• Title/Summary/Keyword: Measurement Devices

Search Result 1,571, Processing Time 0.032 seconds

Characteristics of organic electroluminescent devices having buffer layers (Buffer층을 가진 유기 전기 발광 소자의 특성)

  • 이호식;고삼일;정택균;이원재;김태완;강도열
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1998.06a
    • /
    • pp.399-402
    • /
    • 1998
  • Electroluminescent(EL) devices based on organic thin films have attracted lots of interests in large-area light-emitting display. One of the problems of such device is a lifetime, where a degradation of the cell is possibly due to an organic layers thickness, morphology and interface with electrode. In this study, light-omitting organic electroluminescent devices were fabricated using Alq$_3$(8-hydroxyquinolinate aluminum) and TPD(N,N'-diphenyl-N,N'-bis(3-methylphenyl(1-1\`-biphenyl]-4,4'-diamine). Where Alq$_3$ is an electron-transport and emissive layer, TPD is a hole-transport layer. The cell structure is ITO/TPD/Alq$_3$/Al and the cell is fabricated by vacuum evaporation method. In a measurement of current-voltage characteristics, we obtained a turn-on voltage at about 9 V. We also investigated stability of the devices using buffer layer with blend of PEI (Poly ether imide) and TPD by varying mot ratios between ITO and Alq$_3$. In current-voltage characteristics measurement, we obtained the turn-on voltage at about 6 V and observed an anomalous behavior at 3∼4 V. And we used other buffer layer of PEDT(3,4-pyrazino-3',4'-ethylenedithio-2,2',5,5'-tetrathiafulvalenium) with ITO/PEDT/TPD/Alq$_3$Al structure. We observed a surface morphology by AFM(Atomic Force Microscopy), UV/visible absorption spectrum, and PL(Photoluminescence) spectrum. We obtained the UV/visible absorption peak at 358nm in TPD and at 359nm in Alq$_3$, and the PL peaks at 410nm in TPD and at 510nm in Alq$_3$. We also studied EL spectrum in the cell structure of ITO/(TPD+PEI)/Alq$_3$/Al.

  • PDF

The Comparison and Analysis of Maritime Precise Positioning using GPS Based Smartphone

  • Park, Sul Gee;Park, Sang Hyun
    • Journal of Positioning, Navigation, and Timing
    • /
    • v.7 no.4
    • /
    • pp.217-226
    • /
    • 2018
  • According to the Korea Coast Guard's maritime disaster statistics (Korea Coast Guard 2017, Korean Statistical information Service 2018), an average of 2,140 marine accidents occurred every year for the past 6 years and the number of accidents is increasing every year. Among them, maritime accidents of fishing vessels are the most frequent, and recently accidents involving fishing boat and leisure vessels are rapidly increasing as well. In particular, the number of accidents involving leisure vessels increased to about one-third of the accidents of fishing vessels, and emergency rescue requests are increasing every year accordingly. However, the number of crash accidents involving users of small vessels and marine leisure activities are increasing because of the difficulties of installing navigation equipment and electronic navigation charts. Recently, the demand for precise positioning using mobile devices is increasing in the fields of maritime safety, piloting support, and coastal survey. Although various applications of smart devices provide location-based services for users, the measurement results are discontinuous when using the position coordinates of the National Marine Electronics Association (NMEA) calculated by smartphone. Recently, Google announced that they will provide GPS raw data to developers from Android 7.0 Nougat. As a result, developers have an opportunity to receive precise carrier phase and code measurements to make more accurate positioning according to the performance of Android devices. This study analyzed GPS positioning performance using Android devices, and compared and analyzed the positioning performance at sea with high-performance GPS receivers.

Computational Analysis and Measurement for SDR-based Spectrum Sensing System Design on Single Board Computer (소프트웨어 정의 라디오 기반 스펙트럼 센싱 시스템 설계를 위한 단일 보드 컴퓨터 내 연산 분석 및 측정 연구)

  • Kim, Joon Young
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.23 no.12
    • /
    • pp.1650-1658
    • /
    • 2019
  • In recent years, IoT device and platform become widely popular and the computing performance and capabilities of IoT devices are also getting improved. However, the size and computing resources of IoT devices, especially small single board computer, are limited in a way that the design and implementation of the system should be carefully considered to operate on the devices. Recently, SDR technologies are adapting in IoT devices and can perform various radio systems. Thorough analysis and investigation of computer performances on small single board computer are necessary for its usage. In this paper, we present the results of computing resources measurement and analysis on small single-board computers. At first, we consider to design SDR based spectrum sensing for single board computer, investigate various key factors and propose a design procedure that can affect performance of the system with experiments.

Effects of Ohmic Area Etching on Buffer Breakdown Voltage of AlGaN/GaN HEMT

  • Wang, Chong;Wel, Xiao-Xiao;Zhao, Meng-Di;He, Yun-Long;Zheng, Xue-Feng;Mao, Wei;Ma, Xiao-Hua;Zhang, Jin-Cheng;Hao, Yue
    • Transactions on Electrical and Electronic Materials
    • /
    • v.18 no.3
    • /
    • pp.125-128
    • /
    • 2017
  • This study is on how ohmic area etching affects the buffer breakdown voltage of AlGaN/GaN HEMT. The surface morphology of the ohmic metal can be improved by whole etching on the ohmic area. The buffer breakdown voltages of the samples with whole etching on the ohmic area were improved by the suppression of the metal spikes formed under the ohmic contact regions during high-temperature annealing. The samples with selective etching on the ohmic area were investigated for comparison. In addition, the buffer leakage currents were measured on the different radii of the wafer, and the uniformity of the buffer leakage currents on the wafer were investigated by PL mapping measurement.

Fabrication of Micro-Vacuum Sensor using Surface-Macromachined Lateral-type Field Emitter Device (표면 미세 가공된 측면형 전계 방출 소자를 이용한 초소형 진공 센서의 제작)

  • Park, Heung-Woo;Ju, Byeong-Kwon;Lee, Yun-Hi;Park, Jung-Ho;Oh, Myung-Hwan
    • Journal of Sensor Science and Technology
    • /
    • v.9 no.3
    • /
    • pp.182-189
    • /
    • 2000
  • A micro-vacuum sensor was fabricated for the measurement of the vacuum level in micro-space. The fact that the field emission current was dependent on the environmental vacuum level was employed as an operating principle. The fabricated lateral-type field emitter triode with a cathode, a gate and a anode separated by using the surface micromachining process showed the emission current variation in the range of $1.20{\sim}2.42\;{\mu}A$ for the vacuum range of $10^{-5}{\sim}10^{-8}\;Torr$.

  • PDF

Evaluation of Dynamic Characteristics of Slipmeters with Force Platform (하중판을 이용한 미끄러짐 측정기의 동력학적 특성 평가)

  • Kim, Jung-Soo
    • Journal of the Korean Society of Safety
    • /
    • v.27 no.5
    • /
    • pp.1-8
    • /
    • 2012
  • The purpose of this study were to evaluate the dynamic characteristics of the portable slipmeters with respect to actual slipping and to compare their output with those of force platform. The selected slipmeters were commonly used devices for slipperiness measurement in situ floors. Their output quantity represented force (BOT-3000), loss of energy(British pendulum striker) and angle of inclination(English XL). The validity of these devices was studied with respect to actual slipping using a force platform. The precision of these devices was also evaluated with force platform. Based on dynamics of human subject behavior when slipping during normal walking, the all devices tested in this study showed poor performances: low built up ratio, low normal pressure, and long contact time prior to slip. Nevertheless, their results reasonably correlated with those calculated from the ground reaction forces generated by the operation of the selected slipmeters on the force platform although the absolute values of COF from these three devices could be quite different. Also the results showed good repeatability under the some test conditions.

The Comparison of the Accuracy upon the Manual Torque Generating Devices for the Implant (임플란트에 사용되는 수동 토크발생장치의 정확성 비교)

  • Kim, Dong-Hwan;Kim, Han-Su;Oh, Sang-Ho;Chung, Chae-Heon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.23 no.3
    • /
    • pp.227-237
    • /
    • 2007
  • Various methods and torque generating devices are developed and employed to apply proper torque clinically. In this study, clinically used torque control devices are measured whether uniformed and precise torque are generated. Digital torque gauge are employed for measurement and torque driver, torque limiting device, torque indicating device are used for torque generating devices. ${\chi}^2$ distribution was formed and One-way ANOVA(Turkey test) was performed to measure torque values generated by each torque generating device. In the results, all companies have been shown slight errors and deviations. This indicates a difficulty of applying precise torque. Therefore, it would be recommended torque generating device should be checked whether uniformed and precise torque can be generated and an error should be corrected.

A CMOS Frequency divider for 2.4/5GHz WLAN Applications with a Simplified Structure

  • Yu, Q.;Liu, Y.;Yu, X.P.;Lim, W.M.;Yang, F.;Zhang, X.L.;Peng, Y.
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.11 no.4
    • /
    • pp.329-335
    • /
    • 2011
  • In this paper, a dual-band integer-N frequency divider is proposed for 2.4/5.2 GHz multi-standard wireless local area networks. It consists of a multi-modulus imbalance phase switching prescaler and two all-stage programmable counters. It is able to provide dual-band operation with high resolution while maintaining a low power consumption. This frequency divider is integrated with a 5 GHz VCO for multi-standard applications. Measurement results show that the VCO with frequency divider can work at 5.2 GHz with a total power consumption of 22 mW.

Improvement of Gesture Recognition using 2-stage HMM (2단계 히든마코프 모델을 이용한 제스쳐의 성능향상 연구)

  • Jung, Hwon-Jae;Park, Hyeonjun;Kim, Donghan
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.21 no.11
    • /
    • pp.1034-1037
    • /
    • 2015
  • In recent years in the field of robotics, various methods have been developed to create an intimate relationship between people and robots. These methods include speech, vision, and biometrics recognition as well as gesture-based interaction. These recognition technologies are used in various wearable devices, smartphones and other electric devices for convenience. Among these technologies, gesture recognition is the most commonly used and appropriate technology for wearable devices. Gesture recognition can be classified as contact or noncontact gesture recognition. This paper proposes contact gesture recognition with IMU and EMG sensors by using the hidden Markov model (HMM) twice. Several simple behaviors make main gestures through the one-stage HMM. It is equal to the Hidden Markov model process, which is well known for pattern recognition. Additionally, the sequence of the main gestures, which comes from the one-stage HMM, creates some higher-order gestures through the two-stage HMM. In this way, more natural and intelligent gestures can be implemented through simple gestures. This advanced process can play a larger role in gesture recognition-based UX for many wearable and smart devices.

Signal Analysis According to the Position of the ECG Sensor Electrode in Healthcare Backpack (헬스케어 가방의 ECG 센서 전극 위치에 따른 신호 분석)

  • Lee, Hyeon-Seok;Chung, Wan-Young
    • Journal of Sensor Science and Technology
    • /
    • v.23 no.6
    • /
    • pp.402-408
    • /
    • 2014
  • Heart rate is one of the most important signal to monitor the health condition of the patient or exerciser. Various wearable devices have been developed for the continuous monitoring of ECG signal from human body during exercise. Among these, ECG chest belt has been widely used. However wearing chest belt with ECG sensor is uncomfortable in normal life due to the electrode contact between metal electrodes of ECG sensor and skin of the human body. So we develop the royal healthcare backpack that can measure ECG signal without skin contact by using capacitor-type ECG sensor. The position of the measurement point is critical to collect a clear ECG signal in the capacitive ECG measurement from backpack. Various tests were conducted to find the optimal ECG measurement position which has less noise and could get strong and clear ECG signal during exercise, walking, hiking, mountain climbing and cycling.