• Title/Summary/Keyword: Measuring Instrument

Search Result 849, Processing Time 0.028 seconds

The Development and Validation of Instrument for Measuring High School Students' STEM Career Motivation (고등학생들을 위한 이공계 진로동기 검사도구 개발 및 타당화)

  • Shin, Sein;Ha, Minsu;Lee, Jun-Ki
    • Journal of The Korean Association For Science Education
    • /
    • v.36 no.1
    • /
    • pp.75-86
    • /
    • 2016
  • The purpose of the present study is to develop and validate an instrument to assess STEM career motivation. We developed 32 items for 7 constructs (i.e. education experience, career value, academic self-efficacy, career self-efficacy, career interest, parents' support, and career motivation) on STEM career motivation based on Social Cognitive Career Theory (SCCT; Lent et al.,1994). 767 first year high school students participated in this study. The items were validated by Messick's framework (1995). In this study, we examined the validity of items in four aspects (i.e. content, substantive, structural and generalizability of validity). Methodologically, we used Rasch analysis, Exploratory factor analysis, confirmative factor analysis based on structural equation modelling. We confirmed that our instrument with 32 items as valid and reliable for measuring the STEM career motivation. In addition, we tested the STEM career motivation model based on SCCT. Our model explained the data well, suggesting that external factors (education experience and parents' support) and cognitive factors (perception of value, self-efficacy and interest) were significantly related to STEM career motivation.

The Effect of Emotional and Informational Support Intervention on Role Stress and Depression of Primary Family Caregivers Caring Stroke Patients (정서$\cdot$정보적 지지중재가 뇌졸중환자 가족원의 역할스트레스와 우울에 미치는 영향)

  • Park Young Sook;Park Hye Yeon
    • Journal of Korean Public Health Nursing
    • /
    • v.15 no.1
    • /
    • pp.96-110
    • /
    • 2001
  • The purpose of this study was to examine the effect of emotional and informational support intervention on role stress and depression of primary family caregivers caring stroke patients and to develop an effective nursing intervention method for them. This study selected the quasi-experiment, based on pre-test and post-test design of non-equivalent control group as a method of study. This study was conducted with 69 primary family caregivers caring stroke patients hospitalized in K and D hospitals in Daegu from August 20 to October 25, 2000. Out of them, 34 were placed in the experimental group, and 35 in the control group. The emotional and informational intervention program was divided into two aspects-emotional support and informational support- and executed three times, using prepared instruments and a guidebook. The intervention program consisted of the 1st intervention for one or one-half hour, the 2nd intervention for 30 minutes in two or three days after the 1st intervention. and the 3rd intervention for 30minutes in another two or three days after the 2nd intervention. Pre-test was carried out just before the 1st intervention, and the post-test was carried out right after the 3rd intervention, in order to collect data. The measuring instrument of role stress used was one that was modified to the role stress instrument of Yang Young-hee(1992) and the stress instrument of Choi Eun-sook (1992). The reliability was Cronbach's $\alpha=.8271$. The measuring instrument of depression used was one that was developed by Beck(1967) and standardized by Han Heung-moo et al(1986). The reliability was Cronbach's $\alpha=.8693$. Data were analyzed with percentage, mean, standard deviation, $x^2-test$, t-test and Paired t-test by using SPSS 9.0 program. The results of this study are summarized as follows: 1. Role stress score of the experimental group was revealed to be significantly lower than that of the control group 2. Depression score of the experimental group was revealed to be significantly lower than that of the control group Accordingly, the emotional and informational support intervention can be a way to reduce role stress and depression of primary family caregivers caring stroke patients.

  • PDF

Developing an Instrument to Evaluate Habitual Physical Activity Level of Elementary School-aged Children in Large Populations: A Preliminary Study (초등학생의 일상적 신체활동 측정 도구 개발을 위한 예비조사)

  • An, Ji-Yeon;Tak, Young-Ran
    • Korean Journal of Health Education and Promotion
    • /
    • v.27 no.5
    • /
    • pp.1-14
    • /
    • 2010
  • Objectives: This study is an explorative study for developing an instrument to measure habitual physical activity level of school-aged children. Methods: HPAQ-S consists of 41 items and a self-reported 5-day recall instrument designed to assess habitual physical activity level for school-aged children. For the validity and reliability test, a sample consisted of 28 children, aged 10-11 years old. Results: 41 question items showed an acceptable internal consistency (cronbach's alpha=.89). A significant positive correlation with the pedometer results (r=.69, p<.001) and with Borg's questionnaire (r=.76, p<.001) support the validity of HPAQ-S. Conclusion: HPAQ-S may be more useful for measuring habitual physical activity level of elementary school-aged children in large populations.

Development of a Appearance related Quality of Life Instrument for Korean Men and Investigation on Body Factors Influencing Appearance related Quality of Life (한국 남성들의 외모 관련 삶의 질 척도 개발 및 외모 관련 삶의 질에 영향을 미치는 신체요인 분석)

  • Yu, Haekyung;Ko, Sunyoung
    • Fashion & Textile Research Journal
    • /
    • v.18 no.5
    • /
    • pp.595-605
    • /
    • 2016
  • Importance of appearance as a means of self-expression and communication is increasing in modern society even for men. And appearance has become an significant factor affecting men's quality of life. The main objectives of this study were to develop an instrument measuring appearance related quality of life(ARQoL), and examine the body factors influencing ARQoL. The ARQoL instrument was developed from in-depth interviews, focus group interviews, and literature review, and were revised through two pre-tests. The final questionnaire was administered through on-line survey with 440 men. Quota sampling was used based on age and body size. The results indicated that high ARQoL group showed significantly higher satisfaction on body factors including face, weight, shape, body proportion, hair, and overall impression than low ARQoL group. There was no significant difference in terms of satisfaction on height between two groups. Factor analysis showed that ARQoL consists of four factors - physical, economic, psychological and social factors. Overall impression was the most important body factor affecting all four factors of ARQoL and has very strong influence especially on economic ARQoL. BMI was also a significant factor affecting physical, economic and social ARQoL except psychological factor of ARQoL. Face had significant influence only on economic and psychological aspects of ARQoL.

Analyses of the Studies on Cardiovascular Disease-Specific Quality of Life Reported in Korea (심혈관질환자 삶의 질에 대한 국내 연구논문 분석)

  • Lee, Eun-Hyun;Tak, Seung Jai;Song, Yeoungsuk
    • Korean Journal of Adult Nursing
    • /
    • v.17 no.3
    • /
    • pp.452-463
    • /
    • 2005
  • Purpose: The purpose of the present study was to analyze and evaluate prior studies published in Korea on the cardiovascular disease-related quality of life, in order to make recommendations for further research. Methods: A total of 15 studies were selected from four databases(Digital library of Research Information Center for Health, Korea Medical Database, MedRic, and National Assembly Library). The selected studies were analyzed according to criteria, such as diagnosis/operation, used instrument, generic/specific instrument, dimension of quality of life, translation/ back-translation, sample size, reliability, validity, responsiveness, number of items, type of scale, time required, and independent variables. Results: Of the 15 cardiovascular disease-related quality of life studies, approximately half of them were conducted with hypertension or ischemic heart disease patients. All studies asserted that the concept of quality of life had multidimensional attributes. With respect to the questionnaire used for measuring the quality of life, only one study used a cardiovascular disease specific-instrument and most studies did not consider whether or not the validity of their instrument had been established. In addition, when using questionnaires developed in other languages, only one study employed a translation/back-translation technique. The types of variables tested for their influence on quality of life were quite limited. Conclusion: It is recommended to develop a reliability and validity established cardiovascular disease specific-quality of life for Korean patients and to identify associated new variables.

  • PDF

Measuring Individuals' Privacy Concerns and Survey of Privacy Recognition (개인정보 보호 의식 측정 척도의 개발과 개인정보 중요성에 관한 인지도 조사)

  • Kim, Yeong-Real
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.15 no.5
    • /
    • pp.259-271
    • /
    • 2010
  • It is inevitable that personal privacy will be one of the most significant pressure points for most of the 2000s. Information privacy has been called one of the most important ethical issues in information age. It has become apparent that organizational practices, individuals' perceptions of these practices, and societal responses are very closely related in many ways. However, unfortunately, researches attempting to develop and validate an instrument that identifies and measures the primary dimensions of individuals' concerns about organizational information privacy practices were scarce. Based on a number of preliminary studies, this study tried to develop and validate an Korean organization oriented measurement instrument. This instrument is expected to be used as useful guide lines for the managers who are responsible for IT/IS ethical issues.

A Suggestion for Counting Efficiency Management of the Automation Instrument (자동화장비 계측효율 관리적 측정방법 제안)

  • Park, Jun Mo;Kim, Han Chul;Choi, Seung Won
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.2
    • /
    • pp.105-111
    • /
    • 2018
  • Purpose Quality control of instrument takes up a large part in the Radioimmunoassays. The gamma-ray instrument, which is one of the important instruments in the laboratory, observes the condition and performance of instrument and performs quality control of the instrument by measuring the Normalization, Calibration, Background and etc. However, there are some automation instruments which can't measure the counting efficiency of gamma-ray meters, resulting in insufficient management in terms of performance evaluation of gamma-ray meters. Therefore, the purpose of this paper is to manage the quality control continuously and regularly by suggesting how to measure the counting efficiency of gamma-ray instruments. Materials and Methods In case of a comparative measurement method to a gamma-ray instrument dedicated to nuclear medical examination, the CPM and counting efficiency can be obtained after the measurement of normalization by inserting the I-125 $200{\mu}L$(CPM 50,000~500,000) into the test tube. With this CPM and counting efficiency values, it's possible to calculate the measurement of the DPM value and count the CPM from the automation instrument from the same source, and enter the DPM to calculate the counting efficiency using a comparative measurement method. Another method is to calculate the counting efficiency by estimating the half life using the radiation source information of the tracer in B test reagents of company A. Results According to the calculation formula using the DPM obtained by counting the normalization of gamma-ray meters, the detection efficiency was 75.16% for Detector 1, 76.88% for Detector 2, 77.13% for Detector 3, 75.36% for Detector 4 and 73.2% for Detector 5 respectively. Using another calculation formula estimated from the shelf life, the data of the detection efficiency from Detector 1 to Detector 5 were 74.9%, 75.1%, 76.5%, 74.9% and 73.2% respectively. Conclusion Although the accuracy of counting efficiencies of both methods are insufficient, this is considered to be useful for ongoing management of quality control if counting efficiency is managed after setting the acceptable ranges. For example, if the measurement efficiency is set to 70% or higher, the allowed %difference between measurements is within 3% and the %difference with the detector wall is set within 5%.

Approximations of Optimal Calibration Experimental Designs Using Gaussian Influence Diagrams

  • Kim, Sung-Chul
    • Journal of the Korean Statistical Society
    • /
    • v.22 no.2
    • /
    • pp.219-234
    • /
    • 1993
  • A measuring instrument must be calibrated for accurate inferences of an unknown quantity. Bayesian calibration designs with respect to squared error loss based on a linear model are discussed in Kim and Barlow (1992). In this paper, we consider approximations of the optimal calibration designs using the idea of Gaussian inflence diagrams. The approximation is evaluated by means of numerical calculations, where it is compared with the exact values from the numerical integration.

  • PDF

A Study on the Instrument Measuring Microscopic Movements using a LASER Light Source (레이저 광원을 이용한 극미세 진동 특정장치에 관한 연구)

  • 강성철;지철근
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.8 no.4
    • /
    • pp.17-21
    • /
    • 1994
  • 레이저 광원을 사용하여 정현적으로 극미세 진동하는 압전소자에 부착된 거울을 대상으로 마이켈슨 간섭계로 부터의 간섭신호를 감지해 변위의 크기와 주파수를 측정할 수 있는 진동측정 방법과 장치를 제시한다. 약 80[nm]~1.2[$\mu\textrm{m}$] 범위의 진폭을 가진 물체의 변위와 주파수를 매우 높은 정밀도로 측정하고, 빔의 파장보다 큰 진동물의 간섭신호를 컴퓨터로 처리하여 진동형태의 개형을 구해다.

  • PDF