• 제목/요약/키워드: Measuring head

검색결과 411건 처리시간 0.025초

A Comparative Study of Korean and French Vowel Systems -An Experimental Phonetic and Phonological Perspective-

  • Kim, Seon-Jung;Lee, Eun-Yung
    • 음성과학
    • /
    • 제8권1호
    • /
    • pp.53-66
    • /
    • 2001
  • This paper aims to investigate the acoustic characteristics of the vowels attested in Korean and French and to seek a way of understanding them from a phonological point of view. We first compare the two vowel systems by measuring the actual frequencies of the formants using CSL. It is shown that the first and second formants vary in wider range in French compared to Korean. In order to understand the two vowel systems from a phonological point of view, we apply the theory of Licensing Constraints, proposed and developed by Kaye (1994), and Charette and Kaye (1994). We propose the licensing constraints placed upon the vowels both in Korean and French. For Korean, we propose the licensing constraints such that both elements I and U must be heads. For French, we claim the following licensing constraints: U in a headed expression must be head, A cannot be head, and Nothing can only license an expression A in it.

  • PDF

대퇴골 전염각 측정을 위한 수 작업 방법과 Image Viewer 방법과의 비교 연구 (Comparative Study for the Measurement of Fermoral Anteversion by Manual Method and Image Viewer)

  • 권대철;박범
    • 대한인간공학회지
    • /
    • 제20권3호
    • /
    • pp.27-35
    • /
    • 2001
  • The measurement of the fermoral anteversion is an important factor in the practice of orthopedic surgery. The anteversion is measured by means of the axis of head and neck of the femur. In this study. widely used computed tomography method of measuring anteversion was tested on femoral necks of patients. Measurement by the manual method and image viewer of computed tomography to determine the anteversion of femoral head were carried out on both femurs. In January and February 2001, 30 patients 3 to 6 years of age were randomly selected from Seoul National University Hospital. the purpose of this paper was to introduce a new method to measure femoral anteversion angle utilizing image viewer program. This new method was more accurate and convenient than the conventional manual method. No significant difference was observed between the manual method and the image viewer measurement of femoral anteversion. In conclusion, image viewer program was statistically more reliable in determining the angle of the fermoral anteversion.

  • PDF

영상 처리 방법을 이용한 후각 상피 세포의 섬모 운동 특성 분석에 관한 연구 (A Study on the Analysis of Mucociliary Beat Frequency Using Image Processing)

  • 이원진;박광석;민양기;성명훈
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1996년도 춘계학술대회
    • /
    • pp.111-114
    • /
    • 1996
  • Mucociliary transport is one of the essential defensive functions of the airway mucosa. In this paper, the objective and quantitative method of measuring CBF(Ciliary Beat Frequency) was developed based on the image processing method. Microscopic ciliary images are acquired through image processing board inside PC, and data necessary for the FFT(Fast Fourier Transform) analysis are extracted. By means of FFT analysis, maximum peak frequencies are found in each divided block of a whole acquired image. Finally using these frequencies, we compose a frequency map showing the spatial distribution of CBF's.

  • PDF

로렌츠 힘을 이용한 MHD(Magnetohydrodynamic) 마이크로펌프 (MHD (Magnetohydrodynamic) Micropump Using Lorentz Force)

  • 장재성;이승섭
    • 한국정밀공학회지
    • /
    • 제15권11호
    • /
    • pp.93-99
    • /
    • 1998
  • We present a novel micropump of which pumping mechanism is based upon MHD (Magnetohydrodynamic) principle. The MHD micropump uses Lorentz force as pumping source. In the MHD micropump, Lorentz force is applied into initially stagnant conducting fluid to drive it in magnetic and electric field to flow in both directions. The performance of the MHD micropump is obtained by measuring the pressure head difference and flow rate as applied voltage changes from 10 to 60 V DC at 0.19 and 0.44 Tesla. The pressure head difference is 18 mm at 38 mA and the flow rate is 63 ${\mu}{\ell}$ /min at 1.8 mA when the inside diameter of inlet/outlet tube is 2 mm and the magnetic flux density is 0.44 Tesla.

  • PDF

폴리우레탄 발포 노즐 형상이 혼합 성능에 미치는 영향 (Influences of Polyurethane Nozzle Shape on Mixing Efficiency)

  • 김도연;이태경;정해도;김형재
    • 한국정밀공학회지
    • /
    • 제33권1호
    • /
    • pp.31-35
    • /
    • 2016
  • For reaction injection molding (RIM) polyurethane was mixed in the mixing head by impingement mixing, injected into the mold, and cured quickly, as soon as the mold is filled. The shape of the nozzle in the mixing head is critical to improve the quality of polyurethane. To achieve homogeneous mixing, an intensive turbulence energy in the mixing nozzle is essential. In this study, a mixing nozzle for RIM was designed, and mixing efficiency was investigated based on experiment. Experiments were conducted with different combinations of nozzle tips and exit diameter to measure the mixing efficiency by measuring jet force and investigating mixing image with high speed camera. Jet force increased gradually and reaches steady state conditions. The jet force depended on shape of nozzle tip and outlet sizes. These results suggest that optimized nozzle configurations are necessary for high efficiency mixing with RIM.

긴장성 두통에 대한 두개경부 운동의 효과 (The Effect of Craniocervical Exercise on Tension-Type Headache)

  • 채윤원;이현민
    • The Journal of Korean Physical Therapy
    • /
    • 제21권4호
    • /
    • pp.9-16
    • /
    • 2009
  • Purpose: This study was done to assess the effect of changes in forward head posture (FHP), neck mobility and headache clinical parameters on episodic tension-type headache (ETTH) and chronic tension-type headache (CTTH) who did craniocervial exercises. Methods: Twelve CTTH subjects and twelve ETTH subjects were studied. Side-view pictures of subjects were taken in both sitting and standing positions, in order to assess FHP by measuring the craniovertebral angle. Cervical range of motion (CROM) was employed to measure cervical mobility. A headache diary was kept to assess headache intensity, frequency, and duration. All subjects did three types of craniocervical exercise over 8 weeks. Measurements were done at pre-treatment, and at 4 and 8 weeks post-treatment. Results: Forward head posture and headache-related clinical parameters showed a significant improvement after craniocervical exercise (p<0.05). Flexion/extension and left/right rotation of CROM was significantly increased after the intervention (p<0.05), whereas changes in left/right bending did not reach statistical significance. Conclusion: This study indicates that craniocervical exercise may be effective in the management of tension-type headache.

  • PDF

대학생에서의 만성 및 특발성 긴장성 두통이 두부전방자세와 경추가동범위에 미치는 영향 (The Effect of Forward Head Posture and Cervical ROM on Chronic and Episodic Tension-Type Headache in University Students)

  • 채윤원
    • The Journal of Korean Physical Therapy
    • /
    • 제21권2호
    • /
    • pp.71-77
    • /
    • 2009
  • Purpose: This study assessed the differences in the forward head posture (FHP), cervical range of motion, and headache clinical parameters in episodic tension-type headache (ETTH) subjects, chronic tension-type headache (CTTH) subjects, and healthy controls (university students). Methods: Fifteen CTTH subjects, 15 ETTH subjects and 15 controls without headache were examined. Side-view images of each group were taken in both the sitting and standing positions, in order to assess the FHP by measuring the craniovertebral angle. The CROM was used to measure the cervical range of motion. A headache diary was kept for 4 weeks to assess the headache intensity, frequency, and duration. Results: The craniovertebral angle was smaller, ie, there was a greater FHP, in the CTTH and ETTH subjects than in the healthy controls in both the sitting and standing positions (p<0.05). The CTTH and ETTH subjects showed a lower cervical range of motion than the healthy controls in the total range of motion as well as in the half-cycles (p<0.05). Conclusion: The increased FHP and decreased cervical range of motion might be a contributing factor in the initiation of tension-type headache.

  • PDF

실내 충격소음 측정시스템 구현에 관한 연구 (A study of the measurement systems implementation for the interior impulse noise)

  • 송기혁;정성학
    • 한국컴퓨터정보학회논문지
    • /
    • 제19권6호
    • /
    • pp.93-100
    • /
    • 2014
  • 본 연구의 목적은170dB 이상의 고충격 소음원에서 실내 충격소음을 측정 평가 할 수 있는 측정시스템 구축 방법을 제안하는데 있다. 이러한 목적을 달성하기 위하여 실내충격소음 측정시스템용 시험장을 설계 및 구현하고, 충격소음 측정용 마이크로폰, Head & Torso Simulator, Ear Simulator를 구성하였다. 충격소음 측정 시 정확한 측정을 위하여 3가지 측정방법을 동시에 측정할 수 있도록 구현하였으며, 정확성과 신뢰성을 위하여 3가지의 실내충격소음 측정값을 상호 비교하였다. 3가지 측정방법에 따른 최대 음압레벨과 옥타브 밴드 결과를 비교 분석함으로써 실내 충격소음의 주파수 특성에 따른 차이점을 확인하였다. 이러한 결과는 반사파의 영향에 의한 것으로 판단된다. 이에, 시험장의 크기를 변형하면서 측정할 수 있도록 실내 충격소음 측정시스템을 구현하였다. 본 시스템 구현을 통하여, 충격 소음원의 특징분석과 해당 주파수별 스펙트럼의 반사파 영향들을 파악할 수 있을 것이며, 향후, 실내 충격소음에 대한 데이터 획득 및 분석을 위하여 유용하게 활용될 수 있을 것으로 판단된다.

비접촉식 센서를 사용한 형상 측정 연구 (A Study of Form Measurement using Noncontact Sensor)

  • 송정섭;황윤호;배종일;이만형
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1995년도 추계학술대회 논문집
    • /
    • pp.407-410
    • /
    • 1995
  • Many researches on measurement technology has been made and developed by various methods. Considering the measurement environment with cutting fluid, coolant and the like, contact type measurement methods are mostly used. But contact measurement method has measuring force and so the sensing head becomes worn. By these reasons, we considered sensors not influenced by the former fluid and so can acquire accrate measured values using error compensation due to temperature and vibration. For this purpose, eddy current sensors and Extended kalman Filter Algorithm for processing measured data has been used. In this paper, we present new technology that can be used for measuring workpiece with previous bad environment using direct method and comparison measurement method. We used cylindrical workpieces which were produced by grinding machine for the target.

  • PDF

병원간호조직의 특성을 측정하기 위한 도구개발 연구 (A Study for Development of a Tool Measuring Organizational Characteristics in Nursing)

  • 박성애;윤순녕
    • 대한간호학회지
    • /
    • 제16권3호
    • /
    • pp.31-37
    • /
    • 1986
  • The purpose of this study is to develop a ratio scale measuring organizational charateristics in nursing. 599 staff nurses working at 10 educational hospitals in Seoul were participated during the period from July 1 to July 31, 1985. Subjects were instructed to rate at one to five points likert type scale according to the level of positive characteristics affecting the nursing organizational effectiveness. As a result of factor analysis given to 50 items with varimax rotation and rearrangement on the asis of factor loading 0.3, there are 4 factors consisted of 33 items presented: factor 1 : leadership of head nurses and interaction(11 items) factor 2 : leadership of supervisors and top managers(11 items) factor 3 : interaction with supervisors(5 items) factor 4 : organizational climate(6 items) Reliability of the factors were tested by Cronbach's Alpha, and the result was α=0.67∼0.84 Further studies are needed to identify the relationship between this tool and the effectiveness of various organization in nursing.

  • PDF