Design of Low Noise Axial Flow Fan Using Specific Sound Presssure Level

비소음 측정을 이용한 저소음 축류홴 설계

  • Published : 2000.10.01

Abstract

Experimental investigation was conducted to study the effects of pitch angle maximum camber on the performance and noise of an axial-flow fan used in outdoor-unit of air -conditioner. For this study the axial-flow fan whose pitch angle can be varied was made and the Specific sound Pressure Level and other coefficients were measured using the anechoic fan tester. It is found that pitch angle affects more severly than the maximum camber on the fan performance. On the while the maximum camber affects much on the specific sound power level. Present results show that it is important to choose the optimum pitch angle and maximum camber to design the high-performance and low-noise axial-flow fan and specific noise measured in the anechoic fan tester can be sued effectively for the design of low-noise fan.

Keywords

References

  1. 三菱重工技報 v.27 no.3 Noise Reduction in Propeller Fans for Air Conditioners 山口信行;近藤文男;靑木美昭;當永哲雄
  2. The 4th Asian International Conference on Fluid Machinery Improvement in Performance of Propeller Fans for Outdoor Units of Airconditioners Sato. S.;Kinoshita, K.
  3. 日本機械學會論文集(B編) v.56 no.531 A Study on Noise Reduction for Small Axial Flow fans Kamaya, S;Kanabayashi, S.
  4. Quality Engineering Using Robust Design Phadke, M. S.
  5. 2nd International Conference on Pumps and Fans Parametric Study on the Noise in a Small Axial Fan Rew, H. S.;Cha, J. E.;Kim. C. J.;Choi, M. Y.;Kim. T. J.
  6. 동계학술발표논문집 Effects of Pitch Angle and Maximum Camber on an Axial Flow Fan Performance Kim. C. J.;Jang, C. M.;Choi, M. Y.;Rhee, D. I.
  7. Axial Flow Fans and Ducts Walls, R. A.
  8. 동계학술발표논문집 High Efficiency Mixed Flow Fan by 3D Design Jang, C. M.;Jung, Y. G.;Rhee, D. I.
  9. 추계학술발표논문집 Drsign of Low Noise Fan Using Anechoic Fan Tester Kim, C. J.;Jung, Y. G.;Rhee, D. I.