• 제목/요약/키워드: Medial opening

검색결과 51건 처리시간 0.035초

관골궁 골절 환자에서 함몰 방지를 위한 Aqua splint®를 이용한 보호대 (Prevention for Collapse Using Aqua Splint® in Zygoma Arch Fractures)

  • 서우진;김창연;황원중;김정태
    • Archives of Plastic Surgery
    • /
    • 제34권6호
    • /
    • pp.813-817
    • /
    • 2007
  • Purpose: The zygomatic arch is a key element which composes the facial contour. In many cases of zygomatic arch fracture, it is difficult to fix rigidly the fractured segments. If reduced bone segments were not fixed rigidly, they are proven to be displaced by mastication or unintentional external forces. So, unfixed zygomatic arch fracture after reduction may require a external device of prevention of collapse. We introduce a new protector which stabilizing the fractured segments to prevent for collapse of the reduced zygomatic arch fracture. Methods: After reduction of zygomatic arch with blind approach(Gillies', Dingman or Keen's approach), bone segments was pulled with percutaneous traction suture in medial aspect of zygomatic arch. Then, the suture was fixed with Aqua $splint^{(R)}$, externally. And intraoperative and postoperative X-ray was done. The splint was removed on 14 days after the operation. Results: 5 patients were treated with this method. 4 patients of total patients had no collapse in zygomatic arch. There was minimal collapse in one patient. Postoperative complications such as facial nerve injury, mouth opening difficulty, contour deformity, infection, scar were not observed. Conclusion: In comparison with other techniques, this technique has several advantages which are simple and easy method, short operation time, no scar, less soft tissue injury, and facilitated removal of splint. Therefore, Aqua $splint^{(R)}$ would be a good alternative to prevent for collapse in unstable zygomatic arch fractures

Congenital Anomalies of Lower Lacrimal Puncta and Nasolacrimal Duct Atresia in a Labrador Retriever Dog

  • Park, Eun-Jin;Kang, Seon-Mi;Park, Sang-Wan;Kwak, Ji-Yoon;Lim, Jae-Gook;Nam, Taek-Jin;Jeong, Seo-Woo;Seo, Kangmoon
    • 한국임상수의학회지
    • /
    • 제33권4호
    • /
    • pp.228-230
    • /
    • 2016
  • An 1-year-old, spayed, female Labrador Retriever was presented for bilateral epiphora. A complete ophthalmic examination was conducted, including Schirmer tear test, rebound tonometry, fluorescein staining, slit lamp biomicroscopy, and binocular indirect ophthalmoscopy. To determine the patency of the nasolacrimal duct system, a nasolacrimal flush and dacryocystorhinography were also performed. Although the nasolacrimal flush showed patency in the upper and lower lacrimal puncta in both eyes (OU), the lower lacrimal puncta were not found in the original palpebral conjunctiva, but on medial canthal skin with very small opening. Moreover, the nasolacrimal ducts in OU were not patent with flushing. Bilateral nasolacrimal duct atresia was confirmed by dacryocystorhinography. No other abnormalities of the eyes were found on complete ophthalmic examinations. Bilateral congenital anomalies of the lower lacrimal puncta and nasolacrimal duct atresia were diagnosed in this dog.

Retromandibular reduction of medially dislocated condylar process fractures

  • Lee, Gyu Hyeong;Kang, Dong Hee;Oh, Sang Ah
    • Archives of Plastic Surgery
    • /
    • 제45권1호
    • /
    • pp.23-28
    • /
    • 2018
  • Background Condylar process fractures account for one-third of all mandibular fractures, and the distal fragment is prone to dislocate to the medial side due to the pulling of the lateral pterygoid muscle. Retromandibular approaches are commonly used, but the intraoperative view becomes limited in medially dislocated fractures. This study summarized a series of cases of retromandibular reduction for medially dislocated condylar process fractures and described our supplementary procedure to realign the dislocated condylar process. Methods Nine patients with medially dislocated condylar process fractures underwent surgical correction from January 2012 to December 2016. In 6 of them, it was possible to realign the fractures with a conventional retromandibular approach, but for 3 cases of severe dislocation to the middle cranial fossa, a supplementary transoral procedure was carried out. The angle difference between the ramus and condyle, ramus height, and maximal mouth opening (MMO) were evaluated. Results All 9 cases were restored to the proper anatomical alignment without any major complications, and postoperative images revealed successful union. The angle difference was $8.94^{\circ}{\pm}4.11^{\circ}$ preoperatively, and $0.99{\pm}0.49^{\circ}$ at the 6-month follow-up. The pretreatment ramus height difference was $6.12{\pm}6.09mm$, and the postoperative difference was $0.18{\pm}0.10mm$. These changes after surgery were statistically significant. The MMO before surgery was $11.44{\pm}3.0mm$, and the postoperative MMO was $37.2{\pm}2.9mm$, reflecting a significant increase after reduction. Conclusions Retromandibular reduction is a useful method in medially dislocated condylar process fractures, and additional transoral assistance should be considered to realign condylar processes that severely dislocate to the middle cranial fossa.

중증 치매환자복 형태에 따른 근육 부하 및 피로도 평가 (Evaluation of Muscle Load and Fatigue According to the Shape of Severe Dementia Patients' Clothing)

  • 박광애;양정은;정하영
    • 한국의류산업학회지
    • /
    • 제25권2호
    • /
    • pp.185-198
    • /
    • 2023
  • The purpose of this study is to obtain information necessary for the development of patient clothes that can reduce physical fatigue of caregivers by quantitatively measuring the muscle load and fatigue. The patient clothes used in this study can be broken down into three types: A type (back center zipper open suit), B type (top-to bottom separated patient clothes), and C type (front zipper open suit). The EMG measurement sites are as follows: hand muscle (brachioradialis), upper arm (biceps, triceps), shoulder (anterior deltoid, medial deltoid, posterior deltoid, upper trapezius), and waist (erector spinae); additionally, the EMG signals were measured. Through this experiment, muscle load, muscle energy consumption, and muscle fatigue generation tendency were analyzed. The results of the study revealed that the C type patient clothes required the most strength in the muscles of the shoulders, upper arms, hands, and back when being put on and taken off compared to other patient clothes. The A type clothes required a relatively large force in opening the zipper. In terms of muscle energy consumption, B type generally called for more strength when it came to the zip-up and putarmsup motions. With regard to the cover the body and put legs/hips up motions, C type used the highest amount of muscle energy, whereas A type used relatively little energy. In terms of the occurrence of muscle fatigue during the putting on and taking off of the patient's clothing, there was a difference in the area and degree of muscle fatigue in the A, B, and C types, and there was also a tendency for muscle fatigue to occur when performing repetitive movements.

한국인의 측두하악관절에서 Dental cone-beam CT를 이용한 관절융기의 경사도에 대한 방사선학적 평가 (Radiographic Evaluation of Stiffness of Articular Eminence in the Temporomandibular Joint(TMJ) of Korean Using Dental cone-beam CT)

  • 오상천;한지석
    • 구강회복응용과학지
    • /
    • 제29권2호
    • /
    • pp.163-173
    • /
    • 2013
  • 하악의 개구운동 시, 과두-관절원판 복합체는 관절융기를 따라서 활주운동을 하게 되므로 관절융기의 형태는 측두하악관절의 기능적인 움직임을 이해하는데 매우 중요한 부분이다. 본 연구의 목적은 치과용 cone-beam CT를 이용하여 관절융기의 후방경사를 계측하고, 관절융기의 경사도에 대한 과두의 병적 변화의 영향을 평가하며, 성별과 연령에 따른 관절융기의 차이를 비교 하는 것이다. 이를 위해 원광대학교 산본치과병원에 내원한 102명(남자:43명, 여자:49명, 평균나이: 37.7세)의 204개 측두하악관절의 cone-beam CT 영상을 평가하였으며, 모든 영상은 측두하악관절 분석모드로 전환하여 양측 관절의 연속된 시상 단면 이미지와 관상 단면 이미지를 관찰하였다. 신뢰성있는 데이터를 얻기 위해 숙련된 3명의 치과의사가 동일한 이미지 파일을 보며 판독 작업을 시행하였고, 3명 중 2명의 판독 결과가 동일할 경우만 최종 판독 결과로 기록하였다. 정상과두(NCBC)와 골변화를 동반한 과두(CBC)의 관절융기 경사도는 내측이 $57.0^{\circ}$(NCBC)과 $51.8^{\circ}$(CBC), 중심이 $57.9^{\circ}$(NCBC)과 $52.4^{\circ}$(CBC), 그리고 외측이 $55.1^{\circ}$(NCBC)과 $49.5^{\circ}$(CBC)를 나타냈고, 골변화를 보이는 과두가 정상과두보다 낮은 관절융기 경사도를 보였다. 이러한 차이는 성별이나 연령에 따른 통계적 유의성은 없었다.

하악과두의 골증식체 평가에 있어서 transmaxillary 촬영법과 transcranial 촬영법의 비교 (COMPARISON OF TRANSMAXILLARY AND TRANSCRANIAL PROJECTION IN THE EVALUATION OF OSTEOPHYTES Of MANDIBULAR CONDYLES)

  • 김태균;김진수
    • 치과방사선
    • /
    • 제19권1호
    • /
    • pp.123-136
    • /
    • 1989
  • 5개의 건조두개골의 하악과두에 인위적으로 골증식체를 형성한 후 수직각 25°, 수평각 0°를 부여한 transcranial 촬영법과 두부규격 방사선 촬영기를 이용한 transmaxillary 촬영법을 시행하여 얻은 90매의 transcranial 및 45매의 transmaxillary방사선사진을 통해 다음과 같은 결론을 얻었다. 1. transcranial 촬영법에서 골증식체가 하악과두의 상중부에 있을 때 폐구시에 관찰이 용이하였으나 (p<0.05), 그 이외의 부위에서는 통계학적인 유의성이 없었다(p>0.05). 2. 골증식체가 하악과두의 내부 및 중부 (p<0.05)에 위치하였을 때는 transmaxillary 촬영법에서 관찰이 더 용이하였으며 외부에 위치하였을 때는 통계학적인 유의성이 없었다 (p>0.05). 3. 골증식체가 하악과두의 상방(p<0.05) 및 후방(p<0.01.)에 위치하였을 때는 trans maxillary 촬영법에서 관찰이 더 용이하였으며 전방에 위치하였을 때는 통계학적인 유의성이 없었다. (p>0.05). 4. Transcranial 촬영법에서는 골증식체가 하악과두의 측방으로 위치할수록(p<0.01), transmaxillary 촬영법에서는 후방으로 위치할수록(p<0.35) 관찰이 용이하였다.

  • PDF

Development of Two-Dimensional Scanning Videokymography for Analysis of Vocal Fold Vibration

  • Wang, Soo-Geun;Lee, Byung-Joo;Lee, Jin-Choon;Lim, Yun-Sung;Park, Young Min;Park, Hee-June;Roh, Jung-Hoon;Jeon, Gye-Rok;Kwon, Soon-Bok;Shin, Bum-Joo
    • 대한후두음성언어의학회지
    • /
    • 제24권2호
    • /
    • pp.107-111
    • /
    • 2013
  • Objectives : We developed two-dimensional (2D) scanning videokyomography to evaluate the mucosal wave of whole vocal cords in real time to overcome the limit of preexisting stroboscopy and line scanning videokymography which could not evaluate it. Methods : We implemented a continuous light source with high brightness, a high-definition CMOS camera, and capture board for saving the data. We created the software program to analyze the image data from the system. The test of the functionality of the 2D scanning videokymography camera was performed in one of the authors (P.H.J 32 years old male). Vocal cord images were obtained during normal phonation and falsetto phonation. Images were obtained also during cough, diplophonia. Results : The system made it possible to measure objective parameters, including fundamental frequency, amplitude, regularity, mucosal wave, and phase difference, medial and lateral peak, opening versus closing duration related to vocal fold vibration. Simultaneously, it enabled analysis of the whole mucosal wave of the entire vocal fold in real time. 2D scanning videokymography was also effective for evaluating the dynamic status of the vocal fold when the subject phonated aperiodic voice. Conclusion : In conclusion, 2D scanning videokymography can support the analysis of the whole mucosal wave of the entire vocal cord with objective vocal parameters, overcoming the limitations of stroboscopy and previous line scanning videokymography techniques.

  • PDF

한국재래산양 삼차신경에 관한 해부학적 연구 (Anatomical studies on trigeminal nerve of Korean native goat)

  • 신남식;이흥식;이인세;강태천;김진상;이종환;서제훈
    • 대한수의학회지
    • /
    • 제38권3호
    • /
    • pp.474-487
    • /
    • 1998
  • The present study was undertaken to investigate the morphological characteristics of trigeminal nerve in the Korean native goat by macroscopic methods. Trigeminal nerve was originated from the lateral side of pons, and extended shortly forward to form trigeminal ganglion at the opening of oval foramen. Thereafter this nerve was divided into maxillary, mandibular and ophthalmic nerve. Ophthalmic nerve gave off the zygomaticotemporal branch, frontal nerve, frontal sinus branch, and was continued as the nasociliary nerve. Maxillary nerve gave rise to the zygomaticofacial branch, accessory zygomaticofacial branch, communicating branch with oculomotor nerve, pterygopalatine nerve, caudal superior alveolar branch, malar branch and was continued as the infraorbital nerve. Mandibular nerve was divided into the masseteric nerve, buccal nerve, lateral pterygoid nerve, medial pterygoid nerve, nerve to tensor tympani m., auriculotemporal nerve, and furnished the inferior alveolar nerve and lingual nerve as terminal branches. The course and distribution of the trigeminal nerve in the Korean native goat appeared to be similar to that in other small ruminants such as sheep and goat. But the main differences from other small ruminants were as follows : 1. There was no accessory branch of the major palatine nerve. 2. The caudal superior alveolar branch was directly branched from the maxillary nerve. 3. The communicating branch with oculomotor nerve was originated from maxillary nerve or common trunk with zygomaticofacial branch. 4. The malar branch arose from the maxillary nerve at the rostral to the origin of the caudal superior alveolar branch. 5. The inferior alveolar nerve originated in a common trunk with the lingual nerve. 6. The mylohyoid nerve arose at the origin of the inferior alveolar nerve. 7. The zygomaticotemporal branch was single fascicle, and gave off lacrimal nerve and cornual branch. 8. The base of horn was provided by the cornual branches of zygomaticotemporal branch and infratrochlear nerve of nasociliary nerve.

  • PDF

가물치의 위장내 기생하는 흡충(Azygia속) 및 선충(Pingus속)의 동정과 감염상황 (Identification and prevalence of trematode(Gen Azygia) and nematode(Gen Pingus) in Ophicephalus argus)

  • 문무홍;이은우
    • 대한수의학회지
    • /
    • 제38권1호
    • /
    • pp.147-159
    • /
    • 1998
  • A survey of the internal parasites in 115 fishes of Ophicephalus argus was carried out in Kyungpook province during the period from January 1995 to November 1997. A species of trematode from the stomach and a species of nematode from the caeca of the fishes was discovered respectively. The trematode was identified as Azygia hwangtsinyi (Tsin, 1993) and the nematode as Pingus sinensis ($Hs\ddot{u}$, 1993). The fluke was pressed at thick of 0.1mm~0.2mm between slide glasses and fixed in 70% ethyl alcohol solution. The fluke was washed with tap water after fixation and stained with hematoxylin-carmin and mounted in balsam through routine methods. The nematode was fixed in 5% formalin solution and mounted with lactophnol or glycerine jelly. Morphology : Arygia hwantsinyi ; The fluke is elongate body with approximately parallel margins and rounded extremities in pressed preparations(Fig 1). The cuticle is unarmed. The oral sucker is ventro-subterminal in position. The ventral sucker is slightly smaller than oral sucker and positioned at 14.2% of body length from the oral sucker. The cirrus sac and genital pore is in mid-ventral line, slightly anterior to the ventral sucker. The oral sucker is succeeded by a well developed muscular pharynx. It is succeeded by a short inverted Y-shaped oesophagus. The inner wall of oesophagus is consisted of many fine folded membrane. The fine tubes of esophagus pass into the intestinal heads which are distended and presented a marked borderline between the fine tube and intestinal heads. The Intestinal heads start at level of pharynx and pass caudad in a zigzag course to end quite near caudal margin. The uterine coils occupy the intercecal area between the level of the cephalic margin of the ovary and about the level of the ventral sucker. The uterus is filled with many eggs. The testes are round or oval and placed one behind the other generally a little diagonally. The posterior testis is placed at level of 75.1% of body length. The ovary is oval, placed ahead the anterior testis. The shell gland not discernible outline is contacted with ovary ahead it. The vitelline glands are consisted of small oval vesicles. The vesicles occupy extracecal regions and between a little posterior of the ventral sucker and near caudal margin. Pingus sinensis : Female ; The cuticle is smooth and the cervical alae are well developed. The mouth opening is small, triangular, and without lips. The anterior end bears four sub-medial papillae. The oesophagus is divided into a muscular and glandular portion. The nerve ring is situated just at the junction of the muscular and glandular portions of the oesophagus. The vulva which has a prominent flap, is placed behind the middle of the body about one-third of the length of the worm from the posterior extremity. The vagina is strongly muscularised and after running anteriorly about $68{\mu}$, divides itself into two broad uterine tubes with an anterior and a posterior one. There are a few eggs in the uterine tubes. The tail is slender, straight and pointed. The ovary extends almost to the posterior extremity. Male : Male is smaller than female. The tail is pointed, curved and carrying well-developed caudal alae. A prominent muscular precloacal sucker is characteristic. The spicules are equal and short. There are four pairs of pedunculated pre-anal papillae, of which the most anterior pair are situated just at the level anterior to the muscular sucker. Two pairs of pedunculated papillae are present before the anus. There are five pairs of post-anal papillae of which the most anterior pair and the second counted from the posterior end are ventral and more marked than the ones which are situated laterally.

  • PDF

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF