• Title/Summary/Keyword: Measuring sensor

Search Result 1,964, Processing Time 0.032 seconds

Development of Effective Measurement Method for Burr Geometry (효율적인 버 형상 측정방법 개발)

  • 고성림;김원섭
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.20 no.6
    • /
    • pp.81-87
    • /
    • 2003
  • Triangulation method, conoscopic holography method and interferometry method are analyzed for effective measurement of micro burr geometry, which is formed in micro drilling. To select proper sensor, the cross section of a cylinder with 0.5mm diameter is measured and the result shows that conoscopic holography method is effective for measuring highly inclined surface in cylinder. Burrs with 1.0mm and 30${\mu}{\textrm}{m}$ height are measured by three suggested methods. As a result, the conoscopic holography method is proved to be most proper in measuring burr geometry. Burr measurement system is developed, which consists of conoscopic laser sensor, X-Y table, controller and burr measurement program. Burrs can be measured automatically and the result is displayed in 3D shape

Filter Test for Detecting Partial Discharge in XLPE Cable (XLPE 케이블의 PD 검출 필터 시험)

  • Kim, Dae-Yeol;Yun, Ju-Ho;Choi, Yong-Sung;Park, Dae-Hee;Lee, Kyung-Sup
    • Proceedings of the KIEE Conference
    • /
    • 2007.04b
    • /
    • pp.72-74
    • /
    • 2007
  • Due to a variable noises in the field underground lines, clear technology of noises is very important in the diagnosis technology of partial discharge. Therefore we progressed filter test to improve the measuring test of partial discharge in a field. We applied to field test after making W-LC filter for partial discharge measurement, and then designed experimental environment such as underground distribution lines of field. Measuring sensor for test was UHF sensor. And we analysed those using the Lemke Probe and oscilloscope (TDS-3054, Tektronix). Finally, we obtained excellent data of noise decrement in the joint box of 22.9[kV] distribution lines from above experiment.

  • PDF

A Study on the development of gas metering valve system (가스 계량 밸브 시스템의 개발에 관한 연구)

  • Choi, Young-Gyu
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.7 no.4
    • /
    • pp.200-204
    • /
    • 2014
  • LPG is used in the home would have to depend on the provider, because there is no method for measuring the capacitance. In addition, by measuring the gas capacities can not be known because of the LPG gas replacement time and requires an alarm for replacement. In this study, and that the gas capacities to the trusted user and the supplier, in order to know when it is time to change to LPG gas by applying a Hall effect sensor developed a gas capacities measurement the valve system.

Filter Test for Detecting Partial Discharge in 22.9kV XLPE Cable (22.9kV XLPE 케이블 PD 검출용 필터 시험)

  • Lee, Yong-Sung;Kim, Jung-Yoon;Kim, Seok-Jung;Lee, Kyoung-Yong;Choi, Yong-Sung;Park, Dae-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2005.07c
    • /
    • pp.2277-2279
    • /
    • 2005
  • Due to a variable noises in the field underground lines, clear technology of noises is very important in the diagnosis technology of partial discharge. Therefore we progressed filter test to improve the measuring test of partial discharge in a field. We applied to field test after making W-LC filter for partial discharge measurement, and then designed experimental environment such as under-ground distribution lines of field. Measuring sensor for test was UHF sensor. And we analysed those using the Lemke Probe and oscilloscope (TDS-3054, Tektronix). Finally, we obtained excellent data of noise decrement in the joint box of 22.9[kV] distribution lines from above experiment.

  • PDF

Preparation of a Semi-Conductive Thin Film Sensor for Measuring Occlusal Force

  • Yu, Siwon;Kim, Nari;Lee, Youngjin
    • Journal of Sensor Science and Technology
    • /
    • v.24 no.2
    • /
    • pp.88-92
    • /
    • 2015
  • In order to study the semi-conductive characteristics of carbon black-filled ethylene-propylene-diene monomer (EPDM) composite film, which is used for measuring occlusal force, composite samples with volume ratios of carbon black to EPDM ranging from 30% to 70% were prepared. The process of making a composite film consists of two steps, which involve the preparation of a slurry composition and the fabrication of a thin film using solution casting and a lamination process. To prepare the slurry composition, we dispersed carbon black nanoparticles into an organic solvent before mixing with an EPDM solution in toluene. The mechanical and electrical properties of the resulting carbon black-filled EPDM film were then investigated, and the results showed that the electrical resistance of a film decreases with the increase in the carbon black content. Furthermore, improved elastic recovery was observed after cross-linking the EPDM.

On-line Monitoring of a Glucose Concentration on a Fermentation Process of Wine for an Automatic Control of a Fermentation Process (발효공정 자동제어를 위한 포도주 발효 중 포도당 농도 온라인 측정)

  • Song, Dae-Bin
    • Journal of Biosystems Engineering
    • /
    • v.33 no.4
    • /
    • pp.276-281
    • /
    • 2008
  • A flow injection analysis method (FIA), which analyzes sample conditions after injecting a sample and reagents into a continuous stream, are recognized as the most adequate analyzing method according to the increase of sampling frequency, the decrease of measuring time and the diversity of measuring targets. Specially, the FIA is considered to be used effectively for the control of a fermentation process to produce fermentation food and useful microbial production by activation of a fermentation industry for development of biological materials. In this study, a flow injection analysis sensor unit was developed for on-line monitoring of the fermentation process. The performance was verified by on-line measuring the concentration of glucose of the fermentation process of wine. The glucose concentrations of the samples were measured every 12 hours during the whole fermentation process and compared with those by a HPLC. The concentration relative errors of glucose on the fermentation process of wine showed below 30% within 72 hours and over 50% after the 72 hours. The sensor unit had potential to on-line monitoring of the fermentation process but some problems to overcome for an commercial application.

Reliability Evaluation System of Hot Plate for PR Baking (Hot Plate 신뢰성 시험.평가장비 개발)

  • 송준엽;송창규;노승국;박화영
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2001.04a
    • /
    • pp.566-569
    • /
    • 2001
  • Hot Plate is the major unit that it used to remove damp of wafer surface, to strength adhesion of photoresist(PR) and to bake coated PR in FAB process of semiconductor. It is necessary to guarantee the performance of Hot Plate(HP). Therefore, in this study designed and developed the reliability system of HP to measure and estimated thermal uniformity and flatness in temperature setting amplitude $0~250^{\circ}C$. We developed the techniques that measures and analyzes thermal uniformity using infrared thermal vision, and compensates measuring error of flatness using laser displacement sensor. For measuring flatness, we specially makes the measurement stage of 3 axes which adopts the precision encoder. The allowable error of measuring technique is less than thermal uniformity, $\pm 0.1^{\circ}C$ and flatness, $\pm 1mm$. It is expected that the developed system can measure from $\Phi$210(wafer 8") to $\Phi$356(wafer 12") and also can be used in performance test of the Cool Plate and industrial heater, etc.

  • PDF

Development of Measurement System for Deflection of the Large-Size FPD (대면적 평판 디스플레이용 유리기판의 처짐 측정장치 개발)

  • Kim, Sook-Han;Kim, Tae-Sik;Lee, Eung-Ki
    • Journal of the Semiconductor & Display Technology
    • /
    • v.7 no.4
    • /
    • pp.1-5
    • /
    • 2008
  • There is a need to enlarge the mother glass substrate in OLED to raise its productivity and to realize OLED TV. On the other hand, some difficulties may arise regarding the deflection of a large glass substrate during its handling operation due to its thinness $(0.5\sim0.7t)$, which is not even enough to allow it to stand its own mass. This thesis proposes a conceptual plan for the application of the clamping- and bending-end conditions to the glass substrate handler. To verify proposed plan, the non-contact 3 dimensional measuring instrument is developed. The composition of the 3 dimensional measuring instrument measures shape of the product using X-Y stage robot and laser distance sensor. X-Y stage robot and laser distance sensor are controlled by LabVIEW language. To calibrate measuring instrument, the direction conversion of the Euler angle was used. In order to confirm deflection of the glass substrate, the experiment was carried out at the bending end boundary condition and the proposed effect was verified.

  • PDF

Implementation of Low-Cost Baby Monitor for deaf and Visually Impaired Person (시각·청각장애인을 위한 저비용 베이비 모니터 구현)

  • Oh, Pa-Do;Kim, Hyeon-Hui;Lee, Boo-Hyung
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.10a
    • /
    • pp.159-162
    • /
    • 2015
  • In this paper, implement a baby monitor using the arduino for deaf and Visually Impaired. The proposed baby monitors are divided into measuring part & transmit part and linked with the application. The measuring part consists of a sound volume sensor, a transmit part consists of a bluetooth module. The measuring part and transmit part are controlled by the Arduino board. Measure the value of the sound by the sound sensor and delivers value to the arduino board. The measured value is sent to the application by the bluetooth module of transmit part. The application determines the received value and control the smart phone, and outputs the light from the sound and vibration for the value. It showed that the proposed baby monitor and an application is correctly operating in accordance with the value.

  • PDF

A Study of Optical Properties of Intraocular Lenses and of Measurement of the Index of Reflection for an Unknown Liquid

  • Joo, Won Don;Jung, Mee Suk
    • Journal of the Optical Society of Korea
    • /
    • v.16 no.3
    • /
    • pp.236-242
    • /
    • 2012
  • In general, such methods as interferometers or wavefront sensors are commonly used for testing of an optical system and optical components. In these cases, the surrounding environments are unlikely to affect the measurements. On the other hand, intraocular lenses of hydrophilic materials with special properties experience a certain difficulty in testing the optical properties. An intraocular lens is dried in the air, which causes deformation and changes the optical characteristics such as index of refraction and thickness. Thus, it is hard to measure the optical characteristics of an intraocular lens by using common methods. In this study, a special structure is used for measuring of the transmission wavefront aberration and effective focal length of an intraocular lens of hydrophilic materials by using a Shark-Hartmann sensor among the various measuring methods. As an application of this measuring method, this study shows a simple method to measure the index of refraction of unknown liquids with a plano-convex lens with a well known index of refraction. Also, this method is used to measure the optical properties of a plano-convex such as index of refraction and curvature by using a liquid with a well known index of refraction.