Evaluation of Ventilation Performances for Various Combinations of Inlets and Outlets in a Residential Unit through CO2 Tracer-Gas Concentration Decay Method (CO2 추적가스 농도감소법을 이용한 공동주택의 급·배기구 조합에 따른 환기 성능 분석)

  • Sang Yoon Lee;Soo Man Lee;Jong Yeob Kim;Gil Tae Kim;Byung Chang Kwag
    • Land and Housing Review
    • /
    • v.14 no.4
    • /
    • pp.111-120
    • /
    • 2023
  • Indoor air quality has become increasingly important with the increase in time spent in residential environments, impact of external fine dust, yellow dust, and the post-COVID 19 pandemic. Residential mechanical ventilation plays a key role in addressing indoor air quality. The legal standard for residential air changes per hour in Korea is 0.5 ACH. However, there are no standards for the location of supply and return vents. This study atempts to analyze the impact of ventilation performance based on the location of supply and return vents. An experiment was conducted using the CO2 tracer gas concentration decay method in a mock-up house set inside a large chamber to minimize external influences. The experimental results indicated that the commonly used combination of 2 supply and 2 return vents in living room spaces had a lower mean age of air than the combination of 1 supply and 2 return vents. Using multiple supply and return vents had lower mean age of air than using just 1 supply and 1 return vent.

Research on Indoor Thermal Environment and Residents' Control Behavior of Cooling according to Household Type in Apartment (가구 유형에 따른 여름철 공동주택의 실내온열환경과 냉방 조절 행위에 관한 연구)

  • Bae, Chi-Hye;Bae, Nu-Ri;Chun, Chung-Yoon
    • Journal of the Korean housing association
    • /
    • v.19 no.1
    • /
    • pp.89-96
    • /
    • 2008
  • This study measured the thermal environment and residents' control behaviors of cooing according to 3 groups of household type-families with preschool children, families of middle age and families of senior. The object of this study are to fmd the difference of the actual condition of indoor thermal environment and cooling control behavior by age or household type and to develop user oriented climate control system. The results were summarized as follows. When the age of members at household is younger, the indoor mean temperature and temperature that people turned off the air conditioner became lower. These different indoor thermal environment of each group means that younger generation is familiar with cooler from their early age and these early uses of cooler made them prefer cooler condition than family of senior. Therefore, this results show that different indoor thermal environment is influenced by factors such as household type and metabolism difference and so on.

A Study on Estimation of Ventilation Performance in the Underground Parking Lot (지하 주차장의 환기성능평가에 관한 연구)

  • Hwang, Min-Kyu;Kim, Seong-Sik;Kim, Kang-Soo
    • Journal of the Korean Solar Energy Society
    • /
    • v.27 no.3
    • /
    • pp.71-77
    • /
    • 2007
  • In past, parking lot was placed on the ground and for the reason air quality was not in problem. But recently parking lot has been placed under the ground and the air quality becomes problem. So in this study, the ventilation performance on the underground parking lot was estimated by using CFD software and alternative system was suggested. Three case studies are handled in this study. 1st case is just an underground parking lot. 2nd case is about an underground parking lot where has 4 fan rooms on each floor and 3rd case is about an underground parking lot where has 4 fan rooms and 30 guidance fans on each floor.

A Study on Acute Effects of Ambient Air Particles on Pulmonary Function of Schoolchildren in Ulsan

  • Yu, Seung-Do;Kim, Dae-Seon;Cha, Jung-Hoon;Ahn, Seung-Chul;Lee, Jong-Tae
    • Proceedings of the Korean Environmental Health Society Conference
    • /
    • 2003.06a
    • /
    • pp.183-186
    • /
    • 2003
  • To evaluate the effect of air pollution on respiratory health in children, we conducted a longitudinal study in which children were asked to record their daily levels of peak expiratory flow rate using potable peak flow meter (mini-Wright) far 4 weeks. The relationship between daily PEFR and ambient air particle levels was analyzed using a mixed linear regression models including gender, age in you, weight, the presence of respiratory symptoms, and relative humidity as an extraneous variable. The daily mean concentrations of PM$\_$10/ and PM$\_$2.5/ over the study period were 64.9$\mu\textrm{g}$/㎥ and 46. l$\mu\textrm{g}$/㎥, respectively. The range of daily measured PEFR in this study was 170-481 l/min. Daily mean PEFR was regressed with the 24-hour. average PM$\_$10/ (or PM$\_$2.5/) levels, weather information such as air temperature and relative humidity, and individual characteristics including sex, weight, and respiratory symptoms. The analysis showed that the increase of air particle concentrations was negatively associated with the variability in PEFR. We estimated that the IQR increment of PM$\_$10/ or PM$\_$2.5/ were associated with 1.5 l/min (95% Confidence intervals -3.1, 0.1) and 0.8 l/min (95% Cl -1.8, 0.1) decline in PEFR. Even though this study shows negative findings on the relationship between respiratory function and air particles, it is worth noting that the findings must be interpreted cautiously because exposure measurement based on monitoring of ambient air likely results in misclassification of true exposure levels and this is the first Korean study that PM$\_$2.5/ measurement is applied as an index of air particle quality.

  • PDF

Evaluation of the Ventilation Efficiency in an Underground Sewage Disposal Plant (지하 수처리시설 유지관리층 환기설비의 성능평가)

  • Kang, Han-Gi;Lee, Jae-Heon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.10
    • /
    • pp.695-702
    • /
    • 2007
  • In this paper, the ventilation efficiencies of an underground sewage disposal plant were investigated for ventilating system without fan, ventilating system with eleven cross flow fans and ventilating system with sixteen cross flow fans by numerical method. It has been found that the air change effectiveness of the system without fan was predicted 0.44. It means that an additional ventilating equipment is needed to maintain good indoor air quality. For the ventilating system with sixteen cross flow fans, the air change effectiveness was predicted 0.55. The air change effectiveness of the ventilating system with eleven cross flow fans was predicted 0.51. It is known that the air change effectiveness above 0.5 is enough to eliminate pollutant and bad smell in the indoor. Therefore, it is recommended to select the ventilating system with eleven cross flow fans for the underground sewage disposal plant in an economic point of view.

Exposure of Organic Solvent Mixtures and Subjective Symptoms to Beauty-Salon Workers (미용실(Beauty salon) 근로자들의 유기용제 폭로와 자각증상에 관한 연구)

  • Lee, Chang-Eun;Sim, Sang-Hyo
    • Journal of Environmental Science International
    • /
    • v.18 no.3
    • /
    • pp.345-353
    • /
    • 2009
  • The purpose of this study is to examine the health of beauty salon workers through the utilization of questionnaires concerning the extent of exposure to organic solvents found in the air of some beauty salons and any resultant symptoms in employees. The subjects were 36 employees from 10 beauty salons who agreed to participate in this study. The degree of exposure to organic solvents in the air of beauty salons was measured from September 1, 2008 to September 30, 2008. A survey of symptoms that occurred due to exposure to these solvents was also performed. The results were as follows: questionnaires were collected and analyzed from a total of 36 subjects. Of these, 28(77.8%) were female and 8(22.2%) were male. The mean age was 29.08. The mean working period was 7.13 years. Sixteen subjects attended programs at universities while 11 went to beauty schools for vocational education. When testing the concentration of organic solvents in the air of beauty salons, the highest value found was Isopropyl alcohol 511.85 ppb followed by butyl acetate, toluene, acetone, xylene, ethyl benzene, styrene, and chlorobenzene. A logistic regression analysis was performed as follows: the point of each factor was the dependent variable while sex, age, drinking, smoking, educational level, work experience, hairdresser's license, and organic solvents were the independent variables. Statistically significant difference (p<0.05) was shown in the hairdresser's license among Factor 1 and in Xylene among Factor 2; however, difference was not shown in the other variables.

Mean Value of Aerodynamic Study in Normal Korean (음성검사 중 공기역학적 검사에서 한국인의 정상 평균치)

  • 서장수;송시연;권오철;김준우;이희경;정옥란
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.8 no.1
    • /
    • pp.27-32
    • /
    • 1997
  • Recently, many people suffering from voice color change visit otolaryngologist. There is no specific data which can be evaluated objectively for voice color change in korean. In aerodynamic study, maximum phonation time, mean air flow rate, phonatory flow volume and subglottal pressure were tested by using Aerophone II voice function analyzer in korean. 112 male and 122 female aged from 10 to 69 years were randomly selected. Maximum phonation time was 20.8${\pm}$6.4sec in male and 17.2${\pm}$4.1sec in female. Mean air flow rate was 167.1${\pm}$61.4ml/sec. in male and 129.6${\pm}$49.3ml/sec in female. Phonatory flow volume was 3184.5${\pm}$646.0ml in male and 2122.1${\pm}$670.5ml in female. Subglottal pressure was 4.1${\pm}$1.8 cmH2O in male and 3.5${\pm}$1.4cm $H_2O$ in female. There was no statistically significant difference among age groups in all above results.

  • PDF

Respiratory Syncytial Virus Outbreak in the Basic Military Training Camp of the Republic of Korea Air Force

  • Park, Won-Ju;Yoo, Seok-Ju;Lee, Suk-Ho;Chung, Jae-Woo;Jang, Keun-Ho;Moon, Jai-Dong
    • Journal of Preventive Medicine and Public Health
    • /
    • v.48 no.1
    • /
    • pp.10-17
    • /
    • 2015
  • Objectives: An outbreak of acute febrile illness occurred in the Republic of Korea Air Force boot camp from May to July 2011. An epidemiological investigation of the causative agent, which was of a highly infective nature, was conducted. Methods: Throat swabs were carried out and a multiplex reverse transcriptase-polymerase chain reaction (RT-PCR) assay was performed to identify possible causative factors. Results: The mean age of patients who had febrile illness during the study period was 20.24 years. The multiplex RT-PCR assay identified respiratory syncytial virus (RSV) as the causative agent. The main symptoms were sore throat (76.0%), sputum (72.8%), cough (72.1%), tonsillar hypertrophy (67.9%), and rhinorrhea (55.9%). The mean temperature was $38.75^{\circ}C$ and the attack rate among the recruits was 15.7% (588 out of 3750 recruits), while the mean duration of fever was 2.3 days. The prognosis was generally favorable with supportive care but recurrent fever occurred in 10.1% of the patients within a month. Conclusions: This is the first epidemiological study of an RSV outbreak that developed in a healthy young adult group. In the event of an outbreak of an acute febrile illness of a highly infective nature in facilities used by a young adult group, RSV should be considered among the possible causative agents.

A Study of Working Environment for Automotive Painting in Auto Repair Shops and Workers' Exposure to Hazardous Chemicals (자동차 정비업체 도장공정의 작업환경 및 근로자 노출 실태에 관한 연구)

  • Sim, Sang-Hyo;Jeoung, Chun-Hwa;Lim, Jin-Suk;Lee, Hyung-Gu;Kim, Yoon-Shin
    • Journal of Environmental Health Sciences
    • /
    • v.35 no.3
    • /
    • pp.153-161
    • /
    • 2009
  • The purpose of this paper is to evaluate 1) blood lead levels of workers at auto repair shops as Biological Exposure Indices (BEI) of toxic substances such as lead and toluene that are produced during automotive painting process, 2) the differences depending on personal characteristics of workers who have been exposed to toluene by using urine hippuric acid concentration as a marker and 3) the correlation between the concentration of hazardous chemicals in each workplace and the BEL. All subjects were male with a mean age of 36.2 years. In terms of age, most were in the 30 to 40 age group (13 persons, 48.1%). In relation to the length of work experience, the highest proportion had experience of 10 years of less (18 persons, 66.7%). Twenty three workers were cigarette smokers (85.2%) while 4 (14.8%) were non-smokers. In addition, more than 80% of the workers drank alcohol. Dust concentration and toluene exposure during automotive painting showed no significant difference with age, length of work experience, smoking and drinking while a significant difference (p<0.05) has been detected between lead concentration and smoking. The geometric mean of dust concentration, lead concentration and toluene concentration were $0.38mg/m^3,\;0.0021mg/m^3$ and 1.08ppm respectively. In addition, the geometric mean of blood lead levels and urine hippuric acid concentration were $1.70{\mu}g/dl$ and 0.25g/g respectively, which were lower than the standard levels suggested by the Ministry of Labor. To determine the influential factors on blood lead and urine hippuric acid concentrations, a correlation analysis has been conducted with variables of air, lead and toluene concentrations, age, length of work experience and amount of cigarette smoking. According to the analysis, a relatively high correlation (p<0.01) has been observed between air lead concentration and biological sample concentration.

A Study on Ventilation Effectiveness in the Non-isothermal Supply using Mixing and Displacement Ventilation Systems (비등온 급기조건에서 환기방식에 따른 환기효율 특성에 관한 연구)

  • 이재근;강태욱;윤석구;구재현;한정균;조민철
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.8
    • /
    • pp.739-745
    • /
    • 2001
  • The objective of this research is to analyze the ventilation effectiveness in the non-isothermal air supply using mixing and displacement ventilation systems for indoor air quality control and management. In this study, a ventilation effectiveness is evaluated in a simplified model chamber using a tracer gas technique of $CO^2$ gas injected into a supply duct as a function of ventilation rates, supply/extract sites and cooling/heating air supply. The ventilation effectiveness decreased with increasing ventilation rate on the cooling and heating conditions. And the ventilation effectiveness of case 3 (down supply and upper extract) was better thant that of case 1(upper supply and upper extract) and case 2(upper supply and down extract) with the cooling supply conditions. but for the heating supply air conditions, the ventilation effectiveness of case 2 was better than that of case 3 and case 1.

  • PDF