• Title/Summary/Keyword: Mechanical power test

Search Result 1,287, Processing Time 0.024 seconds

Study of the Functional Test and Quality Assurance Procedure of High Performance Aircraft Control Surfaces Integrate Servo Actuator (고성능 통합 비행 조정면 구동 장치의 성능 시험 및 품질보증 절차 수립에 관한 연구)

  • Jo, Jang-Hyen
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.3 no.3
    • /
    • pp.251-256
    • /
    • 2000
  • This report analyzes the Source Qualification Test which is composed of main functional and environmental tests for the localizing avionics(electronic subsystem for aircrafts and spacecraft) and high performance mechanical subsystem. Especially the detail test approaches of integrated servo actuators which is the main part to supply the power to the main and other flying control panel. Nowadays this subsystem works with mechanical and electrical engineering technique. In detail, electrical signal is used as input and transferring tool and mechanical part is the output as a power and manufacture the physical dimensions and functions. Finally in this review, the new test procedure to prove the function by the new manufacturer is established.

  • PDF

Leakage Prevention of Mechanical Seal in a Feed Water Pumpof Power Plant with Oxygen Water Treatment (산소주입 수처리 발전소용 급수펌프 밀봉장치의 누설방지)

  • Shin, Jung-Gook;Moon, Seung-Jae;Yoo, Hoseon
    • Plant Journal
    • /
    • v.7 no.1
    • /
    • pp.56-63
    • /
    • 2011
  • The identifying cause of leakage problems on mechanical seal in a feed water pump of power plant have been difficult because of technical limits of domestic mechanical seal manufacturer and the various conditions of power plants. This paper can get a conclusion through the consideration study and experiment test of mechanical seal characteristics of feed water pump depending on oxygen treatment as follows. The oxygen treatment increase dissolved oxygen and cause a corrosion on the mechanical seal stationary ring composed of antimony as well as leakage problems. For solving leakage problems of seal, to eliminate dissolved oxygen in the cooling water of seal with hydrazine injection can prevent leakage problems of mechanical seal in feed water pump.

  • PDF

Development of a Test Facility for Cold-air Performance of Small Axial Turbine (소형 축류터빈의 상온 성능시험기 개발)

  • 손창민;차봉준;이대성
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.7
    • /
    • pp.1780-1786
    • /
    • 1995
  • The main goal of the present study is to establish the techniques and methodolgies of turbine performance test through evaluating the objective turbine test piece, and checking the reliability of the self-developed test facility by performing a series of turbine tests under ambient temperature condition. A high speed coupling, a lubrication system and a test bed of the test facility were modified through a series of preliminary test in order to reduce the vibration and oil leakage. The flowrate control of the test facility and data acquisition were accomplished by using a software called "Labview" The measurement of shaft horse power and control of rotational speed according to the conditions of turbine rotation were performed by a separate system. The preliminary evaluation of the measured data suggests that the developed test facility and the test technique can be used reliably for the performance test of turbines with the minor improvement.provement.

Development of simulation-based testing environment for safety-critical software

  • Lee, Sang Hun;Lee, Seung Jun;Park, Jinkyun;Lee, Eun-chan;Kang, Hyun Gook
    • Nuclear Engineering and Technology
    • /
    • v.50 no.4
    • /
    • pp.570-581
    • /
    • 2018
  • Recently, a software program has been used in nuclear power plants (NPPs) to digitalize many instrumentation and control systems. To guarantee NPP safety, the reliability of the software used in safetycritical instrumentation and control systems must be quantified and verified with proper test cases and test environment. In this study, a software testing method using a simulation-based software test bed is proposed. The test bed is developed by emulating the microprocessor architecture of the programmable logic controller used in NPP safety-critical applications and capturing its behavior at each machine instruction. The effectiveness of the proposed method is demonstrated via a case study. To represent the possible states of software input and the internal variables that contribute to generating a dedicated safety signal, the software test cases are developed in consideration of the digital characteristics of the target system and the plant dynamics. The method provides a practical way to conduct exhaustive software testing, which can prove the software to be error free and minimize the uncertainty in software reliability quantification. Compared with existing testing methods, it can effectively reduce the software testing effort by emulating the programmable logic controller behavior at the machine level.

A Study on the Dynamic Analysis and Control Algorithm for a Motor Driven Power Steering System

  • Yun, Seokchan;Han, Changsoo;Wuh, Durkhyun
    • Journal of Mechanical Science and Technology
    • /
    • v.16 no.2
    • /
    • pp.155-164
    • /
    • 2002
  • The power steering system for vehicles is becoming essential for supporting the steering efforts of the drivers, especially for the parking lot maneuver Although hydraulic power steering has been widely used for years, its efficiency is not high enough. The problems associated with a hydraulic howe. steering system can be solved by a motor driven power steering (MDPS) system. In this study, a dynamic model and a control algorithm for the ball screw type of MDPS system have been derived and analyzed by using the method of discrete modeling technology. To improve steering feel and power steering characteristics, two derivative gains are added to the conventional power boosting control algorithm. Through simulations, the effects of the control gain on the steering angle gain were verified in the frequency domain. The steering returnability and steering torque phase lag in on-center handling test were also evaluated in the time domain.

A Study on the Development of Controller which is used Electric Operating Cell(EOC) for Vacuum Circuit Breaker and the Controller Performance Certification Test (진공차단기용 전자식 보조접점 컨트롤러 개발 및 성능인증시험에 관한 연구)

  • Lee, Ki-Seon;Park, Jung-Cheul;Chu, Soon-Nam
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.64 no.3
    • /
    • pp.130-137
    • /
    • 2015
  • This study is about the controller development of the Electric Operating Cell(EOC) which will replace the Mechanical Operated Cell(MOC) of the vacuum circuit breaker which has been used in the power plant and the performance test for the developed controller. The controller developed through this study was manufactured considering the harsh installation environment and electrical condition of the power plant, and the controller performance certification test for confirming the product reliability was taken to know whether or not to withstand fully in various electrical and mechanical problems. Items for performance certification test were AC power frequency voltage withstand test, combined surge immunity test, 1 [MHz] oscillatory SWC test, fast transient SWC test, radiated electromagnetic interference test, vibration test. As a result, all tests has passed an examination without malfunction.

Creep Rupture Life Prediction of High Temperature HRSG Tubes (고온 폐열회수장치 튜브의 크리프 파단특성 평가)

  • Kim, Woo Joong;Kim, Jae Hoon;Jang, Jung Cheol;Kim, Beom Soo;Lee, Gi-Chun
    • Journal of the Korean Society of Safety
    • /
    • v.28 no.3
    • /
    • pp.6-10
    • /
    • 2013
  • The Heat Recovery Steam Generator(HRSG) is a device recycling the exhaust gas of gas turbine in combined power and chemical plants. Since service temperatures was very high, the damage of HRSG tubes intensively occurred in superheater and reheater. The aim of this paper is to determine life and hardness relationship that addresses creep-rupture test and creep-interrupt test in modified 9Cr-1Mo steel. The measured life that consists of function of hardness was found to constant tendency.

Research on the Power Drop of Photovoltaic Module’s Aging Through the Thermal Shock Test

  • Kang, MinSoo;Jeon, YuJae;Kim, DoSeok;Shin, YoungEui
    • Transactions on Electrical and Electronic Materials
    • /
    • v.16 no.5
    • /
    • pp.268-273
    • /
    • 2015
  • While analyzing the specimens before and after the thermal shock test, we found that the power drop rate of the bare cell was 5.08%, while the power drop rate of the ribboned cell was 16.49%. In comparative terms, the efficiency was lower at the ribboned cell than at the bare cell. While analyzing through EL (Electroluminescence) shots and cross sections, we tried to decipher the exact cause of the power drop. Although mere color change of the cell was observed at the surface of the bare cell, no abnormality could be found inside the cell. On the surface of the ribboned cell, the short circuit of gridfinger extended from the front part of the front electrode of the ribboned cells. Therefore, cracks occurred on the surface of the cell. Cracks also appeared inside the cell. While analyzing the I-V curve, we determined an increase in the leakage current and an increase of resistances in series in the bare cell. In the ribboned cell, the resistances in parallel reduced remarkably. An increase of resistances in series could also be verified. Conclusively, we deduced that the power drop rate in the bare cell is a life span of the cell itself; aging is the cause of power drop rate in cells. In case of ribboned cell, the power drop rate was directly influenced by internal cracks and an intermetallic compound layer joining the ribbon at the front electrode.

The effect of low power GaAlAs laser stimulation on anti-nociception and spinal neuronal activity related to pain sensation in the polyarthritis of rats (다발성 관절염 실험동물 모델에서 저출력 GaAlAs 레이저 자극의 진통효능 및 통증관련 척수내 신경세포의 활성변화에 관한 연구)

  • Chang, Moon-Kyung;Choi, Young-Duk;Park, Bong-Soon
    • Journal of Korean Physical Therapy Science
    • /
    • v.10 no.1
    • /
    • pp.180-189
    • /
    • 2003
  • The experiments were designated to evaluate the anti-nociceptive effect of low power laser stimulation on acupoint or non-acupoint using arthrogenic solution induced poly arthritis animal model. Evaluation of potential antinociceptive effect of low power laser on arthritis has employed measurements of the foot bending test, the development of either thermal or mechanical hyperalgesia following the arthritis induction. The analysis of thermal hyperalgesia includes Hargreaves's method. Randall-Sellitto test was utilized for evaluating mechanical hyperalgesia. In addition, the antinociceptive effect of low power laser stimulation on arthritis induced spinal Fos expression was analyzed using a computerized image analysis system. The results were summerized as follows: 1. In laser stimulation on acupoint treated animal, laser stimulation dramatically inhibited the development of pain in foot bending test as compared to those of non acupoint treated animal group and non treated animal group. 2. The threshold of thermal stimulation was significantly increased by low power laser stimulation on acupoint as compared to that of non treated control group. 3. Laser stimulation on acupoint dramatically attenuated the development of mechanical hyperalgesia as compared to that of non treated group. 4. Low power laser stimulation on acupoint significantly suppressed arthritis induced Fos expression in the lumbar spinal cord at 3 week post arthritis induction. In conclusion, the results of the present study demonstrated that low power laser stimulation on acupoint has potent anti-nociceptive effect on arthritis. Additional supporting data for an antinociceptive effect of laser stimulation was obtained using Fos immunohistochemical analysis on spinal cord section. Those data indicated that laser stimulation induced antinociception was mediated by suppression of spinal neuron activity in pain sensation.

  • PDF

The Study on Thermal Shock Test Characteristics of Solar Cell for Long-term Reliability Test (장기 신뢰성 평가를 위한 태양전지의 열충격 시험 특성에 관한 연구)

  • Kang, Min-Soo;Kim, Do-Seok;Jeon, Yu-Jae;Shin, Young-Eui
    • Journal of Energy Engineering
    • /
    • v.21 no.1
    • /
    • pp.26-32
    • /
    • 2012
  • This study has been performed Thermal Shock test for analyze the cause of Power drop in PV(Photovoltaic) Module. Thermal Shock test condition was performed with temperature range from $-40^{\circ}C{\sim}85^{\circ}C$. One cycle time is 30min. which are consist of low and high temperature 15min. each other. The test was performed with total 500cycles. EL, I-V were conducted every 100cycle up to 500cycles. Mono Cell resulted in 8% Power drop rates in Bare Cell and 9% in Solar Cell. In the case of Multi Cell resulted in 6% Power drop rates in Bare Cell and 13% in Solar Cell. After Thermal Shock test, Solar Cell's Power drop resulted from surface damages, but in the case of Bare Cell's Power drop had no surface damages. Therefore, Bare Cell's Power drop was confirmed as according to leakage current increase by analysis of Fill Factor after Thermal Shock test. Also, Solar Cell's Power drop rates are higher than that of Bare Cell because of surface damages and consuming electric power increase. From now on, it should be considered that analyzed the reasons of Fill Factor decrease and irregular Power drop in PV module and Cell level using cross section, various conditions and test methods.