• Title/Summary/Keyword: Measurement Angle

Search Result 2,166, Processing Time 0.037 seconds

Change of Reliability for Distal Metatarsal Articular Angle Measurement before and after Proximal Chevron Osteotomy (근위 갈매기 절골술 시행 전과 후의 원위 중족골 관절면각의 측정에 대한 신뢰성의 변화)

  • Park, Chul Hyun;Lee, Dong Yeol
    • Journal of Korean Foot and Ankle Society
    • /
    • v.20 no.4
    • /
    • pp.145-151
    • /
    • 2016
  • Purpose: To evaluate the reliability of preoperative and postoperative distal metatarsal articular angle (DMAA) measurements and to determine whether such reliability is different in accordance with the foot and ankle fellowship and the number of years in practice. Materials and Methods: Between July 2012 and June 2014, a total of 20 patients (24 feet) were treated with proximal chevron osteotomy and distal soft tissue procedure for symptomatic hallux valgus deformity. DMAA were measured twice with an interval of two weeks between the preoperative and postoperative dorsoplantar radiographs by four observers; two of whom were foot and ankle surgeons (A and B), one knee surgeon, and one senior resident. The intraobserver reproducibility and interobserver reliability were assessed by intraclass correlation coefficients. Moreover, the limit of agreement between the preoperative and postoperative DMAA measurements were assessed using a Bland-Altman plot. Results: The intraobserver reproducibility of the foot and ankle surgeon A, knee surgeon, and senior resident improved from 0.796, 0.575, and 0.586 preoperatively to 0.968, 0.864, and 0.864 postoperatively, respectively. The interobserver reliability of foot and ankle surgeon A-B, foot and ankle surgeon A-knee surgeon, and foot and ankle surgeon A-senior resident improved from 0.874, 0.688, and 0.677 preoperatively to 0.971, 0.917, and 0.838 postoperatively, respectively. Conclusion: The intra- and interobserver reliabilities for DMAA measurement improved after proximal chevron osteotomy. Therefore, the necessity of additional procedures to correct the increased DMAA should be reevaluated after proximal chevron osteotomy in the hallux valgus with an increased DMAA.

Polymerization and Characterization of Ophthalmic Polymer Containing Glycerol dimethacrylate with High Wettability (Glycerol dimethacrylate를 포함한 고습윤성 안의료용 고분자의 중합 및 특성)

  • Cho, Seon-Ahr;Kim, Tae-Hun;Sung, A-Young
    • Journal of the Korean Chemical Society
    • /
    • v.55 no.2
    • /
    • pp.283-289
    • /
    • 2011
  • This study used glycerol dimethacrylate with the cross-linker EGDMA (ethylene glycol dimethacrylate), HEMA (2-hydroxyethyl methacrylate), MMA (methyl methacrylate), MA (methacrylic acid) and the initiator AIBN (azobisisobutyronitrile) for copolymerization. Measurement of the physical properties of the copolymerized polymer showed that the water content was 22~32%, refractive index was 1.442~1.463 and visible ray transmittance 90.0~90.5% while the contact angle showed a distribution between 56 and $65^{\circ}$. Also, the measurement showed that the decreased amount of contact angle of the copolymer measured using the sessile drop method ranged between $9.89^{\circ}$ and $18.99^{\circ}$ with increase of glycerol dimethacrylate. Based on the results of this study, the produced copolymer is suitable for use as a material to high wettability ophthalmic lenses.

A Study on the bioactive surface modification of PEEK intervertebral fusion cage using various coating techniques (다양한 코팅 처리에 의한 PEEK 추간체유합보형재의 생체 활성 표면에 관한 연구)

  • Su-Bin Noh;Su-Zy Park;Mun-Hwan Lee
    • Journal of the Korean institute of surface engineering
    • /
    • v.56 no.4
    • /
    • pp.273-282
    • /
    • 2023
  • In this study, the surface of Polyetheretherketone (PEEK) disks was modified to have a hydrophilic surface by applying a coating of Polyethylene glycol (PEG), Hyaluronic acid(HA), and Poly-Dopamine(PDA). The investigation aimed to examine whether the coated surfaces showed enhanced bioactivity for orthopedic applications compared to the pure PEEK. The microstructure, surface characteristics, and wettability of PEEK coated with PEG, HA, and PDA were analyzed using scanning electron microscopy(SEM), FT-IR spectrophotometer, Roughness Measurement System, Micro-Vickers, and Contact angle measurement. The mechanical properties were analyzed using a tensile testing machine, while the MTT assay for cell activity was analyzed using a microplate reader to measure optical density. According to the SEM and FT-IR results, the composition and crystal structure of PEG, HA and PDA coated surface were verified. Also, roughness, hardness, and contact angle were all improved in the coating group compared to the pure PEEK. We checked the HepG2 cell proliferation by using MTT assay on 7th days. In MTT assay results, HepG2 cell proliferation was increased with time, at 7 days, cell viability on discs coated with PDA was significantly higher than pure PEEK, PEG, HA coated group. PDA coated PEEK exhibited the highest surface roughness, hardness, contact angle, and cell activity. The mechanical properties were not affected by the presence of the coating.

A study on the brilliance by critical angle of gem and measurement theory of refractive index using refractometer (보석의 임계각에 따른 휘광성 및 굴절계를 이용한 굴절률 측정 이론에 관한 연구)

  • Moon, So-I;Seok, Jeong-Won
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.21 no.3
    • /
    • pp.105-109
    • /
    • 2011
  • Critical angle of quartz (R.I. ${\fallingdotseq}$ 1.553) and diamond (R.I. = 2.417) are $40.09^{\circ}$ and $24.26^{\circ}$ that calculated by $sin{\theta}=r_2/r_1$ (r = refractive index, $r_1$ > $r_2$). Brilliance of quartz and diamond are 20.33% and 55.07%. The brilliance data are result of study on the incident light internal round brilliant cut quartz and diamond by the critical angle. Cause of bow-tie phenomenon can be studied by application of critical angle theory and light path inside fancy shape brilliant cut. When refractormetry with typical gem refractometer, critical angle of quartz and corundum are $59.1^{\circ}$ and $77.9^{\circ}$.

ROENTGENOCEPHALOMETRIC STUDY ON THE TEETH AND SKULL (치아 및 두개골에 대한 두부방사선 계측학적 연구)

  • Son, Byung Hwa
    • The korean journal of orthodontics
    • /
    • v.5 no.1
    • /
    • pp.57-63
    • /
    • 1975
  • For the purposes of augmentation of the aid for case analysis and diagnosis of malocclusion, a roentgenocephalometric study was made from 84 Korean adolescences. The Subjects consist of 42 males and 42 females aged from 17 to 20 years with normal occlusion and acceptable facial appearance. The author measured 18 angles and 14 linear distances as suggested by Jarabak. The following results were obtained. 1) Each linear measurement of the males' skull was greaten than that of the females. 2) The posterior to anterior facial height was $69.2\%$ in the males and $67.1\%$ in the females. 3) In the relationship of upper lip to esthetic line, the lip of females was more behind than that of males. 4) Saddle angle was $124.7^{\circ}$, articular angle was $148.7^{\circ}$, genial angle was $119.4^{\circ}$ and upper and lower genial angles were $45.1^{\circ}\;(N-Go-a^{\circ})$ and $74.2^{\circ}\;(N-Go-Me^{\circ})$. 5) The ratio of mandibular body to anterior cranial base was about 1:1. 1. 6) The angulations of $SNA^{\circ},\;SNB^{\circ}\;and\;SNP^{\circ}$ were as follows; $SNA^{\circ},\;80.3^{\circ},\;SNB^{\circ},\;79.8^{\circ},\;SNP^{\circ},\;81.1^{\circ}$. 7) The angle of the sella-nasion plane to the mandibular plane $(SNG^{\circ}Me^{\circ})$ was $32.0^{\circ}$ and that of the occlusal plane to the mandibular plane was $18.2^{\circ}$. 8) The angle of the maxillary central incisor to the sellanasion plane $(1-SN^{\circ})$ was $105.6^{\circ}$. That of the mandibular central incisor to the mandibular plane $(1-GoMe^{\circ})$ was $94.0^{\circ}$, and the interincisal angle $(1\;to\;1^{\circ})$ was $127.6^{\circ}$. 9) The linear distance from incisal edge of upper central incisor to facial plane was 8.0mm and that of lower central incisor was 4.6mm. 10) In the relationship of the lower lip to the esthetic line, the lower lip was 0.2mm front of the esthetic line.

  • PDF

A Study on the Machinability of Titanium (티타니움의 절삭성에 관한 연구)

  • Cheong, Seong-Gyu;Oh, Seok-Hyung;Seo, Nam-Seob
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.6 no.2
    • /
    • pp.40-46
    • /
    • 1989
  • Recently, the researches on cutting the new material have been done for development of aerospace industrial engineering. Especially, titanium ally is well known as heat resisting, antiwear, anticorrosion and difficult-to-machine materials. Many studies on the analysis of shear angle have been done for improving productivity in cutting these materials. In case of titanium alloy, the saw-toothed type of chip which has wave surface of a triangular form, an eccentric from of a continuous type of chip that is produced in the cutting process, was checked. Nakayama supposed that a maximum shear strewss plane and the shear crack in the free surface made an angle of $45^{\circ}$ .deg. , but it's usually much larger than that. In this paper, the author analyzed the shear conditions of the cutting process in the quick-stopping device with the help SEM-photographs, and measured the hypotenuse angle directly in the photographs of the chips. In conclusion, the author tried to find the shear angle in the cutting process with the saw-toothed chip and compared it with the shear angles which can be calculated from the theories established by others. The results obtained are as follows. 1. In case of the saw-toothed chips, the equivalent cutting ratio can be calculated by using the chip thickness to two-thirds of ramp height. 2. The theory of Ernst-Merchant is not applicable to the titanium and its alloys which does not fractured in accordance with the theory of maximum shear stress. 3. When we cut the titanium alloys which produced the saw-toothed chips, the shear angle can be found with the theories of Rowe-Spick, P.K. Wright and the measurement of hypotenuse angle.

  • PDF

A Study on Gait Imbalance Evaluation System based on Two-axis Angle using Encoder (인코더를 이용한 2축 각도 기반 보행 불균형 평가 시스템 연구)

  • Shim, Hyeon-min;Kim, Yoohyun;Cho, Woo-Hyeong;Kwon, Jangwoo;Lee, Sangmin
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.21 no.5
    • /
    • pp.401-406
    • /
    • 2015
  • In this study, the gait imbalance evaluation algorithm based on two axes angle using encoder is proposed. This experiment was carried out to experiment with a healthy adult male to 10 people. The device is attached to the hip and knee joint in order to measure the angle during the gait. Normal and imbalance gait angle data were measured using an encoder attached to the hip and knee joints. Also, in order to verify the reliability of estimation of asymmetrical gait using hip and knee angle, it was compared with the result of asymmetrical gait estimation using foot pressure. SI (Symmetry Index) was used as an index for determining the gait imbalance. As a result, normal gait and 1.5cm imbalance gait were evaluation as normal gait through SI using an encoder. And imbalance gait of 3cm, 4cm, and 6cm were judge by imbalance gait. Whereas all gait experiments except normal gait were evaluation as imbalance gait through SI using the pressure. It was possible to determine both the normal gait and imbalance gait through measurement for the angle and the pressure.

The effect of Westergren tube angle, temperature and osmobility with the different percent of NaCl solution on erythrocyte sedimentation rate (적혈구 침강속도에 대한 Westergren tube 각도, 온도 및 NaCl 농도가 미치는 영향)

  • Kim, Do-kyun;Kim, Young-hong;Yu, Chang-jun
    • Korean Journal of Veterinary Research
    • /
    • v.36 no.1
    • /
    • pp.75-82
    • /
    • 1996
  • Erythrocyte sedimentation rate is influenced by plasma protein, red cell itself and physiological conditions and it is clear that the measurement of erythrocyte sedimentation rate varies with technique and various environmental factors. The effect of temperature, angle of test tube, and osmobility with different percent of NaCl solution on erythrocyte sedimentation rate on sheep was determined by modified Westergren method. In sheep, as the angle of Westergren tube was decreased from $90^{\circ}$ to $45^{\circ}$, erythrocyte sedimentation rate was increased in both diluted plasma and NaCl solutions. As temperature was increased from $4^{\circ}C$ to $20^{\circ}C$ at $45^{\circ}$ angle. erythrocyte sedimentation rate was increased. In ruminants, this modified Westergren methods, erythrocyte 1 : plasma 9 instead of erythrocyte 4 : plasma 6(whole blood), enable them to have meanings as dog therefor, using this method, clinical can determine the erythrocyte sedimentation rate of ruminants for diagnosis. Because erythrocyte sedimentation rate was changed according to the angle of Westergren tube, temperature as erythrocyte diluted with NaCl, this study detected that the change of temperature, the angle of Westergren tube could change erythrocyte sedimentation rate by effecting red cell itself. The increase of osmobility owing to change of NaCl percent resulted in the decrease of rapid erythrocyte sedimentation rate. So this fact indicate that deformibility and the change of red cell volume have meaning in the change of erythrocyte sedimentation rate.

  • PDF

Effect of Independent Suspension Function of Hiking Boots on the Stability and Load of Foot (등산화 아웃솔의 독립적 서스펜션 기능이 발의 안정성 및 부하에 미치는 효과)

  • Lee, Ki-Kwang;Choi, Chi-Sun;Eun, Seon-Deok
    • Journal of the Ergonomics Society of Korea
    • /
    • v.25 no.4
    • /
    • pp.115-119
    • /
    • 2006
  • To investigate the effects of independent suspension technology(IST) of hiking boot on the stability and load of foot, eight participants performed medial and lateral drop landing from 33.4cm height and 85cm distance to uneven surface while wearing normal & IST hiking boots. For the stability of foot during the drop landing, the balance angle & suspension angle and rearfoot angle was analyzed using high-speed video analysis. Also kinetic analysis using the force plate and insole pressure measurement was conducted to analyze vertical & breaking ground reaction force and pressure distribution. Not only the balance angle & suspension angle but also rearfoot angle was improved with IST boots for lateral drop landing. These results indicate the IST boots may have the suspension function which keeps the foot to be stable during landing. However the IST boots did not show any effect for medial landing. This might be related to the hardness of medial part of outsole. Therefore the softer outsole of medial part could be recommended. Furthermore the impact force & breaking force and insole pressure were reduced with IST boot. These results means that IST boot has not only cushioning effect but also good grip effect. Therefore the hiking boots applied the independent suspension function may help to reduce fatigue and prevent injury such as ankle sprain in hiking on uneven surface.

The Effects of Foot Position on Dynamic Stability during Squat in Female with Genu Varum (내반슬 여성의 스쿼트 운동 시 발의 위치가 동적안정성에 미치는 영향)

  • Chung, Eun-Kyo;Lim, Bee-Oh
    • The Korean journal of sports medicine
    • /
    • v.36 no.4
    • /
    • pp.207-213
    • /
    • 2018
  • Purpose : The aim of this study was to investigate the effects of foot position on dynamic stability in female with genu varum. M ethods: Eight females with genu varum participated in this study and performed the four squat exercise methods that foot position ($-45^{\circ}$, $0^{\circ}$, $+45^{\circ}$) and $0^{\circ}$ squat with band. Center of pressure (COP; anterior-posterior, medial-lateral, traveled distance, ellipse area) and ground reaction force as dynamic stability were measured using footscan system. Multivariate analysis of variance and one-way repeated analysis of variance measurement with Tukey honestly significant difference were used to identify significant differences of foot angle ($-45^{\circ}$, $0^{\circ}$, $+45^{\circ}$) and $0^{\circ}$ squat with band method. Results: In anterior-posterior COP displacement, $-45^{\circ}$ foot angle and $0^{\circ}$ squat with band were significantly showed lower than $+45^{\circ}$ foot angle squat (p=0.006). Also, in COP traveled distance, $0^{\circ}$ squat was significantly showed lower than $+45^{\circ}$ foot angle (p=0.019). During the descending phase, ground reaction force significantly showed in -45 foot angle was lower than other exercise methods. Conclusion: The $0^{\circ}$ squat with band exercise showed higher dynamic stability and $+45^{\circ}$ foot angle squat exercise showed lower dynamic stability in female with genu varum.