• Title/Summary/Keyword: Measuring tool

Search Result 1,280, Processing Time 0.026 seconds

A Study on the Strain Measuring of Structure Object (전자처리 및 Laser 간섭에 의한 구조물의 Strain측정에 관한 연구)

  • 김경석;최형철;양승필;정현철;김정호
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1993.10a
    • /
    • pp.267-272
    • /
    • 1993
  • This paper presents the performance and problems in analysis method and testing system of Electronic Speckle Pattern Interferometry (ESPI) method, in measuring two-dimensional in-plane displacement. The anyalysis result of measurement by ESPI is quite comparable to that of measurement by strain gauge method. This implieds that the method of ESPI is a very effective tool in non-contact two-dimensional in-planc strain analysis. But there is a controversal point,measurment error. This error is discussed to be affected not by ESPI method itseif, but by its analysis scheme of the interference fringe,where the first-order interpolation has been applied to the points of strain measured. In this case, it is turned out that the more errors would be occured in the large interval of fringe. so, this paper describes a computer method for drawing when the height is available only for some arbitary collection of points, the method is based on a distance-weighted, least-squares approximation technique, with the weight varying with the distance of the data points.

  • PDF

A Study on Improvement in a Method of Three Dimensional Configuration Scan Measurement (3차원 형상 스캔의 측정방법 개선에 관한 연구)

  • 김태호;김민주;이승수;박정보;전언찬
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2001.10a
    • /
    • pp.375-380
    • /
    • 2001
  • This study is on the precision of the optical scanner which is suitable for shape modeling and non-contact equipment, comparing with a razer scanner. The optical scanner not only has all merits that non-contact methods have but also improve a veil phenomenon which is a razer scanner's demerits. However, the optical scanner has not been used extensively because the measurements are not very precise and there are not the definite methods of measurement. Hence, this study is to find out how parameters such as camera's hight, angle, luminous intensity, distance to object, and so on have an influence on measuring using the optical scanner and to establish the methods of measuring precision.

  • PDF

Development of a CAT System for Measuring and Analysing the Ride and Handling Performances of Vehicle under Windows GUI Environment (윈도우즈 GUI 환경을 이용한 자동차의 주행성능 측정.분석용 CAT 시스템의 개발)

  • 양희구;김석일;김동룡;김건상
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.5 no.4
    • /
    • pp.21-28
    • /
    • 1997
  • The vehicle handling performances have a close relation with the driver's safety. And the CAT(Computer aided testing) system has been introduced as a powerful tool for improving the handling performances. In this study, a CAT system for effectively measuring and analysing the handling performances is developed based on the windows GUI(Graphic user interface) environment. Especially, in order to derive a lot of significant handling performance parameters from a series of proving ground tests, the CAT system has various functions related to real time measurement, time domain analysis, frequency domain analysis, steady state analysis and so on.

  • PDF

Evaluation of Badge-Type Diffusive Sampler Performance for Measuring Indoor Formaldehyde

  • Yim, Bongbeen;Lee, Kyusung;Kim, Jooin;Hong, Hyunsu;Kim, Suntae
    • Environmental Engineering Research
    • /
    • v.18 no.3
    • /
    • pp.123-128
    • /
    • 2013
  • The purposes of this study were to determine the efficiency of using a badge-type diffusive sampler to measure formaldehyde concentrations indoors, and to evaluate the uncertainty associated with the use of data from a diffusive sampler. A diffusive sampler using 2,4-dinitrophenylhydrazine (DNPH) reagent was found to be a suitable tool for measuring the formaldehyde concentration in an indoor environment. The agreement between results of the diffusive sampler and DNPH cartridge were good, showing a correlation coefficient of 0.996. The sampling rate for the diffusive sampler was calculated to be 1.428 L $hr^{-1}$, with a standard deviation of 0.084 L $hr^{-1}$. It was found through analysis that the uncertainty associated with the sampling rate and the mass of the formaldehyde transported into the diffusive sampler by diffusion was the dominant contributor to the total.

Comparison of CARS CO and Temperature Measurements with Numerical Calculation for Methane/Air Premixed Flames (메탄/공기 예혼합화염에서 CARS를 이용한 CO 농도 및 온도측정과 수치해석 결과의 비교)

  • 강경태;정석호;박승남
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.5
    • /
    • pp.1333-1339
    • /
    • 1995
  • Recently developed technique of measuring minor species concentration by using the modulation dip in broadband CARS has been applied to the flame structure study of methane/air premixed flames in a counterflow. This method used the modulation dip from the cold band CO Q-branch resonant signal superimposed on the nonresonant background. The measured CO concentration profile in a symmetric and unsymmetric methane/air premixed flames together with the velocity and temperature by using LDV and CARS have been compared with the numerical results adopting detailed chemistry modeling. The results show that there is a satisfactory agreement between the experimental data and numerical results for velocities, temperatures and CO concentrations. And the modulation dip technique of measuring minor species, such as CO is a viable tool for a quantitative measurement in a flame.

A Study on the Measurement for Straightness and Orhogonality Using CT Method (CT 법을 이용한 진직도 및 직각도 측정에 관한 연구)

  • 이승수;김민주;박정보;전언찬
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.11 no.1
    • /
    • pp.83-90
    • /
    • 2002
  • As high-precision parts are needed with manufacturing techniques improved. the demand of high-precision machine tools has been increasing They are made to developed the precision measuring skill to maintenance the accuracy of themselves as a matter or course We one paper measured straightness and orthogonality of the square to verify that it is possible for CT(circular test) method by 2-dimensional probe and the square to measure orthogonality Furthemore we compared the result of the study with the computer simulation's to prove its possibility and made an improvement of measuring method.

Precision enhancement for a CCD/LSB type shape measuring system (CCD/LSB 방식의 형상측정시스템의 정밀도 향상 방법)

  • 유주상;정규원
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2001.04a
    • /
    • pp.137-142
    • /
    • 2001
  • Since recent production system becomes that of the small quantity, large volume with high quality production, accurate and high speed inspection system is required. In such situation, noncontact 3D measurement system which utilized CCD cameras is useful technique in terms of system cost, speed of data acquisition, measuring accuracy and application. However, it has low accuracy compared with contact 3D measurement system because of the camera distortion, non uniformity of laser distribution and so on. For those reasons, in this paper precision enhancement method is studied considering radial camera distortion, and laser distribution. A distortion correction method is applied even to the standard lens. The laser slit beam trajectory is determined by 3 method: based of the Gaussian function signal approximation, the median method, the center of gravity method and the peak point of the Gaussian function method.

  • PDF

Evaluation of fracture toughness of dynamic interlaminar for CFRP laminate plates inserted interleaf (인터리브가 삽입된 CFRP 적층판의 인성평가)

  • 김지훈;강태식;한길영;김재열;심재기
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.10 no.4
    • /
    • pp.91-96
    • /
    • 2001
  • In this paper, an investigation was performed on the dynamic interlaminar fracture toughness of CFRP(carbon filber rein-forcement plastics). Specimens used in this experiments are CF/PEEK laminated plates. In this experiments, Split Hopkin-sons Bar(SHPE) tes was apply to dynamic and notched flexure test. The model II fracture toughness of each unidirectional CFRP was estimated by the analyzed deflection of the specimen and J-integral with the measured impulsive load and reac-tions at the supported points. As an experimental results the vibration amplitude of [$0^{\circ}_10 /F_4 0^{\circ}_10 $] j-aminates appear more than that of [$0^{\circ}_10 /F_2 0^{\circ}_10 $ laminates for the j-integral and displacement velocity at a measuring point. Also, it is thought that the dynamic fracture toughness of two kind specimen(CF/PEEK) with the crease of displacement velocity becomes great at a measuring point with in the range of measurement.

  • PDF

Linearity study for the field coil current and the load of eddy current dynamometer (Eddy current 동력계의 부하와 와전류의 직진성 관련 연구)

  • 문병수
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2000.04a
    • /
    • pp.66-72
    • /
    • 2000
  • Commercial eddy current dynamometers control the torque of ratating body (poer supply machine) with the field coil current being operated as a braking force. In this paper, we studied about the relation between the field coil current and the torque load of eddy current dynamometer. By the torque measuring analysis of eddy current dynamometer, it is linear relation between the brake force measured from the torque meter (e.g. load cell, strain gage or spring balance etc.) which is installed at the case of dynamometer and the multiply of shaft rpm by the square of field coil current (N$\times$Ia2). To prove the relation, it was experimented and showed that the torque operated by the rotating body can be measured with the shaft rpm and the field coil current of eddy current dynamometer. This result shows a possibility that eddy current dynamometer can measures the torque of rotating body without special torque measuring devices.

  • PDF

A Study on the Contact Error of Dial Gauge (DIAL GAUGE 측정자의 접촉오차에 관한 연구)

  • 강석수
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2000.04a
    • /
    • pp.138-143
    • /
    • 2000
  • In order to maintain the faith and accuracy with precision of machinery, it is recently required the precise comprehension about approach which is appeared in the contact area between two bodies, because approach affects the static stiffness and dynamic characteristic of contact area. This study applied H. Hertz's circle contact area theory as much lower measuring force. It is measured approach influenced by various factors which were concerned with contact errors like material, form of two bodies, using calibration tester. As a result, the following conclusion can be obtained. 1) The approach appears greatly in order of carbon steel(SM20C), aluminum(A601-T6) and high density polyethylene(5305E) 2) The approach appears in order of concave, disc, convex form, in the ration of contact area size by the difference of curvature.

  • PDF