• Title/Summary/Keyword: Measure height

Search Result 780, Processing Time 0.024 seconds

Development of Ventilation Duct Chamber for Reducing Space (공간 절약형 환기덕트를 위한 챔버 개발에 관한 연구)

  • Kim, Sang-Jin;Choi, Sang-Sik;Lee, Sung
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.535-539
    • /
    • 2008
  • The machinery ventilation system in case of using the window nature ventilation is difficult due to strong outdoor wind pressure is common ventilation measure. increasing height and decreasing economical efficiency problem because of ventilation duct installation is rising and a measure is urgent. The purpose of this study is analysis required height according to each ventilation system and development of ventilation duct system to reducing height and model testing.

  • PDF

Chip stack height measurement of semiconductor using slit beam (슬릿빔을 이용한 반도체의 칩 적층 높이 측정)

  • Shin, Gyun-Seob;Cho, Tai-Hoon
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2009.10a
    • /
    • pp.422-424
    • /
    • 2009
  • In this paper, we studied methods that measure chip stack height using slit beam in mold equipment among semiconductor manufacture equipments. We studied two methods to improve chip stack height measurement performance. First, it is relation of camera exposure time and height measurement repeatability. Second we could improve measurement performance applying method of least mean square method for measurement error minimization about PCB(Printed Circuit Board) flexure phenomenon.

  • PDF

Diagnostic Technique and Device for Railway Arresters (철도용 피뢰기 진단기술 및 장치)

  • Kil Gyung-Suk;Han Ju-Seop;Jang Dong-Uk
    • Proceedings of the KSR Conference
    • /
    • 2004.06a
    • /
    • pp.1422-1424
    • /
    • 2004
  • Various deterioration diagnostic techniques and devices are suggested, and most of which measure leakage current components as an indicator of arrester ageing. However, the techniques based on the magnitude of leakage current measure simply RMS or peak value of leakage current components and do not provide detailed information needed in the diagnosis. In this study, we found that the phase vs. wave height of total leakage current is changed or a new wave height is produced with arrester ageing. To complete the new technique, we designed an arrester diagnostic device which is composed of a current detection circuit, an optical transmission circuit, and an analysis program. After measurement of the total leakage current, magnitudes, phase vs. wave height, and harmonics of the leakage current components are analyzed by the microprocessor based device. From the experimental results, we confirmed that the device can measure most parameters needed for the arrester diagnostics and analyze an initial deterioration state.

  • PDF

Effects of Modified Low-Dye Taping on Stroke Patients with an Excessive Pronated Foot (과도하게 엎침된 발을 가진 뇌졸중 환자에게 적용된 수정 발바닥활 지지 테이핑의 효과)

  • Kim, Hyun-Wook;Ryu, Young-Uk
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.13 no.2
    • /
    • pp.69-74
    • /
    • 2018
  • PURPOSE: Stroke patients may develop an over-pronated foot, resulting in a lower medial longitudinal arch. This can lead to a structural change of the foot due to deformation of the musculoskeletal system. The purpose of this study was to examine the effects of modified low-dye taping on stroke patients with an excessively pronated foot. The effect of the taping on the foot after light daily activity was also examined. METHODS: The subjects consisted of 21 stroke patients with an excessively pronated foot, as measured by the navicular drop test. First, their navicular heights were measured at a relaxed standing position (measure 1) and while standing in the subtalar neutral position (measure 2). Modified low-dye taping was applied to each subject's affected foot and the navicular height was then measured for the standing posture (measure 3). Finally, each subject walked around for 10 minutes and the navicular height was measured again (measure 4). RESULTS: Statistical analyses showed that the navicular height value at the relaxed standing position (measure 1) was significantly lower than for the other 3 measurements. That is, the modified low-dye taping was effective in maintaining a subtalar neutral position, even after a 10-minute walk, for stroke patients with an excessively pronated foot. CONCLUSION: The results suggest that modified low-dye taping applied to stroke patients with an excessively pronated foot could be an effective way to place the subtalar joint in a neutral position, and that its effect can be sustained for light daily activities.

Adjustment Algorithms for the Measured Data of Stereo Vision Methods for Measuring the Height of Semiconductor Chips (반도체 칩의 높이 측정을 위한 스테레오 비전의 측정값 조정 알고리즘)

  • Kim, Young-Doo;Cho, Tai-Hoon
    • Journal of the Semiconductor & Display Technology
    • /
    • v.10 no.2
    • /
    • pp.97-102
    • /
    • 2011
  • Lots of 2D vision algorithms have been applied for inspection. However, these 2D vision algorithms have limitation in inspection applications which require 3D information data such as the height of semiconductor chips. Stereo vision is a well known method to measure the distance from the camera to the object to be measured. But it is difficult to apply for inspection directly because of its measurement error. In this paper, we propose two adjustment methods to reduce the error of the measured height data for stereo vision. The weight value based model is used to minimize the mean squared error. The average value based model is used with simple concept to reduce the measured error. The effect of these algorithms has been proved through the experiments which measure the height of semiconductor chips.

Development of a Contact Type Height Sensor to Measure Ground Clearance of an Agricultural Tractor (농용 트랙터용 접촉식 지상고 측정 센서 개발)

  • Lee, Choong-Ho;Lee, Je-Yong;Lee, Sang-Sik
    • Journal of Biosystems Engineering
    • /
    • v.33 no.1
    • /
    • pp.7-13
    • /
    • 2008
  • The tillage depth control system is one of the most salient control system of tractor implements. A contact-type height sensor was developed to measure ground clearance for the tillage depth control. The height sensor was fabricated in this study, and its efficacy in a tillage depth control system was evaluated. Experiments were conducted in order to determine both static and dynamic detection characteristics of the height sensor using soil bin system on the sampled soil (sandy loam, sand, clay loam). The results of the static detection characteristics showed that in the case, sandy loam soil despite and clay loam soil at a wet basis moisture content of 30%, large measurement errors were observed a due to penetration of a plastic puck into the sampled soil. The results of the dynamic detection characteristics showed that the height sensor detected the distance from the ground of sandy loam soil despite the uneven nature of the ground surface and the changes in traveling speed $1km/h{\sim}5km/h$ at a wet basis moisture content of 10%.

New Diagnostic Technique and Device for Lightning Arresters by Analyzing the Wave Height Distribution of Leakage Currents (누설전류의 파고분포 분석에 의한 새로운 피뢰기 진단기술 및 장치)

  • 길경석;한주섭;송재영;조한구;한문섭
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.52 no.12
    • /
    • pp.562-567
    • /
    • 2003
  • Lightning arresters are deteriorated by repetition of protective operation against overvoltages or impulse currents in environments of its use. If a deteriorated arrester is left in power lines, it can lead to an accident such as a line to ground fault even in a normal system. Therefore, it is necessary to eliminate the deteriorated arrester in advance by checking the soundness of arresters on a regular basis, and to ensure the reliability of power systems by preventing accidents. Various deterioration diagnostic techniques and devices are suggested, and most of which measure leakage current components as an indicator of arrester ageing. However, the techniques based on the magnitude of leakage current measure simply RMS or peak value of leakage current components and do not provide detailed information needed in the diagnosis. In this study, we found that the wave height distributions of the total leakage currents are remarkably changed or a new wave height are produced with the progress of arrester deterioration. To propose a new technique for the diagnosis, we designed a leakage current detection unit and an analysis program which can measure leakage current magnitudes and analyze wave height distributions. From the experimental results, we confirmed that the proposed technique by analyzing the wave height distribution can simply diagnose the mode of defects such as a partial damage and an existence of punctures in arresters as well as deterioration of arresters.

Changes in the Health Life of the Elderly Through the Handle Height of Walking Assistant Vehicle Article : Emphasizing on State Anxiety, Heart Rate and Fall Efficacy (보행보조차 손잡이 높이에 따른 노인들의 건강생활의 변화 : 상태불안과 심박수, 낙상효능감을 중심으로)

  • Son, Sung-Min;Kwag, Sung-Won
    • Journal of Korea Entertainment Industry Association
    • /
    • v.14 no.7
    • /
    • pp.519-528
    • /
    • 2020
  • Purpose of this study is to analyze the changes in state anxiety, heart rate, and fall efficacy of the elderly through the handle height of walking assistant vehicle (WAV). The subjects were 32 elderlies. WAV was in the form of strollers, and it's handle height was set as 48% of a subject's total height. Also, it's height was divided into 48, 43, 38%. To measure the state anxiety, Korean State-Trait Anxiety Inventory was used and to measure the heart rate, Fitbit Charge 2 wrist heart rate monitor was used. To measure the fall efficacy, Fall Efficacy Scale-Korea was used. As the results of state anxiety and heart rate, the statistically significant increase showed continuously through the decrease of the handle height of WAV. As the results of fall efficacy, the statistically significant decrease showed continuously through the decrease of the handle height of WAV. In all of the post hoc test, the results of the state anxiety and fall efficacy showed significant difference among the each handle height of WAV and the results of the heart rate showed significant difference between the 48, 43% and 38% handle height of WAV. Thus, to decrease the state anxiety and heart rate and increase the fall efficacy of the elderly, the handle height of WAV should be properly positioned and considered to adjust to 48% of the user's total height.

The correlation among the oral & facial states and the gummy smile in female college students (일부 여대생의 구강 및 안모상태와 치은노출(Gummy smile)과의 상관성)

  • So, Mi-Hyun
    • Journal of Korean society of Dental Hygiene
    • /
    • v.12 no.2
    • /
    • pp.345-353
    • /
    • 2012
  • Objectives : The author has studied about correlation of gingival exposure upon smiling and oral facial status that reduce facial aesthetic. Methods : The subjects in this study are 91 female vulunteers who were in aged $21.4{\pm}1.89$ in Suwon. Objectives should be normal oral and facial status without the prosthodontic, orthodontic appliance or conqenital missing tooth, and agree to be examined the oral status and impression taking. 1.Measure the length of gingival exposure upon smiling. 2.Measure of the size on central incisor. 3.Measure of Facial. SPSS(SPSS 10.0 for windows, SPSS Inc, Chicago, USA) was utilized for calculating the correlation coefficient between gingival exposure upon smiling and facial status. Regression analysis was calculated in order to predict the R square for gingival exposure upon smiling. Results : 1.Correlation coefficient between the gingival exposure and length of maxillary central incisor was calculated as reversed correlation(r=-.302, p<0.01), and between the gingival exposure and the ratio of the length of central incisor/width of central incisor was revealed as reversed correlation(r=-.250, p<0.05) on smiling. 2.There was correlation between the gingival exposure and the facial height(r=.351, p<0.01), the lower facial height(r=.454, p<0.01) and the upper lip height(r=.274, p<0.01) upon smiling. 3.There was correlation between the gingival exposure and the ratio of the facial height/facial width(r=.358, p<0.05), the ratio of the upper facial height/facial width(r=.214, p<0.05), and the ratio of the lower facial height/facial height(r=.383, p<0.01) upon smiling. 4.The equation of the regression analysis for gingival exposure upon smiling could be estimated as gingival exposure upon smiling=-5.139+.279${\times}$lower facial height-.615${\times}$maxillary central incisal length-.05${\times}$nasolabial angle. Conclusions : Considering these results, it recommended that treatment planning should be designed in consideration of such factors as the length of maxillary central incisor, facial height, upper lip height and lower facial height, in order to promote the easthetic problems of face on smiling.

Flow Analysis and Flight Experiment for Optimum Height of Weather Data Sensor (기상데이터 센서의 최적 높이를 위한 유동해석 및 비행실험)

  • Kim, Young-in;Ku, SungKwan;Park, ChangHwan
    • Journal of Advanced Navigation Technology
    • /
    • v.22 no.6
    • /
    • pp.551-556
    • /
    • 2018
  • In recent years, drones have been used to measure aircraft flights data and weather information. Related applications include the measure for low-altitude atmospheric data, the measure for atmospheric fine dust, and the measure for air pollution. However, the mounting position of the atmospheric measurement sensor should be mounted by considering the effects of propeller flow, the EMI effects, and the changes in the weight of the drone. Among these, the upper flow of the propeller affects the wind speed and direction, so the optimal position should be selected. This study deals with the proper height of the atmospheric data measurement sensor. Through the flow analysis, we study the flow characteristics of around a drone and suggest the proper sensor mounting height.