• Title/Summary/Keyword: Measure of evaluation

Search Result 3,442, Processing Time 0.037 seconds

Job Satisfaction and Engagement of School Food Service Dietitians and Nutrition Teachers in Chungbuk (충북지역 학교급식 영양(교)사의 직무만족 및 몰입도)

  • Kim, Joon Young;Lee, Young Eun
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.43 no.6
    • /
    • pp.943-954
    • /
    • 2014
  • The purpose of this study was to gather basic data and measure job satisfaction and job engagement of dietitians and nutrition teachers in Chungbuk area. This study was conducted on 20 August, 2010. Out of 336 questionnaires, 266 were completed and made available for the purpose of statistical evaluation. As the main results, job satisfaction was classified into eight categories: task, wage, policies related to tasks, professional growth, promotion, relationships with colleagues, working environment, and supervision. In the case of wage, promotion, and policies related to tasks, the average scores of job satisfaction were around 2 points out of 5. Dietitians' job satisfaction levels according to employment type and school type significantly differed. In terms of job involvement and organizational commitment, average scores were 3.53 points and 3.12 points respectively. The survey showed significantly different results for job involvement and organizational commitment, depending on employment type, school type, and status as chef in charge or trainee. Dietitians working in elementary schools, as chef in charge, or with permanent employment showed higher job involvement and organizational commitment. Furthermore, there was a significantly positive correlation between factors such as task, wage, promotion, relationships with colleagues, supervision, work environment, policies related to tasks, professional growth, and job satisfaction.

Evaluation of Tissue Inhomogeneity for Gamma-knife Radiosurgery Using Film Dosimetry (감마 나이프 방사선 수술시 필름 선량 측정에 의한 조직 불균일성에 대한 연구)

  • Cho, Heung-Lae;Shon, Seung-Chang;Shu, Hyun-Suk
    • Radiation Oncology Journal
    • /
    • v.16 no.3
    • /
    • pp.325-335
    • /
    • 1998
  • Purpose : Since the mid cranial fossa is composed of various thickness of bone, the tissue inhomogeneity caused by bone would produce dose attenuation in cobalt-60 gamma knife irradiation. The correction factor for bone attenuation of cobalt-60 which is used for gamma knife source is -3.5$\%$. More importantly, nearly all the radiosurgery treatment planning systems assume a treatment volume of unit density: any perturbation due to tissue inhomogeneity is neglected, This study was performed to confirm the bone attenuation in mid cranial fossa using gamma knife. Materials and Methods : Computed tomography was performed after Leksell stereotactic frame had been liked to the Alderson Rando Phantom (human phantom) skull area. Kodak X-omat V film was inserted into two sites of pituitary adenoma point and acoustic neurinoma point, and irradiated by gamma knife with 14mm and 18mm collimator. An automatic scanning densitometer with a 1mm aperture is used to measure the dose profile along the x and y axis. Results : Isodose curve constriction in mid cranial fossa is observed with various ranges. Pituitary tumor point is greater than acoustic neurinoma point (0.2-3.0 mm vs 0.1-1.3 mm) and generally 14 mm collimator is greater than 18mm collimator (0.4-3.0 mm vs. 0.2-2.2 mm) Even though the isodose constriction is found, constriction of 50$\%$ isodose curve which is used for treatment reference line does not exceed 1 mm. This range is too small to influence the treatment planning and treatment results. Conclusion : Radiosurgery planning system of gamma knife does not show significant error to be corrected without consideration of bone attenuation.

  • PDF

Antibacterial effects of Chitosanon-ascorbate Treated Kwamaegi Prepared on Microorganism Contamination (Chitosan-ascorbate 처리 과메기에 있어서 오염미생물에 대한 저해효과)

  • Kim, Young-Sook;oh, Seung-Hee;Kim, Soon-Dong
    • KSBB Journal
    • /
    • v.24 no.2
    • /
    • pp.156-162
    • /
    • 2009
  • We examined saury, herring, gizzard shad kwamaegi to measure of microbic contamination rate of kwamegi that are sold in the market now. In the total bacteria, staphylococcus, peroxide value, and microorganisms is inhibited that from sample that we treated a substance with chitosan-ascorbate (CA) and other orders deep water (DW), ginseng steamed red and wine (GRW), NT (not treated). When we compared between SGRW and SNT, SCA show us more inhibition effect 0.22-0.49 log cycle in the total aerobacter. When we compared between HDW and HNT, HCA restraint 0.05-0.45log cycle, and when we compared between GDW and GNT, GCA inhibited 0.45 log cycle. In the coliform and E. coli, growths of microorganisms were inhibited followed order by treatment of CA, NT, and DW. GDW, HCA and HNT checked enough amount of water from the moisture measurement; but SGW, GCA, HEW and SCA showed 7-15% lack of moisture, and SNT and GNT have 10% more moisture. Peroxide value is changed to 41-51meq/kg when we did treat CA in there and a side that didn't add antimicrobial expressed the result numerically that 56-58meq/kg. In the sensory evaluation, customer gave preference to followed by Saury kwamaegi, herring, and gizzard shad kwamaegi. We have a point of view when kwamaeki manufactured if we add natural antibiotic and it uses to vacuum drying, we would inhibited of multiplication of microorganism, and of peroxides.

Tightness of specimen sealing box in 20 L test chamber to evaluate building materials emitting pollutants (건축자재에서 방출되는 오염물질 평가 시 사용되는 20 L 시험챔버 시편홀더의 기밀성 개선)

  • Shin, Woo Jin;Lee, Chul Won;Kim, Man Goo
    • Analytical Science and Technology
    • /
    • v.20 no.4
    • /
    • pp.261-267
    • /
    • 2007
  • The 20 L small chamber test method is to evaluate pollutants such as TVOC, formaldehyde emitted from building materials. This method was only designed to evaluate the surface emission of sample exposed in the chamber. In this method, building materials cut with a fixed standard size are fixed in a sample sealing box. The sample sealing box is put into the 20 L test chamber. This chamber is ventilated at a standard air change rate with purified air for 7 days then the sample from the chamber is collected and analyzed to measure the emission rate of TVOC and formaldehyde. In this method, however, if the sealing box does not guarantee airtightness, accurate evaluation for the building materials can not be achieved due to the pollutants emitted from edge of the sample so called, edge effect. This edge effect can be much greater when evaluating panels such as plywood, flooring due to their surface treatment. In this study, flooring was tested to check airtightness of the sample sealing box with analytic results between 1L and 20 L test chamber. Furniture materials like LPM coated one side surface treatment and MDF coated both sides surface treatment with LPM were tested to identify whether the improvement of the sample sealing box airtightness is possible with the comparison between existing and improved test method that low VOC emission tape was used to seal the sample edge. After 7 days, MDF TVOC emission rate was different according to the existence and nonexistence of tape. The emission rate of the existing test method was $0.009mg/m^2h$ and that of improved test method was $0.003mg/m^2h$. Relative standard deviation for the existing test method was $0.004mg/m^2h$ and relative standard deviation for the improved test method was $0.002mg/m^2h$ when the same sample was analyzed three times. The improved test method in this study using low VOC emission tape was effective and able to reduce the heterogeneous effect of the edge from the sample sealing box.

Quantitative Assessment of Myocardial Tissue Velocity in Normal Children with Doppler Tissue Imaging : Reference Values, Growth and Heart Rate Related Change (소아에서 도플러 조직영상을 이용한 최대 심근 속도의 계측 : 정상 추정치 및 성장 및 심박동수에 따른 변화)

  • Kim, Se Young;Hyun, Myung Chul;Lee, Sang Bum
    • Clinical and Experimental Pediatrics
    • /
    • v.48 no.8
    • /
    • pp.846-856
    • /
    • 2005
  • Purpose : To measure the peak myocardial tissue velocities and patterns of longitudinal motion of atrioventricular(AV) annuli and assess body weight and heart rates-related changes in normal children. Methods : Using pulsed wave Tissue Doppler Imaging(TDI), we measured peak systolic, early and late diastolic myocardial velocities in 72 normal children at six different sites in apical-4 chamber (A4C) view and at four different sites in apical-2 chamber(A2C) view and compared those values with each other, also observing effects with body weights and heart rates. Longitudinal motions of the AV annuli were measured at three different sites in A4C. Results : There were no significant differences of the TDI parameters between gender, ECHO-machines and among the three Doctors performing TDI. Peak myocardial velocities were significantly higher at the base of the heart than in the mid-ventricular region and in the right lateral ventricular wall than in the left lateral ventricular wall or IVS. The TDI parameters showed no significant correlation with fractional shortening(%). Peak systolic and early diastolic myocardial velocities had no correlation with heart rates, but peak late diastolic velocities and A/E ratio correlated positively with heart rates. Correlations between the TDI parameters and body weight were inconsistent. Absolute longitudinal displacement and % displacement were not differ between gender and not correlated with the TDI parameters. Conclusion : We measured the peak myocardial velocities with TDI and the longitudinal motion of the AV annuli using M-mode echocardiography in normal children. With more large scale evaluation, we may establish reference values in normal children and broaden clinical applicabilities in congenital and acquired heart diseases.

A Study on Significance Testing of Driver's Visual Behavior due to the VMS Message Display Forms on the Road (도로상 VMS 표출방식별 운전자 유의성 검증에 관한 연구)

  • Kum, Ki-Jung;Son, Young-Tae;Bae, Deok-Mo;Son, Seung-Neo
    • International Journal of Highway Engineering
    • /
    • v.7 no.4 s.26
    • /
    • pp.151-162
    • /
    • 2005
  • Variable Message Sign (VMS), which provides drivers with direct information about state of traffic congestion and for prevent an accident, is the most effective method among the methods of providing information in Advanced Transportation Management System. Currently establishment and the VMS which is operated foundation lets in Guidelines on the use of Variable message sign (a book of the VMS) of 1999 November the Ministry Construction & Transportation, these contents mean main viewpoint on physical part such as message special quality variable (font, character size and line space, word interval) and position mainly among standard about establishment in general. But, it is true that using without effect verification on the character of VMS display and that using mode of stationary-centered. In this paper, it executed significance test to effort verification on the character of VMS display for more practical and effective information transmission based on the driver viewpoint For the researches; develop 3D-Simulation, select characteristics of driver's visual cognition behavior (the conspicuity, the legibility and the comprehensibility), evaluation each issue (day or night, 80km/h or 100km/h). Especially, that used the Eye Marker Recorder to measure of reading-time (legibility) thus, confirmed objectivity and reduce an observational error. The results showed that the conspicuity is Flashing> Stationary>Scroll. The legibility is not deference that Flashing between stationary form. Also the comprehensibility result showed that Flashing> Stationary>Stroll form.

  • PDF

A Study on the Estimation Measure of Delay Cost on Work Zone Using the Traffic Flow Model (교통류 모형을 이용한 도로 점용공사 구간의 지체비용 산정방안)

  • Kim, Yunsik;Lee, Minjae
    • Korean Journal of Construction Engineering and Management
    • /
    • v.17 no.5
    • /
    • pp.120-129
    • /
    • 2016
  • The user cost is an important analysis item which should be considered together with life-cycle of facility, administrator cost and discount rate in LCCA for efficient asset management of SOC facilities. Especially, a significant delay cost occurs often for users in the road field due to a work zone for cleaning and maintenance, and in such case, the administrator should consider the administrator cost as well as the user cost for more rational decision making. However, the user cost has not been considered in most decision making steps until recently and relevant studies also have not been carried out actively. In this study, the methodology to estimate the user cost and delay cost required in the decision making step using the traffic flow model and the direct benefit estimation model in the traffic facility investment evaluation guideline is suggested. And, the traffic flow model was estimated on 4 national highway sections where maintenance was actually carried out in 2014 using VISSIM and, the user cost and the delay cost were estimated based on the suggested methodology. The analysis result showed that the average user cost of $17,569,000KRW/km{\times}day$ occurred on Section A with approximately 30,000 AADT before a work zone occurred, and in case the first lane was blocked for maintenance, the delay cost of $10,193,000KRW/km{\times}day$ (158%) on average occurred additionally. The delay cost of $1,507,000KRW/km{\times}day$ (115%) and $1,985,000KRW/km{\times}day$ (119%) occurred on Sections B and D with approximately 20,000 AADT respectively and the delay cost of $262,000KRW/km{\times}day$ (105%) occurred on Section C with approximately 10,000 AADT. This result of this study was estimated based on the simulation of traffic flow model so that there is a limitation in its actual application. A study ot develop a highly appropriate model using actual observation data and improve the possibility to apply it through the verification using the simulation will be necessary in future.

Body Images of Korean College Students: Based on a Cross-National Study Focusing on Korean, Chinese, and Japanese College Students. (한국 대학생의 신체이미지: 일본, 중국과의 비교를 토대로)

  • Wan-Suk Gim;Yeon-Jae Ryu
    • Korean Journal of Culture and Social Issue
    • /
    • v.18 no.2
    • /
    • pp.301-327
    • /
    • 2012
  • This study investigated body images based on the survey data drawn from college students in three East Asian countries(Korea, Japan, and China). 347 Korean, 341 Chinese, and 271 Japanese college students responded to questions designed to measure body images such as body-related values (operability, inclination, locus of evaluation, and instrumentality of appearance), body esteem (appearance, and health), and objectified body-consciousness ( surveillance and shame). The results showed that body images differ among countries. Regarding body-related values, Korean students have least conservative beliefs and followed by Japanese, and Chinese. Korean students showed the highest acceptance level for the voluntary body alteration(operability), highest inclination to body appearance over health. They also showed the strongest tendency of evaluating their body from the observer's point of view and the strongest belief about the social utility of body appearance compare to Japanese and Chinese students. Appearance- esteem of Korean was similar to Chinese but higher than Japanese. Surveillance and shame about body appearance of Korean students were similar to Japanese but higher than Chinese. Compare to male students, females showed stronger belief about the body appearance over health, lower appearance esteem, and higher surveillance and shame about body. Korean women showed the least conservative body-related values, and the levels of body appearance esteem and objectified body consciousness were located in between Japanese and Chinese women. Japanese women showed especially low body appearance esteem and highest surveillance and shame. Chinese women showed the most conservative body-related value, the highest appearance-esteem, and the lowest surveillance and shame. It was revealed that the body-related values indirectly affect to appearance-esteem through the mediating role of objectified body consciousness in Chinese and Japanese samples, but that the body-related values had direct effect on appearance-esteem as well in Korean sample.

  • PDF

Evaluation of Virtual Grid Software (VGS) Image Quality for Variation of kVp and mAs (관전압과 관전류량 변화에 대한 가상 그리드 소프트웨어(VGS) 화질평가)

  • Chang-gi Kong
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.5
    • /
    • pp.725-733
    • /
    • 2023
  • The purpose of this study is to evaluate the effectiveness of virtual grid software (VGS). The purpose of this study is to evaluate the changes in energy and object thickness by dividing the use of VGS into two cases (Without-VGS) without using a movable grid. We attempted to determine the effectiveness of VGS by acquiring images using a chest phantom and a thigh phantom and analyzing SNR and CNR. In the chest phantom and femoral phantom, the tube flow was fixed at 2.5 mAs, and the tube voltage was changed by 10 kVp from 60 to 100 kVp to measure SNR and CNR, and SNR was about 1.09 to 8.86% higher in the chest phantom than in Without-VGS, and CNR was 4.18 to 14.56% higher in the VGS than in Without-VGS. And in the femoral phantom, SNR was about 9.78 to 18.05% higher in VGS than in Without-VGS, and CNR was 21.07 to 44.44% higher in VGS than in Without-VGS. The tube voltage was fixed at 70 kVp in the chest phantom and the femoral phantom, and the amount of tube current was changed at 2.5 to 16 mAs, respectively, and after X-ray irradiation, SNR and CNR were measured in the chest phantom, which was about 1.49 to 11.11% higher in VGS than in Without-VGS, and CNR was 4.76 to 13.40% higher in VGS than in Without-VGS. And in the femoral phantom, SNR was about 2.22 to 17.38% higher in VGS than in Without-VGS, and CNR was 13.85 to 40.46% higher in VGS than in Without-VGS. Therefore, if an inspection is required with a mobile X-ray imaging device, it is believed that good image quality can be obtained by using VGS in an environment where it is difficult to use a mobile grid, and it is believed that the use of mobile X-ray devices can be increased.

Evaluation of the accuracy of the HexaPOD evo RT system using Non-coplanar beams in lung cancer (폐암환자의 비동일평면 선속 빔 치료 시 HexaPOD evo RT system 의 정확성 평가)

  • Jang, Sewuk;cho, Kangchul;Lee, Sangkyoo;Kim, Jooho;Cho, Jeonghee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.2
    • /
    • pp.115-122
    • /
    • 2015
  • Purpose : The aim of this study, evaluate the accuracy of HeaxPOD evo RT system using the non-coplanar beam. Materials and Methods : 13 treatment plans are used which applied non-coplanar beams and 10 treatment plans which coplanar beams are used. the correction value what adjust to 6D couch is determined by each patient's setup errors only rotation direction. The study executed followings. first, Applying the correction value, measure the point dose and calculate the ${\gamma}$-index(${\gamma}=3%$ / 3 mm, ${\gamma}=2%$ / 2 mm). second, acquire data as previous methods without correction by HexaPOD. Results : For comparing the two results, we find out the more precise applying HexaPOD by point dose 0.2% in coplanar and non-coplanar. in the case of ${\gamma}$-index<1(${\gamma}=3%$ / 3 mm), more precise 2.2% in coplanar and 7% in Non-coplanar. Particularly, ${\gamma}$-index<1(2% / 2 mm) show the difference 9.2% in coplanar and 15.1% non-coplanar between apply HexaPOD and dose not apply HexaPOD. Conclusion : Using the HexaPOD is more precise than without HexaPOD. It suggests that HexaPOD evo RT system is very useful for precise and high dose delivery.

  • PDF