• Title/Summary/Keyword: Measuring methods

검색결과 4,453건 처리시간 0.039초

대용 식품의 텍스츄어 특성 및 그의 측정 방법 (Desired Textures of Food Analogs and Methods of Measuring Their Textural Properties)

  • 말콤C.부르네
    • 한국식품과학회지
    • /
    • 제7권3호
    • /
    • pp.168-180
    • /
    • 1975
  • Analogs and extenders should have mouthfeel and chewing characteristics that are similar to the food they are replacing or extending. Instrumental methods can measure some of the physical properties that constitute 'texture' but only sensory methods can provide a complete description and quantification of the textural properties of a food. Instrumental methods and sensory methods for measuring texture are reviewed.

  • PDF

Leak Evaluation for Power Plant Valve Using Multi-Measuring Method

  • Lee, Sang-Guk;Park, Jong-Hyuck;Kim, Young-Bum
    • 비파괴검사학회지
    • /
    • 제28권6호
    • /
    • pp.469-476
    • /
    • 2008
  • Condition based maintenance(CBM) for the preventive diagnosis of important equipments related to safety or accident in power plant is essential by using the suitable methods based on actual power plant conditions. To improve the reliability and accuracy of the measured value at the minute leak situation, and also to monitor continuously internal leak condition of power plant valve, the development of a diagnosis and monitoring technique using multi-measuring method should be performed urgently. This study was conducted to estimate the feasibility of multi-measuring method using three different methods such as acoustic emission(AE) method, thermal image measurement and temperature difference$({\Delta}T)$ measurement that are applicable to internal leak diagnosis for the power plant valve. From the experimental results, it was suggested that the multi-measuring method could be an effective way to precisely diagnose and evaluate internal leak situation of valve.

BRDF 측정 및 표현을 위한 프레임워크 (BRDF Measurement and Representation Framework)

  • 김해동;최병태;박태용
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2003년도 컴퓨터소사이어티 추계학술대회논문집
    • /
    • pp.91-94
    • /
    • 2003
  • In this paper, we present a simple framework to measure BRDF(Bidirectional Reflectance Distribution Function) values of objects and to render them using the values more realistically. There are lots of BRDF measurement methods, but the methods have been separated from the effective rendering of the values. Therefore, we suggest the framework which includes the BRDF measurement methods of objects and the effective rendering methods of the measured BRDF data. Before measuring the BRDFs, we do light sources analysis, camera calibration and display device characterization. After measuring them, we apply them to the characterized display device for rendering effectively and realistically.

  • PDF

토양수분 측정방법 비교 연구 -중성자법과 TDR법을 중심으로- (Comparative Study of Soil Moisture Measurement Methods)

  • 장민원;정하우;최진용
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 1998년도 학술발표회 발표논문집
    • /
    • pp.65-70
    • /
    • 1998
  • Soil moisture measuring is important for irrigation scheduling of upland crops, estimation of evapotranspiration, and hydrologic modeling. Hence, the comparative study was implemented for the soil moisture measuring instruments, Neutron probe and TDR with soil sampling methods, and the result was represented.

  • PDF

채광·조명설비시스템의 광학 분석을 위한 이미지 프로세싱 기법에 관한 연구 (Methodological study on the High Dynamic Range Imaging Processing)

  • 임홍수;김곤
    • KIEAE Journal
    • /
    • 제10권4호
    • /
    • pp.3-8
    • /
    • 2010
  • Recently, various daylight evaluation methods for visual environment have been developed; simulation analysis methods, numerical calculation, and data monitoring methods. However, it is impossible for simulation analysis to make real scenes and visualize real images exactly. Also, a numerical calculation is considered as an out of date and time-consuming mean. Therefore, for acquisition of accurate results, many studies often use the monitoring data methods. Especially, most studies regarding discomfort glare are evaluated by measuring the physical quantity of luminance through traditional measuring Minolta Luminance meters as an instrument. But, this method has a difficulty in measuring several points at the same time because of the limitation of spaces and time when mapping. So, this study focused on the potential usefulness of High Dynamic Range photography technique as a luminance mapping tool. In order to evaluate the accuracy of proposed programs such as webHDR, Photomatix and PHOTOLUX, this paper has conducted an experiment by using Canon EOS 5D and NICON Coolpix8400 digital camera.

New Test Methods of Retention and Drainage Using Multi-channel Turbidimeter and Balance Recorder

  • Son, Dong-Jin;Kim, Bong-Yong
    • 펄프종이기술
    • /
    • 제38권5호
    • /
    • pp.31-37
    • /
    • 2006
  • This study was performed to find effective measuring methods of retention and drainage by comparing traditional measuring methods of Britt jar, Canadian standard freeness tester methods and recently developed RDA-HSF with multi-channel turbidimeter method. At the result, Multi-channel turbidimeter method was useful to measure retention and efficiency of multiple chemical dosing system. A system CSF equipped with the balance recorder was also useful to obtain dynamic drainage information including initial drainage rate and final drainage amount. Therefore, we consider these new measuring systems would be helpful to advance retention and drainage technology.

반도체부품 생산공정 자원의 부하 측정방법 비교분석 사례연구 (A Case Study of Comparing the Measuring Methods for Workloads of Resources in a Manufacturing Processes of Semiconductor-Parts)

  • 김동수;문덕희
    • 한국시뮬레이션학회논문지
    • /
    • 제20권3호
    • /
    • pp.49-58
    • /
    • 2011
  • 설비나 작업자에 대한 부하효율은 제조공장에서 생산용량계획을 수립하는데 중요한 정보다. 즉 공장에서 신제품을 개발하거나, 생산량을 증가시킬 경우, 새로운 투자계획을 수립할 경우에도 항상 설비나 작업자에 대한 부하효율을 검토한다. 이러한 부하효율을 추정하기 위해서 다양한 측정방법이 사용된다. 본 본문에서는 설문조사, 순간관측법, 동영상 촬영을 이용한 미세동작연구방법, ERP시스템에서 자료를 취득하는 방법, 시뮬레이션방법 등 다양한 측정방법의 정확성에 대해 실제 사례를 이용해 비교분석하였다. 본 사례연구는 리드프레임이나 패키징용 부품을 생산하는 국내 반도체부품 생산공장을 대상으로 수행하였다.

역대(歷代) 약물(藥物) 비표준(非標準) 계량단위(計量單位)의 고찰(考察) (A Historical Study of Non-standard Weight and Measuring Units)

  • 윤성중;문영춘;김지훈;정기은;김윤경
    • 대한한의학방제학회지
    • /
    • 제24권4호
    • /
    • pp.335-351
    • /
    • 2016
  • Objective : This study was done to clarify ambiguous non-standard weight and measuring units in medical classics. Methods : Using medical classics and research dissertations, we studied the basic definitions of weight and measuring units and the types of non-standard weight and measuring units. We compared non-standard weight and measuring units in the reference literatures, to determine the dose of herbs in the prescriptions. Results : There are three types of units in non-standard weight and measuring units. These are 'Quantity measuring unit', 'Resembrance measuring unit', and 'Eye measuring unit'. And we found historical efforts and progresses for proper ways to convert non-standard weight and measuring units to standard weight and measuring units. Conclusions : This research will be the basic data for the standardization of prescriptions. Additional study was still required for precise weighing and measuring in Korean medicine and pharmacy.

엉덩정강근막띠의 길이 평가를 위한 세 가지 측정방법들의 신뢰도 비교 (Reliability of Three Methods for Measuring Length of Iliotibial Tract)

  • 김문환;윤성준;원종혁
    • 한국전문물리치료학회지
    • /
    • 제21권3호
    • /
    • pp.20-27
    • /
    • 2014
  • The purpose of this study was to compare the intra-rater and inter-rater reliability of three methods for measuring iliotibial tract length in 40 knees of 20 subjects. The measurements were performed by two examiners and one assistant. The length of the iliotibial tract was measured using three methods: the first used a modified Ober test with an inclinometer, the second used a modified Ober test with a marker, and the third used active adduction test with a marker in the supine position. Each examiner used the three methods in two sessions. For the first method, the inclinometer value was recorded manually. For the second and third methods, Image J analysis software was used to analyze the photographs taken. The intra-rater and inter-rater reliability of the measured value was assessed by means of intra-class correlation coefficients [ICC (3,1)] and the standard error of measurement. The intra-rater reliabilities of the three methods were excellent (ICC=.97, .95, and .94, respectively), and the inter-rater reliabilities of the first and second methods were fair to good (ICC=.64 and .65, respectively). The inter-rater reliability of the third method was excellent (ICC=.88). Our results suggest that the active adduction test is an objective and qualitative measurement method for measuring iliotibial tract length. We recommend that the active adduction test be used for measuring iliotibial tract length in the clinical setting.