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1998 no.11
    • /
    • pp.299-300
    • /
    • 1998
  • Recently the development of medical modality like as MRI, 3D US, DR etc is very active. Therefore it is more required not only the enhancement of quality in medical service but the improvement of medical system based on quantization, minimization, and optimization of high speed. Especially, as the changing into the digital modality system, it gets to start using ASIC(Application Specific Integrated Circuit) to realize one board system. It requires the implementation of hardware debugging and effective speedy algorithm with more speed and accuracy in order to support and replace existing device. If objected image could be linked to high speed process board with special interface and pre-processed using FPGA, it can be used in real time image processing and protocol of HIS(Hospital Information System). This study can support the basic circuit design of medical image board which is able to realize image processing basically using digitalized medical image, and to interface between existing device and image board containing image processing algorithm.

  • PDF

Development of Head Mounted Display Interface System for Controlling Wireless Capsule Endoscope (무선 캡슐내시경 조종을 위한 머리부착형 디스플레이 인터페이스 시스템의 개발)

  • Young-Eun, Hwang;Young-Don, Son
    • Journal of Biomedical Engineering Research
    • /
    • v.43 no.6
    • /
    • pp.417-423
    • /
    • 2022
  • The present study proposed a new interface system for capsule endoscopy by using head mounted display (HMD) device, which can control the orientation of the capsule endoscope with electromagnetic actuator (EMA) system. The orientation information of the HMD user was detected by the gyroscope sensor built into the device and then calculated to as an angle increment using Unity Engine compiler. The measured angle changes from the HMD were converted to the current values of the corresponding coils to be changed in the EMA system. Two experiments were designed to measure the accuracy and the intuitiveness of the HMD interface system. In the angle accuracy measurement, the capsule endoscope driven by HMD interface system showed the averaged errors of 0.68 degrees horizontally and 1.001 degrees vertically for given test angles. In the intuitiveness measurement, HMD interface system showed 1.33 times faster manipulation speed rather than the joystick interface system. In this respect, the HMD interface system for capsule endoscopy was expected to improve the overall diagnostic environment while maintaining comfort of patients and clinicians.

Development of Numerical Model of Electrode for Radiofrequency Catheter Ablation Considering Saline Irrigation and Temperature-controlled Radiofrequency System (온도 조절형 고주파 시스템 및 식염수 분사를 고려한 전극도자절제술용 전극의 수치 모델 개발)

  • Ahn, Jin-Woo;Kim, Young-Jin;Lee, Seung-A;Jung, Ha-Chul;Kim, Kyung-Ah;Cha, Eun-Jong;Moon, Jin-Hee
    • Journal of Biomedical Engineering Research
    • /
    • v.38 no.6
    • /
    • pp.285-290
    • /
    • 2017
  • Radiofrequency catheter ablation is the interventional therapy that be employed to eliminate cardiac tissue caused by arrhythmias. During radiofrequency catheter ablation, The thrombus can occur at electrode tip if the temperature of tissue and electrode is excess $100^{\circ}C$. To prevent this phenomenon, we investigated numerical model of electrode for radiofrequency catheter ablation considering saline irrigation and temperature-controlled radiofrequency system. The numerical model is based on coupled electric-thermal-flow problem and solved by COMSOL Multiphysics software. The results of the models show that the dimensions of the thermal lesion are increased if the flow rate of the saline irrigation and the set temperature are increased. The surface width characterized to determine the thermal lesion isn't need to measure in temperature-controlled radiofrequency system due to convective heat transfer by saline irrigation at tissue-electrode interface.

A Research for Interface Based on EMG Pattern Combinations of Commercial Gesture Controller (상용 제스처 컨트롤러의 근전도 패턴 조합에 따른 인터페이스 연구)

  • Kim, Ki-Chang;Kang, Min-Sung;Ji, Chang-Uk;Ha, Ji-Woo;Sun, Dong-Ik;Xue, Gang;Shin, Kyoo-Sik
    • Journal of Engineering Education Research
    • /
    • v.19 no.1
    • /
    • pp.31-36
    • /
    • 2016
  • These days, ICT-related products are pouring out due to development of mobile technology and increase of smart phones. Among the ICT-related products, wearable devices are being spotlighted with the advent of hyper-connected society. In this paper, a body-attached type wearable device using EMG(electromyography) sensors is studied. The research field of EMG sensors is divided into two parts. One is medical area and another is control device area. This study corresponds to the latter that is a method of transmitting user's manipulation intention to robots, games or computers through the measurement of EMG. We used commercial device MYO developed by Thalmic Labs in Canada and matched up EMG of arm muscles with gesture controller. In the experiment part, first of all, various arm motions for controlling devices are defined. Finally, we drew several distinguishing kinds of motions through analysis of the EMG signals and substituted a joystick with the motions.

Smart Home Healthcare Device based on Ubiquitous Communication

  • Kim, Keun-Young;Cha, Joo-Hun;Park, Mig-Non
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.2235-2239
    • /
    • 2003
  • The aim of this research is to study and develop enabling technologies for home healthcare device with ubiquitous network. The motivation of this paper is to enable healthcare in home, to development the device for smart home health care. To achieve the aim, we must develop the prototype platform based on home gateways, distributed context user interface based on UPnP and support for information sharing with high speed power line communication and mobile infra-structures. And IPv6 is the base technology of this platform. In this paper, we concern that physical health, mental health and medical emergencies is all of home healthcare. With the smart device, we evaluate the connectivity, automatic information extraction and private data exchange and event driven message. The result of this paper is demonstration of smart device for ubiquitous communication in a healthcare application such as patient monitoring device and several information services. In conclusion, home healthcare will support more healthy and easy living for a human.

  • PDF

Software Platform for Stability Assure of Sensor Network in u-Health Environment (유헬스 환경에서 센서네트워크의 안정성 보장을 위한 소프트웨어 플랫폼)

  • Jung, Min Woo;Cho, Jeonghun
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.7 no.5
    • /
    • pp.219-226
    • /
    • 2012
  • The rises of the life index quality together with the medical technology improvement lead to a longer life expectancy. Then a better health care program, especially for elderly, is needed. The common health problems facing those senior citizens are changed from acute diseases to chronic diseases, such as diabetes, hypertension. Then u-Health takes center stage in medical industry. Although u- Health medical device manufacturers have been improving their instruments, these instruments still rely on proprietary technologies without fixed platform. Even if the interface has been provided by the manufacturer, there is no widely-accepted uniform data model to access data of various u-Health devices. IEEE 11073 is a standard attempting to unify the interfaces of all medical devices. In this paper we have proposed a conversion software platform that assures interoperability among medical devices for ubiquitous sensor network. This module uses in order to develop a standard platform of medical system.