• 제목/요약/키워드: Maximum flow

검색결과 3,397건 처리시간 0.027초

An Efficient Method on Constructing $ extsc{k}$-Minimal Path Sets for Flow Network Reliability

  • Lee, Seung-Min;Park, Dong-Ho
    • Journal of the Korean Statistical Society
    • /
    • 제29권3호
    • /
    • pp.297-306
    • /
    • 2000
  • An efficient method of constructing $textsc{k}$-minimal path sets to evaluate the reliability of a flow network is presented. The network is considered to be in a functioning state if it can transmit a maximum flow which is greater than or equal to a specified amount of flow, $textsc{k}$say, and a $textsc{k}$-minimal path set is a minimal set of branches that satisfies the given flow constraint. In this paper, under the assumption that minimal path sets of the network are known, we generate composite paths by adding only a minimal set of branches at each iteration to get $textsc{k}$-minimal path sets after possibly the fewest composition, and compute maximum flow of composite paths using only minimal path sets. Thereby we greatly reduce the possible occurrence of redundant composite paths throughout the process and efficiently compute the maximum flow of composite paths generated. Numerical examples illustrate the method.

  • PDF

비소음 측정을 이용한 저소음 축류홴 설계 (Design of Low Noise Axial Flow Fan Using Specific Sound Presssure Level)

  • 김창준;이동익
    • 소음진동
    • /
    • 제10권5호
    • /
    • pp.873-879
    • /
    • 2000
  • Experimental investigation was conducted to study the effects of pitch angle maximum camber on the performance and noise of an axial-flow fan used in outdoor-unit of air -conditioner. For this study the axial-flow fan whose pitch angle can be varied was made and the Specific sound Pressure Level and other coefficients were measured using the anechoic fan tester. It is found that pitch angle affects more severly than the maximum camber on the fan performance. On the while the maximum camber affects much on the specific sound power level. Present results show that it is important to choose the optimum pitch angle and maximum camber to design the high-performance and low-noise axial-flow fan and specific noise measured in the anechoic fan tester can be sued effectively for the design of low-noise fan.

  • PDF

The Increment Of The Local Scour Depth At Piers By Constructing The Bridge Between Existing Bridges

  • Choi, Gye-Woon;Kim, Gee-Hyoung
    • Water Engineering Research
    • /
    • 제1권2호
    • /
    • pp.159-168
    • /
    • 2000
  • In this paper, the increment of the local scour depth at piers by constructing the bridge between existing bridges is examined through the experiments in which 5 piers in the non-cohesive bed material in the experimental flume were installed. In the experiments the maximum distance of 25 times of the pier length and the maximum distortion width of 8 times of the pier width were utilized. Through the experimental studies, it was indicated that low flow, which can be characterized as the flow having low Froude numbers, the maximum bed configuration change is obtained when the piers are installed in the straight line in the flor direction without any distortion. However, In the high flow, which can be characterized as the flow having high Froude numbers, the maximum bed configuration change is obtained when the piers are installed with some distortion from the flow direction. The influence of the bed configuration by interaction between bridge piers is changed depending upon the Froude numbers, the distance between piers, and the distortion width between adjacent bridge piers. Also, because the scour patterns are affected by the bed configuration, the maximum scour should be increased by about 60% compared to that in a single pier if the interaction between bridge piers exists. It can be suggested that the maximum scour depth at bridge piers predicted by applying the existing equations should be increased if the interaction between bridge piers exist. Those cases are found when new bridges are constructed successively in the river in the urban area.

  • PDF

최대유량역에서 소형 축류 홴의 3차원 난류유동 특성에 관한 연구 (A Study on the Three-Dimensional Turbulent Flour Characteristics of a Small-sized Axial Fan at the Maximum Flowrate Region)

  • 김장권
    • 동력기계공학회지
    • /
    • 제4권3호
    • /
    • pp.25-33
    • /
    • 2000
  • This study represents three-dimensional turbulent flow characteristics around an axial fan measured at the operating point ${\varphi}=0.32$, which is equivalent to the maximum flowrate region, by using three-dimensional fiber-optic type LDA system. This LDA system is composed of a 5 W Argon-ion laser, two optics in back-scatter mode, three BSA's, a PC, and a three-dimensional automatic traversing system. A kind of paraffin fog is used for laser particles in this study. Mean velocity profiles around an axial fan along the downstream radial distance show that the streamwise and the tangential components exist as a predominant velocity and have the maximum value at the radial distance ratio 0.8, while the radial component has a small scale distribution and its flow direction is inward except a part of blade tip. The turbulent intensity profiles show that the radial component exists the most greatly. And also the turbulent kinetic energy shows about 60% as a maximum value at the radial distance ratio 0.9. Moreover, the Reynolds shear stresses do not exist at upstream flow, but the streamwise and the radial components of them show about 20% as a maximum value at the radial distance ratio 0.9 at downstream flow.

  • PDF

에너지소비를 고려한 실내공기청정기의 풍량별 입자 청정화능력 분석 (Analysis on Particle Cleaning Capacity of Indoor Air Cleaners for Different Flow Rates Considering Energy Consumption)

  • 한방우;강지수;김학준;김용진;원효식
    • 한국입자에어로졸학회지
    • /
    • 제9권3호
    • /
    • pp.139-147
    • /
    • 2013
  • The performances of indoor air cleaners including particle cleaning capacity and collection efficiency are usually tested at the condition of the maximum air flow rate of the air cleaners. However, the power consumption of the air cleaners is highly dependent on the air flow rate of the individual air cleaners. Therefore, there seems to be an optimized air flow rate for the air cleaning capacity considering power consumption. In this study, clean air delivery rate(or standard useful area as suggested room size) and power consumption have been investigated for different maximum air flow rates of 15 air cleaners and then compared those for different air flow rate modes of the individual 5 air cleaners selected from the 15 cleaners. For the maximum air flow rate conditions of 15 air cleansers, the power consumption per unit area was less related to the maximum air flow rate. However, for the different air flow rate modes of the selected 5 air cleaners, the lower power consumption per unit area was corresponding to the lower air flow rate mode of the individual air cleaners. When considering the operation time to the desired particle concentrations, there was an optimized one in the medium air flow rate modes for the individual air cleaners. Therefore, not only the maximum air flow rate but also lower air flow rates of individual air cleaners should be considered for estimating air cleaning capacity based on energy consumption per unit area.

수질오염총량관리 단위유역 유량자료와 하천유량 측정망 자료의 연계성 분석 (Relationship between the Flow data on the Unit Watersheds and on the Stream Flow Monitoring Network)

  • 박준대;오승영
    • 한국물환경학회지
    • /
    • 제29권1호
    • /
    • pp.55-65
    • /
    • 2013
  • It is very difficult to apply stream flow data directly to the management of Total Maximum Daily Loads because there are some differences between the unit watershed and the stream flow monitoring network in their characteristics such as monitoring locations and its intervals. Flow duration curve can be developed by linking the daily flow data of stream monitoring network to 8 day interval flow data of the unit watershed. This study investigated the current operating conditions of the stream flow monitoring network and the flow relationships between the unit watershed and the stream flow monitoring network. Criteria such as missing and zero value data, and correlation coefficients were applied to select the stream flow reference sites. The reference sites were selected in 112 areas out of 142 unit watersheds in 4 river basins, where the stream flow observations were carried out in relatively normal operating conditions. These reference sites could be utilized in various ways such as flow variation analysis, flow duration curve development and so on for the management of Total Maximum Daily Loads.

태양(太陽)에너지의 직접흡수식(直接吸收式) 수열판상(受熱板上)의 유체유동특성(流體流動特性)에 관(關)한 연구(硏究) (A Study on Characteristics of Fluid Flow on Direct Absorption Receiver from Solar Energy)

  • 박이동
    • 태양에너지
    • /
    • 제4권2호
    • /
    • pp.13-28
    • /
    • 1984
  • Direct Absorption Receiver and Thermal Storage System is a complex problem. This paper describes only characteristic of fluid flow on the receiver. The fluid thicknesses of Molten Salts (Melting Point : $397^{\circ}C$) flowing on the receiver of modified protopype ($10m{\times}10m$) were calculated theorectically, changing the receiver slope from 60 degree to 85 degree (5 steps). The receiver temperatures were $430^{\circ}C$ at the top part and $950^{\circ}C$ at the low part. The flow thickness of the Molten Salts at the top part of the receiver are around 1.9mm in the case of maximum insolution ($50{\times}10^6$juoule/sec; 58.898kg/sec of flow rate) and 2.0mm at the low part. In the case of 3/10 of maximum insolation (flow rate = 17.669kg/sec) the flow thickness at the top part are around 0.9mm and 0.4mm at the low part, and in the case of 1/10 of maximum insolation (flow rate = 5.889 kg/see) the flow thickness at the top part are around 0.6mm and 0.3mm at the low part. From experimental measurements of a normal fresh water thickness flowing on the model plate ($12.7cm{\times}111.76cm$), around 0.8mm at the top part of the plate and around 0.7mm at the low part were obtained in the case of maximum insolation (flow rate = 0.12496 kg/see). In the case of 3/10 (flow rate = 0.03748 kg/see) and 1/10 (flow rate = 0.012496 kg/see) of maximum insolation, around 0.5mm and 0.4mm at the top part, and around 0.3mm and 0.2mm at the low part were obtained respectively. The reason why the thickness of the Molten Salts increase at the low part of the receiver only in case of maximum insolation is that decreasing rate of the viscosity of the Molten Salts is larger than decreasing rate of the density of the Molten Salts during temperature increase from the top to the low receiver plate and decrease of the fluid velocity in accordance with continuity principle. In all cases without the above maximum insolation, the thickness of the Molten Salts and the fresh water decreased at the low part of the plate because of gravity force effects rather than friction effects and of continuity principle. All simillar flow patterns were obtained through all cases of the insolation making an exception of only maximum insolation.

  • PDF

The assessment of the performance of drug-eluting stent using computational fluid dynamics

  • Seo, Tae-Won;Barakat, Abdul I.
    • Korea-Australia Rheology Journal
    • /
    • 제21권4호
    • /
    • pp.281-288
    • /
    • 2009
  • Numerical investigations have been conducted on the assessment of the performance of drug-eluting stent. Computational fluid dynamics is applied to investigate the flow disturbances and drug distributions released from the stent in the immediate vicinity of the given idealized stent in the protrusion into the flow domain. Our simulations have revealed the drug concentration in the flow field due to the presence of a drug-eluting stent within an arterial segment. Wall shear stress increases with Reynolds number for a given stent diameter, while it increases with stent diameter for a given Reynolds number. The drug concentration is dependent on both Reynolds number and stent geometry. In pulsatile flow, the minimum drug concentration in the zone of inter-wire spacing occurs at the maximum acceleration of the inlet flow while the maximum drug concentration gains at the maximum deceleration of the inlet flow. These results provide an understanding of the flow physics in the vicinity of drug-eluting stents and suggest strategies for optimal performance of drug-eluting stent to minimize flow disturbance.

포탄의 탄두 주위에서의 유동해석 (Flow Analysis near Shell Warhead)

  • 최계광;조재웅
    • 한국기계가공학회지
    • /
    • 제19권2호
    • /
    • pp.18-23
    • /
    • 2020
  • The maximum speed and pressure distribution close to a warhead are altered based on the warhead shape, thereby resulting in changes to the flight distance and the destructive power. In this study, flow analysis was carried out based on the warhead shell shape. The maximum flow rate was detected at the side of shell, with a lower flow rate being found at the rear of the shell. In addition, the maximum pressure was detected at the warhead. It was also found that the reduction in the flow rate between the rear and the side of the shell in model A was smaller than that in model B. The obtained results are expected to be useful in the future design of shell warhead shape.

하천 유량.수질변화 특성을 고려한 수질오염총량관리 기준유량 조건에 관한 연구 (A Study on the Suggestions for Standard Flow Conditions considering the Variation of Stream Flow and Water Quality for the Management of Total Maximum Daily Loads)

  • 박준대;오승영;최윤호
    • 한국물환경학회지
    • /
    • 제28권3호
    • /
    • pp.426-435
    • /
    • 2012
  • The variation of stream flow is the one of the most important factors which influence on that of water quality in the unit watershed. The target water quality goal is established and permissible load is allotted in the base of the standard flow condition along with its water quality for the management of Total Maximum Daily Loads (TMDLs). A standard flow selected could cause problems in the load allotment if it was not properly arranged. This study reviewed the acquisition of water quality data, the self-variation and the retainability in water quality on the specific flow conditions. This study also proposed the median and the adjusted average flow condition out of general flow conditions as alternative standard flow conditions. It is considered that the alternatives can make the water quality data easily acquired and the water quality representativeness more enhanced on the standard flow conditions.