• Title/Summary/Keyword: Measurement CT

Search Result 549, Processing Time 0.03 seconds

Affecting Factors on Left Ventricle Ejection Fraction Measured using 64-slice MDCT (64 절편 MDCT를 이용한 심장CT에서 측정된 좌심실 구혈률에 영향을 미치는 요인)

  • Kang, Yeong-Han;Kim, Kyung-Wook;Cho, Kwang-Ho
    • The Journal of the Korea Contents Association
    • /
    • v.10 no.2
    • /
    • pp.250-257
    • /
    • 2010
  • This study was to analysis what factors could affect left ventricle ejection fraction(LVEF) using 64-slice multidetector CT. 164 patients(84 men, 80 women) had a cardiac CT in this study, and their blood pressure, body mass index(BMI), heart rate(HR) measured. LVEF was 52.00${\pm}$18.95% in below 25kg/$m^2$, 59.50${\pm}$16.05% in above 25kg/$m^2$ of BMI. LVEF was 57.26${\pm}$17.84% in normal blood pressure group(NBPG), 49.95${\pm}$17.63 in hypertension group(HG). LVEF was 60.76${\pm}$17.26 in below 60 beats/min, 54.14${\pm}$16.56 in 60-70 beats/min, 50.83${\pm}$20.56 in above 70 beats/min of HR. LVEF was negatively correlated with age, HR(r=-0.283 p<0.05, r=-0.231 p<0.05. respectively). And LVEF was positively correlated with BMI(r=0.228 p<0.05). A measurement of LVEF at cardiac CT by using MDCT may be considered to age, blood pressure, heart rate and BMI.

Assessment of Aging Effects on Computed Tomographic Glomerular Filtration Rate in Dogs (개에서 연령에 따른 동적 컴퓨터단층촬영을 이용한 사구체여과율의 평가)

  • Chang, Jin-Hwa;Kim, Hwan-Cheol;Choi, Ji-Young;Choi, Ho-Jung;Lee, Hee-Chun;Chang, Dong-Woo;Lee, Young-Won
    • Journal of Veterinary Clinics
    • /
    • v.29 no.2
    • /
    • pp.130-133
    • /
    • 2012
  • The purpose of this study is to assess the relationship between glomerular filtration rate (GFR) and age by using dynamic computed tomography (CT) and Patlak plot analysis in dogs. Fifteen dogs were used in this study. CT-GFR study was performed under general anesthesia using propofol and isoflurane. 1 ml/kg dosage of 300 mgI/ml iohexol was administered at a rate of 3 ml/s during GFR measurement. CT-GFR was determined with a single-slice dynamic acquisition and Patlak plot analysis. The individual and global GFR values were calculated to plasma clearance per body weight (ml/min/kg). Bodyweight ($mean{\pm}SD$) ranged from 2.0 to 5.7 kg ($3.31{\pm}1.13$ kg). Age ranged from 3 years to 13 years old ($7.14{\pm}3.30$). $Mean{\pm}SD$ creatinine ($0.53{\pm}0.34 $mg/dl), phosphorus ($4.1{\pm}1.2$ mg/dL), and albumin ($3.3{\pm}0.3$ mg/dL) concentrations and urine protein-to-creatinine ratios (all ratios were < 0.5) were within reference ranges. Abdominal ultrasonography revealed small-sized renal calculi, mineralization, or renal cyst at eight dogs. The global CT-GFR ranges shown in this study was 2.57 to 6.60 ml/min/kg. In this study, there was no trend toward weight-adjusted CT-GFR with increasing age. We found no relationships between age-related kidney dysfunction in fifteen dogs. Small-sized renal calculi or cysts did not affect renal function in this study. However, it is thought that a large sample size may have been required to document an age effect.

Evaluation of the correlation between the muscle fat ratio of pork belly and pork shoulder butt using computed tomography scan

  • Sheena Kim;Jeongin Choi;Eun Sol Kim;Gi Beom Keum;Hyunok Doo;Jinok Kwak;Sumin Ryu;Yejin Choi;Sriniwas Pandey;Na Rae Lee;Juyoun Kang;Yujung Lee;Dongjun Kim;Kuk-Hwan Seol;Sun Moon Kang;In-Seon Bae;Soo-Hyun Cho;Hyo Jung Kwon;Samooel Jung;Youngwon Lee;Hyeun Bum Kim
    • Korean Journal of Agricultural Science
    • /
    • v.50 no.4
    • /
    • pp.809-815
    • /
    • 2023
  • This study was conducted to find out the correlation between meat quality and muscle fat ratio in pork part meat (pork belly and shoulder butt) using CT (computed tomography) imaging technique. After 24 hours from slaughter, pork loin and belly were individually prepared from the left semiconductors of 26 pigs for CT measurement. The image obtained from CT scans was checked through the picture archiving and communications system (PACS). The volume of muscle and fat in the pork belly and shoulder butt of cross-sectional images taken by CT was estimated using Vitrea workstation version 7. This assemblage was further processed through Vitrea post-processing software to automatically calculate the volumes (Fig. 1). The volumes were measured in milliliters (mL). In addition to volume calculation, a three-dimensional reconstruction of the organ under consideration was generated. Pearson's correlation coefficient was analyzed to evaluate the relationship by region (pork belly, pork shoulder butt), and statistical processing was performed using GraphPad Prism 8. The muscle-fat ratios of pork belly taken by CT was 1 : 0.86, while that of pork shoulder butt was 1 : 0.37. As a result of CT analysis of the correlation coefficient between pork belly and shoulder butt compared to the muscle-fat ratio, the correlation coefficient was 0.5679 (R2 = 0.3295, p < 0.01). CT imaging provided very good estimates of muscle contents in cuts and in the whole carcass.

A study on enamel thickness of maxillary incisors using X-ray micro computed tomography (MicroCT를 이용한 상악 전치의 법랑질 두께에 관한 연구)

  • Cho, Young-Won;Cho, Jin-Hyun;Lee, Kyu-Bok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.48 no.4
    • /
    • pp.301-307
    • /
    • 2010
  • Purpose: The objectives of the current study are to assess the accuracy of X-Ray Micro Computed Tomography (microCT) in measuring enamel thickness and to evaluate enamel thickness in maxillary incisors of Koreans. Materials and methods: Five maxillary incisors were embedded in resin block. These teeth were longitudinally sectioned labiolingually through the medial axis. After polishing, the teeth were scanned using a microCT (X-EYE SYSTEM; DRGEM, Seoul, Korea). On a scanning electron microscope (S-4300; Hitachi, Tokyo, Japan) (${\times}20$) and a microCT, nearly identical planes were reconstructed. In each tooth, the thickness of labial enamel was measured 1, 3 and 5 mm above the cementoenamel junction (CEJ). Thus, the accuracy of the microCT was evaluated. In addition, using 26 maxillary central incisors and 11 maxillary lateral incisors, in the medial axis and 2 mm remote areas mesially and distally from the medial axis, the thickness of labial enamel was measured 1, 3 and 5 mm above the CEJ along the long axis of the teeth. Results: Measurements from nearly identical planes in physical and microCT sections differed by 3.81%. An independent t-test was performed and this showed that there were no significant differences in the measurements between the two methods. Mean values of labial enamel thickness in maxillary central incisors 1, 3 and 5 mm above the CEJ were $0.32{\pm}0.01$, $0.50{\pm}0.0.2$ and $0.70{\pm}0.02\;mm$, respectively. Mean values of labial enamel thickness in maxillary lateral incisors 1, 3 and 5 mm above the CEJ were $0.30{\pm}0.01$, $0.55{\pm}0.03$ and $0.80{\pm}0.02\;mm$, respectively. Conclusion: In measuring enamel thickness, microCT is one of useful way of measurement. So according to the results of this research, when restoring a porcelain laminate veneer on maxillary incisors in Koreans, careful consideration is needed in the amount of enamel reduction.

Comparison of Lens Dose in accordance with Bismuth shielding and Patient position in Brain perfusion CT (Brain Perfusion CT에서 Bismuth 차폐와 환자의 자세 변화에 따른 수정체 선량 비교 연구)

  • Gang, Eun Bo
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.1
    • /
    • pp.47-52
    • /
    • 2018
  • Brain perfusion CT scanning is often employed usefully in clinical conditions as it accurately and promptly provides information about the perfusion state of patients having acute ischemic stroke with a lot of time constraints and allows them to receive proper treatment. Despite those strengths of it, it also has a serious weakness that Lens may be exposed to a lot of dose of radiation in it. In this study, as a way to reduce the dose of radiation to Lens in brain perfusion CT scanning, this researcher conducted an experiment with Bismuth shielding and change of patients' position. TLD (TLD-100) was placed on both lens using the phantom (PBU-50), and then, in total 4 positions, parallel to IOML, parallel to IOML (Bismuth shielding), parallel to SOML, and parallel to SOML (Bismuth shielding), brain perfusion scanning was done 5 times for each position, and dose to Lens were measured. Also, to examine how the picture quality changed in different positions, 4 areas of interest were designated in 4 spots, and then, CT number and noise changes were measured and compared. According to the results of conducting one-way ANOVA on the doses measured, as the significance probability was found to be 0.000, so there was difference found in the doses of radiation to crystalline lenses. According to the results of Duncan's post-hoc test, with the scanning of being parallel to IOML as the reference, the reduction of 89.16% and 89.66% was observed in the scanning of being parallel to SOML and that of being parallel to SOML (Bismuth shielding) respectively, so the doses to Lens reduced significantly. Next, in the scanning of being parallel to IOML (Bismuth shielding), the reduction of 37.12% was found. According to the results, reduction in the doses of radiation was found the most significantly both in the scanning of being parallel to SOML and that of being parallel to SOML (Bismuth shielding). With the limit of the equivalent dose to Lens as the reference, this researcher conducted comparison with the dose to occupational exposure and dose to Public exposure in the scanning of being parallel to IOML and found 39.47% and 394.73% respectively; however in the scanning of being parallel to SOML (Bismuth shielding), considerable reduction was found as 4.08% and 40.8% respectively. According to the results of evaluation on picture quality, every image was found to meet the evaluative standards of phantom scanning in terms of the measurement of CT numbers and noise. In conclusion, it would be the most useful way to reduce the dose of radiation to Lens to use shields in brain perfusion CT scanning and adjust patients' position so that their lens will not be in the field of radiation.

Verification of Radiation Therapy Planning Dose Based on Electron Density Correction of CT Number: XiO Experiments (컴퓨터영상의 전자밀도보정에 근거한 치료선량확인: XiO 실험)

  • Choi Tae-Jin;Kim Jin-Hee;Kim Ok-Bae
    • Progress in Medical Physics
    • /
    • v.17 no.2
    • /
    • pp.105-113
    • /
    • 2006
  • This study peformed to confirm the corrected dose In different electron density materials using the superposition/FFT convolution method in radiotherapy Planning system. The experiments of the $K_2HPO_4$ diluted solution for bone substitute, Cork for lung and n-Glucose for soft tissue are very close to effective atomic number of tissue materials. The image data acquisited from the 110 KVp and 130 KVp CT scanner (Siemes, Singo emotions). The electron density was derived from the CT number (H) and adapted to planning system (Xio, CMS) for heterogeneity correction. The heterogeneity tissue phantom used for measurement dose comparison to that of delivered computer planning system. In the results, this investigations showed the CT number is highly affected in photoelectric effect in high Z materials. The electron density in a given energy spectrum showed the relation of first order as a function of H in soft tissue and bone materials, respectively. In our experiments, the ratio of electron density as a function of H was obtained the 0.001026H+1.00 in soft tissue and 0.000304H+1.07 for bone at 130 KVp spectrum and showed 0.000274H+1.10 for bone tissue in low 110 KVp. This experiments of electron density calibrations from CT number used to decide depth and length of photon transportation. The Computed superposition and FFT convolution dose showed very close to measurements within 1.0% discrepancy in homogeneous phantom for 6 and 15 MV X rays, but it showed -5.0% large discrepancy in FFT convolution for bone tissue correction of 6 MV X rays. In this experiments, the evaluated doses showed acceptable discrepancy within -1.2% of average for lung and -2.9% for bone equivalent materials with superposition method in 6 MV X rays. However the FFT convolution method showed more a large discrepancy than superposition in the low electron density medium in 6 and 15 MV X rays. As the CT number depends on energy spectrum of X rays, it should be confirm gradient of function of CT number-electron density regularly.

  • PDF

QUANTITATIVE ASSESSMENT OF NASAL AND UPPER LIP CHANGES AFTER LE FORT I OSTEOTOMY SURGERY USING A 3-DIMENSIONAL COMPUTED TOMOGRAPHY (르포씨 1형 골절단술후 코와 상순의 연조직 변화의 삼차원 컴퓨터 단층촬영을 이용한 정량적 측정에 관한 연구)

  • Lee, Won-Deok;Yoo, Chung-Kyu;Choi, Jin-Young
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.32 no.1
    • /
    • pp.49-56
    • /
    • 2010
  • Objective: To evaluate nasal and upper lip changes after Le Fort I surgery by means of images taken with a three-dimensional computed tomography (3D-CT). Methods: Fifteen patients (9 female and 6 male, mean age 21.9 years) with preoperative and postoperative 3D-CT were studied. The patients underwent maxillary movement with impaction or elongation, and advancement or setback. With the 3D-CT which presents reconstructive soft tissue images, preoperative and postoperative measurement and analysis were performed for nasal tip projection angle, columellar angle, supratip break angle, nasolabial angle, interalar width, internostril width, columella length and nasal tip projection. Results: Postoperative interalar and internostril widening was significant for all categories of maxillary movement. However, there was little significant relation in all parameters between the amount and direction of maxillary movement. Interestingly, movement of the maxilla with upward did show a little decrease in the columellar angle, supra tip break angle and nasolabial angle. Also movement of the maxilla with forward did show a little advancement in the upper lip position. Conclusion: Changes to the nose clearly occur after orthognathic surgery. There was a significant increase in postoperative interalar width and internostril width with maxillary movement. However, no clear correlation could be determined between amount of change and maxillary movement. Interestingly, maxillary impaction did show a little decrease in the columellar angle, supra tip break angle and nasolabial angle. In addition, we used 3D-CT for more precise analysis as a useful tool.

Evaluation of PET Image for Fluorine-18 and Gallium-68 using Phantom in PET/CT (PET/CT에서 Phantom을 이용한 Fluorine-18, Gallium-68 방사성 핵종의 PET 영상 평가)

  • Yoon, Seok-Hwan
    • Journal of radiological science and technology
    • /
    • v.41 no.4
    • /
    • pp.321-327
    • /
    • 2018
  • The purpose of this study is to compare PET imaging performance with Fluorine-18 ($^{18}F$) and Gallium-68 ($^{68}Ga$) for influence of physical properties of PET tracer. Measurement were performed on a Siemens Biograph mCT64 PET/CT scanner using NEMA IEC body phantom and Flangeless Esser PET phantom containing filled with $^{18}F$ and $^{68}Ga$. Emission scan duration(ESD) was set to 1, 2, 3, 4 and 5min/bed for $^{68}Ga$ and 1min/bed for $^{18}F$. The PET image were evaluated in terms of contrast, spatial resolution. Under same condition, The percentage of contrast recovery measured in the phantom ranged from 16.88% to 72.56% for $^{68}Ga$ and from 27.51% to 74.43% for $^{18}F$ and The FWHM value to evaluate spatial resolution was 10.96 mm for $^{68}Ga$ and 9.19 mm for $^{18}F$. For this study, $^{18}F$ produces better image contrast and spatial resolution than $^{68}Ga$ due to higher positron yield and lower positron energy ($^{18}F$: 96.86%, 633.5 keV, $^{68}Ga$: 88.9%, 1899 keV), The physical properties of PET tracer effect on the PET image. $^{68}Ga$ image applying ESD of 3, 4, 5min/bed were showed similar to $^{18}F$ image with ESD of 1min/bed. This study suggests that increasing ESD for acquiring $^{68}Ga$ PET image seem to be similar to $^{18}F$ image.

Comparison of Estimated and Measured Doses of Dual-energy Computed Tomography (Dual-energy 컴퓨터단층촬영에서 장비 제공선량과 측정선량 비교)

  • Kim, Yung-Kyoon;Kim, Yon-Min
    • Journal of radiological science and technology
    • /
    • v.41 no.5
    • /
    • pp.405-411
    • /
    • 2018
  • We will provide basic data on the evaluation of patient dose in terms of DECT quality control by comparing the equipment-provided dose with the measured dose according to the configuration method of the X-ray generator by the manufacturer of the dual-energy CT unit. For computed tomography (CT) equipment, Discovery 750HD, Aquilion ONE GENESIS Edition, and Somatom Definition Flash were used. The $CTDI_{vol}$ value was measured by inserting the Unfors Xi ion chamber into a 32 cm PMMA acryl Phantom. The results of estimated $CTDI_{vol}$ DECT and measured $CTDI_{vol}$ showed that the dose difference between DECT 80 + 140 kVp of G company was at least 0.51% and -1.90% max, and measured $CTDI_{vol}$ was slightly lower (p<0.05). The difference of 80 + 140 kVp of S company was the minimum of 5.84% and the maximum of 7.52% (p<0.05). The measured $CTDI_{vol}$ was less than estimated $CTDI_{vol}$. The C company's 80 + 135 kVp showed a difference of at least 7.58% and a maximum of 13.58% (P<0.05), and all of measured $CTDI_{vol}$ was less. The linearity of exposure dose for all DECT equipment was very linearly reflected with $R^2$ being 0.97 or above, and the measured dose of the ionization chamber was less than the predicted dose of the monitor.

Solution to Decrease Spatial Dose Rate in Laboratory of Nuclear Medicine through System Improvement (시스템 개선을 통한 핵의학 검사실의 공간 선량률 감소방안)

  • Moon, Jae-Seung;Shin, Min-Yong;Ahn, Seong-Cheol;Yoo, Mun-Gon;Kim, Su-Geun
    • Quality Improvement in Health Care
    • /
    • v.20 no.1
    • /
    • pp.60-73
    • /
    • 2014
  • Objectives: This study aims at decreasing spatial dose rate through work improvement whilst spatial dose rate is the cause of increasing personal exposure dose which occurs in the process of handling radioisotope. Methods: From February 2013 until July 2013, divided into "before" and "after" the improvement, spatial dose rate in laboratory of nuclear medicine was measured in gamma image room, PET/CT-1 image room, and PET/CT-2 image room as its locations. The measurement time was 08:00, 12:00 and 17:00, and SPSS 21.0 USA was opted for its statistical analysis. Result: The spatial dose rate at distribution worktable, injection table, the entrance to the distribution room, and radioisotope storage box, which had showed high spatial dose rate, decreased by more than 43.7% a monthly average. The distribution worktable, that had showed the highest spatial dose rate in PET/CT-1 image room, dropped the rate to 42.3% as of July. The injection table and distribution worktable in the PET/CT-2 image room also showed the decline of spatial dose rate to 89% and 64.4%, respectively. Conclusion: By improving distribution process and introducing proper radiation shielding material, we were able to drop the spatial dose rate substantially at distribution worktable, injection table, and nuclide storage box. However, taking into account of steadily increasing amount of radioisotope used, strengthening radiation related regulations, and safe utilization of radioisotope, the process of system improvement needs to be maintained through continuous monitoring.