혈청(血淸)$T_3$의 방사면역측정시(放射免疫測定時) 정도관리(精度管理)에 관(關)한 검토(檢討) (A Study on the Quality Control of the Radioimmunoassay Serum $T_3$(triiodothyronine))

  • 경광현;최영숙
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제5권1호
    • /
    • pp.55-62
    • /
    • 1982
  • Measurement of triiodothyronine($T_3$) concentration is useful for the diagnosic and treatment of thyroid gland diseases. Fundermental studies of measurement of $T_3$ concentration by radioimmunoassay were performed and values determined by commercially available kit, Coat-A-Count, Diagnostic Products Corporation. The optimal utilization of the radioimmunoassay in measuring $T_3$ concentrations is dependant not only on high quality performance of the assay, but also on their appropriate application to the clinical situation. These are several aspects that must be considered in every individual case. These include factors such as accurate pippeting in reagent preparation in the assay and through decanting to remove all visible moisture after incubation steps and so forth. In attempt to assess quality control of the radioimmunoassay of serum $T_3$, serum pools with high, medium, low $T_3$ concentrations were assayed for each of 5 samples. The results obtained with this study were as follow: 1. The coefficient of variation(C. V.) for the standard curve ranged between $0.2{\sim}3.5%$. 2. It was necessary that both incubation time and temperature should correctly be maintained all the in the assay performance. 3. The precison with the $T_3$ RIA procedure was good. 4. The measured values of serially diluted serum $T_3$ concentration with Ong/dl standard solution was proportional to the predicted values. However dilution curve of distilled water was not strait. 5. Calculated $T_3$ values of patient serum in normal group was $107.8{\pm}25.90ng/dl$ in male patient and $127.29{\pm}24.08ng/dl$ in female patient.

  • PDF

대형배출원에서의 수은 측정방법 비교 및 배출계수 개발에 관한 연구 (A Study on the Comparison of Measuring Methods and Development of Emssion Factor on Mercury from Large-Scale Emission Sources)

  • 김형천;김록호;김종현;임승영;강대일;홍지형;장기원
    • 한국대기환경학회지
    • /
    • 제32권2호
    • /
    • pp.184-192
    • /
    • 2016
  • Recently, studies on reducing mercury have been actively conducted worldwide, which include the current status of mercury emissions and mercury control technology. Among the control technology, Sorbent Trap measurement method has been aggressively developed due to its reliability, easiness in measurement and analysis. The purpose of this study is to evaluate the applicability of the new international measurement method; Sorbent Trap. For this, the study compared the Sorbent trap method (US EPA Method 30B) and the Korean Standard Method for Examination of Air (ES 01408.1) to evaluate their reliability, and developed mercury emission factors. As the result, the relative standard deviations (% RSD) of the two methods were 3.5~13.4% at Coal-fired Power Plants (CPP), 4.0~18.4% at Cement Kilns (CK), and 3.0~11.3% at Medical Waste Incinerators (MWI). The emissions factors were developed as 14.50 kg/ton at CPP, 45.10 kg/ton at CK, and 1,290.2 kg/ton at MWI.

HDTV를 위한 MPEG-4 비디오 디코딩 복잡도의 평가에 관한 연구 (A Study on the Evaluation of MPEG-4 Video Decoding Complexity for HDTV)

  • 안성렬;박원우
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2005년도 추계종합학술대회
    • /
    • pp.595-598
    • /
    • 2005
  • MPEG-4 Visual은 객체 기반의 동영상 압축 국제 표준으로서 멀티미디어 통신에서부터 HDTV에 이르는 광범위한 응용 분야를 지원하기 위해 설계되었다. MPEG-4 표준안은 디코더에서 처리 가능한 디코딩 복잡도를 제한하기 위해 3가지 Video Buffering Verifier 모델을 정의하고 있다. 그 중 VCV 모델은 비트스트림을 매크로블록 단위로 디코딩하는 처리 속도에 대한 제한을 정의하고 있으며, 경계와 비경계 MB 두 가지만을 구별하는 VCV와 B-VCV 모델이 있다. 본 논문에서는 최적화된 MPEG-4 Reference Software를 이용하여 직사각형 객체와 임의 형상 객체 그리고 HDTV 해상도를 지원하는 다양한 코딩 타입에 대한 MB 디코딩 시간을 측정하여 디코딩 복잡도를 평가하였다. 실험결과 디코딩 복잡도가 코딩 타입에 따라 많은 차이가 있으며 디코더에서 이용 가능한 리소스의 더욱 효율적인 사용이 가능함을 보여주었다.

  • PDF

비규격 초음파 탐상용 표준시험편의 사용안전성 평가 (Evaluation of Suitability of Non-Standardized Test Block for Ultrasonic Testing)

  • 권호영;임종호;강세선
    • 비파괴검사학회지
    • /
    • 제20권5호
    • /
    • pp.431-437
    • /
    • 2000
  • 표준시험편이란 재질, 형상, 치수 및 성능이 권위 있는 기관에 위해 검정된 국제적인 시험편을 말하며 이것은 탐상기의 특성시험 또는 감도조정, 시간축의 측정범위 조정에 사용된다. 그런데 이 표준시험편은 초음파탐상 결과에 아주 크게 영향을 미치는 하나의 변수로 ASTM 이나 JIS에서는 이들 표준시험편의 규격, 재질 및 성분 등을 엄격하게 규격화하고 있다. 그 이유는 이들 성질들이 감도와 분해능 및 재현성에 아주 큰 영향을 미치기 때문이다. 따라서 결함의 크기 및 치수를 정량화하고 재현성 있는 결과를 얻기 위해서는 엄격한 품질의 표준시험편이 요구되고 있다. 그러나 ASTM 또는 JIS등의 규격품들은 상당히 고가이며 시중에는 품질이 검증되지 않은 표준시험편들이 일부 사용되고 있는 실정에 있고 이들 시험편의 품질 및 사용 적합성을 재고하기 위하여 각종 규격에 비추어 보고, 규격품들과 비규격품의 각종 성질들을 비교하여 그 사용 안정성을 고찰하고자 하였다. 그 결과 비규격품들은 치수 및 성분에서 많은 문제점을 안고있으며 비규격품들을 검증없이 사용할 경우 피검물내의 결함의 위치나 크기 측정에 오차를 유발할 가능성을 확인하였다.

  • PDF

항암제 취급 간호사의 소변중 돌연변이 유발능과 자각증상 및 스트레스 (Urinary Mutagenicity, Physical Symptoms and Stress of Nurses Handling Anticancer Drugs)

  • 김봉임
    • 대한간호학회지
    • /
    • 제26권4호
    • /
    • pp.963-975
    • /
    • 1996
  • The purpose of this study was to call attention to the mental, physical and occupational hazards of the anticancer-drug-handling nurses by examining the possible urinary mutagenicity and measuring physical symptoms and stress level of the nurses exposed to anticancer drugs. The experimental group of the urinary mutagenicity assay was 14 nurses handling anticancer drugs at the medical wards of a hospital located in J city ; the control group was 12 psychiatric nurses of the same hospital. The test material was the nurses' 24hrs urine, which was concentrated by XAD-2 column chromatography. Tester strains were TA98(±S9 mix), TA100(±S9 mix), TA1535(±S9 mix) and TA1537(±S9 mix) ; Salmonella mammalian-microsomal test(Ames test) was employed for the urinary mutagenicity assay. The physical symptoms of which the nurses experienced were investigated through self-reports on open-questionnaires. The stress levels of the experimental group were measured by a stress measuring instrument developed by this author. Reliability of this instrument was found to be adequate (Cronbach's Alpha=0.9079). To ascertain the urinary mutagenicity of the experimental group, the mean and the standard deviation of the colonies of Tester strains appearing on the minimal plates were taken and compared differences between two groups. T-test was employed for the significance test of two groups. The physical symptoms were compared between the two groups through the analysis of the nurse' self-reports. The mean and standard deviation of the stress levels of the experimental group were also calculated and were examined through t-test. The results were summarized as follows : 1. The experimental group revealed significantly higher urinary mutagenicity both in the activation method test and the non-activation method test of the tester strains TA98, TA100 and TA1535. In the case of TA1537, two groups showed no difference in the non-activation method test, but the activation method revealed difference. 2. The physical symptoms were also much more frequently reported in the experimental group. 79.3% of the experimental group reported more than 1 kind of physical symptoms. On the other hand, 33.2% of the control group complained of 1 kind of physical symptom. The items with high symptom frequency were 'headache', 'itching sensation', 'corneal congestion', 'skin allergy' 3. The mean score of stress in the experimental group was 2.41(range 1-4). The experimental group showed the stress level above 2.0 in the 14 of 15 items in all. The highest stress level were recorded in the following items in the order quoted, 'I fear that anticancer drug may touch any part of body while handling it.', 'I feel concerned there is no protective countermeasure against anticancer drug handling.', 'I am afraid the anticancer drug handling may produce a fetal loss in the future'.

  • PDF

인증표준물질(CRM)을 이용한 방사면역측정법의 회수율 평가 (The Evaluation of Recovery Rate of Radioimmunoassay Using Certified Reference Material (CRM))

  • 최성희;신선영;임소희;홍미경;노경운;김진의
    • 핵의학기술
    • /
    • 제18권1호
    • /
    • pp.158-162
    • /
    • 2014
  • 공인된 기구에 의해 발급된 문서를 동반하는 인증표준물질은 특성값과 추정값의 신뢰정도를 나타내는 연계 불확도, 그리고 측정한 결과가 명시된 불확정 정도의 범위 내에서 국가 측정 또는 국제측정표준에 일치되도록 연속적으로 비교하고 교정하는 소급성을 제공하는 표준물질이다. 회수율 검사는 검체를 측정하여 얻은 값이 참값에서 얼마만큼 벗어났는지의 차이를 말하며 키트의 정확도를 반영한다. 이러한 인증표준물질을 가지고 회수율 검사를 하는 것은 체외 방사면역진단키트의 정확성을 보여주며 이러한 평가는 매우 중요하다. 인증표준물질은 NIBSC (National Institute for biological standard and control, United Kingdom)와 IRMM (Institute for Reference Materials and Measurements, Belgium)에서 구입하였고 검사 종목은 T4, Ferritin, PSA, Prolactin, AFP 그리고 TSH으로 총 6종목이다. T4는 IRMM의 표준물질을 사용하였고 나머지 종목은 NIBSC의 표준물질을 사용하였다. C-1 (저농도), C-2 (중농도), C-3 (고농도) 3 level로 제조하여 본원에서 사용하는 키트를 이용하여 4회 측정하였다. WHO 인증표준물질을 이용한 회수율 측정에서 T4 90%, Ferritin 88%, PSA 94%, Prolactin 99%, AFP 94%, TSH 93%였다. 6개 종목의 회수율 측정에서 88-99%로 양호한 결과를 보였다. 핵의학 체외진단키트의 정확성을 높이기 위해서 이 연구가 다른 검사실의 키트로 확장되어 검사가 되어야 하고 검사실간에도 교류가 필요하다. 인증표준물질을 이용한 체외진단키트의 회수율 평가가 앞으로도 지속되어야 하며 결과의 정확성은 환자의 만족의 증가로 이어질 것으로 기대한다.

  • PDF

인터넷통신 네트워크 품질특성 모니터 링을 위한 I-MR 관리도 활용체계 (An Application Scheme of I-MR Control Charts for Monitoring Internet Communication Network Quality Characteristics)

  • 박성민;박영준
    • 한국통신학회논문지
    • /
    • 제31권10B호
    • /
    • pp.936-944
    • /
    • 2006
  • 인터넷통신 서비스업체는, 최상위 기업경영 성과지표중 하나인 고객만족지수 향상을 위해, 전사적 품질경영을 전개하고 있다. 이와 관련, 고객만족지수와 연관성이 강한 기업내부 주요 인터넷통신 네트워크 품질특성에 대한 관리의 필요성이 제기되고 있다. 본 연구는, 인터넷통신 네트워크 품질특성 모니터 링을 위한 I-MR 관리도 활용체계를 제안한다. 네트워크 품질특성이 관리상태인지 모니터링하고, 네트워크 품질특성이 이상변동을 보이면, 이상원인 조사시점을 결정할 목적으로, 일정간격 연속 측정시점별; 1) 개별측정값 (individual measurements): 및 2) 연속 2개 개별측정값간 이동범위 (moving ranges)를 이용한 통계적 품질관리 체계인 I-MR 관리도를 활용한다. 사례분석에서는, 이상변동 발생시점에서 이상원인이 완전히 제거된다는 가정에 근거하여, 네트워크 품질특성의 실현가능한 치대 기대품질개선율이 계산된다. 인터넷통신 2개 Service A. B. Service별 7개 네트워크 품질특성 대상, 11개 측정지역의 기대품질개선율 평균, 표준편차를 분석, 1-MR 관리도 활용체계의 효과를 검토한다. 사례분석 결과, 기대품질개선율 범위는 다음과 같다. 1) Service A, (1) 평균 (0.31%-11.44%), (2) 표준편차 (9.82%-71.10%); 2) Service B, (1) 평균 (0.29%-17.64%), (2)표준편차 (8.05%-60.59%). 그러므로, 본 연구에서 설계·제안된 I-MR 관리도 활용체계는, 네트워크 품질특성의 평균 산포 개선 및 관리상태 유지에 효과적일 것으로 판단된다.

심박변이도(心搏變移度)의 측정시간(測定時間) 표준화(標準化) 연구(硏究) (A Study on Standardization of Measuring Time for Heart Rate Variability)

  • 김규태;박영재;박영배;오환섭
    • 대한한의진단학회지
    • /
    • 제10권2호
    • /
    • pp.88-103
    • /
    • 2006
  • Objectives : We performed this study to search the best time for HRV measuring and which index has the validity in a short term measuring. Methods : At first, three examiner measured electrocardiogram(ECG) of 5 people(4 male + 1 female) for 20 minutes in two times. and we devided ten regions (0-5, 5-10, 10-15, 15-20, 0-10, 0-15, 0-20, 5-15, 10-20, 5-20 minutes). After that we finded the HRV index for each regions. To evaluate the validity, we used Gage Repeatability and Reproducibility Study by MINITAB(ver. 13.20). If the '%Study Var' is under 30 and 'Number of Distinct Categories' is over 4, we could tell it has validity(repeatability and reproducibility). Results : 1) The region and HRV index has repeatability and reproducibility, was HF index in 10-15 minutes. The HF index in 15-20 minutes gained 27.41(%Study Var) and 5(Number of Distinct Categories). 2) The HF index in 10-15 minutes has the better reproducibility than repeatability. The value of measurement is under the control. There is consistency among the examiner. The distribution of measurement is not large. There is no interaction between examiner and each people. 3) The HF index in 10-15, 0-10, 0-15, 0-20, 10-20 minutes was not enough to gain the repeatability and reproducibility. But it had some meanings ; %Study Var, Number of Distinct Categories is 32.68, 4 for 10-15 minutes, 34.43, 4 for 0-10 minutes, 34.44, 4 for 0-15 minutes, 33.56, 4 for 0-20 minutes, 32.07, 4 for 10-20 minutes. Conclusions : This study shows the best index of measuring HRV is the HF index in 15-20 minutes. So, from now on we should measure the HRV for 20 minutes and extract the HF index in 15-20 minutes. It must be the standard for HRV measuring.

  • PDF

안경테 표준규격 실태에 관한 비교 연구 (A Comparative Study on the Current Status of Spectacle Frames Standards)

  • 유동식;김인수;손정식;성덕용
    • 한국안광학회지
    • /
    • 제14권1호
    • /
    • pp.9-15
    • /
    • 2009
  • 목적: 안경테에 있어 각국의 규격을 조사하고 한국산업규격(KS, Korean Industrial Standards)의 문제점과 개선점을 제시하는데 있다. 방법: 안경테와 관계된 한국산업규격, 국제규격(ISO, International Organization for Standardization), 일본공업규격(JIS, Japanese Industrial Standards), 독일국가규격(DIN, Deutsches Institut fur Normung) 및 미국표준국(ANSI, American National Standards Institute)규격의 최신판을 조사하였다. 비교 대상의 규격 명칭은 용어 및 어휘, 계측 시스템과 용어, 표시, 요구 사항 및 시험 방법, 형판, 나사 등으로 하였다. 결과: 용어와 어휘 규격에서 KS와 ANSI규격을 제외한 모든 규격은 영어(영국, 미국), 프랑스어, 러시아어, 일본어, 중국어, 독일어, 이태리어, 스페인어와 같은 9개국 언어로 되어 있었다. 측정 시스템과 용어에서는 KS와 ANSI규격을 제외하고 모든 규격에서 보충적 기호 및 정의를 부속서에 수록하고 있었다. 요구 사항 및 시험 방법에서 KS와 ANSI규격은 ISO규격의 개정판과 차이를 보였다. 형판 규격에서는 JIS와 ANSI규격을 제외하고 거의 같았다. 나사에 대한 KS규격은 JIS규격과 유사하였으며, 용접경첩과 니켈용출에 대한 기준은 KS규격에 없었다. 결론: ANSI규격을 제외한 모든 규격은 ISO규격을 따르는 경향이며, 특히 DIN규격은 ISO규격과 거의 전적으로 일치한다. 그러나 KS규격은 ISO규격 기준을 늦게 개정 또는 제정함으로써 시대에 뒤처져 있다. 따라서 안경테 품질관리나 안전검사에 도움이 되기 위해서 KS규격은 시차 없이 ISO규격과 동등한 내용으로 바꿔야 한다.

  • PDF

고감도 보급형 방사선 측정센서 모듈 개발 (Development of High-Sensitivity and Entry-Level Radiation Measuring Sensor Module)

  • 오승진;이주현;이승호
    • 전기전자학회논문지
    • /
    • 제26권3호
    • /
    • pp.510-514
    • /
    • 2022
  • 본 논문에서는 고감도 보급형 방사선 측정센서 모듈 개발을 제안한다. 제안하는 측정센서 모듈은 섬광체+광증배소자(SiPM) 센서 최적화 구조설계, 센서 드라이버용 증폭과 필터 및 제어회로 설계, 근거리 통신을 포함한 제어회로 설계, 센서 기구설계 및 제작, 시제품에 적용되는 GUI 개발 등으로 구성된다. 섬광체+광증배소자(SiPM) 센서 최적화 구조 설계는 센서 구조 설계를 위한 섬광체와 광증배소자(SiPM)의 특성을 확인하여 설계한다. 센서 드라이버용 증폭과 필터 및 제어회로 설계는 SiPM을 이용하여 섬광체로 방사선에 의해 발생하는 미세 섬광신호를 처리하도록 설계한다. 근거리 통신을 포함한 제어회로 설계는 근거리 무선통신 기능을 지원하기 위한 MCU 설계 및 유선 통신 지원을 통해 데이터 전송이 가능하도록 설계를 수행한다. 센서 기구설계 및 제작은 플라스틱 섬광체에서 발생한 미세 섬광 신호를 광증배소자(SiPM)에 전달하기 위해 플라스틱 섬광체 외부에 반사지(미러링)를 감싸 발생한 섬광이 반사되어 효율을 높이도록 설계한다. 시제품에 적용되는 GUI 개발은 각 화면에 따라 상단에 날짜와 시간을 표현하며, 측정단위 및 시간, 초, 알람 레벨, 통신상태, 배터리 용량 등이 표현되도록 한다. 제안된 시스템의 성능을 평가하기 위하여 공인시험기관에서 실험한 결과는 방사선량 측정 범위가 30𝜇Sv/h ~ 10mSv/h로 측정되어서, 현재 국내외에서 상용으로 판매되는 제품들 중에서 최고수준 범위와 같은 결과가 산출되었다. 또한, ±7.4%의 측정 불확도가 측정되어서 국제 표준인 ±15% 이하에서 정상동작 됨이 확인되었다