• Title/Summary/Keyword: Measurement validation

Search Result 700, Processing Time 0.031 seconds

Simulation of Methane Swirl Flame in a Gas Turbine Model Combustor (가스터빈 모사 연소기에서 선회 확산 화염의 연소특성 해석)

  • Joung, Dae-Ro;Huh, Kang-Yul
    • 한국연소학회:학술대회논문집
    • /
    • 2007.05a
    • /
    • pp.118-125
    • /
    • 2007
  • The firtst-order conditional moment closure (CMC) model is applied to CH4/air swirl diffusion flame in a gas turbine model combustor. The flow and mixing fields are calculated by fast chemistry assumption with SLFM library and a beta function pdf for mixture fraction. RNG k-e model is used to consider the swirl flame in a confined wall. Reacting scalar fields are calculated by elliptic CMC formulation with chemical kinetic mechanism, GRI Mech 3.0. Validation is done against measurement data for mean flow and scalar fields in the model combustor [1]. Results show reasonable agreement with the mean mixture fraction and its variance, while temperature is overpredicted as the level of local extinction increases. The second-order CMC model is needed to consider local extinction with considerable conditional fluctuations near the nozzle.

  • PDF

Proficiency Test for Anions and Metal Ions in Aqueous Solution (수용액중 음이온 및 금속에 대한 숙련도 시험)

  • 이종해
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.16 no.1
    • /
    • pp.69-77
    • /
    • 2000
  • This paper summerizes the results of the first proficiency testing program for achieving the analytical quality assurance of anions and metal ions in air borne particles in Korea. This program covered the chemical testing of anions(Cl-, NO3-, SO42-) and metals(Fe, Pb, Zn) in qeueous solution. The exercies was conducted by the Measurement & Analysis Committee of Korean Society for Atmospheric Environment(KOSAE). Pilot lab. was Division of Chemical Metrology and Materais Evaluation in Korea Research Institute of Standards and Science(KRISS). A total of 11 laboratories participated in the program. Two samples of 100mL in low density polyehylene bottles were supplied to participating laboratories. The proficiency testing results were interpreted by two graphical methods, Youden polt and x-Charts(control chart).

  • PDF

A Study on the Calibration Techniques for Thermopile Pyranometer (일사계 교정기법에 관한 연구)

  • Jo, Dok-Ki;Kang, Yong-Heack
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2008.11a
    • /
    • pp.161-166
    • /
    • 2008
  • The major purpose of this paper is to develop an uncertainty estimate for the calibration of thermopile instruments used to measure solar radiation parameters. We briefly describe the solar radiation parameters most often measured, instrumentation, reference standards, and calibration techniques. The bulk of the paper describes elemental sources of error and their magnitude. We then apply a standard error analysis methodology to combine these elemental error estimates into a statement of total uncertainty for the instrument calibration factor. Our results allow one to evaluate the accuracy of a radiometric measurement using thermopile instrumentation in the light of the application, such as engineering test evaluation or for validation of theoretical models.

  • PDF

An Estimation of a Billet Temperature during Reheating Furnace Operation

  • Jang, Yu-Jin;Kim, Sang-Woo
    • International Journal of Control, Automation, and Systems
    • /
    • v.5 no.1
    • /
    • pp.43-50
    • /
    • 2007
  • Reheating furnace is an essential facility of a rod mill plant where a billet is heated to the required rolling temperature so that it can be milled to produce wire. Although it is very important to obtain information on billet temperatures, it is not feasible during furnace operation. Consequently, a billet temperature profile should be estimated. Moreover, this estimation should be done within an appropriate time interval for an on-line application. In this paper, a billet heat transfer model based on 2D FEM(Finite Element Method) with spatially distributed emission factors is proposed for an on-line billet temperature estimation and also a measurement is carried out for two extremely different furnace operation patterns. Finally, the difference between the model outputs and the measurements is minimized by using a new optimization algorithm named uDEAS(Univariate Dynamic Encoding Algorithm for Searches) with multi-step tuning strategy. The obtained emission factors are applied to a simulation for the data which are not used in the model tuning for validation.

A Comparative Analysis between Manufacturing and Transactional/Service Processes of Six Sigma Quality Improvement (제조부문과 사무간접/서비스부문의 6시그마 프로세스 개선활동 비교분석)

  • Yoon, Jae-Wook;Kim, Bo-Hyoung
    • Journal of Korean Society for Quality Management
    • /
    • v.36 no.4
    • /
    • pp.37-46
    • /
    • 2008
  • There are big differences in six sigma projects between manufacturing processes and transactional/service processes. This paper analyzed the differences between the two areas by examining 18 six sigma case studies in Korean companies. To characterize six sigma case studies, step-by-step questions and check criteria were developed based on 12 step DMAIC methodology. On the basis of those characterized data, the differences between two areas were analyzed. Significant differences were found in the number of CTQs, validation of measurement systems, methods to determine improvement objectives, the methods to elicit improvement plans and types of control systems. The most significant difference was that statistical tools were widely used in manufacturing processes, but qualitative tools were used in transactional/service processes during improvement phase.

Development and its Validation of Sky Simulator Facilities for Daylighting Evaluation (자연채광 성능평가용 인공천공돔(Sky Simulator)의 개발 및 신뢰성 검증)

  • Kim, Jeong-Tai;Kim, Gon;Yu, In-Hye
    • KIEAE Journal
    • /
    • v.5 no.4
    • /
    • pp.51-57
    • /
    • 2005
  • For the evaluating daylighting performance, field measurement, scale model test and a set of computer tools can be applied. For the scale model measurements, the sky simulator is a vital facility to represent the desired sky conditions consistently. Recently K university has developed a large size sky simulator, 6m-diameter and 3.7m-height, that is suitable for the international standard. To verify the reliability of the sky simulator, the luminance distribution on the inner sky surface was measured and compared with the CIE standard overcast sky model. It is found that the sky simulator can be reproduced the CIE standard overcast sky condition with 4.3% as mean difference. K university sky simulator is fully validated for usability and accuracy for daylighting researches.

Comparison of the Standard Floor Impact Sound with Living Impact Source by Subjective Evaluation

  • Park, Hyeon Ku;Kim, Kyeong Mo;Kim, Sun-Woo
    • KIEAE Journal
    • /
    • v.14 no.1
    • /
    • pp.39-48
    • /
    • 2014
  • In the previous test, the verification of the standard floor impact source was carried out comparing the physical characteristics with living impact sources. The result was appeared the validation of the standard impact source was very low because of differences of physical characteristics. This study aims to evaluate annoyance and loudness of standard impact source which is used for the measurement of floor impact sound, and to compare the annoyance and loudness of living impact sources which are produced in real life. The impact sources considered are tapping machine, tire and impact ball as standard sources, and nine real sources which were chosen from the existing researches. The result showed differences of annoyance and loudness between standard impact sources and living impact sources, which means the standard impact sources may rate the performance of floor system inappropriately. In the future, the rating method should be examined how the standard impact sources are similar with real sources in the point of rating the performance of floor system.

Gravity Modeling and Validation for High Accuracy Navigation Computation

  • Cho, Yun-Cheol;Shin, Yong-Jin;Park, Jeong-Hwa;Kim, Cheon-Joong;Choi, Kyung-Ryong
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.64.1-64
    • /
    • 2001
  • Errors in inertial navigation system(INS) can be divided into two major groups which are system related errors and modeling errors due to approximation and linearization. Measurement noise, calibration, and alignment errors make up the first group, whereas the uncertainties in the gravity vector fall in the second category and are important error source for high quality INS, especially during high altitude and and/or long time missions, when the gravity errors tent to build up. The quality of a medium to high accuracy INS depends on the knowledge of the local gravity field. In this paper, the feasibility of improving airborns INS by use of more accurate gravity model is studied. To make consistent comparisons, WGS-84 parameters are used and ...

  • PDF

Validation of the Gerotranscendence Scale of Erikson's 9th Stage (Erikson의 9단계 노년초월척도의 한국판 타당화)

  • An, Jeong-Shin
    • The Korean Journal of Community Living Science
    • /
    • v.26 no.1
    • /
    • pp.51-61
    • /
    • 2015
  • This study introduces the possibility of the $9^{th}$ stage by Joan Erikson by adding Erikson's original theory of the $8^{th}$ stage and validates the gerotranscendece scale in later life. For this, 10 items from Erikson's scale was examined and the relationships among gerotranscendence, ego-integrity, and wisdom were examined using a sample of 244 elderly individuals over the age of 60. According to the results, the measurement of gerotranscendence based on Erikson was applicable to the Korean sample. In addition, ego-integrity and wisdom influenced gerotranscendence in later life. Based on these results, the validity of gerotranscedence, psychosocial development in the $9^{th}$ stage, discussed and the utility of Erikson's theory is emphasized.

Coordinate Measuring Technique based on Optical Triangulation using the Two Images (두장의 사진을 이용한 광삼각법 삼차원측정)

  • 양주웅;이호재
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.76-80
    • /
    • 2000
  • This paper describes a coordinate measuring technique based on optical triangulation using the two images. To overcome the defect of structured light system which measures coordinate point by point, light source is replaced by CCD camera. Pixels in CCD camera were considered as virtual light source. The overall geometry including two camera images is modeled. Using this geometry, the formula for calculating 3D coordinate of specified point is derived. In a word, the ray from a virtual light source was reflected on measuring point and the corresponding image point was made on the other image. Through the simulation result, validation of formula is verified. This method enables to acquire multiple points detection by photographing.

  • PDF