• Title/Summary/Keyword: Measurement Angle

Search Result 2,169, Processing Time 0.027 seconds

Development of Wire Clamping Transfer Mechanism for Tapered Helical Shape (테이퍼진 나선가공 연삭기를 위한 와이어 클램핑 이송기구의 개발)

  • Eun, Suin;Maeng, Heeyoung
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.26 no.2
    • /
    • pp.257-261
    • /
    • 2017
  • Drilling file is medical mini-drill which is made of Ni-Ti material and has tapered shape. It's for removing teeth nervine which helps the endodontic treatment. All files, saled at domestic market, are imported from U.S. and Europe. Also they have low manufacturing efficiency and high price because it is made by universal 5 axis CNC grinding machine. To solve these problem, 3 axis CNC table, controllable tilting angle spindle and helix angle moving table are devised. To confirm divised CNC grinding machine's manufacturing accuracy, conveying amount and finish product size measurement expreiment has been practiced. Also to automate all manufacturing processes, automatic mechanism is designed.

A Study on the Duration of the Horizontal Saccadic Eye Movement (수평 saccadic 안구운동의 지속시간에 관한 연구)

  • 김광수;김용우
    • Journal of Biomedical Engineering Research
    • /
    • v.6 no.2
    • /
    • pp.23-28
    • /
    • 1985
  • In this paper, the the duration of horizontall saccadic eye movement is studied alls measurement system is designed using microprocessor to obtain the quantitized data The duration is measured using the beginning and ending points of the saccadic velocity threshold. The results obtained are as follows. 1. The average duration of the saccade for angle displacement of 0$^{\circ}$ to 20$^{\circ}$ lies between 25 and 60 msec, and represents the increasing curve except 9$^{\circ}$ and 12$^{\circ}$ 2. The average duration lfor angle displacement of 5$^{\circ}$,10$^{\circ}$,15$^{\circ}$, and 20$^{\circ}$ is 40, 48, 57.5, and 62 msec, respectively. 3. Nasal movement has a little longer duration than temporeal movement. 4. The duration is not concerned with subject's will.

  • PDF

Effect of Fabirc Structure on the Mechanical Properties of Shingosen Fabric (직물구조가 신합섬 직물의 역학적 특성에 미치는 영향 (I) 직물밀도 및 감량가공이 전단특성에 미치는 영향)

  • 서문호
    • Proceedings of the Korean Fiber Society Conference
    • /
    • 1994.10a
    • /
    • pp.11-11
    • /
    • 1994
  • A new theoretical fabric shear model has been presented and a quantitative study has been conducted on the shear properties of polyethylene(terephthalate)(PET) fabrics of four different fabric densities and five different weight reduction. The fabric shear properties were measured with KES-F handle measurement system. From the theoretical and experimental studies, following results can be summarized : 1) The fabric shear behavior is strongly dependent on the fabric density and free volume available for the constituent yarns and their filament. 2) Shear hysteresis at the small shear angle(2HG) is dependent more on the yarn tensile properties than on the fabric structure. 3) Shear hysteresis at the shear angle, 5(2HG5) is dependent more on the interaction between two crossing yarns which is directly related on the fabric structure than on the yarn tensile properties.

  • PDF

An Experimental Study on the Drop Distribution and the Combustion Characteristics with different Bluff-body Geometries (보염기 형상에 따른 연료액적분포와 연소특성에 관한 실험적 연구)

  • Hwang, S.H.;Kim, D.J.
    • Journal of ILASS-Korea
    • /
    • v.9 no.2
    • /
    • pp.1-8
    • /
    • 2004
  • This work was performed to investigate the distribution of the fuel droplet size around the bluff-body and the combustion characteristics. The geometry of the bluff-body influenced the spray shape and the combustion characteristics. Diameters of the bluff-body in this experiment are 6, 8, and 10 mm and the impingement $angles({\theta})\;are\;30^{\circ},\;60^{\circ},\;and\;90^{\circ}$. The measurement points were at the distances of 20 and 30 mm axially from the nozzle. The SMD and Rosin-Rammler distribution was acquired by image processing technique (PMAS), and the mean temperatures were measured by thermocouple. The results obtained are as follows; In the condition of ${\theta}=60^{\circ}$, the values of SMD are not greatly varied compared to the other conditions. As the impingement angle of bluff-body was increased, the high temperature region was wider along radial direction. When the air-fuel ratio was increased, the CO concentration was decreased.

  • PDF

A Case Report of Structual Scolosis (연소형 구조적 척추 측만증 환자의 치험례 보고)

  • Yeo, Eui-Ju;Han, Jae-Kyung;Kim, Yun-Hee
    • Journal of Haehwa Medicine
    • /
    • v.15 no.2
    • /
    • pp.207-210
    • /
    • 2006
  • Objective: This study was to investigate the effect of oriental medical treatment for Structual scolosis. Methods: This patient has scoliosis was treated with Herbal medicine, acupuncture and chuna therapy. And we evaluated the case with radiological measurement by calculating the scoliosis correction angle. Results: After the treatment, the cobb'angle of T-spine was changed 15" to 3". Conclusions: We report the good result of oriental medical treatment on this case. The more study of oriental medical treatment for Structual scolosis is needed.

  • PDF

Characterization of Surface Modified Polysulfone Membranes with Various Fluorine Chemicals

  • Lee, Choong-Sub;Rhim, Ji-Won
    • Korean Membrane Journal
    • /
    • v.4 no.1
    • /
    • pp.20-24
    • /
    • 2002
  • The surface of polysulfone membranes has been modified using the fluorine chemicals, ITFE (2-iodo-1,1,1-trifluoro-ethane F.W.=209.94) and PFPI (1H,1H-pentafluoro-n-propyl iodide F.W.=259.95), and PFI (1H,1H,2H,2H-perfluorohexyl iodide, F.W.=373.99) based on Friedel-Crafts reaction mechanism with varying reaction temperatures, reaction time, and catalysis types. The resulting membranes were characterized through mainly the contact angle measurement and pure water permeability. The smaller reactant shows the larger contact angles. FeBr$_3$ catalyst is more effective than AlCl$_3$. Typically, the PS film treated with ITFE at $25^{\circ}C$ under FeBr$_3$ catalyst showed the contact angle 78.5$^{\circ}C$ which indicated 10% over the value of unreacted PS films. More than 50% of pure water flux 8.0 g/$m^2$hr, reduced at reaction time 10 min relative to the original flux, 3.49 g/$m^2$hr.

A Study on The Rotor Position Detection of Bifilar-Wound Hybrid Stepping Motors (복권형 하이브리드 스테핑 전동기의 회전자 위치 검출에 대한 연구)

  • Yu, K.N.;You, J.-Bong;Woo, K.J.
    • Proceedings of the KIEE Conference
    • /
    • 1997.07a
    • /
    • pp.187-191
    • /
    • 1997
  • In this paper, we show that the rotor position of the bifilar-wound hybrid stepping motors for the closed-loop drives is detected by the phase current measurement. We propose an instantaneous phase current equation, which is the function of electrical angle, by the modeling of the stepping motor including motor driving circuits. We also analyze the relationship between phase current and rotor position from the computer simulation results. It is shown that the information about the rotor position is obtained from the phase current amplitude and its derivatives at the instance of ${\pi}/2$ electrical angle of excitation voltage.

  • PDF

Resistive shunt with low phase angle under harmonic effect (고조파 영향에 의한 위상 변화가 적은 분류기)

  • Lee, J.H.;Park, Y.T.;Lee, M.M.;Seo, J.H.;Jang, S.M.
    • Proceedings of the KIEE Conference
    • /
    • 1997.07a
    • /
    • pp.285-287
    • /
    • 1997
  • An AC shunt with low phase angle has been designed for an AC current measurement, such as currents with harmonics. This $0.2\;{\Omega}$ shunt of 5 A rated current is composed of fifty $10\;{\Omega}$ metal film resistors and applicable to the frequency band of DC to 1 kHz.

  • PDF

Measurement of Velocity Profile in Liquid Metal Flow Using Electromagnetic Tomography (전자기 토모그래피를 이용한 액체 금속 속도장 측정)

  • Choi, Sang-Ho;Ahn, Yeh-Chan;Kim, Moo-Hwan
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.1749-1754
    • /
    • 2004
  • In order to measure non-intrusively velocity profile in liquid metal flow, a modified electromagnetic flowmeter was designed, which was based on electromagnetic tomography technique. Under the assumption that flow is fully-developed, axisymmetric and rectilinear, the velocity profile was reconstructed after the flowmeter equation, the first kind of Fredholm integration equation, was linearized. In reconstruction process Tikhonov regularization method with regularization parameter was used. The reconstructed velocity profile had the nearly same as turbulent flow profile which was approximately represented as log law. In addition, flowmeter output for a fixed magnet rotation angle was linearly proportional to flow rate. When magnet rotation angle was $54^{\circ}$, axisymmetric weight function was nearly uniform so that the flowmeter gives a constant signal for any fully-developed, axisymmetric and rectilinear profile with a constant flow rate.

  • PDF

A study of measurement on range of arm joint motion of Korean male in twenties (한국인 20대 청년의 팔 관절 동작범위 측정 연구)

  • 이영신;이석기;김철중;박세진
    • Journal of the Ergonomics Society of Korea
    • /
    • v.15 no.1
    • /
    • pp.39-52
    • /
    • 1996
  • This paper measured the range of arm joint motion for Korean 54 males in twenties. The range of the arm joint motion of the subjects was measured directly using Goniometer and protractor. The number of the static and the dynamic anthropometric variables are seven and thirteen, respectively. The anthropometric data are analyzed by basic statistical analysis (four group), correlation analysis and regression analysis using commercial SAS program. The results of analysis are compared with American students anthropometric data by Laubach(1978). Thin subjects have larger movement angle as wrist flexion, wrist abduction, elbow flexion, and elbow wupination and have smaller as wrist adduction and shoulder flexion. Fat subjects have larger movement angle as shoulder flexion and are smaller wrist abduction, elbow flexion, pronation, shoulder extension, shoulder adduction, shoulder abduction, and shoulder medial rotation Korean are more flexible than American in wrist and ranges of elbow flexion and elbow rotation. The shoulder movement is similar to that of American, but shoulder flexion is less flexible.

  • PDF