• 제목/요약/키워드: MeV electron beam

검색결과 195건 처리시간 0.021초

흉곽(胸廓)의 전자선(電子線) 조사시(照射時) 선량분포(線量分布)에 관(關)한 연구(硏究) (A Study on Electron Beam Dosimetry for Chest Wall Irradiation)

  • 강위생;고경환;하성환;박찬일
    • Radiation Oncology Journal
    • /
    • 제1권1호
    • /
    • pp.41-45
    • /
    • 1983
  • To obtain 7 MeV electron beam which is suitable for treatment of the chest wall after radical of modified radical mastectomy, the authors reduced the energy of electron beam by means by Lucite plate inserted in the beam. To determine the proper thickness of the Lucite plate necessary to reduce the energy of 9 MeV electron beam to 6 MeV, dosimetry was made by using a parallel plate ionization chamber in polystyrene phantom. Separation between two adjacent fields, 7 MeV for chest wall and 12 MeV for internal mammary region, was studied by means of film dosimetry in both polytyrene phantom and Humanoid phantom. The results were as follows. 1. The average energy of 9 MeV electron beam transmitted through the Lucite plate was reduced. Reduction was proportional to the thickness of the Lucite plate in the rate of 1.7 MeV/cm. 2. The proper thickness of the Lucite plate necessary to obtain 6 MeV electron beam from 9 MeV was 1.2 cm. 3. 7 MeV electron beam, 80% dose at 2cm depth, is adequate for treatment of the chest wall. 4. Proper separation between two adjacent electron fields, 7 MeV and 12 MeV, was 5mm on both flat surface and sloping surface to produce uniform dose distribution.

  • PDF

유방암에서 CT planning를 이용한 치료계획 (Radiotherapy Treatment Planning using Computed Tomography in Breast Cancer)

  • 김성규;신세원;김명세
    • 한국의학물리학회지:의학물리
    • /
    • 제3권2호
    • /
    • pp.59-65
    • /
    • 1992
  • 유방암은 여성암 가운데 세계에서 가장 빈도가 높으며, 한국에서도 세번째로 많은 것으로 보고하고 있다. 유방암에서 방사선치료는 photon beam를 이용하여 tangential field로 치료하거나 electron beam를 이용하여 치료하는 것이 보편적이다. 치료범위 내부의 밀도와 tumor까지의 깊이는 방사선치료에서 선량분포를 결정하는 중요한 요소들이다. CT planning를 이용하면 이러한 요소들을 정확하게 산출하여 선량과 선량분포를 결정하는데 이용할 수 있다. 저자들이 유방암 환자 65명중 전자선으로 치료를 받은 45명을 분석한 결과 cheast wall의 두께와 internal mammary lyphnode의 깊이가 1.5cm 이하인 경우에는 6MeV의 에너지가 적적함을 보여 주었으며, 1.5cm에서 2.0cm까지는 9MeV의 에너지가, 2.0cm에서 2.5cm까지는 12MeV의 에너지가 적절함을 보였다.

  • PDF

방사선 치료용 전자선의 에너지별 납(Pb) 차폐체 두께 측정 (A Study on the Lead(Pb) Shield Thickness per Electron Beam Energy in Radiotherapy)

  • 김가중
    • 한국방사선학회논문지
    • /
    • 제16권6호
    • /
    • pp.719-725
    • /
    • 2022
  • 본 연구는 임상에서 이용되는 전자선 빔의 에너지별 차폐를 위한 최소한의 납 두께를 측정하여 정량적으로 평가하고 기준을 설정하고자 한다. 전자선 에너지별 납 차폐체의 두께는 최대선량 깊이(dmax)와 조직선량의 기준 깊이인 표면 10 mm 깊이에서 개방 조사야를 기준으로 1차선속의 95%로 감소시킬 수 있는 납 두께를 측정하였다. 측정 결과 6 MeV 전자선의 납 차폐체 두께는 최대선량 깊이에서 1.906 mmPb, 조직선량 기준깊이(10 mm)에서 1.992 mmPb로 나타났으며, 9 MeV 전자선은 2.746 mmPb, 3.743 mmPb, 12 MeV 전자선은 3.718 mmPb, 6.093 mmPb, 16 MeV 전자선은 7.300 mmPb, 15.270 mmPb, 20 MeV 전자선은 16.825 mmPb, 25.090 mmPb로 측정 깊이를 조직선량 기준깊이로 할 때 더 두꺼운 납 차폐체가 필요하였다. 또한 16 MeV 이상의 전자선은 이론식보다 더 두꺼운 납 차폐체가 요구된다.

전자선 Quality Assurance 선량계 개발을 위한 TlBr 물질의 검출성능 평가 (Evaluation of Detection Performance of TlBr Materials for the Development of Electron Beam Quality Assurance Dosimeters)

  • 양승우;박성광
    • 한국방사선학회논문지
    • /
    • 제16권5호
    • /
    • pp.513-518
    • /
    • 2022
  • 전자선의 정도관리(quality assurance, QA)는 정확한 방사선 치료를 위해 정기적으로 이루어져야한다. 하지만 임상에서 사용되는 QA도구는 X선 위주로 설계되어 있어서 전자선 전용의 QA 선량계가 요구된다. 이에 본 연구에서는 방사선 검출 효율이 뛰어난 브롬화탐륨 물질을 전자선 센서로 활용하여 전자선 검출성능을 측정하고 전자선 전용의 QA 선량계로 적용가능할지를 평가하였다. 평가항목은 재현성, 선형성, 선량률 의존성이며, 선형가속기의 6 MeV, 9 MeV 에너지에서 평가하였다. 재현성 결과, 6 MeV에서는 최대 0.92%, 9 MeV에서는 최대 1.15%의 출력변화를 보여주었다. 선형성 결과평가, 결정계수 R2이 0.9998로 제시되었다. 선량률 의존성 평가 결과, 6 MeV에서는 상대표준편차 0.51%, 9 MeV에서는 상대표준편차 1.07%의 선량률 의존성이 제시되었다. 본 연구에서 제작한 TlBr 센서는 재현성, 선형성, 선량률 의존성의 모든 평가기준을 만족하는 검출성능을 보여준다. 이러한 결과들은 TlBr 선량계가 전자선 전용 QA 선량계로 적용 가능한 것을 의미한다.

Analysis of Dose Distribution According to the Initial Electron Beam of the Linear Accelerator: A Monte Carlo Study

  • Park, Hyojun;Choi, Hyun Joon;Kim, Jung-In;Min, Chul Hee
    • Journal of Radiation Protection and Research
    • /
    • 제43권1호
    • /
    • pp.10-19
    • /
    • 2018
  • Background: Monte Carlo (MC) simulation is the most accurate for calculating radiation dose distribution and determining patient dose. In MC simulations of the therapeutic accelerator, the characteristics of the initial electron must be precisely determined in order to achieve accurate simulations. However, It has been computation-, labor-, and time-intensive to predict the beam characteristics through predominantly empirical approach. The aim of this study was to analyze the relationships between electron beam parameters and dose distribution, with the goal of simplifying the MC commissioning process. Materials and Methods: The Varian Clinac 2300 IX machine was modeled with the Geant4 MC-toolkit. The percent depth dose (PDD) and lateral beam profiles were assessed according to initial electron beam parameters of mean energy, radial intensity distribution, and energy distribution. Results and Discussion: The PDD values increased on average by 4.36% when the mean energy increased from 5.6 MeV to 6.4 MeV. The PDD was also increased by 2.77% when the energy spread increased from 0 MeV to 1.019 MeV. In the lateral dose profile, increasing the beam radial width from 0 mm to 4 mm at the full width at half maximum resulted in a dose decrease of 8.42% on the average. The profile also decreased by 4.81% when the mean energy was increased from 5.6 MeV to 6.4 MeV. Of all tested parameters, electron mean energy had the greatest influence on dose distribution. The PDD and profile were calculated using parameters optimized and compared with the golden beam data. The maximum dose difference was assessed as less than 2%. Conclusion: The relationship between the initial electron and treatment beam quality investigated in this study can be used in Monte Carlo commissioning of medical linear accelerator model.

Characterization of the 2.5 MeV ELV electron accelerator electron source angular distribution using 3-D dose measurement and Monte Carlo simulations

  • Chang M. Kang;Seung-Tae Jung;Seong-Hwan Pyo;Youjung Seo;Won-Gu Kang;Jin-Kyu Kim;Young-Chang Nho;Jong-Seok Park;Jae-Hak Choi
    • Nuclear Engineering and Technology
    • /
    • 제55권12호
    • /
    • pp.4678-4684
    • /
    • 2023
  • Using the Monte Carlo method, the impact of the angular distribution of the electron source on the dose distribution for the 2.5 MeV ELV electron accelerator was explored. The experiment measured the 3-D dose distribution in the irradiation chamber for electron energies of 1.0 MeV and 2.5 MeV. The simulation used the MCNP6.2 code to evaluate three angular distribution models of the source: a mono-directional beam, a cone shape, and a triangular shape. Of the three models, the triangular shape with angles θ = 30°, φ = 0° best represents the angle of the scan hood through which the electron beam exits. The MCNP6.2 simulation results demonstrated that the triangular model is the most accurate representation of the angular distribution of the electron source for the 2.5 MeV ELV electron accelerator.

6 MeV 전자선의 물팬텀 속의 선량분포에 관한 모의계산 (The Simulation on Dose Distributions of the 6 MeV Electron Beam in Water Phantom)

  • 이정옥;정동혁;문성록
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제23권2호
    • /
    • pp.75-79
    • /
    • 2000
  • This study was performed for the clinical applications applying the Monte Carlo methods. In this study we calculated the absorbed dose distributions for the 6 MeV electron beam in water phantom and compared the results with measured values. The energy data of electron beam used in Monte Carlo calculation is the energy distribution for 6 MeV electron beam which is assumed as a Gaussian form. We calculated percent depth doses and beam profiles for three field sizes of $10{\times}10,\;15{\times}15$, and $20{\times}20\;cm^2$ in water phantom using Monte Carlo methods and measured those data using a semiconductor detector and other devices. We found that the calculated percent depth doses and beam profiles agree with the measured values approximately. However, the calculated beam profiles at the edge of the fields were estimated to be lower than the measured values. The reason for that result is that we did not consider the angular distributions of the electrons in phantom surface and contamination of X-rays in our calculations. In conclusion, in order to apply the Monte Carlo methods to the clinical calculations we are to study the source models for electron beam of the linear accelerator beforehand.

  • PDF

방사선치료 전자선의 정도관리를 위한 Lead Oxide 선량계 평가 (Evaluation of Lead Oxide Dosimeter for Quality Assurance of Electron Beam in Radiotherapy)

  • 양승우;한무재;박성광
    • 한국방사선학회논문지
    • /
    • 제15권1호
    • /
    • pp.79-83
    • /
    • 2021
  • 방사선 치료 영역에서 전자선은 표재성 병변 치료에 자주 쓰인다. 전자선은 빔 경로에 것들과 상호 작용하여 선량측정에 영향을 끼치기에 정확한 측정이 요구된다. 하지만 전자선 정도관리에 관한 연구는 이루어지고 있지 않는 실정이다. 이에 본 연구에서는 전자선 정도관리를 위한 기초연구로 PbO 기반의 선량계를 제작하였다. 그리고 6, 9, 12 MeV 에너지에 따른 재현성, 선형성을 분석하여 계측정확성과 정밀성을 평가하였다. 재현성 측정결과 6, 9, 12 MeV에서 각각 1.024%, 1.019%, 0.890%의 RSD 값으로 나타났다. 그리고 선형선 측정결과에서는 6, 9, 12 MeV에서 모두 0.9999 R2로 나타났다. 두 평가 모두 우수한 결과로 PbO 선량계의 계측정확성과 정밀성이 매우 우수한 것으로 나타났다.

전자선 치료 분야의 선량 측정을 위한 반도체 화합물의 적용가능성 연구 (Study on the Applicability of Semiconductor Compounds for Dose Measurement in Electron Beam Treatment)

  • 양승우;한무재;신요한;정재훈;최윤선;조흥래;박성광
    • 한국방사선학회논문지
    • /
    • 제14권1호
    • /
    • pp.1-6
    • /
    • 2020
  • 본 연구에서는 전자선 치료에서 전자선 선량 측정 시 교차교정이 필요한 기존 평행평판형이온함을 대체하고자 하였다. 광도전성 반도체 화합물 HgI2를 사용하여 선량계로 제작하였으며, 선형가속기에서 6, 9, 12 MeV 전자선에 대한 HgI2 선량계의 특성을 분석하였다. 그리고 기존 선량계와의 대체가능성과 전자선 선량계로서의 적용 가능성을 평가하고 전자선 선량계 개발의 기초연구로써 활용하고자 하였다. 재현성 평가결과, RSD는 6, 9, 12 MeV 에너지에서 각각 0.4246%, 0.5054%, 0.8640%로 나타나 출력 신호가 안정적인 것을 나타내었다. 선형성 평가결과, 직선형 추세선의 신뢰도 지표 R2값은 6 MeV에서 0.9999, 9 MeV에서 0.9996, 12 MeV에서 0.9997로 나타나 선량이 증가함에 따라 HgI2에 출력 신호가 비례한 것을 확인할 수 있었다. 본 연구의 HgI2 선량계는 전자선 측정 적용가능성이 매우 높은 것으로 판단되며, 전자선 검출에 대한 기초연구로 활용될 수 있을 것으로 사료된다.

에너지 저하체로서 아크릴과 SSD 가 9MeV 전자선의 측방 및 깊이선량분포에 미치는 효과 (Effect of an Acrylic Plate and SSD on Dose Profile and Depth Dose Distribution of 9 MeV Electron Beams)

  • 강위생
    • 한국의학물리학회지:의학물리
    • /
    • 제9권2호
    • /
    • pp.65-71
    • /
    • 1998
  • 1 cm 아크릴 판과 SSD 가 9MeV 전자선의 측방선량분포 및 깊이선량분포에 미치는 영향을 평가하여 아크릴 판을 전자선치료에서 에너지 저하체로 사용하는 타당성이 있는가를 분석하는 것이 목적이다 .Varian Clinac-2100C 에서 발생되는 9MeV 전자선을 7MeV로 저하시키기 위해 lcm 두께의 아크릴 판을 이용하였다. 아크릴 판은 엑스선 표적에서 65.4cm에 있는 전자선응용장치 상단에 두었으며, 조사면의 크기는 SSD 100cm 에서 l0$\times$10cm로 하였다. 100cm, 105cm, 110cm의 세 가지 SSD에 대해 선축상 깊이선량분포와 최대선량점깊이 (1.4cm) 에서 가로방향과 세로방향의 측방선량분포를 3D 물팬톰을 이용하여 측정하였다. 깊이선량분포에서는 최대선량점과 85% 선량점 ,50% 선량점 깊이와 표면에서 평균에너지, 실비정과 표면에서 최빈에너지를 비교하였다. 측방선량분포 측정으로부터 평탄도, 피넘브러폭, 실조사면크기를 비교하였다. 참조를 위한 목적에서 9MeV 전자선도 측정하였다. SSD가 l00cm 에서 l10cm로 증가함에 따라 7MeV 전자의 표면선량율이 85.5% 에서 82.2% 로 감소하였고, 선량증가영역을 제외하고는 깊이선량분포는 SSD에 영향을 받지 않았다. 평탄도는 7MeV가 4.7% 에서 10.4% 로 변하여 9MeV 의 1.4% 에서 3.5% 로 변한 것에 비하여 심하게 변하였다. 피넘브러폭은 7MeV 가 1.52cm 에서 3.03cm 로 증대하여 9MeV 의 1.14 cm에서 1.63cm로 증대된 것에 비해 심하게 변하였다. 7 MeV 전자선의 실조사면크기는 10.75cm에서 12.85 cm로 증대하여 9MeV 전자선의 10.32cm 에서 11.46cm 로 증대하는 것에 비해 심하게 변하였다. 가상선원표면거리는 7 MeV, 9MeV 각각에 대해 49.8cm,88.5cm였다. 에너지 저하체를 이용하는 경우에도 그렇지 않은 경우와 마찬가지로 SSD가 멀어져도 선량증가영역을 제외하고는 깊이선량분포는 변하지 않았다. 에너지 저하체를 사용하면 그렇지 않은 경우에 비해 SSD 가 증가하면 평탄도가 허용범위를 넘어 나빠지고, 피넘브러 폭은 넓어지며 조사면 크기가 더 심하게 커진다. 가상선원표면거리는 현저하게 짧아졌다. 결론적으로 전자선치료에서 특히 먼 SSD 에서 에너지 저하체를 이용하지 않는 것이 바람직하다고 생각된다.

  • PDF