• Title/Summary/Keyword: Maximum Temperature Difference

Search Result 735, Processing Time 0.03 seconds

Sn-3.5Ag 솔더를 이용한 페리퍼럴 어레이 플립칩의 열 성능 분석

  • Lee Taek Yeong
    • Proceedings of the International Microelectronics And Packaging Society Conference
    • /
    • 2003.11a
    • /
    • pp.270-277
    • /
    • 2003
  • Thermal performance of flip chip bonding with Sn-3.5Ag solder ball was studied. The temperature distribution was measured with IR(InfraRed) camera of 25 urn resolution. The measurement shows that most of the samples had much higher maximum temperature than average temperature. With central heater and 2.5 (W), the difference between maximum and average temperature is over $80^{\circ}C$. The distribution was influenced by the location of heater, the distance from heater to flip chip bonding, and the passivation opening of solder bumps. To reduce the maximum temperature, the bigger passivation opening, the smaller chip size, and the closer location of heater to flip chip bumps are preferrable.

  • PDF

Study on the Establishment of Threshold Criteria for Heat Health Watch Warning System in Korea; Part II: Improvement of Criteria (고온건강경보시스템 기준 설정에 관한 연구 ( II ) - 설정 기준 개선 -)

  • Jung, Woo-Sik;Park, Jong-Kil;Kim, Eun-Byul;Song, Jeong-Hui
    • Journal of Environmental Science International
    • /
    • v.18 no.7
    • /
    • pp.781-796
    • /
    • 2009
  • The current standard level of Heat Health Watch Warning System consider both daily maximum temperature and daily maximum heat index(HI), but current standard could not consider daily maximum HI due to the difficulties in forecasting when we consider both daily maximum temperature and daily maximum HI and no considering HI because relative humidity could not observed for some regions. So, Newly established standard level of Heat Health Watch Warning System is based on daily maximum temperature exceeding $30^{\circ}C$ for two consecutive days or daily minimum temperature exceeding $25^{\circ}C$ and daily maximum temperature exceeding $30^{\circ}C$. These days are called "extreme heat days". On extreme heat days, the standard of extreme heat advisory is based on daily maximum temperature among exceeding $32.7^{\circ}C$ and not exceeding $34.8^{\circ}C$, and extreme heat warning is based on daily maximum temperature exceeding $34.8^{\circ}C$. ANOVA analysis was carried out using the data of Seoul Metropolitan City in 1994 to check the robustness of the new standard level of Heat Health Watch Warning System from this study, in particular for mortality variable. The results reveal that the new standard specifies excess mortality well, showing significance level of 0.05 in the difference of excess mortality for each phase.

Suggestion of New Heat Tariff Assessment for District Heating Using Exergy (엑서지를 이용한 지역난방 열요금 제도 제안)

  • Moon, Jung-Hwan;Lee, Jae-Heon;Moon, Seung-Jae;Yoo, Ho-Seon
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.912-918
    • /
    • 2008
  • In this study, the exergy which could be reflected on energetic and economic value was used to assess on heat tariff of district heating system instead of enthalpy. Exergy is difficult to apply directly to present heat charge system because of complex calculation. Therefore, the difference between supply and return temperature was converted to the exergy temperature difference for easily calculating the amount of heat. As a result of exergy analysis for a DH substation, the exergy temperature difference were not affected on surrounding temperature and pressure loss. Supply temperature, maximum difference between supply temperature and return temperature had a main effect on the exergy temperature difference. The new heat charge of a DH user was slightly reduced in winter compared with previous heat charge. Heat charges in other seasons were almost same. It is thought that heat tariff using exergy will be appropriate in terms of both DH supplier and consumer.

  • PDF

A Numerical Analysis on Thermal Stratification Phenomenon by In-Leakage in a Branch Piping

  • Park Jong-Il
    • Journal of Mechanical Science and Technology
    • /
    • v.19 no.12
    • /
    • pp.2245-2252
    • /
    • 2005
  • Thermal stratification in the branch piping of power plants can be generated by turbulent penetration or by valve leakage. In this study, a numerical analysis was performed to estimate the thermal stratification phenomenon by in-leakage in the SIS branch piping of nuclear power plant. Leakage rate, leakage area and leakage location were selected as evaluation factors to investigate the thermal stratification effect. As a result of the thermal stratification effect according to leakage rate, the maximum temperature difference between top and bottom of the horizontal piping was evaluated to be about 185K when the valve leakage rate was about 10 times as much as the allowed leakage rate. For leakage rate more than 10 times the allowed leakage rate, the temperature difference was rapidly decreased due to the increased mixing effect. In the result according to leakage area, the magnitude of temperature difference was shown in order of $3\%,\;1\%\;and\;5\%$ leakage area of the total disk area. In the thermal stratification effect, according to the leakage location, temperature difference when leakage occurred in the lower disk was considerably higher than that of when leakage occurred in the upper disk.

Suggestion for a New Exergy-Based Heat-Tariff Assessment for a District-Heating System (엑서지를 이용한 지역난방 열요금 제도 제안)

  • Moon, Junghwan;Yoo, Hoseon;Lee, Jae-Heon;Moon, Seungjae
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.4
    • /
    • pp.202-211
    • /
    • 2017
  • In this study, the exergy that can be reflected in the energetic and economic values was used to assess the heat tariff of a district heating (DH) system instead of the enthalpy. It is difficult to directly apply the exergy to the current heat-charge system because of the complicated calculation; therefore, the difference between the supply and return temperatures was converted to the exergy-temperature difference for the ease of the heat-amount calculation. As a result of the exergy analysis for a DH substation, the exergy-temperature difference did not affect the surrounding temperature and pressure loss. The supply temperature and the maximum difference between the supply temperature and the return temperature exerted the main effect on the exergy-temperature difference. The new heat charge of a DH user was slightly reduced in winter compared with the previous charge, but the heat charges in the other seasons are almost the same. It is concluded from the assessment of the heat tariff for which the exergy is used that this tariff is more feasible for both DH suppliers and consumers compared with enthalpy.

Evaluation of Cooling Performance of PDP by Heat Spreader (Heat spreader를 통한 PDP의 냉각성능 평가)

  • Kim, Jae-Jung;Chang, Seog-Weon;Cho, Young-Jin;Lee, Tae-Gu;Noh, Hong-Koo;Lee, Jae-Heon
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.612-617
    • /
    • 2001
  • This paper reports the cooling performance of a PDP(plasma display panel) with a heat spreader by means of numerical analysis. Due to the simplifications and assumptions inherent in the analysis, computed results are found to differ those of the experiment by 13%. Calculation shows a maximum temperature of $65^{\circ}C$ for the plasma glass, as opposed to the allowable temperature of $90^{\circ}C$, producing a temperature difference of $25^{\circ}C$ between the upper and lower regions. This is enough to cause cracks in the plasma glass. In order to avoid this, more ventholes are added at the upper center region of the back cover, thereby causing a $3^{\circ}C$ drop in the maximum temperature, which reduces the temperature difference to $12^{\circ}C$. The new design gives more uniform temperature distribution across the plasma glass.

  • PDF

Comparative Performance Analysis of Pressurized Solid Oxide Fuel Cell / Gas Turbine Hybrid Systems Considering Different Cell Inlet Preheating Methods (셀 입구 예열방법에 따른 가압형 고체산화물 연료전지/가스터빈 하이브리드 시스템의 성능 비교 해석)

  • Yang Won Jun;Kim Jae Hwan;Kim Tong Seop
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.29 no.6 s.237
    • /
    • pp.722-729
    • /
    • 2005
  • Design analysis of the solid oxide fuel cell and gas turbine combined power system is performed considering different methods for preheating cell inlet air. The purpose of air preheating is to keep the temperature difference between cell inlet and outlet within a practical design range thus to reduce thermal stress inside the cell. Three different methods considered are (1) adopting a burner in front of the cell, (2) adopting a preheater (heat transfer from the main combustor) in front of the cell and (3) using recirculation of the cathode exit gas. For each configuration, analyses are carried out for two values of allowable maximum cell temperature difference. Performance characteristics of all cases are compared and design limitations are discussed. Relaxation of the cell temperature difference (larger difference) is proved to ensure higher efficiency. Recirculation of the cathode exit gas exhibits better performance than other methods and this advantage becomes more prominent as the constraint of the cell temperature difference becomes more severe (smaller temperature difference).

Daily Changes in Red-Pepper Leaf Surface Temperature with Air and Soil Surface Temperatures

  • Eom, Ki-Cheol;Lee, Byung-Kook;Kim, Young-Sook;Eom, Ho-Yong
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.47 no.5
    • /
    • pp.345-350
    • /
    • 2014
  • This study was conducted to investigate the changes in daily surface temperature of red pepper leaf compared to air and soil surface temperature. The maximum, minimum and average daily temperatures of red pepper leaf were 27.80, 11.40 and $19.01^{\circ}C$, respectively, which were lower by 0.10, 7.60 and $3.86^{\circ}C$ than air temperature, respectively, and lower by 15.00, 0.0 and $4.38^{\circ}C$ than soil surface temperature, respectively. Mean deviations of the difference between measured and estimated temperature by the E&E Model (Eom & Eom, 2013) for the air and surface temperature of red pepper leaf and soil were 0.64, 1.82 and $4.77^{\circ}C$, respectively. The relationships between measured and estimated scaled factor of the air and surface temperature of red pepper leaf and soil were very close to the 1:1 line. Difference between air and surface temperature of red pepper leaf showed a linear decreasing function with the surface temperature of red pepper leaf. Difference between soil surface temperature and air and surface temperature of red pepper leaf linearly increased with the soil surface temperature.

A Study on Thermal Stratification Phenomenon due to In-Leakage in the Safety Injection Piping of Nuclear Power Plant (원전 안전주입 배관에서의 In-Leakage 에 의한 열성층 현상에 관한 연구)

  • Kim, K.C.;Park, M.H.;Youm, H.K.;Kim, T.Y.;Lee, S.K.
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.1633-1638
    • /
    • 2003
  • In case that in-leakage through the valve disk occurs, a numerical study is performed to estimate on thermal stratification phenomenon in the Safety Injection piping connected with the Reactor Coolant System piping of Nuclear Power Plant. As the leakage flow rate increases, the temperature difference between top and bottom of horizontal piping has the inflection point. In the connection point of valve and piping, the maximum temperature difference between top and bottom was 185K and occurred in the condition of 10 times of standard leakage flow rate. In the connection point of elbow and horizontal piping, the maximum temperature difference was 145K and occurred in the condition of 15 times of standard leakage flow rate. In the vertical piping of Safety Injection piping, the near of connection point between elbow and vertical piping showed the outstanding thermal stratification phenomenon in comparison with another region because of turbulent penetration from Reactor Coolant System piping. In order to prevent damage of piping due to the thermal stratification when in-leakage through the valve disk occurs, the connection points between valve and piping, and the connection points between elbow and piping need to be inspected continually.

  • PDF

Thermal Management of a Ni/MH Battery Module for Electric Vehicle (전기자동차용 Ni/MH 전지 Module의 열관리기술)

  • Kim, Junbom
    • Applied Chemistry for Engineering
    • /
    • v.8 no.6
    • /
    • pp.1034-1040
    • /
    • 1997
  • Temperature distribution of battery module consists of 11 batteries of 90Ah rate is analyzed using commercial software NISA II. Equivalent thermal resistance network is used to reduce the number of element in calculating heat transfer through a medium composed of several different thermal conductivity layers. Orthotropic model is used to put different thermal conductivity values according to Cartesian coordinate. Aluminum cooling fins are inserted in the middle of batteries to reduce battery module temperature. The cooling fin at the end of the module does not necessary in reducing maximum temperature. Combined effect of front and side cooling fin is analyzed to reduce the temperature difference among batteries. The maximum temperature difference among batteries is reduced within $3^{\circ}C$ when 4 aluminum cooling tin of 1mm thickness is inserted in battery module.

  • PDF