• Title/Summary/Keyword: Measurement Validation

Search Result 705, Processing Time 0.029 seconds

Calibration of an underwater robotic inspection system (수중탐상로봇시스템의 오차분석 및 보정)

  • 장종훈;김재열;김재희
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.378-378
    • /
    • 2000
  • The permissible positioning error of the transducer used in reactor inspection must be within 10 mm. To implement the required precision it is necessary to manufacture all components affecting the positioning mechanism correctly and precisely. In addition, it is also necessary to handle error factors accurately. This paper describes the activities of the findings and corrections of the errors which were occurred in experiments. Those activities are; i) Categorization of error factors, ii) Cause analysis of errors, iii) Correction of errors founded in experiments by the analysis of laser induction type and by the validation of real measurement of horizontal, vertical baselines.

  • PDF

Unsteady Performance Analysis of a Simple Shaft Gas Turbine Cycle (단순 가스터빈 사이클 과도 성능해석)

  • Kim, Soo-Yong;Soudarev, B.
    • 연구논문집
    • /
    • s.30
    • /
    • pp.5-13
    • /
    • 2000
  • The computation scheme of simulating gas turbine transient behavior was developed. The basic principles of this scheme and main input data required are described. Calculation results are presented in terms of whole operating regime of the cycle. The influence of main initial parameters such as starting engine power, moment of inertia of the rotor, fuel supplying schedule etc. on performance characteristics of has turbine during transient operation is studied In addition, bleeding air influence on transient behavior was also considered For validation of the developed code, comparison of present calculation with that of measurement data of the experimental data for the range of operating period studied.

  • PDF

Efficient Approach to Thermal Modeling for IC Packages (효율적 수치해석기법을 이용한 반도체 페키지의 열방출 해석)

  • Seung Mo Kim;Choon Heung Lee
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.6 no.2
    • /
    • pp.31-36
    • /
    • 1999
  • An efficient method for thermal modeling of QFP is Proposed. Thermal measurement data are given to verify the method. In parallel with the experiment, an exact full 3-D model calculation is also provided. One fonds that there is an excellent agreement between validation data and the efficient model data.

  • PDF

Experimental technique for efficiency transfer along different geometries and volumes

  • Haddad, Kh;AL-Homyed, A.
    • Nuclear Engineering and Technology
    • /
    • v.53 no.2
    • /
    • pp.695-698
    • /
    • 2021
  • Efficiency calibration is a fundamental procedure in gamma spectrometric measurement. Experimental technique for efficiency calibration transfer in gamma spectrometer along different geometries and volumes has been developed and validated in this work. The developed technique offers simple and easy procedures to overcome several problems encountered in efficiency calibration of gamma spectrometer such as rate-related correction and different sample volumes. The validation shows that application of the developed technique has a precision of 95%.

A Study on the Validation of Measured Data from the Seismic Accelerometers in the Safety Evaluation System of Public Buildings (공공건축물 안전성 평가를 위한 지진가속도 계측자료의 유효성 검증 방법에 대한 연구)

  • Jang, Won-Seok;Jeong, Seong-Hoon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.24 no.5
    • /
    • pp.150-157
    • /
    • 2020
  • In this study, an algorithm was developed to validate the seismic acceleration measurement data of the seismic acceleration measurement system using measurement data from public buildings currently in operation. Through the results of the study, an algorithm was developed to detect errors and abnormalities in the measurement data itself and the process of generating real-time data (MMA/sec) and event measurement data (MiniSEED), which are the main data generated by the system, and the basic data for determining the direction of inspection through measurement data analysis. It is expected that this will be used as a guideline to determine whether or not the seismic acceleration measurement system, which was managed as receiving/not receiving, is inspected and abnormal types of conditions.

The Cross-validation of Satellite OMI and OMPS Total Ozone with Pandora Measurement (지상 Pandora와 위성 OMI와 OMPS 오존관측 자료의 상호검증 방법에 대한 분석 연구)

  • Baek, Kanghyun;Kim, Jae-Hwan;Kim, Jhoon
    • Korean Journal of Remote Sensing
    • /
    • v.36 no.3
    • /
    • pp.461-474
    • /
    • 2020
  • Korea launched Geostationary Environmental Monitoring Satellite (GEMS), a UV/visible spectrometer that measure pollution gases on 18 February 2020. Because satellite retrieval is an ill-posed inverse solving process, the validation with ground-based measurements or other satellite measurements is essential to obtain reliable products. For this purpose, satellite-based OMI and OMPS total column ozone (TCO), and ground-based Pandora TCO in Busan and Seoul were selected for future GEMS validation. First of all, the goal of this study is to validate the ground ozone data using characteristics that satellite data provide coherent ozone measurements on a global basis, although satellite data have a larger error than the ground-based measurements. In the cross validation between Pandora and OMI TCO, we have found abnormal deviation in ozone time series from Pandora #29 observed in Seoul. This shows that it is possible to perform inverse validation of ground data using satellite data. Then OMPS TCO was compared with verified Pandora TCO. Both data shows a correlation coefficient of 0.97, an RMSE of less than 2 DU and the OMPS-Pandora relative mean difference of >4%. The result also shows the OMPS-Pandora relative mean difference with SZA, TCO, cross-track position and season have insignificant dependence on those variables.In addition, we showed that appropriate thresholds depending on the spatial resolution of each satellite sensor are required to eliminate the impact of the cloud on Pandora TCO.

Noise Reduce in the Rotary Compressor for air-conditioner using Structural Modification (구조 변경을 통한 공조용 압축기의 소음저감)

  • Kim, Jin-Soo;Lee, Seung-Mock;Ha, Jong-Hun;Lee, Jang-Woo;Ha, Sam-Chul
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2010.10a
    • /
    • pp.556-563
    • /
    • 2010
  • The main noise source of the rotary compressor for air conditioner was analyzed by using the measurement of sound intensity, modal analysis and operational deflection shape(ODS) analysis. In this study, the key noise source of rotary compressor was an accumulator, and noise was sharply increased due to the accumulator's resonance which has a big contribution to the noise. To reduce the excessive noise generated from accumulator, structural modification through ODS analysis were applied. Its validation was conducted by the measurement of noise and vibration on the accumulator's surface. The total noise was significantly reduced by 4.2dB(A).

  • PDF

Development of a Combined GPS/GLONASS PPP Method

  • Choi, Byung-Kyu;Roh, Kyoung-Min;Lee, Sang Jeong
    • Journal of Positioning, Navigation, and Timing
    • /
    • v.3 no.1
    • /
    • pp.31-36
    • /
    • 2014
  • Precise Point Positioning (PPP) is a stand-alone precise positioning approach. As the quality of satellite orbit and clock products from analysis centers has been improved, PPP can provide more precise positioning accuracy and reliability. A combined use of Global Positioning System (GPS) and Global Orbiting Navigation Satellite System (GLONASS) in PPP is now available. In this paper, we explained about an approach for combined GPS and GLONASS PPP measurement processing, and validated the performance through the comparison with GPS-only PPP results. We also used the measurement obtained from the GRAS reference station for the performance validation. As a result, we found that the combined GPS/GLONASS PPP can yield a more precise positioning than the GPS-only PPP.

A Validation Study on the Home Observation for Measurement of the Environment in Elementary Children (가정환경검사(HOME)의 타당화 연구)

  • Lee, Ju-Lie
    • Journal of Families and Better Life
    • /
    • v.10 no.1 s.19
    • /
    • pp.1-13
    • /
    • 1992
  • The purpose of this study was to validate the Elementary HOME(Home Observation for Measurement of the Environment) with korean elementary children. Subjects were 536 mothers 1st-5th graders in the elementary schools in the Seoul. Pearson's r, pearcentage(%), phi($\phi$/), Cronbach's $\alpha$/ ware conducted for the statistical analysis. The major findings were as follows. 1) The item pass rate(percentage) were ranged 16~98. 2) The discriminant coefficients($\phi$/) of the item were ranged 0.06~0.58. 3) The reliability coefficients of the scale were that the split-falf was 0.84, and Cronbach's $\alpha$/ was 0.88. Considering the length of the scale, these reliability estimates appear to be at an acceptable level 4) The factor analysis and the correlations between HOME and SES indices and children's school schievement to test construct validity were conducted to test construct validity. Eight factors were extracted from the factor analysis and coefficients(r) were ranged 0.16~0.45 and -0.08~0.37.

  • PDF