• Title/Summary/Keyword: Medical Device Risk Management

Search Result 36, Processing Time 0.029 seconds

A Study on the Application of Risk Management for Medical Device Software Test (의료기기 소프트웨어 테스트 위험관리 적용 방안 연구)

  • Kim, S.H.;Lee, jong-rok;Jeong, Dong-Hun;Park, Hui-Byeong
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2012.10a
    • /
    • pp.495-497
    • /
    • 2012
  • Development of application risk management for medical device software test. First, Through questionnaires, Medical device manufacturers, Analysis of software validation and risk management status. Second, Analyzed by comparing the difference between black box testing and white box testing. Third, After analyzing the potential for software analysis tools using code derived factors were quantified, Finally, Medical device risk management process so that it can be applied to build the framework by FMEA(Failure Mode and Effect Analysis) technique. Through this Difficult to build software validation and risk management processes for manufacturers to take advantage of support in medical device GMP(Good Manufacture Practice).

  • PDF

ISO14971:2019 Detailed Analysis and Periodic Safety Update Report Establishment Method for the Single Use Medical Device - Focusing on Medical Device Regulation 2017/745 requirements (일회용 의료기기에 적용을 위한 ISO 14971:2019 분석과 Periodic Safety Update Report 작성 방법 - Medical Device Regulation 2017/745 요구사항 중심으로)

  • Sang Min, Park;Gyu Ha, Ryu
    • Journal of Biomedical Engineering Research
    • /
    • v.44 no.1
    • /
    • pp.1-10
    • /
    • 2023
  • With the announcement of MEDICAL DEVICE REGULATION 2017/745 (MDR) on April 5 2017, medical device manufacturers shall apply ISO 14971:2019 (3rd) revised in December 2019. However, there is not much related information and guidance available to medical device manufacturers, especially single use medical device. Risk management process basically follow 5 steps which are Risk Analysis, Risk Evaluation, Risk Control, Evaluation of overall residual risk and post-production activities. The purpose of this study is to provide a guidance of from risk analysis with Failure Mode and Effects Analysis (FMEA) table to overall residual risk evaluation for the single use medical device and to reflect it in a Periodic Safety Update Reports (PSUR) to satisfy with MDR requirements with single use medical device which are widely used and manufactured FDA class 2 or CE class IIb as examples. For this study, single use medical device manufacturer can adopt ISO 14971:2019 in accordance with MDR requirements and it can be extended to the PSUR. But there are still limitations to adopt to the all-single use medical device especially high class, private device and implantable device. So, Competent Authority (CA) shall publish more guidance for the single use medical device.

Reliability Management of Mechanical Ventilator in Intensive Care Unit Using FMEA Based on ISO14971 (ISO14971 기반 FMEA를 이용한 중환자실내 인공호흡기 신뢰성 관리)

  • Hyun Joon, Kim;Won Kyu, Kim;Tae Jong, Kim;Gee Young, Suh
    • Journal of Biomedical Engineering Research
    • /
    • v.44 no.1
    • /
    • pp.19-24
    • /
    • 2023
  • Due to the spread of COVID-19, many patients with severe respiratory diseases have occurred worldwide, and accordingly, the use of mechanical ventilators has exploded. However, hospitals do not have systematic risk management, and the Medical Device Regulation also provides medical device risk management standards for manufacturers, but does not apply to devices in use. In this paper, we applied the Failure Mode Effects Analysis (FMEA) risk analysis technique based on the International Standard ISO 14971 (Medical Devices-Application of risk management to medical devices) for 85 mechanical ventilators of a specific model in use in hospitals. Failure modes and effects of each parts were investigated, and risk priority was derived through multiplication of each score by preparing criteria for severity, occurrence, and detection for each failure mode. As a result, it was confirmed that the microprocessor-based Patient Unit/Monitoring board in charge of monitoring scored the highest score with 36 points, and that reliability management is possible through systematic risk management according to priority.

Establish Selection Process of Performance Management Medical Devices and Test items Based on Risk Management (위험관리기반의 성능관리 의료기기 선정 절차 수립 및 시험 항목 도출)

  • Park, Ho Joon;Jang, Joong Soon
    • Journal of Biomedical Engineering Research
    • /
    • v.40 no.1
    • /
    • pp.20-31
    • /
    • 2019
  • Medical device performance management is an activity that allows a device to be safely used and maintained even after it is put on the market. The purpose of this study is to provide procedures and criteria for selection of medical device items that should manage the safety and performance among medical devices in hospital. Investigate the performance management status of medical devices in hospitals and identify the performance management status by domestic and advanced regulatory agencies. Provides selection procedures and test methods for medical devices subject to performance management in hospitals based on medical device risk management and reliability. In addition, a case study on drug infusion pumps was conducted.

Software Risk Management and Cyber Security for Development of Integrated System Remotely Monitoring and Controlling Ventilators (인공호흡기 원격 통합 모니터링 및 제어 시스템 개발을 위한 소프트웨어 위험관리 및 사이버보안)

  • Ji-Yong Chung;You Rim Kim;Wonseuk Jang
    • Journal of Biomedical Engineering Research
    • /
    • v.44 no.2
    • /
    • pp.99-108
    • /
    • 2023
  • According to the COVID-19, development of various medical software based on IoT(Internet of Things) was accelerated. Especially, interest in a central software system that can remotely monitor and control ventilators is increasing to solve problems related to the continuous increase in severe COVID-19 patients. Since medical device software is closely related to human life, this study aims to develop central monitoring system that can remotely monitor and control multiple ventilators in compliance with medical device software development standards and to verify performance of system. In addition, to ensure the safety and reliability of this central monitoring system, this study also specifies risk management requirements that can identify hazardous situations and evaluate potential hazards and confirms the implementation of cybersecurity to protect against potential cyber threats, which can have serious consequences for patient safety. As a result, we obtained medical device software manufacturing certificates from MFDS(Ministry of Food and Drug Safety) through technical documents about performance verification, risk management and cybersecurity application.

Development Life Cycle-Based Association Analysis of Requirements for Risk Management of Medical Device Software (의료기기 소프트웨어 위험관리를 위한 개발생명주기 기반 위험관리 요구사항 연관성 분석)

  • Kim, DongYeop;Park, Ye-Seul;Lee, Jung-Won
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.6 no.12
    • /
    • pp.543-548
    • /
    • 2017
  • In recent years, the importance of the safety of medical device software has been emphasized because of the function and role of the software among components of the medical device, and because the operation of the medical device software is directly related to the life and safety of the user. To this end, various standards have been set up that provide activities that can effectively ensure the safety of medical devices and provide their respective requirements. The activities that standards provide to ensure the safety of medical device software are largely divided into the development life cycle of medical device software and the risk management process. These two activities should be concurrent with the development process, but there is a limitation that the risk management requirements to be performed at each stage of the medical device software development life cycle are not classified. As a result, developers must analyze the association of standards directly to develop risk management activities during the development of medical devices. Therefore, in this paper, we analyze the relationship between medical device software development life cycle and risk management process, and extract risk management requirement items. It enables efficient and systematic risk management during the development of medical device software by mapping the extracted risk management requirement items to the development life cycle based on the analyzed associations.

Application of Risk Management for Dental Implants Based on ISO 14971 (치과용 임플란트에 대한 ISO 14971 기반의 리스크관리)

  • Yoon, Ji-Hoon;Kim, Young-Jin;Jeon, Gye-Rok;Jeong, Chang-Mo
    • Journal of the Korean Society of Safety
    • /
    • v.27 no.2
    • /
    • pp.92-97
    • /
    • 2012
  • Risk management is the process that helps to identify hazards, analyze them, and then to create an action plan to avoid and mitigate these hazards. The main objective of risk management in product development and manufacturing is to provide safe and efficient products without spending too many resources. Medical device manufacturers also face enormous risks - regulatory, legal, and financial - based on their products and processes, and the concepts of risk management are particularly important because any single failure may result in serious damages to body or loss of life. In this regard, a set of guidelines for the application of risk management to medical devices has been issued by ISO and specified in the document ISO 14971 Medical devices - Application of risk management to medical devices. The main objective of this study is to investigate the application of risk management to dental implant development and manufacturing processes based on ISO 14971. A general risk management process is first introduced, and the application of ISO 14971 to dental implants is further investigated.

Comparative Study of ISO Standards for an Effective Implementation of the Domestic Medical Device GMP System (ISO 국제표준의 비교 연구를 통한 국내 의료기기 GMP 제도의 효과적인 운영 방안)

  • Jung, Young A;Kim, Young Jin
    • Journal of Korean Society for Quality Management
    • /
    • v.46 no.2
    • /
    • pp.211-224
    • /
    • 2018
  • Purpose: It can easily be understood that more rules and regulations need to be imposed on the medical device industry due to its impact on public health and hygiene. Domestic medical device manufacturers are thus required to comply with the requirements specified in the good manufacturing practice (GMP) system, and it is essential to abide by the international standards as well to sustain their global competitiveness. The main purpose of this study is to review the guidelines of the medical device GMP system in Korea and propose future directions for further enhancement of the GMP system. Methods: Specific requirements prescribed in international standards, such as ISO 9001:2015, ISO 13485:2016, ISO 14971:2012, and ISO 14155:2011, are analyzed and compared with the domestic GMP system. Results: It has been observed that the generic international standard related to quality management system, ISO 9001:2015, lays out the foundations for the development of quality management system relevant to medical device industry, ISO 13485:2003, with which the domestic GMP system is fully compatible. Further, several important aspects of risk management and clinical trials of medical devices are also recognized and included in the domestic medical device GMP system. Conclusion: Even though specific requirements of individual ISO standards are slightly different from each other, their overall structure and framework may contribute to the development and enhancement of globally competitive GMP system of the domestic medical device industry.

Summative Usability Assessment of Software for Ventilator Central Monitoring System (인공호흡기 중앙감시시스템 소프트웨어의 사용적합성 총괄평가)

  • Ji-Yong Chung;You Rim Kim;Wonseuk Jang
    • Journal of Biomedical Engineering Research
    • /
    • v.44 no.6
    • /
    • pp.363-376
    • /
    • 2023
  • According to the COVID-19, development of various medical software based on IoT(Internet of Things) was accelerated. Especially, interest in a central software system that can remotely monitor and control ventilators is increasing to solve problems related to the continuous increase in severe COVID-19 patients. Since medical device software is closely related to human life, this study aims to develop central monitoring system that can remotely monitor and control multiple ventilators in compliance with medical device software development standards and to verify performance of system. In addition, to ensure the safety and reliability of this central monitoring system, this study also specifies risk management requirements that can identify hazardous situations and evaluate potential hazards and confirms the implementation of cybersecurity to protect against potential cyber threats, which can have serious consequences for patient safety. As a result, we obtained medical device software manufacturing certificates from MFDS(Ministry of Food and Drug Safety) through technical documents about performance verification, risk management and cybersecurity application.The purpose of this study is to conduct a usability assessment to ensure that ergonomic design has been applied so that the ventilator central monitoring system can improve user satisfaction, efficiency, and safety. The rapid spread of COVID-19, which began in 2019, caused significant damage global medical system. In this situation, the need for a system to monitor multiple patients with ventilators was highlighted as a solution for various problems. Since medical device software is closely related to human life, ensuring their safety and satisfaction is important before their actual deployment in the field. In this study, a total of 21 participants consisting of respiratory staffs conducted usability test according to the use scenarios in the simulated use environment. Nine use scenarios were conducted to derive an average task success rate and opinions on user interface were collected through five-point Likert scale satisfaction evaluation and questionnaire. Participants conducted a total of nine use scenario tasks with an average success rate of 93% and five-point Likert scale satisfaction survey showed a high satisfaction result of 4.7 points on average. Users evaluated that the device would be useful for effectively managing multiple patients with ventilators. However, improvements are required for interfaces associated with task that do not exceed the threshold for task success rate. In addition, even medical devices with sufficient safety and efficiency cannot guarantee absolute safety, so it is suggested to continuously evaluate user feedback even after introducing them to the actual site.

A Study on Regulatory Law for Management System of Combined Medical Device (결합 의료기기 관리제도의 규제관련 법률에 관한 연구)

  • Choi, Yong Jun;Choi, Mi Lim;Lee, Jeong Chan;Jung, Yong Gyu
    • Journal of Service Research and Studies
    • /
    • v.4 no.2
    • /
    • pp.1-10
    • /
    • 2014
  • According to recent trends in technological advances and globalization, medical device industry may improve the constitution to meet worldwide medical equipment management system. Also it is holding a strand of mitigation to reach the level of international regulation. In addition, recent legislation tends are to stay limited ranges of industry regulations at least and take as open attitude for integration of new technologies combined medical devices. A greater environmental risk is not likely to work in medical technology, Combinded medical device is used as close to zero risk in most of the human body, which is classified as Class 1. Even medical device such as little or no risk in handling, it is possible to minimize the unnecessary administrative power and a waste of time to occur. For the medical device may be improving people's choices and access, medical equipment operator is expanding to include dealers, because this will be exalted to particular area of the business of the company. In this paper, we investigate the legal prerequisites for the establishment of a medical device. And propose improved regulations in topics in order to facilitate the repair and distribution markets for fair trade.

  • PDF