• 제목/요약/키워드: Measurement conditions

검색결과 3,637건 처리시간 0.033초

여성 견비통 환자의 생혈액 형태에 대한 임상적인 연구 (A Clinical Study of the Live Blood Condition of Women′s Shoulder Measurement)

  • 김경철
    • 대한한의학회지
    • /
    • 제25권3호
    • /
    • pp.99-104
    • /
    • 2004
  • Objectives : To study the Live Blood Condition of chronic shoulder measurement. Methods : Twenty-one patients were studied. The observation items of the Live Blood Condition are the form's abnormality and cohesion of red blood cells, the abnormality of hemoglobin and the toxicity in plasma. Results : 1. The form's abnormality and cohesion of red blood cells observed were erythrocyte aggregation (8 persons), Rouleau (3 persons), target cells (7 persons), ovalocytes (3 persons), poikilocytes (2 persons). Double conditions observed were erythrocyte aggregation & target cells (3 persons), erythrocyte aggregation & poikilocytes (1 person), target cells & ovalocytes (l person). 2. The abnormality of hemoglobin and the toxicity in plasma observed were cholesterol crystals (5 persons), atherosclerotic plaque (3 persons), chylous (6 persons). 3. The form normality of red blood was generally observed in one woman. The normality of hemoglobin and the non-toxicity in plasma were generally observed in seven women. Conclusions : According to this study of the Live Blood Condition of women's shoulder measurement, these results suggest that the twenty-one patients evidence the conditions of extravasated blood and phlegm.

  • PDF

Taguchi 실험계획법을 이용한 경혈점의 피부전기특성 최적화조건 선정 : A Pilot Study (Application of Taguchi's Robust Design Method in Optimization of Measuring Electrical Properties on Acupoints: A Pilot Study)

  • 남동현;신상훈
    • Korean Journal of Acupuncture
    • /
    • 제25권3호
    • /
    • pp.15-27
    • /
    • 2008
  • Objectives : The objective of the current study is to optimize an acupoint electrical property measurement system by using the procedures and strengths of the Taguchi method. Methods : Taguchi method was applied in the optimization of the acupoint electrical property measurement system, as in the following steps: (1) determine evaluation index; (2) execute the 1st gage R&R; (3) identify controllable and uncontrollable factors; (4) design Taguchi crossed array layout; (5) execute experiments according to trial conditions; (6) analyze testing results; (7) determine optimum run; (8) execute the 2nd gage R&R; (9) confirm optimum run. Results : The results showed that electrodes with larger diameter and efferent electric current, with music played, can produce the larger different electrical conductivity between the acupoints and the non-acupoints under various conditions. Taguchi process optimization improved repeatability and reproducibility of the acupoint electrical property measurement system. Conclusions : In the optimized condition, repeatability and reproducibility of the acupoint electrical property measurement system was acceptable.

  • PDF

Structural Intensity 법을 이용한 구조체의 진동전달량 측정 (Measurements of the Vibrational Power Flow in Structure Beam by Using the Structural Intensity Method)

  • 김흥식
    • 소음진동
    • /
    • 제4권2호
    • /
    • pp.231-238
    • /
    • 1994
  • This paper presents an experimental method to find the vibrational transmission characteristics of structures by using the structural intensity method which is used as the important techniques of active vibration control method. Experimental results are obtained from measurements performed on a structure beam by 2, 3 and 4 position linear accelerometr array (2, 3 and 4 structural intensity : 2, 3 and 4 S.I.) methods at near and farfield conditions. These results are compared with the measurement values of conventional power flow measurement method called input power measurement in order to verify the accuracy of structural intensity methods. To minimize the errors associated with 2, 3 and 4 S.I. methods, the measurement locations were selected by the result of modal analysis and the averaged data by the inter-change of accelerometer array was utilized. In 3 and 4 S.I. methods measured wavenumber instead of theoretical wavenumber was used. This paper shows that measurements of bending wave power flow by using 2, 3 and 4 S.I. methods can give accurate values under general field conditions in structural beam and the accuracy of 2, 3 S.I. methods is higher than 4 S.I. methods. Finally, 2 position linear accelerometer array method is suggested as the practical structural intensity technique.

  • PDF

Factors affecting modulation transfer function measurements in cone-beam computed tomographic images

  • Choi, Jin-Woo
    • Imaging Science in Dentistry
    • /
    • 제49권2호
    • /
    • pp.131-137
    • /
    • 2019
  • Purpose: This study was designed to investigate the effects of voxel size, the oversampling technique, and the direction and area of measurement on modulation transfer function (MTF) values to identify the optimal method of MTF measurement. Materials and Methods: Images of the wire inserts of the SedentexCT IQ phantom were acquired, and MTF values were calculated under different conditions(voxel size of 0.1, 0.2, and 0.3 mm; 5 oversampling techniques; simulated pixel location errors; and different directions and areas of measurement). The differences in the MTF values across various conditions were evaluated. Results: The MTF 10 values showed smaller standard deviations than the MTF 50 values. Stable and accurate MTF values were obtained in the 0.1-mm voxel images. In the 0.3-mm voxel images, oversampling techniques of 11 lines or more did not show significant differences in MTF values depending on the presence of simulated location errors. MTF 10 values showed significant differences according to the direction and area of the measurement. Conclusion: To measure more accurate and stable MTF values, it is better to measure MTF 10 values in small-voxel images. In large-voxel images, the proper oversampling technique is required. MTF values from the radial and tangential directions may be different, and MTF values vary depending on the measured area.

Analysis of pipe thickness reduction according to pH in FAC facility with In situ ultrasonic measurement real time monitoring

  • Oh, Se-Beom;Kim, Jongbeom;Lee, Jong-Yeon;Kim, Dong-Jin;Kim, Kyung-Mo
    • Nuclear Engineering and Technology
    • /
    • 제54권1호
    • /
    • pp.186-192
    • /
    • 2022
  • Flow accelerated corrosion (FAC) is a type of pipe corrosion in which the pipe thickness decreases depending on the fluid flow conditions. In nuclear power plants, FAC mainly occurs in the carbon steel pipes of a secondary system. However, because the temperature of a secondary system pipe is over 150 ℃, in situ monitoring using a conventional ultrasonic non-destructive testing method is difficult. In our previous study, we developed a waveguide ultrasonic thickness measurement system. In this study, we applied a waveguide ultrasonic thickness measurement system to monitor the thinning of the pipe according to the change in pH. The Korea Atomic Energy Research Institute installed FAC-proof facilities, enabling the monitoring of internal fluid flow conditions, which were fixed for ~1000 h to analyze the effect of the pH. The measurement system operated without failure for ~3000 h and the pipe thickness was found to be reduced by ~10% at pH 9 compared to that at pH 7. The thickness of the pipe was measured using a microscope after the experiment, and the reliability of the system was confirmed with less than 1% error. This technology is expected to also be applicable to the thickness-reduction monitoring of other high-temperature materials.

DC Potential Drop 측정을 이용한 S45C강의 템퍼링과정 비파괴 평가 (Nondestructive Evaluation of Tempering Process of S45C Steel using DC Potential Drop Measurement)

  • 박용기;안봉영
    • 비파괴검사학회지
    • /
    • 제9권1호
    • /
    • pp.77-82
    • /
    • 1989
  • DC potential drop(DCPD) measurement system was made and the optimum measuring conditions have been studied. The room temperature resistivity of commercially available medium carbon steel(S45C) was measured using this technique. DCPD was measured in the specimens which were hardened and tempered at different temperatures. It was found that DCPD reflected the change of the microstructure during tempering very sensitively. It was possible to monitor the stage of tempering of S45C steel nondestructively using DCPD measurement.

  • PDF

경량 바닥구조의 바닥충격음 저감량 실험실 측정방법 고찰 (Review of measurement of impact sound improvement for light-weight floor)

  • 장길수;정광용;김선우
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 추계학술대회논문집
    • /
    • pp.950-955
    • /
    • 2002
  • ISO 140-11 specifies a method for measuring the acoustic properties of floor coverings from the view-point of reducing impact sound transmission. This test method is limited to the specification of procedures for the physical measurement of sound originating from an artificial impact source under laboratory conditions. In this study, ISO 140-11 was reviewed to applicable to domestic floor coverings installed on lightweight floors.

  • PDF

Improved Collaborative Filtering Using Entropy Weighting

  • Kwon, Hyeong-Joon
    • International Journal of Advanced Culture Technology
    • /
    • 제1권2호
    • /
    • pp.1-6
    • /
    • 2013
  • In this paper, we evaluate performance of existing similarity measurement metric and propose a novel method using user's preferences information entropy to reduce MAE in memory-based collaborative recommender systems. The proposed method applies a similarity of individual inclination to traditional similarity measurement methods. We experiment on various similarity metrics under different conditions, which include an amount of data and significance weighting from n/10 to n/60, to verify the proposed method. As a result, we confirm the proposed method is robust and efficient from the viewpoint of a sparse data set, applying existing various similarity measurement methods and Significance Weighting.

  • PDF

광대역 주파수를 가진 전력 측정 변환기 (A watt-converter for a wideband frequency power measurement)

  • 박영태;정재갑;강전홍;유권상
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 D
    • /
    • pp.2332-2334
    • /
    • 2004
  • A high bandwidth watt-converter, based on an inexpensive, commercially available, standard IC package, is described that covers a frequency ranges from DC to 100 kHz. The new resistive shunt for a wide-band frequency current measurement of the watt-converter was developed. The converter will use application in accurate power measurement under distorted and high frequency conditions. The advantages of the watt-converter are its simplicity, low cost and fast response time.

  • PDF

경량바닥구조의 바닥충격음 저감량 실험실 측정방법 고찰 (Review of measurement of impact sound improvement for light-weight floor)

  • Jang, Gil-Soo;Kim, Sun-Woo;Jung, Kwang-Yong
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 추계학술대회논문초록집
    • /
    • pp.392.2-392
    • /
    • 2002
  • ISO 140-11 specifies a method for measuring the acoustic properties of floor coverings from the view-point of reducing impact sound transmission. This test method is limited to the specification of procedures for the Physical measurement of sound originating from an artificial impact source under laboratory conditions. In this study, ISO 140-11 was reviewed to applicable to domestic floor coverings installed on lightweight floors.

  • PDF