• Title/Summary/Keyword: Mean Absolute Difference

Search Result 203, Processing Time 0.025 seconds

Developmental Difference in Metacognitive Accuracy between High School Students and College Students (메타인지 정확성의 발달 차이 연구: 고등학생과 대학생 데이터)

  • Bae, Jinhee;Cho, Hye-Seung;Kim, Kyungil
    • Korean Journal of Cognitive Science
    • /
    • v.26 no.1
    • /
    • pp.53-67
    • /
    • 2015
  • Metacognitive monitoring refers to high dimensional cognitive activities. Understanding one's own cognitive processes accurately can make effective controls for their performance. Brain area related with metacognition is PFC which is completed the order of late and it can be inferred that monitoring abilities is developing during late adolescent. In this study, we explored the developmental difference in monitoring accuracy between high school students and college students using by measuring JOL(Judgment of Learning). Participants was asked that they study Spanish-Korean word pairs and judge their future performance of memory. In the result, people in both groups thought that they could remember word pairs better than their actual performance. Absolute bias scores which mean the degree to predict their performance apart from true scores showed the interaction between subject groups and task difficulty. Specifically, people judged their learning state quite accurately in easy task condition. However, in difficult task condition, both groups showed inaccuracy for predicting their learning and the magnitude of the degree was bigger in the group of high school students.

Marginal and Internal Fit of Copings Made by CAD/CAM using Different Scanning Methods (서로 다른 스캔 방식을 이용하여 CAD/CAM에 의해 제작된 코핑의 변연 및 내면의 적합성)

  • Cho, Young Beom;Chae, Heon Chung;Kim, Hee Jung
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.29 no.4
    • /
    • pp.366-376
    • /
    • 2013
  • The purpose of this study is to evaluate the marginal and internal fit of coping made by CAD/CAM using different scanning methods. Zirconia coping was made by each CAD/CAM system followed by intra-oral scanning, model optical scanning and model contact scanning. It was embedded into Epoxy Resin and was cut by buccal to lingual. AMD (Absolute marginal discrepancy), MG (Marginal gap), GA (Gap of axial), GL (Gap of line angle) and GO (Gap of occlusal) of each sample were measured. The result is as followed; 1. The mean value of AMD in Group 1, Group 2, Group 3 are $141.21{\pm}42.94{\mu}m$, $140.63{\pm}31.64{\mu}m$, $109.37{\pm}28.42{\mu}m$. The averages of MG in Group 1, Group 2, Group 3 are $82.52{\pm}43.99{\mu}m$, $90.28{\pm}27.93{\mu}m$, $66.55{\pm}28.77{\mu}m$. Statistically there is no difference in AMD and MG among the three Groups (Anova, P>0.05). 2. GA of Group 2 revealed statistically difference compared with Group 1 and Group 3 (Anova, P<0.05). 3. GL and GO of Group 1 showed statistically significant differences compared with Group 2 and Group 3 (Mann-whitney test (P<0.05). Zirconia copings made by 3 ways of scanning methods have no difference with conventional ceramics in AMD and MG which are known as the most important factors.

Comparison between Gel Pad Cooling Device and Water Blanket during Target Temperature Management in Cardiac Arrest Patients

  • Jung, Yoon Sun;Kim, Kyung Su;Suh, Gil Joon;Cho, Jun-Hwi
    • Acute and Critical Care
    • /
    • v.33 no.4
    • /
    • pp.246-251
    • /
    • 2018
  • Background: Target temperature management (TTM) improves neurological outcomes for comatose survivors of out-of-hospital cardiac arrest. We compared the efficacy and safety of a gel pad cooling device (GP) and a water blanket (WB) during TTM. Methods: We performed a retrospective analysis in a single hospital, wherein we measured the time to target temperature ($<34^{\circ}C$) after initiation of cooling to evaluate the effectiveness of the cooling method. The temperature farthest from $33^{\circ}C$ was selected every hour during maintenance. Generalized estimation equation analysis was used to compare the absolute temperature differences from $33^{\circ}C$ during the maintenance period. If the selected temperature was not between $32^{\circ}C$ and $34^{\circ}C$, the hour was considered a deviation from the target. We compared the deviation rates during hypothermia maintenance to evaluate the safety of the different methods. Results: A GP was used for 23 patients among of 53 patients, and a WB was used for the remaining. There was no difference in baseline temperature at the start of cooling between the two patient groups (GP, $35.7^{\circ}C$ vs. WB, $35.6^{\circ}C$; P=0.741). The time to target temperature (134.2 minutes vs. 233.4 minutes, P=0.056) was shorter in the GP patient group. Deviation from maintenance temperature (2.0% vs. 23.7%, P<0.001) occurred significantly more frequently in the WB group. The mean absolute temperature difference from $33^{\circ}C$ during the maintenance period was $0.19^{\circ}C$ (95% confidence interval [CI], $0.17^{\circ}C$ to $0.21^{\circ}C$) in the GP group and $0.76^{\circ}C$ (95% CI, $0.71^{\circ}C$ to $0.80^{\circ}C$) in the WB group. GP significantly decreased this difference by $0.59^{\circ}C$ (95% CI, $0.44^{\circ}C$ to $0.75^{\circ}C$; P<0.001). Conclusions: The GP was superior to the WB for strict temperature control during TTM.

RELATIONSHIPS BETWEEN MANDIBULAR LATERAL DEVIATION AND MORPHOLOGY OF THE CRANIAL VAULIT (안면비대칭 환자에서 하악의 측방변위와 두개관형태 사이의 연관성)

  • Shin, Shang-Wook;Jang, Hyun-Jung;Lee, Sang-Han
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.18 no.4
    • /
    • pp.594-606
    • /
    • 1996
  • This study was intended to perform the relationships between mandibualr lateral deviation in facial asymmetry patients and morphology of the cranial vault. In 30 patients(males 14, female 16) using submento-vertical cephalograms that were taken in the pre-operaticve state and posteroanterioir cephalograms that were taken in centric occlusion before, immediate and long term after surgery. 1. Mean mandibular deviation was about $-3.12^{\circ}$and mean of absolute measurement was about $2.50^{\circ}$on the submento-vertical cephalograms. 2. On the submento-vertical cephalograms, there was no significant difference between non-deviation and deviation side but it had tendency that deviation side was larger than non-deviation side on the frontal portion of cranium(Y10 to Y6) and deviation side was smaller than non-deviation on the temporal portion of cranium(Y5, Y-1 to Y-5). 3. Mean mandibular deviation was about $1.40^{\circ}$and mean of absolute measurement was about $3.95^{\circ}$on the posteroanterioir cephalograms. 4. There was statistical significance on the influence of surgical change(PT2A-PT1A) to the relapse(PTLA-PT2A)(p<0.05). The more increasing of the change, the more relapse on the posteroanterioir cephalograms. 5. There was no statistical significance on the influence of degree of mandibular deviation to morphology of the cranium on the submento-vertical cephalograms. But it had tendency that the more mandibular deviation, the larger the non-deviation side on the anterior cranium and deviation side on the posterior cranium(p>0.05). 6. There was statistical significance on the influence of the degree of mandibular deviation on the posteroanterioir cephalograms to the difference between non-deviation and deviation side. The more increasing of mandibular deviation, the larger the non-deviation side on the Y4 to Y-6(p<0.05). 7. There was no statistical significance on the influence of difference between non-deviation and deviation side to the relapse on the posteroanterioir cephalograms. But it had tendency that the more increasing of the differece between non-deviation and deviation side, the more increasing the relapse on temporal of cranium.

  • PDF

Radiographic assessment of clinical root-crown ratios of permanent teeth in a healthy Korean population

  • Yun, Hee-Jung;Jeong, Jin-Sun;Pang, Nan-Sim;Kwon, Il-Keun;Jung, Bock-Young
    • The Journal of Advanced Prosthodontics
    • /
    • v.6 no.3
    • /
    • pp.171-176
    • /
    • 2014
  • PURPOSE. The aim of this study was to determine the absolute value of the root/crown ratio (R/C ratio) using panoramic radiographs (PRGs) in a healthy Korean population. MATERIALS AND METHODS. In total, 99 patient radiographs (of 50 males and 49 females subjects; aged 16 to 24 years old) were examined, and 2,770 teeth were analyzed. Crown lengths and root lengths were measured with modified Lind's measurements using PACS tools by two examiners in two separate sessions two months apart. All data were analyzed using SPSS. The independent t-test was used to assess for gender differences, and the paired t-test was used to compare both arches with a significance level of P<.05. RESULTS. The mean R/C ratios varied from 1.29 to 1.89 (male: 1.28-1.84; females: 1.31-1.94). The highest R/C ratios were recorded for the mandibular canines (1.89), followed by the maxillary canines (1.79). The lowest R/C ratios were recorded for the maxillary second molars (1.31). In comparison with the maxillary teeth (1.29-1.78), the mandibular teeth yielded the higher R/C ratio (1.47-1.89), and this difference was significant in the females (P<.05). The difference between the genders was not statistically significant, except for the maxillary central incisors, mandibular canines and mandibular first premolars. CONCLUSION. These data may enhance the understanding of the clinical R/C ratio as a useful guideline for determining the status of teeth and the ethnic difference.

Fast Full Search Block Matching Algorithm Using The Search Region Subsampling and The Difference of Adjacent Pixels (탐색 영역 부표본화 및 이웃 화소간의 차를 이용한 고속 전역 탐색 블록 정합 알고리듬)

  • Cheong, Won-Sik;Lee, Bub-Ki;Lee, Kyeong-Hwan;Choi, Jung-Hyun;Kim, Kyeong-Kyu;Kim, Duk-Gyoo;Lee, Kuhn-Il
    • Journal of the Korean Institute of Telematics and Electronics S
    • /
    • v.36S no.11
    • /
    • pp.102-111
    • /
    • 1999
  • In this paper, we propose a fast full search block matching algorithm using the search region subsampling and the difference of adjacent pixels in current block. In the proposed algorithm, we calculate the lower bound of mean absolute difference (MAD) at each search point using the MAD value of neighbor search point and the difference of adjacent pixels in current block. After that, we perform block matching process only at the search points that need block matching process using the lower bound of MAD at each search point. To calculate the lower bound of MAD at each search point, we need the MAD value of neighbor search point. Therefore, the search points are subsampled at the factor of 4 and the MAD value at the subsampled search points are calculated by the block matching process. And then, the lower bound of MAD at the rest search points are calculated using the MAD value of the neighbor subsampled search point and the difference of adjacent pixels in current block. Finally, we discard the search points that have the lower bound of MAD value exceed the reference MAD which is the minimum MAD value of the MAD values at the subsampled search points and we perform the block matching process only at the search points that need block matching process. By doing so, we can reduce the computation complexity drastically while the motion compensated error performance is kept the same as that of full search block matching algorithm (FSBMA). The experimental results show that the proposed method has a much lower computational complexity than that of FSBMA while the motion compensated error performance of the proposed method is kept same as that of FSBMA.

  • PDF

A Gaussian Mixture Model Based Surface Electromyogram Pattern Classification Algorithm for Estimation of Wrist Motions (손목 움직임 추정을 위한 Gaussian Mixture Model 기반 표면 근전도 패턴 분류 알고리즘)

  • Jeong, Eui-Chul;Yu, Song-Hyun;Lee, Sang-Min;Song, Young-Rok
    • Journal of Biomedical Engineering Research
    • /
    • v.33 no.2
    • /
    • pp.65-71
    • /
    • 2012
  • In this paper, the Gaussian Mixture Model(GMM) which is very robust modeling for pattern classification is proposed to classify wrist motions using surface electromyograms(EMG). EMG is widely used to recognize wrist motions such as up, down, left, right, rest, and is obtained from two electrodes placed on the flexor carpi ulnaris and extensor carpi ulnaris of 15 subjects under no strain condition during wrist motions. Also, EMG-based feature is derived from extracted EMG signals in time domain for fast processing. The estimated features based in difference absolute mean value(DAMV) are used for motion classification through GMM. The performance of our approach is evaluated by recognition rates and it is found that the proposed GMM-based method yields better results than conventional schemes including k-Nearest Neighbor(k-NN), Quadratic Discriminant Analysis(QDA) and Linear Discriminant Analysis(LDA).

Aerosol Direct Radiative Forcing by Three Dimensional Observations from Passive- and Active- Satellite Sensors (수동형-능동형 위성센서 관측자료를 이용한 대기 에어러솔의 3차원 분포 및 복사강제 효과 산정)

  • Lee, Kwon-Ho
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.28 no.2
    • /
    • pp.159-171
    • /
    • 2012
  • Aerosol direct radiative forcing (ADRF) retrieval method was developed by combining data from passive and active satellite sensors. Aerosol optical thickness (AOT) retrieved form the Moderate Resolution Imaging Spectroradiometer (MODIS) as a passive visible sensor and aerosol vertical profile from to the Cloud-Aerosol Lidar and Infrared Pathfinder Satellite Observations (CALIPSO) as an active laser sensor were investigated an application possibility. Especially, space-born Light Detection and Ranging (Lidar) observation provides a specific knowledge of the optical properties of atmospheric aerosols with spatial, temporal, vertical, and spectral resolutions. On the basis of extensive radiative transfer modeling, it is demonstrated that the use of the aerosol vertical profiles is sensitive to the estimation of ADRF. Throughout the investigation of relationship between aerosol height and ADRF, mean change rates of ADRF per increasing of 1 km aerosol height are smaller at surface than top-of-atmosphere (TOA). As a case study, satellite data for the Asian dust day of March 31, 2007 were used to estimate ADRF. Resulting ADRF values were compared with those retrieved independently from MODIS only data. The absolute difference values are 1.27% at surface level and 4.73% at top of atmosphere (TOA).

The Effect of Data Sparsity on Prediction Accuracy in Recommender System (추천시스템의 희소성이 예측 정확도에 미치는 영향에 관한 연구)

  • Kim, Sun-Ok;Lee, Seok-Jun
    • Journal of Internet Computing and Services
    • /
    • v.8 no.6
    • /
    • pp.95-102
    • /
    • 2007
  • Recommender System based on the Collaborative Filtering has a problem of trust of the prediction accuracy because of its problem of sparsity. If the sparsity of a preference value is large, it causes a problem on a process of a choice of neighbors and also lowers the prediction accuracy. In this article, a change of MAE based on the sparsity is studied, groups are classified by sparsity and then, the significant difference among MAEs of classified groups is analyzed. To improve the accuracy of prediction among groups by the problem of sparsity, We studied the improvement of an accurate prediction for recommending system through reducing sparsity by sorting sparsity items, and replacing the average preference among them that has a lot of respondents with the preference evaluation value.

  • PDF

An Experimental Study of Partial Admitted Flow Characteristics on a Small Axial-Type Turbine (소형축류형 터빈에서의 부분분사 유동특성에 관한 연구)

  • Cho, Chong-Hyun;Cho, Soo-Yong;Choi, Sang-Kyu
    • The KSFM Journal of Fluid Machinery
    • /
    • v.7 no.6 s.27
    • /
    • pp.28-37
    • /
    • 2004
  • An experimental study is conducted to investigate flow characteristics on a small axial-type turbine which is applied as the rotating part of air tools. It operates in a partial admission due to consumption restriction of the high pressure air. In this operating condition, it is necessary to understand flow characteristics for obtaining the high specific output power. Tested turbine consists of two stages and the mean radius of flow passage is less than 10mm. A 6 bar pressure air is used to operate the turbine. The experimental results show that flow angles depend on the measuring location along the circumferential direction, but its discrepancy is alleviated along the axial direction. Absolute flow velocities show three times difference according to the measuring location at the exit of the first rotor due to the partial admission, but they show similar value at the exit of the second rotor by the velocity diffusion. From the measured flow angles and velocities, a ratio of output power obtained by the first and second rotor is estimated. It shows that the output power obtained by the second rotor is about $11\%$ to that by the first rotor at 60,000 RPM. It is effective therefore to improve the first rotor for increasing the turbine output power.