• 제목/요약/키워드: Measured Rate System

검색결과 2,502건 처리시간 0.034초

취침 시 환기횟수에 따른 $CO_2$ 피크치 제어에 관한 연구 (A Research on the $CO_2$ Peak Point Control According to Ventilation Rate During Sleeping)

  • 김세환;김동규;박종일
    • 설비공학논문집
    • /
    • 제21권1호
    • /
    • pp.49-54
    • /
    • 2009
  • Ventilation requirement of apartment was mandated according to building equipment standards in 2006. When ventilation unit was considering for indoor air quality maintenance, we needed energy saving and efficiency ventilation control methods. This study carried out experiment of ventilation rate 0.7 adequacy. When we lived in apartment, we assumed that sleeping time was long stayed time in unconsciousness. Experiments carried out ventilation rate 0, 0.1, 0.4 and 0.7 in environment chamber from 22 o'clock to 06 o'clock, the concentration of $CO_2$, temperature and humidity rate measured. Analyzing the results, conclusions are as follows. 1) When we sleep in bedroom, ventilation rate 0.4 meet the requirements of domestic legal standards. Conform fan of similarity law, ventilation rate 0.4 reduced power cost about 80% than 0.7. 2) In generally sleeping time 8 hours, peak point control reduced running time of ventilation unit about 43% than normal control.

고조파를 고려한 신경회로망 기반의 정태부하모델링 (Static Load Modeling Based on Artificial Neural Network and Harmonics)

  • 이종필;김성수
    • 전기학회논문지P
    • /
    • 제62권2호
    • /
    • pp.65-71
    • /
    • 2013
  • Nonlinear loads with harmonics exist in an actual power system where harmonic currents make voltage distortion. The sum of reactive power measured at individual load is different from the measured reactive power at a bus in a power system with linear and non-linear loads. In this study, ANN(artificial neural network) load modeling technique with consideration of harmonics is introduced for more accurate component load modeling and an impact coefficient is proposed for aggregation of component loads. Results of this research show more accurate load modeling method. Since precise data for power system analysis can be acquired, the proposed method will be used for power system planning and maintenance.

초음파 연료공급장치용 가솔린 분사식 자동차의 저공해화 연구 (A study on the Pollution Emissions of the Ultrasonic Fuel Feeding System in Gasoline Injection Vehicle)

  • 최관호;김봉석;류정인
    • 한국자동차공학회논문집
    • /
    • 제4권1호
    • /
    • pp.86-95
    • /
    • 1996
  • This study was on the pollution emissions of the Ultrasonic fuel feeding system in gasoline injection vehicle. This work measured th SMD of the fuel, and compared the characteristics through chassis dynamometer and highway road test by the conventional vehicle. And this work measured vacuum degree, turbulence intensity and the rate of fuel consumption according to intake air velocity with swirler. The results are as followed; The effects of the vehicle installed the ultrasonic fuel feeding system are better than those of the conventional vehicle.

  • PDF

A Development of Healthcare Monitoring System Based on Internet of Things Effective

  • KIM, Song-Eun;MUN, Ji-Hui;KIM, Kyoung-Sook;KANG, Min-Soo
    • 한국인공지능학회지
    • /
    • 제8권1호
    • /
    • pp.1-6
    • /
    • 2020
  • The Recently there has been a growing interest in health care due to the COVID-19 situation. In this paper, we intend to develop a healthcare monitoring system to provide users with smart healthcare systems in line with the healthcare 3.0 era. The system consists of a wireless network between various sensors, Android smartphones, and OLEDs using Bluetooth, and through this, a health care monitoring system capable of collecting user's biometric information and managing health by receiving data values of sensors connected to Arduino. In conclusion, the user's BPM value was calculated using the heart rate sensor, and the exercise intensity can be adjusted through this. In addition, a step derivation algorithm is implemented using an acceleration sensor, and calorie consumption can be measured using the step and weight values. As such, the heart rate, step count, calorie consumption data can be transmitted to a smartphone application through a Bluetooth module and output, and can be output to an OLED for users who are not easy to access the smartphone. This healthcare monitoring system can be applied to various groups and technologies.

갑상선 섭취율 측정에서 선원의 길이와 부피 증가에 따른 영향 (The Effect of Increase in Length and Volume of Source in Radioactive Iodine Thyroid Uptake Rate)

  • 황동훈;오신현;김정열;강천구;김재삼
    • 핵의학기술
    • /
    • 제21권1호
    • /
    • pp.70-75
    • /
    • 2017
  • 방사성 요오드 갑상선 섭취율 검사는 방사성 요오드를 투여하고 일정 시간 후 갑상선의 요오드 방사능치를 측정하여 전반적인 기능 상태를 알아보는 검사법이다. 검사에 영향을 미치는 인자는 매우 다양하다. 본 연구에서는 갑상선의 길이나 두께, 부피에 따른 기하학적 요인이 계수율에 주는 영향을 관찰하고자 한다. 액체상태의 $^{131}I\;185kBq$ ($5{\mu}Ci$)을 지름이 0.5, 1, 1.5, 3 cm 인 주사기에 넣고 길이를 1 cm 간격으로 생리식염수를 추가하여 증가시켰다. 선원을 장비로부터 25 cm 거리에서 횡축방향과 종축방향으로 위치하였을 때 각각의 계수율을 측정하였다. 횡축 방향으로 위치하였을 때, 선원의 길이가 변화하여도 대부분 유의한 차이를 보이지 않았다. 종축 방향으로 위치하였을 때, 곡선추정 회귀분석 결과 복합모형곡선과 높은 상관관계를 보였고($$R^2{\geq_-}0.941$$), 선원의 길이가 증가할수록 계수율은 감소하였다. 따라서 갑상선 섭취율 검사 시, 갑상선의 가로나 세로 방향의 차이에 따른 섭취율의 오차는 적을 것으로 예상되어 지며, 단순한 부피의 차이보다 갑상선의 두께 및 투여 전 선량측정 시의 비커에 따라서 오차가 생길 수 있다고 예상된다. 따라서 오차를 줄이기 위해서는 초음파 등의 영상을 참고하여 두께를 구해 섭취율 수치에 적용하거나, 결과에서 구한 복합방정식을 통해 오차를 예측, 갑상선과 섭취율 장비의 거리를 변화시킨다면 비교적 정확한 계수율을 구할 수 있을 거라 사료 된다.

  • PDF

호흡기류 계측모듈의 교정과 성능 비교를 위한 실용적인 표준기류 생성 시스템 (A Practical standard Air Flow Generator System to Calibrate and Compare Performance of Two Different Respiratory Air Flow Measurement Modules)

  • 이인광;박미정;이상봉;김경옥;차은종;김경아
    • 대한의용생체공학회:의공학회지
    • /
    • 제36권4호
    • /
    • pp.115-122
    • /
    • 2015
  • A standard air flow generator system was developed to generate air flows of various levels simultaneously applied to two different air flow transducer modules. Axes of two identical standard syringes for spirometer calibration were connected with each other and driven by a servo-motor. Linear displacement transducer was also connected to the syringe axis to accurately acquire the volume change signal. The user can select either sinusoidal or square waveform of volume change and manually input any volume as well as maximal flow rate levels ranging 0~3 l and 0~15 l/s, respectively. Various volume and flow levels were input to operate the system, then the volume signal was acquired followed by numerical differentiation to obtain the air flow signal. The measured volumes and maximal air flow rates were compared with the user input data. The relative errors between the user-input and the measured stroke volumes were all within 0.5%, demonstrating very accurate driving of the system. In case of the maximal flow rate, relatively large error was observed when the syringe was driven very fast within a very short time duration. However, except for these few data, most measured flow rates revealed relative errors of approximately 2%. When the measure and user-input stroke volume and maximal flow rate data were analyzed by linear regression analysis, respectively, the correlation coefficients were satisfactorily higher than 0.99 (p < 0.0001). These results demonstrate that the servo-motor controls the syringes with enough accuracy to generate standard air flows. Therefore, the present system would be very much practical for calibration process as well as performance evaluation and comparison of two different air flow transducer modules.

Effects of a tunnel ventilation system within the tie-stall barn environment upon the productivity of dairy cattle during the winter season

  • Sarentonglaga, Borjigin;Sugiyama, Tatsuhiro;Fukumori, Rika;Nagao, Yoshikazu
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제32권5호
    • /
    • pp.748-756
    • /
    • 2019
  • Objective: The objective of this study was to examine the effect of using a tunnel ventilation system within the dairy barn environment upon the productivity of dairy cows during the winter season. Methods: The study was performed at the University Farm, Faculty of Agriculture, Utsunomiya University. Twenty-one Holstein dairy cows (5 heifers and 16 multiparous) were enclosed in a stall barn. Unventilated (UV) and tunnel-ventilated (TV) was operated by turns every other week, and a number of key parameters were measured in the barn, including tunnel ventilation output, temperature, relative humidity, gas concentrations (oxygen [$O_2$], carbon dioxide [$CO_2$], and ammonia [$NH_3$]). Also, skin and rectal temperature, respiratory rate, blood gas concentrations, and bacterial count were measured from nipple attachments on ten cows. The amount of fodder left uneaten, and general components and somatic cell count of the milk were measured. Results: As for our dairy barn environment, air temperature dropped significantly with the passage of time with TV. Humidity was significantly higher with TV at 0600 h compared to UV, while $CO_2$ and $NH_3$ concentrations with UV were significantly higher than with TV at 0000 h and 0600 h. Skin temperature was significantly lower with TV compared to UV at 0000 h and 0600 h. Respiratory rate was also significantly lower at 0600 h with TV than with UV. Bacterial count for the nipple attachments was significantly lower with TV than with UV at 0600 h. The amount of leftover fodder was significantly less with TV in comparison with UV. Conclusion: Our results suggest that a TV system in the winter barn results in environmental improvements, such as reductions in unfavorable gas concentrations and bacterial growth. Consequently, it is expected that barns utilizing a TV system will be beneficial for both animal health and production.

시스템 개선을 통한 핵의학 검사실의 공간 선량률 감소방안 (Solution to Decrease Spatial Dose Rate in Laboratory of Nuclear Medicine through System Improvement)

  • 문재승;신민용;안성철;유문곤;김수근
    • 한국의료질향상학회지
    • /
    • 제20권1호
    • /
    • pp.60-73
    • /
    • 2014
  • Objectives: This study aims at decreasing spatial dose rate through work improvement whilst spatial dose rate is the cause of increasing personal exposure dose which occurs in the process of handling radioisotope. Methods: From February 2013 until July 2013, divided into "before" and "after" the improvement, spatial dose rate in laboratory of nuclear medicine was measured in gamma image room, PET/CT-1 image room, and PET/CT-2 image room as its locations. The measurement time was 08:00, 12:00 and 17:00, and SPSS 21.0 USA was opted for its statistical analysis. Result: The spatial dose rate at distribution worktable, injection table, the entrance to the distribution room, and radioisotope storage box, which had showed high spatial dose rate, decreased by more than 43.7% a monthly average. The distribution worktable, that had showed the highest spatial dose rate in PET/CT-1 image room, dropped the rate to 42.3% as of July. The injection table and distribution worktable in the PET/CT-2 image room also showed the decline of spatial dose rate to 89% and 64.4%, respectively. Conclusion: By improving distribution process and introducing proper radiation shielding material, we were able to drop the spatial dose rate substantially at distribution worktable, injection table, and nuclide storage box. However, taking into account of steadily increasing amount of radioisotope used, strengthening radiation related regulations, and safe utilization of radioisotope, the process of system improvement needs to be maintained through continuous monitoring.

광덕트방식 자연채광 시스템의 산광부에 대한 연구 (A study on lighting Diffusion system of Daylight Duct System)

  • 송규열;박경우;류한기
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2011년도 춘계 학술논문 발표대회 2부
    • /
    • pp.99-104
    • /
    • 2011
  • Daylighting system is an alternative to the energy crisis and environment change. And it is possible improvement system of Architectural Space Environment. Accordingly, it is very useful system. Because Daylight Duct System of Daylighting System gives high performance for its price, distribution rate is very high. But Daylighting Duct System is hard to accurate control. Accordingly, it is difficult to maintain continuously Daylight Environment in Interior Spaces. Lighting Diffusion System has been developed that it is Applying the principle of Reflector and prism diffuser for maximize the efficiency of lighting of Daylight Duct Systems through this study. And then compare lighting performance of Existing System and new Lighting Diffusion System through producing a mock-up. Thus, this study was carried out for the purpose of verification for excellence. It is that installed Each Daylighting Duct System for performance evaluation in a laboratory of width 4m, length 10m, height 2.5m. And illuminance was measured at noon on winter solstice(December 22) under clean sky. The actual measurement result was in the following. Newly developed lighting Diffusion system was measured maximum illuminance 399, minimum illuminance 221, average illuminance 141. Synthetically, daylight factor, uniformity factor and illuminance distribution were improved more than existing system. As a result, it was confirmed that was improved lighting Environment in Interior Spaces.

  • PDF

컴퓨터비젼을 이용한 알루미늄 캔재 이어링률 자동 측정 시스템 개발 (Development of an Auto Measuring System for the Earing Rate of Aluminum CAN Using Computer Vision)

  • 이용중;김형조;이양범
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2003년도 춘계학술대회 논문집
    • /
    • pp.288-292
    • /
    • 2003
  • The main purpose of this paper is the development of the system which measures the earing rate of aluminum CAN with the CCD camera. In order to optimize imput image, the image object was segregated and the position of the image grasped. In the pre-processing the edges were detected by the Robert mask after improving the definition of image by the histogram equalization. The height of four each ear and angles which occur due to the characteristics of the aluminum CAN are measured manually with the digital vernier calipers in the industrial ground and in the case of the velocity, these require 30 seconds at least by three times measurement per height of one direction of the aluminum. But it took 0.02 seconds when this system was applied. Therefore this system is proven the satisfactory efficiency and reliability as compared to the control result of in industrial ground.

  • PDF