Experimental Study with Respect to Dose Characteristic of Glass Dosimeter for Low-Energy by Using Internal Detector of Piranha 657 (Piranha 657의 Internal Detector를 이용한 저에너지에서 유리선량계의 선량 특성에 관한 연구)

  • Son, Jin-Hyun;Min, Jung-Whan;Kim, Hyun-Soo;Lyu, Kwang-Yeul;Lim, Hyun-Soo;Kim, Jung-Min;Jeong, Hoi-Woun
    • Journal of radiological science and technology
    • /
    • v.35 no.2
    • /
    • pp.119-124
    • /
    • 2012
  • Recently, Glass Dosimeter (GD) with thermoluminescent Dosimeter (TLD) are comprehensively used to measure absorbed dose from diagnostic field to therapy field that means from low energy field to high energy field. However, such studies about dose characteristics of GD, such as reproducibility and energy dependency, are mostly results in high energy field. Because characteristic study for measurement devices of radiation dose and radiation detector is performed using 137Cs and 60Co which emit high energy radiations. Thus, this study was evaluated the linearity according to Piranha dose which measured by changing tube voltage (50kV, 80kV and 100kV which are low energy radiations), reproducibility and reproducibility according to delay time using GD. Measurement of radiation dose is performed using internal detector of Piranha 657 which is multi-function QA device (RTI Electronic, Sweden). Condition of measurement was 25mA, 0.02sec, 2.5mAs, SSD of 100 cm and exposure area with $10{\times}10cm^2$. As above method, GD was exposed to radiation. Sixty GDs were divided into three groups (50kV, 80kV, 100kV), then measured. In this study, GD was indicated the linearity in low energy field as high energy existing reported results. The reproducibility and reproducibility according to delay time were acceptable. In this study, we could know that GD can be used to not only measure the high energy field but also low energy field.

Development of Dose Planning System for Brachytherapy with High Dose Rate Using Ir-192 Source (고선량률 강내조사선원을 이용한 근접조사선량계획전산화 개발)

  • Choi Tae Jin;Yei Ji Won;Kim Jin Hee;Kim OK;Lee Ho Joon;Han Hyun Soo
    • Radiation Oncology Journal
    • /
    • v.20 no.3
    • /
    • pp.283-293
    • /
    • 2002
  • Purpose : A PC based brachytherapy planning system was developed to display dose distributions on simulation images by 2D isodose curve including the dose profiles, dose-volume histogram and 30 dose distributions. Materials and Methods : Brachytherapy dose planning software was developed especially for the Ir-192 source, which had been developed by KAERI as a substitute for the Co-60 source. The dose computation was achieved by searching for a pre-computed dose matrix which was tabulated as a function of radial and axial distance from a source. In the computation process, the effects of the tissue scattering correction factor and anisotropic dose distributions were included. The computed dose distributions were displayed in 2D film image including the profile dose, 3D isodose curves with wire frame forms and dosevolume histogram. Results : The brachytherapy dose plan was initiated by obtaining source positions on the principal plane of the source axis. The dose distributions in tissue were computed on a $200\times200\;(mm^2)$ plane on which the source axis was located at the center of the plane. The point doses along the longitudinal axis of the source were $4.5\~9.0\%$ smaller than those on the radial axis of the plane, due to the anisotropy created by the cylindrical shape of the source. When compared to manual calculation, the point doses showed $1\~5\%$ discrepancies from the benchmarking plan. The 2D dose distributions of different planes were matched to the same administered isodose level in order to analyze the shape of the optimized dose level. The accumulated dose-volume histogram, displayed as a function of the percentage volume of administered minimum dose level, was used to guide the volume analysis. Conclusion : This study evaluated the developed computerized dose planning system of brachytherapy. The dose distribution was displayed on the coronal, sagittal and axial planes with the dose histogram. The accumulated DVH and 3D dose distributions provided by the developed system may be useful tools for dose analysis in comparison with orthogonal dose planning.

Understanding the Response Characteristics of X-ray Verification Film (X-선 Verification 필름의 반응 특성에 관한 연구)

  • Yeo Inhwan;Seong Jinsil;Chu Sung Sil;Kim Gwi Eon;Suh Chang Ok;Burch Sandra E.;Wang Chris K.
    • Radiation Oncology Journal
    • /
    • v.16 no.4
    • /
    • pp.505-515
    • /
    • 1998
  • Purpose : This study is intended to understand the sensitometric characteristics and the emulsion properties of the commercially available CEA TVS film in comparison with the Kodak X-Omat V film. Materials and Methods : For this purpose, we have formulated an analytic expression of the characteristic curves for x-ray film exposed to mixed radiation of electrons, photons, and visible light. This mathematical expression was developed based on reaction-rate and target-hit theories. Unlike previous expressions. it relates optical density to emulsion properties such as grain size and silver bromide content We have also developed a quantity which characterizes the film response to visible light relative to that to photons and electrons. This quantity could be expressed as a function of grain area. Thus, we have developed mathematical expressions and quantities with which the emulsion properties of the films can be revealed based on the sensitometric characteristics. Demonstrating the use of this analytical study, we exposed CEA and Kodak verification films to the mixed radiation of electrons, photons, and visible light, and interpreted the experimental results accordingly. Results : We have demonstrated that: (1) the saturation density increases as the silver bromide content increases, (2) the time required to reach the threshold dose (to which the film begins to respond) when films are exposed to visible light decreases as the grain size increases, and (3) the CEA film contains more silver bromide. whereas the Kodak film contains larger grains. These findings were supported by the data provided by the manufacturers afterward. Conclusion : This study presented an analytical and experimental basis for understanding the response of X-ray film with respect to the emulsion properties.

  • PDF

Association between Perceived Susceptibility to Fine Dust Exposure and Wearing Masks, Attitude toward Respiratory Disease Prevention Education in Farmers (농업인의 미세먼지 노출에 대한 인지된 감수성과 마스크 착용 및 호흡기질환 예방교육 참여 태도와의 연관성)

  • Jung, HyeJeong;Lee, YunJin;Lee, SooYeon;Han, JiYoung;Kim, YangWoo;Lee, Soo-Jin
    • Journal of agricultural medicine and community health
    • /
    • v.46 no.2
    • /
    • pp.78-88
    • /
    • 2021
  • Objectives: This study aimed to investigate health risk awareness pertaining to fine dust exposure and the use of face masks in farmers, as well as their attitude toward education regarding fine dust-related respiratory disease prevention. Methods: In total, 295 farmers were interviewed in a survey using a structured questionnaire to obtain data on general characteristics, farming-related characteristics, health risk awareness pertaining to fine dust exposure, attitude toward education on fine dust-related respiratory disease prevention and the use of face masks. This study was analyzed the correlation between the perceived susceptibility to fine dust exposure and willingness to participate in education on fine dust-related respiratory disease prevention. Results: The mean score for perceived susceptibility to fine dust exposure was 3.8 (out of 5), and the participants were highly willing to receive education on fine dust-related respiratory disease prevention. In Multiple response analysis of reactions to exposure to fine dust generated during work, 221 participants responded that they practiced at least one preventive action; participants gave a positive response to "wearing masks" (56.1%), "personal hygiene, such as hand washing." (52.9%). In terms of education methods, 94 (33.6%) participants preferred to learn online or via text messages. Conclusions: The significant correlation between the perceived susceptibility to fine dust exposure and willingness to participate in education on fine dust-related respiratory disease prevention shows the importance of promoting education on prevention. The results of this study can help understand as reference for education on fine dust-related respiratory disease prevention.

Research on Radiation Shielding Film for Replacement of Lead(Pb) through Roll-to-Roll Sputtering Deposition (롤투롤 스퍼터링 증착을 통한 납(Pb) 대체용 방사선 차폐필름 개발)

  • Sung-Hun Kim;Jung-Sup Byun;Young-Bin Ji
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.3
    • /
    • pp.441-447
    • /
    • 2023
  • Lead(Pb), which is currently mainly used for shielding purposes in the medical radiation, has excellent radiation shielding functions, but is continuously exposed to radiation directly or indirectly due to the harmfulness of lead itself to the human body and the inconvenience caused by its heavy weight. Research on shielding materials that are human-friendly, lightweight, and convenient to use that can block risks and replace lead is continuously being conducted. In this study, based on the commonly used polyethylene terephthalate (PET) film and the fabric material used in actual radiation protective clothing, a multi-layer thin film was realized through sputtering and vacuum deposition of bismuth, tungsten, and tin, which are metal materials that can shield radiation. Thus, a shielding film was produced and its applicability as a radiation shielding material was evaluated. The radiation shielding film was manufactured by establishing the optimized conditions for each shielding material while controlling the applied voltage, roll driving speed, and gas supply amount to manufacture the shielding film. The adhesion between the parent material and the shielding metal thin film was confirmed by Cross-cut 100/100, and the stability of the thin film was confirmed through a hot water test for 1 hour to measure the change of the thin film over time. The shielding performance of the finally realized shielding film was measured by the Korea association for radiation application (KARA), and the test conditions (inverse wide beam, tube voltage 50 kV, half layer 1.828 mmAl) were set to obtain an attenuation ratio of 16.4 (initial value 0.300 mGy/s, measured value 0.018 mGy/s) and damping ratio 4.31 (initial value 0.300 mGy/s, measured value 0.069 mGy/s) were obtained. by securing process efficiency for future commercialization, light and shielding films and fabrics were used to lay the foundation for the application of films to radiation protective clothing or construction materials with shielding functions.

Middle School Science Teacher's Perceptions of Science-Related Careers and Career Education (과학 관련 직업과 진로 교육에 대한 중학교 과학 교사의 인식)

  • Nayoon Song;Sunyoung Park;Taehee Noh
    • Journal of The Korean Association For Science Education
    • /
    • v.44 no.2
    • /
    • pp.167-178
    • /
    • 2024
  • In this study, we investigated the perceptions of science-related careers and career education among middle school science teachers. Sixty-four science teachers experienced in teaching unit 7 in the first year of middle school participated. The results of the study revealed that not only careers in science but also careers with science were found to be quite high when teachers were asked to provide examples of science-related careers. Jobs related to research/engineering, which are careers in science, comprised the highest proportion of teachers' answers, followed by jobs related to education/law/social welfare/police/firefighting/military, and health/medical, which are careers with science. However, the proportion of jobs mentioned related to installation/maintenance/production was extremely low. The skills required for science-related careers were mainly perceived to consist of tools for working and ways of working. The number of skills classified under living in the world was perceived to be extremely low across most careers, irrespective of career type. Most teachers only taught unit 7 for two to four sessions and devoted little time to science-related career education, even in general science classes. In the free semester system, a significant number of teachers responded that they provide science-related career education for more than 8 hours. Teachers mainly utilize lecture, discussion/debate, and self-study activities. Meanwhile, in the free semester system, the resource-based learning method was utilized at a high proportion compared to other class situations. Teachers generally made much use of media materials, with the use of textbooks and teacher guides found to be lower than expected. There were also cases of using materials supported by science museums or the Ministry of Education. Teachers preferred to implementing student-centered classes and utilizing various teaching and learning methods. Based on the above research results, discussions were proposed to improve teachers' perceptions of science-related careers and career education.

Results of Radiation Therapy and Extrafascial Hysterectomy in Bulky Stage IB, IIA-B Carcinoma of the Uterine Cervix (종괴가 큰 병기 IB, IIA-B 자궁경부암에서 방사선치료와 Extrafascial Hysterectomy의 결과)

  • Kim Jin Hee;Lee Ho Jun;Choi Tae Jin;Do Cha Soon;Lee Tae Sung;Kim Ok Bae
    • Radiation Oncology Journal
    • /
    • v.17 no.1
    • /
    • pp.23-29
    • /
    • 1999
  • Purpose : To evaluate the efficacy of radiation therapy and extrafascial hysterectomy in bulky stage IB, IIA-B uterine cervix cancers. Methods and Materials : Twenty four patients with bulky stage IB and IIA-B carcinoma of the uterine cervix were treated with extrafascial hysterectomy following radiation therapy due to doubts of residual disease at Department of therapeutic radiology, Keimyung University, Dongsan Hospital, from April 1986 to December 1997 According to FIGO staging system, there were 7 patients with stage IB, 9 patients with IIA and 8 patients with IIB stage whose median age was 45. Pathologic distribution showed 16 patients with squamous cell carcinoma and 8 patients with adenocarcinoma. Seven patients had tumors that are less than 5cm in size and 17 patients had tumors with larger than 5cm. The mean interval between radiation therapy and extrafascial hysterectomy was 57 days. The radiation therapy consisted of external irradition to the whole pelvis (180 cGy/fraction, mean 4100 cGy) and parametrial boost (for a mean total dose of 5000 cGy) with midline shield (4H 10 cm), followed by intracavitary irradiation up to 7500 cGy to point A (maximum 8500 cGy). The maximum follow up duration was 107 months and mean follow up duration was 42 months. Results :Ten out of 24 patients (41.7%) had residual disease found at the time of extrafascial hysterectomies. Five year overall survival rate (5Y OSR) and five year disease free survival rate (5Y DFSR) were 63.6% and 62.5% respectively. Five year overall survival rate for stage IB and IIA was 71.4% and 50% for stage IIB. There was a significant difference in 5Y OSR and 5Y DFSR between patients with and those without residual disease (negative vs positive, 83.3% vs. 40% (P=0.01), 83.3% vs 36% (P=0.01) respectively). There was a notable tendency of better survival with adenocarcinoma than with squamous cell carcinoma (adenocarcinoma vs squamous cell carcinoma, 85.7% vs. 53.3% (P=0.1), 85.7% vs. 50.9% (P=0.1) of 5Y OSR and 5Y DFS respectivey). Total dose to A point did not make a significant difference in survival rate or the existence of residual lesion (< 7500 cGy, ${\geq}$ 7500 cOy). It was also noted that significantly more frequent local failures have occurred in patients with positive residual disease compared with negative residual disease (5/10 vs. 0/14, p=0.003), There was no death related to the treatment. Conclusion : There was no improvement of residual disease and to the overall survival rate in spite of increased total dose to point A. We conclude that there is a possible beneficial effect of radiation therapy followed by extrafaseial hysterectomy in survival for adenocarcinoma of bulky stage IB and IIA-B uterine cervix. We need to confirm this with longer follow up and with large number of patients.

  • PDF

Inhomogeneity correction in on-line dosimetry using transmission dose (투과선량을 이용한 온라인 선량측정에서 불균질조직에 대한 선량 보정)

  • Wu, Hong-Gyun;Huh, Soon-Nyung;Lee, Hyoung-Koo;Ha, Sung-Whan
    • Journal of Radiation Protection and Research
    • /
    • v.23 no.3
    • /
    • pp.139-147
    • /
    • 1998
  • Purpose: Tissue inhomogeneity such as lung affects tumor dose as well as transmission dose in new concept of on-line dosimetry which estimates tumor dose from transmission dose using the new algorithm. This study was carried out to confirm accuracy of correction by tissue density in tumor dose estimation utilizing transmission dose. Methods: Cork phantom (CP, density $0.202\;gm/cm^3$) having similar density with lung parenchyme and polystyrene phantom (PP, density $1.040\;gm/cm^3$) having similar density with soft tissue were used. Dose measurement was carried out under condition simulating human chest. On simulating AP-PA irradiation, PPs with 3 cm thickness were placed above and below CP, which had thickness of 5, 10, and 20 cm. On simulating lateral irradiation, 6 cm thickness of PP was placed between two 10 cm thickness CPs additional 3 cm thick PP was placed to both lateral sides. 4, 6, and 10 MV x-ray were used. Field size was in the range of $3{\times}3$ cm through $20{\times}20$ cm, and phantom-chamber distance (PCD) was 10 to 50 cm. Above result was compared with another sets of data with equivalent thickness of PP which was corrected by density. Result: When transmission dose of PP was compared with equivalent thickness of CP which was corrected with density, the average error was 0.18 (${\pm}0.27$) % for 4 MV, 0.10 (${\pm}0.43$) % for 6 MV, and 0.33 (${\pm}0.30$) % for 10 MV with CP having thickness of 5 cm. When CP was 10 cm thick, the error was 0.23 (${\pm}0.73$) %, 0.05 (${\pm}0.57$) %, and 0.04 (${\pm}0.40$) %, while for 20 cm, error was 0.55 (${\pm}0.36$) %, 0.34 (${\pm}0.27$) %, and 0.34 (${\pm}0.18$) % for corresponding energy. With lateral irradiation model, difference was 1.15 (${\pm}1.86$) %, 0.90 (${\pm}1.43$) %, and 0.86 (${\pm}1.01$) % for corresponding energy. Relatively large difference was found in case of PCD having value of 10 cm. Omitting PCD with 10 cm, the difference was reduced to 0.47 (${\pm}$1.17) %, 0.42 (${\pm}$0.96) %, and 0.55 (${\pm}$0.77) % for corresponding energy. Conclusion When tissue inhomogeneity such as lung is in tract of x-ray beam, tumor dose could be calculated from transmission dose after correction utilizing tissue density.

  • PDF

Analysis of the Eyeglasses Supply System for Ametropes in ROK Military (한국군 비정시자용 안경의 보급체계 분석)

  • Jin, Yong-Gab;Koo, Bon-Yeop;Lee, Woo-Chul;Yoon, Moon-Soo;Park, Jin-Tae;Lee, Hang-Seok;Lee, Kyo-Eun;Leem, Hyun-Sung;Jang, Jae-Young;Mah, Ki-Choong
    • The Korean Journal of Vision Science
    • /
    • v.20 no.4
    • /
    • pp.579-588
    • /
    • 2018
  • Purpose : To analyze the eyeglasses supply system for ametropic soldiers in ROK military. Methods : We investigated and analyzed the supply system of eyeglasses for the ametropic soldiers provided by the Korean military. The refractive powers and corrected visual acuity were measured for 37 ametropic soldiers who wear insert glasses for ballistic protective and gas-masks supplied by the military based on their habitual prescriptions. Full correction of refractive error was prescribed for subjects having less than 1.0 of distance visual acuity, and comparison was held for inspecting the changes in corrected visual acuity. Suggestions were provided for solving the issues regarding current supplying system, and this study investigated the applicabilities for utilizing professional optometric manpower. Results : The new glasses supplied by army for ametropic soldiers were duplicated from the glasses they worn when entering the army. The spherical equivalent refractive powers of the conventional, ballistic protective and gas-mask insert glasses supplied for 37 ametropic soldiers were $-3.47{\pm}1.69D$, $-3.52{\pm}1.66D$ and $-3.55{\pm}1.63D$, respectively, and the spherical equivalent refractive power of full corrected glasses was $-3.79{\pm}1.66D$, which showed a significant difference(p<0.05). The distant corrected visual acuity measured at high and low contrast(logMAR) of conventional, ballistic protective and gas-mask insert glasses were $0.06{\pm}0.80$, $0.21{\pm}0.82$, $0.15{\pm}0.74$, $0.34{\pm}0.89$, $0.10{\pm}0.70$ and $0.22{\pm}0.27$, respectively, while the corrected visual acuity by full corrected glasses were increased to $0.02{\pm}1.05$, $0.10{\pm}0.07$, $0.09{\pm}0.92$, $0.26{\pm}0.10$, $0.04{\pm}1.00$ and $0.19{\pm}1.00$, respectively. There was a significant difference(p<0.05) except for the case of the low contrast corrected visual acuity of the conventional and gas-mask insert glasses. The procedure for ordering, dispensing, and supplying military glasses consists of 5 steps, and it was found that approximately two weeks or more are required to supply from the initial examination. Conclusion : The procedure of supplying the military glasses showed three issues: 1) a lack of refraction for prescription system, 2) relatively long length of time required for supplying the glasses, 3) an inaccurate power of supplied glasses. In order to solve those issues, in the short term, education is necessarily required for soldiers on the measurement of the refractive powers, and in the near future, further standard procedures for prescription of glasses as well as the securement of optometric manpower are expected.