• 제목/요약/키워드: Medial orbital wall fracture

검색결과 38건 처리시간 0.018초

내측 안와벽 골절 처치: Transcaruncular approach (THE TRANSCARUNCULAR APPROACH OF THE MEDIAL ORBITAL WALL FRACTURE)

  • 김현철;최주석;백진아;신효근
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제29권1호
    • /
    • pp.63-70
    • /
    • 2007
  • The occurrence of medial orbital wall fracture is isolated or combined with other facial bone fracture. There are many complications, for example, diplopia, enophthalmos, limitation of eye movement, visual activity depression and blindness. Because of these complications, the accurate diagnosis and treatment of medial orbital wall fracture is very important. We have reconstructed medial orbital walls with transcaruncular approach and obtained good results in patients with medial orbital wall fracture.

Reconstruction of Medial Orbital Wall Fractures without Subperiosteal Dissection: The "Push-Out" Technique

  • Kim, Yong-Ha;Lee, Jin Ho;Park, Youngsoo;Kim, Sung-Eun;Chung, Kyu-Jin;Lee, Jun-Ho;Kim, Tae Gon
    • Archives of Plastic Surgery
    • /
    • 제44권6호
    • /
    • pp.496-501
    • /
    • 2017
  • Background Various surgical methods for repairing medial orbital wall fractures have been introduced. The conventional technique requires total separation of the displaced orbital bones from the orbital soft tissues. However, subperiosteal dissection around the fracture can cause additional damage. The aim of the present study is to introduce a method of reconstructing medial orbital wall fractures without subperiosteal dissection named the "push-out" technique. Methods Six patients with post-traumatic enophthalmos resulting from an old medial orbital wall fracture and 10 patients with an acute medial orbital wall fracture were included. All were treated with the push-out technique. Postoperative computed tomography (CT) was performed to assess the correct positioning of the implants. The Hertel scale and a comparison between preoperative and postoperative orbital volume were used to assess the surgical results. Results Restoration of the normal orbital cavity shape was confirmed by examining the postoperative CT scans. In the old fracture group, the median orbital volume of the fractured side was $29.22cm^3$ preoperatively, and significantly improved postoperatively to a value of $25.13cm^3$. In the acute fracture group, the median orbital volume of the fractured side was $28.73cm^3$ preoperatively, and significantly improved postoperatively to a value of $24.90cm^3$. Differences on the Hertel scale also improved, from 2.13 mm preoperatively to 0.25 mm postoperatively in the old fracture group and from 1.67 mm preoperatively to 0.33 mm postoperatively in the acute fracture group. Conclusions The push-out technique can be considered a good alternative choice for old medial orbital wall fractures with posttraumatic enophthalmos, acute medial orbital wall fractures including large fractured bone segments, and single-hinged greenstick fractures.

내시경을 이용한 비강내 접근법과 속눈썹밑 절개를 동시에 이용한 안와내벽 재건술 (Two Portal Approach(Endoscopic Transnasal and Subciliary) in Medial Orbital Wall Fracture)

  • 장현;동은상;원창훈;윤을식
    • Archives of Plastic Surgery
    • /
    • 제33권5호
    • /
    • pp.552-556
    • /
    • 2006
  • Purpose: As the use of computed tomographic scanning spread, the diagnosis of blow-out fractures of the medial orbital wall increased. Conventionally, the surgery of blow-out fractures in medial orbital wall was performed by various approaches with external incision or endoscopic approach. Although the field of orbital surgery has progressed significantly during the last decade, accurate realignment and replacement of component is difficult due to lack of visualization of the fracture site, blind dissection of the orbital wall, and difficulty in insertion of implant. In order to overcome these shortcomings, we explored the use of endoscopic transnasal approach together with subciliary approach. Methods: The entrapped periorbital tissues in the ethmoid sinus were completely reduced endoscopically, and the bone defect of medial orbital wall was reconstructed with $Medpor^{(R)}$ insertion via subciliary approach. This technique was applied to 13 patients who had medial orbital wall fracture. Results: The patients were followed-up for 3 to 24 months with an average of 9 months. The postoperative courses were satisfactory in all cases. Conclusion: The conjunction of endoscopic transnasal and subciliary approach technique seems to produce good results in medial orbital wall fracture.

Inlay법을 이용한 안와 내벽 골절의 교정 (Inlay Grafting for the Treatment of the Posterior Comminuted Fracture of Medial Orbital Wall)

  • 임종효;김태곤;이준호;김용하
    • 대한두개안면성형외과학회지
    • /
    • 제10권1호
    • /
    • pp.55-60
    • /
    • 2009
  • Purpose: For blowout fracture of the medial orbital wall, the goals of treatment are complete reduction of the herniated soft tissue and anatomic reconstruction of the wall without surgical complications. Surgeons frequently worry about damage to the optic nerve from the dissection, when the part over the posterior ethmoidal foramen was fractured. The authors performed small incision and inlay grafting for reconstruction of medial orbital wall fracture. Methods: Between January 2007 and April 2008, 15 out of 32 patients were included in an analysing the outcome of corrected medial orbital wall fracture. In 15 patients of posterior comminuted fracture of medial orbital wall, insertion of porous polyethylene($Medpor^{(R)}$ channel implant, Porex, USA) to ethmoidal sinus was performed in multiple layer, through the transconjunctival approach (inlay grafting). Results: In all cases, the orbital bone volume was reconstructed in its normal anatomical position. The associated ocular problems disappeared except for mild enophthalmos in 2 patients and there were no surgical complications associated with inlay grafting. Conclusion: The advantage of inlay grafting include anatomical reconstruction of the orbital wall; the avoidance of optic nerve injury; the simplicity of the procedure; and consequently, the absence of surgery-related complications. This technique is presented as one of the preferred treatments for posterior comminuted fracture of medial orbital wall.

The Correlation between the Degree of Enophthalmos and the Extent of Fracture in Medial Orbital Wall Fracture Left Untreated for Over Six Months: A Retrospective Analysis of 81 Cases at a Single Institution

  • Sung, Yun Sik;Chung, Chan Min;Hong, In Pyo
    • Archives of Plastic Surgery
    • /
    • 제40권4호
    • /
    • pp.335-340
    • /
    • 2013
  • Background In patients with medial orbital wall fracture, predicting the correlation between the degree of enophthalmos and the extent of fracture is essential for deciding on surgical treatment. We conducted this retrospective study to identify the correlation between the two parameters. Methods We quantitatively analyzed the correlation between the area of the bone defect and the degree of enophthalmos on computed tomography scans in 81 patients with medial orbital wall fracture who had been left untreated for more than six months. Results There was a significant linear positive correlation between the area of the medial orbital wall fracture and the degree of enophthalmos with a formula of E=0.705A+0.061 (E, the degree of enophthalmos; A, the area of bone defect) (Pearson's correlation coefficient, 0.812) (P<0.05). In addition, that there were no cases in which the degree of enophthalmos was greater than 2 mm when the area of the medial orbital wall fracture was smaller than $1.90cm^2$. Conclusions Our results indicate not only that 2 mm of enophthalmos corresponds to a bone defect area of approximately $2.75cm^2$ in patients with medial orbital wall fracture but also that the degree of enophthalmos could be quantitatively predicted based on the area of the bone defect even more than six months after trauma.

안와내벽골절의 해부학적 복원술 (Anatomical Reconstruction of the Medial Orbital Wall Fracture)

  • 최우경;강동희;오상아
    • 대한두개안면성형외과학회지
    • /
    • 제13권1호
    • /
    • pp.29-35
    • /
    • 2012
  • Purpose: In surgical treatment of the medial orbital wall fractures, restoring the original position of the orbital wall is difficult in some cases. Under such condition, the orbital wall is often reconstructed with synthetic material, without bony reduction, which is considered to be the conventional reconstruction. The purpose of this study is to compare the outcomes of anatomical reconstruction, which restores the bony wall to the anatomical position, from that of the conventional reduction in the isolated medial orbital wall fractures. Methods: Thirty patients, who underwent reconstruction surgery for the isolated medial orbital wall fractures from March 2007 to August 2011, were reviewed retrospectively. The surgical outcomes of two groups, the conventional reconstruction group (15 patients) and the anatomical reconstruction group (15 patients), were studied in 2 measurements, a one day before and 6 months after the surgery. The changes of orbital volume were calculated by the images from a computed tomography scan and enophthalmos was measured by a Hertel exophthalmometer. Results: The orbital volume ratio was decreased by an average of 1.05% in the conventional reconstruction group, while in the anatomical reconstruction group, the ratio decreased by 5.90% (p<0.05). The changes in the Hertel scale were 0.20 mm in the conventional reconstruction group, and 0.70 mm in the anatomical reconstruction group. However, the difference in the Hertel scale was statistically insignificant (p>0.05). Conclusion: In conclusion, the anatomical reconstruction technique of the isolated medial orbital wall fracture results in a better outcome than that of the conventional reconstruction, in terms of restoring of the original orbital volume and anatomic position. Thus, it can be considered as a useful method for the isolated medial orbital wall fractures.

안와내벽외향골절의 비내시경적정복술에 있어 중비도상악동절개술의 장점 (Advantage of Middle Meatal Antrostomy in Transnasal Endoscopic Reconstruction of Medial Orbital Blow-out Fracture)

  • 김순흠;이수향;최현곤;신동혁;엄기일;김보형
    • Archives of Plastic Surgery
    • /
    • 제34권6호
    • /
    • pp.735-740
    • /
    • 2007
  • Purpose: Blowout fracture is an outward fracture of the orbital wall. That usually occurs at inferior or medial wall of the orbit. The main pathophysiology is high intraocular pressure derived from impact of trauma. Among the four orbital wall, the medial wall is thinnest and most vulnerable to trauma. Many kinds of methods were introduced for correction of medial orbital wall fracture. Recently, transnasal endoscopic reconstruction methods were widely used. Endoscopic methods had many advantages. However, we experienced some cases of postoperative maxillary sinusitis. This study was planned to find out the effectiveness of middle meatal antrostomy after endoscopic reconstruction of medial orbital wall fracture. Methods: This study was retrospective analysis of 28 patients who underwent transnasal endoscopic repair of medial orbital wall fracture. The 18 male and 10 female patients were ranged from 17 to 57 years of age(mean, 30.9 years). Among 28 patients, randomly selected 17 patients underwent middle meatal antrostomy as additional procedure by the same surgeon. After at least 12 months of follow-up period, we examined the nasal symptom, endoscopic and CT findings. Results: One patient complained of nasal obstruction in middle meatal antrostomy group and four patients complained nasal symptoms in non middle meatal antrostomy group. On the endoscopic findings, three patients of non middle meatal antrostomy group had continuous nasal discharge. But middle meatal antrostomy group had no abnormal endoscopic findings. The abnormal CT finding(abnormal mucosal hypertrophy) were detected in four patient of non middle meatal antrostomy group. There were no abnormal CT findings in middle meatal antrostomy group. The data were statistically significant at comparative study. Conclusion: Authors think that the middle meatal antrostomy has some advantages as a additional procedure of endoscopic reconstruction of medial orbital wall fracture. Especially, it is good at preventing postoperative maxillary sinusitis. But, more larger group and strict application of disease entity are need for correct evaluation of middle meatal antrostomy effect.

A useful additional medial subbrow approach for the treatment of medial orbital wall fracture with subciliary technique

  • Kim, Seung Min;Kim, Cheol Keun;Jo, Dong In;Lee, Myung Chul;Kim, Ji Nam;Choi, Hyun Gon;Shin, Dong Hyeok;Kim, Soon Heum
    • 대한두개안면성형외과학회지
    • /
    • 제20권2호
    • /
    • pp.101-108
    • /
    • 2019
  • Background: To date, a variety of surgical approaches have been used to reconstruct the medial orbital wall fracture. Still however, there is still a controversy as to their applicability because of postoperative scars, injury of anatomical structures and limited visual fields. The purpose of this study was to introduce a useful additional medial subbrow approach for better reduction and securement more accurate implant pocket of medial orbital wall fracture with the subciliary technique. Methods: We had performed our technique for a total of 14 patients with medial orbital wall fracture at our medical institution between January 2016 and July 2017. All fractures were operated through subciliary technique combined with the additional medial subbrow approach. They underwent subciliary approach accompanied by medial wall dissection using a Louisville elevator through the slit incision of the medial subbrow procedure. This facilitated visualization of the medial wall fracture site and helped to ensure a more accurate pocket for implant insertion. Results: Postoperative outcomes showed sufficient coverage without displacement. Twelve cases of preoperative diplopia improved to two cases of postoperative diplopia. More than 2 mm enophthalmos was 14 cases preoperatively, improving to 0 case postoperatively. Without damage such as major vessels or extraocular muscles, enophthalmos was corrected and there was no restriction of eyeball motion. Conclusion: Our ancillary procedure was useful in dissecting the medial wall, and it was a safe method as to cause no significant complications in our clinical series. Also, there is an only nonvisible postoperative scar. Therefore, it is a recommendable surgical modality for medial orbital wall fracture.

안와벽 골절 면적과 이탈된 안와내 조직의 부피에 따른 안구함몰 정도 (Degree of enophthalmos according to the extent of orbital wall fracture and volume of herniated orbital tissue)

  • 장학선;임대호;백진아;신효근;고승오
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제37권3호
    • /
    • pp.205-213
    • /
    • 2011
  • Introduction: The enlargement and deformation of the orbit give rise to a visible enophthalmos. As a consequence, a disturbance of eye motility together with double images is likely to occur. This study examined the degree of enophthalmos according to the extent of orbital wall fracture and volume of herniated orbital tissue in blowout fractures of the medial and inferior orbital wall. Materials and Methods: This study was performed on patients diagnosed with medial and inferior orbital wall fractures at the Department of Oral and maxillofacial surgery, Chonbuk National University Hospital from 2007 to 2009. The patients' age, gender, etiology of fracture and degree of enophthalmos were investigated. The changes in the degree of enophthalomos, diplopia and ocular motility restriction after operation were examined. Results: The degree of enophthalomos increased with increasing extent of orbital wall fracture and volume of herniated orbital tissue. Conclusion: Whether to perform the operation is decided after measuring the extent of the orbital wall fracture and volume of herniated orbital tissue using computed tomography (CT), time for the decision of operation can be shortened. This can cause a decrease in the complications of orbital wall fractures.

Three-Dimensional Pre-Bent Titanium Implant for Concomitant Orbital Floor and Medial Wall Fractures in an East Asian Population

  • Lee, Kyung Min;Park, Ji Ung;Kwon, Sung Tack;Kim, Suk Wha;Jeong, Eui Cheol
    • Archives of Plastic Surgery
    • /
    • 제41권5호
    • /
    • pp.480-485
    • /
    • 2014
  • Background The objective of this article is to evaluate clinical outcomes of combined orbital floor and medial wall fracture repair using a three-dimensional pre-bent titanium implant in an East Asian population. Methods Clinical and radiologic data were analyzed for 11 patients with concomitant orbital floor and medial wall fractures. A combined transcaruncular and inferior fornix approach with lateral canthotomy was used for the exposure of fractures. An appropriate three-dimensional preformed titanium implant was selected and inserted according to the characteristics of a given defect. Results Follow-up time ranged from 2 to 6 months (median, 4.07 months). All patients had a successful treatment outcome without any complications. Clinically significant enophthalmos was not observed after treatment. Conclusions Three-dimensional pre-bent titanium implants are appropriate for use in the East Asian population, with a high success rate of anatomic restoration of the orbital volume and prevention of enophthalmos in combined orbital floor and medial wall fracture cases.